Noise Evaluation and Measures of Cooling Tower at Apartment (아파트 냉각탑의 소음 평가 및 대책)

  • Lee, Kyu-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1020-1023
    • /
    • 2004
  • Recently, Cooling tower are used the necessary element in a residential area and living space on the viewpoint of indoor temperature control. The purpose of this study is to assistance the comfortable environment and economical measures of noise transmission mechanism on tile cooling tower. The results show that noise evaluation interact the main factor of distance reduction and diffraction reduction. Noise criterion apply to the NC level and equivalent transmission loss about already the design of noise reduction.

  • PDF

A Study on the Residential Stress and Inclination to Move (주거환경 스트레스와 주거이동 성향에 관한 연구)

  • 고경필
    • Journal of the Korean housing association
    • /
    • v.8 no.2
    • /
    • pp.71-84
    • /
    • 1997
  • The Purpose of this study is to estimate how inclination to move can be appeared by understanding the cognition of a resident on stress due to the residential environment. 240 housewives living in Chiniu were Questioned statistical analysis were used with factor analysis, F-test. Duncan's Multiple range analysis, stepwise regression analysis and stepwise discriminant analysis, The result were summarized as follows 1) The stress of residential environment were clissified by six factors indoor facility, educational environmental. indoor structure, air Pollution noise, traffic convenience. 2) The extent of a stress from residential environment was significantly different in the socio-demographic variable and housing-related variable. 3) The stress of residential environment were affected by the direction of house. 4) The variable discriminating inclination to move were the stress of residential environment(air Pollution). an educational level, the type of housing possession, residential Period and the size of house.

  • PDF

Prediction of Concrete Slab Acceleration and Floor Impact Noise Using Frequency Response Function (주파수 응답함수를 이용한 콘크리트 슬래브 가속도 및 바닥충격소음 예측)

  • Mun, Dae-Ho;Park, Hong-Gun;Hwang, Jae-Seung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.6
    • /
    • pp.483-492
    • /
    • 2014
  • Uncomfortable feelings of occupants by indoor floor impact noise in a residential building are not accurately represented by the floor impact noise from a standard impact source. It is due to the characteristics of standard impact sources, which are different from the impact forces produced by occupants. It varies significantly by impact source, and it is not easy to be replicated for testing. As a result, the indoor floor impact noise under different acoustic conditions cannot be directly compared. Using frequency response function(FRF), which represents the input-output relationships of a dynamic system, it is possible to examine the characteristics of the system. Especially, FRF can predict the response of a linear dynamic system subjected to various excitation. To determine the relationship between impact force and the corresponding response of dynamic system in residential building, the acceleration response of a concrete slab and the floor impact noise in the living room, produced by bang-machine and rubber-ball excitation, were measured. The test results are compared to the estimates based on FRF and impact force spectrum.

A study on the capability of inverse A weighting through the auditory perception test (청감실험을 통한 역A특성 평가방법의 타당성 검토)

  • 이성찬;전진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.586-591
    • /
    • 2002
  • Recently, the research and discussion to set up the evaluation standard for nor impact noises in multistory residential buildings has been vividly carried out In Korea. Therefore, the correlation between the methods and auditory responses was investigated through this research to investigate the applicability of the L index evaluation method and the reverse A characteristics evaluation method that are listed in JIS A 1419 since Japanese circumstance are similar to Korean after evaluating the duality of Korean multistory residential buildings. As a result, it was found that the correlation between the value resulted from L index evaluation and the value from reverse A characteristics evaluation is high. In addition, it was also revealed that human responses to each Impacter was similar. Consequently, it is considered th:31 the tendency about the two methods would be similar.

  • PDF

A Study on Noise Marking Obligation System for Construction Equipments in Europe (유럽의 건설기계 소음표시의무 제도)

  • Park, Sang-Kyu;Park, In-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.104-108
    • /
    • 2005
  • With the improvement of living quality, people's desire for quiet living environment keeps increasing. In particular, complaints about the noise emission by constrcution equipments around residential areas take most part of the noise related complaints. In this study, based on the European Directive/20n/14/EC, noise marking obligation system for the high noise construction equipment of Europe has been reviewed to implement the similar system in Korea.

