• Title/Summary/Keyword: Residential Noise

Search Result 259, Processing Time 0.03 seconds

A Study on the Tank Noise Reduction Techniques of Power Transformers (전력용 변압기 외함 소음저감에 관한 연구)

  • Kweon, Dong-Jin;Koo, Kyo-Sun;Kim, Jung-Chan;Kim, Yoo-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1759-1766
    • /
    • 2008
  • According to the increase of power demand and expansion of downtown, it is necessary to install transformers additionally in operating substations and construct substations in residential area. But the public complaint has been increased due to the transformer noise of the substation. KEPCO has used a vibration preventing pad, various soundproof walls and an encloser to transformers in outdoor substations, and a soundproof door, shutter and wind-path soundproof equipment in indoor substations to block the sound propagation from the transformers. But these noise reduction methods are not satisfied. It should be considered to reduce transformer noise itself. In this paper, we investigated tank noise reduction techniques to develope a low noise transformer. According to the mode analysis of transformer tank, we found out characteristics and locations of noise on the tank, and it's nature vibration was also analysed. On the basis of these analysis, reinforcement equipment was installed around transformer tank, and ellipse shape tank was changed to round shape tank. The effect of noise reduction was evaluated using noise generation source.

Reduction of Floor Impact Noise and Impact Force for PVC Floor Covering and Floor Mat (PVC 바닥 마감재와 바닥 매트의 바닥충격음 및 충격력 저감)

  • Mun, Dae-Ho;Song, Guk-Gon;Lee, Cheol-Seung;Park, Hong-Gun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.7
    • /
    • pp.501-508
    • /
    • 2014
  • Floor finishing materials such as floor coverings and floor mats can reduce floor impact noise easily. When an impact was applied to the floor, its finishing material is deformed and the impact force that was applied to the concrete slab is changed. The softer finishing materials were, the more impact force decreased. An experimental study was performed using 14 PVC floor coverings and 16 floor mats to capture the characteristics of impact force and impact noise in the residential buildings. The test results show that the impact force spectrum and the floor impact noise spectrum have a linear relationship in the case of a bare concrete slab, and the characteristics of impact force reduction are the same as those of floor impact noise reduction.

A study on the Prediction of the Road Traffic Noise Distribution around the High-Rise Building (도로교통소음에 대한 고층건물의 외부 소음분포 예측에 관한 연구)

  • Jung, Suk-Hwan;Kim, Dae-Woong;Lim, Tae-Sub;Kim, Byung-Seon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1087-1092
    • /
    • 2006
  • Recently, traffic noise level is rapidly increasing, and it is crowed caused by recently overcrowded and overgrown cities, and increasing traffic volume is emerging as a major factor of disrupting the living and working environment. In this situation, citizens are increasingly complaining about the traffic noise. The noise level of in major cities in Korea is serious and affects on citizens physically and psychologically. Many people live in residential areas around crowed roads in major cities, such as Seoul. Accordingly, the purpose of this study is to predict outside noise distribution of building through survey and simulation to make better sound insulation performance research. The result of this study shows that the traffic noise is influenced from ground 50m and analyzed that form of building and arrangement type must be considered to the level of noise decrease.

  • PDF

A Study on Public Nuisance in Seoul, Pusan and Daegu Cities Part I. Survey on Air Pollution and Noise Level (공해(公害)에 관(關)한 조사연구(調査硏究) 제일편(第一編) : 서울, 부산(釜山), 대구(大邱) 지역(地域)의 대기오염(大氣汚染) 및 소음(騷音)에 관(關)한 비교조사(比較調査) 연구(硏究))