  • PDF

The Use of Psycho-Acoustic Method on the Evaluation of the Road Traffic Noise in the Urban Residential Area (도시주거지역 도로교통소음 평가에 있어서 청감실험의 이용에 관한 연구)

  • Kook, Chan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.12 no.3
    • /
    • pp.43-48
    • /
    • 1993
  • This study was carried out to verificate the possibility of using the laboratory setting psycho-acoustic experiment compared with the field and to delineate the appropriate indices in evaluating the Noisiness of road traffic noise by means of psycho-acoustic method. Reviewing the typical patterns of traffic noises depending upon the shapes ad conditions of the road, the road traffic noises in several representative points in the major residential areas in Kwangju city were recorded and reproduced with the noise levels modified in various steps. With these 20 sound sources, psycho-acoustic experiments in the laboratory were performed on 11 volunteer subjects. And then, psycho-acoustic experiments in the real field were performed on 10 volunteer subjects to compare the results of the laboratory experiment, the results are summerized as follows : 1. The psycho-acoustic experiments in the laboratory elicited the data well matching with those obtained in the field, resulting in even higher corelation levels. This indicates that the field assessement of responses to the noise can be replaced by the evaluatioin in the laboratory settings which render many variables easily controlled and that the responses of the residents to the noise can be easily predicted in the laboratory by applying this method. 2. Also among the complex indices, such as Noise Pollution Level or Annoyance Index high correlations were detected. On the other hand, low corelations were noted among Traffic Noise Index. 3. Highly significant correlations were found among the direct indices such as Leq, L\sub 10\, On the other hand, low correlations were detected among L\sub 50\.

  • PDF

Noise distribution analysis and noise barrier measures of thermal power plant (화력발전소의 소음분포 해석 및 방음벽 대책)

  • Yun, Jun-Ho;Kim, Won-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.2
    • /
    • pp.105-112
    • /
    • 2020
  • An analysis model of noise map is proposed to evaluate and reduce the acoustical noise of power plant and its surroundings. The sound powers of many noise sources are estimated by measuring the sound levels of major equipments in the power plant. The analysis of noise has been made by using ENPro that is a commercial program for environmental noise prediction. The proposed model is verified by comparing the results from noise analysis and measurement at several points of the power plant units 1 through 4, and residential areas. It is shown that noise map simulation using the proposed model has a reliability, since the overall noise level approximates within the error of ±2 dB. Furthermore, through noise analysis, the increasing effect of noise due to newly established units 5 and 6 on residential areas is also analyzed. Consequently, the noise barrier is designed to meet an environmental noise standard and satisfy low cost and safety conditions.

A Study on the Noise Level of Residential Area in Gwangju (광주지역의 택지개발지구 소음도 조사연구)

  • 강영주;백계진;김찬중;박강수;서광엽;문향미;고은미;고영춘;김연희
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.6
    • /
    • pp.520-527
    • /
    • 2004
  • This study was carried out to investigate the present state of noise level including three general districts and two roadside areas at the Residential Area such as Sangmu, Pungam, Moonheung, and Ilgok Area. The noise level was measured quarterly. The results were shown that the noise level of day time was no great difference and that noise level of night time represented ranges between 44 to 48 dB(A). The noise level of day time was higher 4 to 7 dB(A) than night time. At the roadside areas, average noise level of day time was suitable to the requirements of environmental criteria. However. only one point of two points exceeded the noise level of environmental criteria. except Pungam Area. The noise level of night time in all areas was 58 dB(A), showing more 3 dB(A) than the environmental criteria (55 dB(A)). The difference of noise level between day time and night time was approximately 5 to 7 dB(A) in all Area. The noise level of day time was not dependent on all seasons, whereas that night time is dependent on season, especially showing lower noise level in winter. Showing the changes on the times in a day, it reached the highest at 16:00, mainly resulting in a lot of activities of people. The maximum noise level (Lmax) from 3 or 4 military aircraft showed almost the same. The noise level of aircraft in Sangmu Area was 71.5∼78.1 WECPNL.