  • Cha, Chul-Hwan;Shin, Young-Soo;Lee, Young-Il;Cho, Kwang-Soo;Choo, Chong-Yoo;Kim, Kyo-Sung;Choi, Dug-Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.4 no.1
    • /
    • pp.41-64
    • /
    • 1971
  • During the period from July 1st to the end of November 1970, a survey on air pollution and noise level was made in Seoul, Pusan and Taegu, the three largest cities in Korea. Each city was divided into 4-6 areas; the industrial area, the semi-industrial area, the commercial area, the residential area, the park area and the downtown area. Thirty eight sites were selected from each area. A. Method of Measurement : Dustfall was measured by the Deposit Gauge Method, sulfur oxides by $PbO_2$ cylinder method, suspended particles by the Digital Dust Indicator, Sulfur dioxide ($SO_2$) and Carbon Monoxide (CO) by the MSA & Kitakawa Detector and the noise levels by Rion Sound Survey meter. B. Results: 1. The mean value of dustfall in 3 cities was $30.42ton/km^2/month$, ranging from 8.69 to 95.44. 2. The mean values of dustfall by city were $33.17ton/km^2/month$ in Seoul, 32.11 in Pusan and 25.97 in Taegu. 3. The mean values of dustfall showed a trend of decreasing order of semi-industrial area, downtown area, industrial area, commercial area, residential area, and park area. 4. The mean value of dustfall in Seoul by area were $52.32ton/km^2/month$ in downtown, 50.54 in semi-industrial area, 40.37 in industrial area, 24,19 in commercial area, 16.25 in park area and 15.39 in residential area in order of concentration. 5. The mean values of dustfall in Pusan by area were $48.27ton/km^2/month$ in semi-industrial area, 36.68 in industrial area 25.31 in commercial area, and 18.19 in residential area. 6. The mean values of dustfall in Taegu by area were $36.46ton/km^2/month$ in downtown area, 33.52 in industrial area, 20.37 in commercial area and 13.55 in residential area. 7. The mean values of sulfur oxides in 3 cities were $1.52mg\;SO_3/day/100cm^2\;PbO_2$, ranging from 0.32 to 4.72. 8. The mean values of sulfur oxides by city were $1.89mg\;SO_3/day/100cm^2\;PbO_2$ in Pusan, 1.64 in Seoul and 1.21 in Taegu. 9. The mean values of sulfur oxides by area in 3 cities were $2.16mg\;SO_3/day/100cm^2\;PbO_2$ in industrial area, 1.69 in semi-industrial area, 1.50 in commercial area, 1.48 in downtown area, 1.32 in residential area and 0.94 in the park area, respectively. 10. The monthly mean values of sulfur oxides contents showed a steady increase from July reaching a peak in November. 11. The mean values of suspended particles was $2.89mg/m^3$, ranging from 1.15 to 5.27. 12. The mean values of suspended particles by city were $3.14mg/m^3$ in Seoul, 2.79 in Taegu and 2.25 in Pusan. 13. The mean values of noise level in 3 cities was 71.3 phon, ranging from 49 to 99 phon. 14. The mean values of noise level by city were 73 phon in Seoul, 72 in Pusan, and 69 in Taegu in that order. 15. The mean values of noise level by area in 3 cities showed a decrease in the order of the downtown area, commercial area, industrial area and semi-industrial area, park area and residential area. 16. The comparison of the noise levels by area in 3 cities indicated that the highest level was detected in the downtown area in Seoul and Taegu and in the industrial area in Pusan. 17. The daily average concentration of sulfur dioxides ($SO_2$) in 3 cities was 0.081 ppm, ranging from 0.004 to 0.196. 18. The daily average concentrations of sulfur dioxides by city were 0.092 ppm in Seoul, 0.089 in Pusan and 0.062 in Taegu in that order. 19. The weekly average concentration of carbon monoxides(CO) was 27.59 ppm. 20. The daily average concentrations of carbon monoxides by city were 33.37 ppm. in Seoul, 25.76 in Pusan and 23.65 in Taegu in that order. 21. The concentration of $SO_2$ and CO reaches a peak from 6 p. m. to 8 p. m. 22. About 3 times probably the daily average concentration of CO could be detected in the downtown area probably due to heavy traffic emission in comparison with that in the industial area. 23. As for daily variation of the concentration of $SO_2$ and CO it was found that the concentration maintains relatively higher value during weekdays in the industrial area and on the first part of the week in the downtown area.

  • PDF

Grading of Architectural Plumbing Noise using Psycho-Acoustic Experiment (청감실험을 이용한 건축설비소음의 등급화)

  • You, Hee-Jong;Jung, Chul-Woon;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.488-492
    • /
    • 2007
  • Since Equipment-Noises occurring in machine room penetrate wall-body and travel to the adjacent room in the form of air-borne sound and structure-borne sound, it is appearing as the main factor that injures a peaceful residential environment, and due to this, such noise-damage is currently increasing rapidly. Consequently, despite the measures for sound-insulation and soundproof against the equipment-noise penetrated wall-body is urgently required, but as the subjective evaluation considered for psychological response about the equipment-noise was not practiced, many dissatisfactions are still raising even after some measure was taken. On such point of view, this Research, at the spot, has actually measured the equipment-noise that had permeated various wall-bodies, and examined its physical characteristics, thence based upon this, has conducted Psycho-Acoustics Experiment and investigated the interrelation between the physical evaluation value and psychological reaction value. It is considered that such study result could be utilized as the useful material at the time of establishment of the Grading Standard for the insulation performance against the Architectural Plumbing Noise, in the future.

  • PDF

A Study on Review of the Current Noise Impact Assessment for the Power Plant (발전소 플랜트 소음영향평가 현황 및 민원사례를 통한 개선방향 연구)

  • Choung, Tae-Ryang;Park, Young-Min;Son, Jin-Hee;Cho, Man-Hee;Hong, Woong-Ki;Song, Jeong-Un
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.6
    • /
    • pp.941-949
    • /
    • 2012
  • The various plants including power plants have been increased near downtown in accordance with the policy objective of rising the power feed rate and development projects. As a result of these various plants near residential area, noise damage complaints has been raised very often. The power plant is included with the range of environmental impact assessment project. Nevertheless, environmental noise issues regarding construction of these power plants have arisen. Accordingly it is time to consider the environmental and social issues of plants noise in accordance with the government's policy objectives of increased power production. In this study, we reviewed the current noise impact assessment and we also sought solutions to these issues. In order to minimize the problem of noise impact on neighborhood and residents, we intended to propose alternative method of 3D simulation in dealing with these issues.

An Experimental Study on the noise Rating of H.D. TV sets by Psycho-acoustic Experiments (청감실험을 통한 고화질 TV set 소음평가에 관한 실험적 연구)

  • Lee, Ju-Yeob;Park, Hyeon-Ku;Lee, Tai-Gang;Kim, Hye-Jin;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.862-869
    • /
    • 2006
  • The purpose of this study is to propose the proper vocabularies for evaluating H.D TV set fan noise in residential condition. To achieve this goal, psycho-acoustic experiments were carried out with TV set fan noise modulated at specific frequency band. finally, a correlation analysis between vocabularies, and a factor analysis of psycho-acoustical responses were conducted. As a result of this study, followings are suggested. Analyzing the psycho-acoustical response corresponding to the various sound level, the higher the sound levels, the higher the response values were. It is estimated that the sound level determined psycho-acoustical responses. On the degree of response to fan noise, the initial level of negative feeling is located on $35{\sim}40$ dB(A). The factor of evaluating H.D. TV set fan noise has induced three the appropriate korean adjectives; Irritate, Monotonous, stuffy and dryness. The result of this study may be used to evaluate the acoustic threshold level for indoor noise or a basis for specifying the desired acoustic environment of dwellings.

  • PDF

A field survey on the noise environment of apartment according to site location (주거단지 입지특성에 따른 소음환경 실태조사 - 도로변 아파트단지를 대상으로 -)

  • 박수빈
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 1994.05a
    • /
    • pp.11-17
    • /
    • 1994
  • The increase of road traffic niose in residential area has been considered to be a serious environmental problem to deteriorate a living condition. The understanding of noise environment in multiple family housing is needed for noise reduction. This study attempts to find out the characteristics of noise environment. For this purpose, the field survey has been carried out to investigate the noise environment(sound level, quality of sound) and the residents' responses(noiseness, annoyance) for noise environment based on 173 households living in 3 apartment compounds built in Pusan according to site location. The major findings are as follows : 1. The sound levels by road traffic noise were measured by dB(A) and dB(Lin). The sound levels were : 77.0dB(A), 86.6dB(Lin) in D-Apt, 73.3dB(A), 82.6dB(Lin) in K-Apt, and 59.1dB(A), 74.6dB(Lin) in M-Apt. Especially, the difference between dB(A) and dB(Lin) was very big in the cae of M-Apt with a barriers for traffic noise reduction. 2. The internal sound levels were shown the soudn attenuation by horizontal distance and by opening or shuting condition of windows.

  • PDF

A Study on the Core Noise Reduction Techniques of Power Transformers (전력용 변압기 철심소음 저감기술에 관한 연구)

  • Kweon, Dong-Jin;Koo, Kyo-Sun;Cho, Ik-Choon;Kim, Yoo-Hyun;Kim, Yung-Sig
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.1962-1969
    • /
    • 2008
  • According to the increase of power demand and expansion of downtown, it is necessary to install transformers additionally in operating substations and construct substations in residential area. But the public complaint is increased due to the transformer noise of the substation. KEPCO has used a vibration preventing pad, various soundproof walls and an encloser to transformers in outdoor substations, and a soundproof door, shutter and wind-path soundproof equipment in indoor substations to block the sound propagation of the transformers. But these noise reduction methods are not satisfied. It should be considered to reduce transformer noise itself. In this paper, we investigated core noise reduction techniques to develope a low noise transformer. The techniques to reduce core noise of the transformer are application of high permeability grain oriented silicon sheets, decrease of magnetic flux density of core, application of 6step-lap core stacking method, improvement of core binding method(binding addition, band fixing) and application of rubber damper in oder to reduce transmission of core vibration, etc.

A Study on Sample manufacturing and Performance Evaluation for Vibration Insulation Material of Noise Barrier for High-Speed Railway (고속철도구간 방음벽 제진재 시험제작 및 성능평가에 관한 연구)

  • Kim Soon-Cheol;Kang Jeong-Ok;Han Kwang-Seob;Jeon Byung-Chan;Han Jong-Moon
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.522-529
    • /
    • 2005
  • The commercial service of KTX from April 1st 2004 has realized that whole country has shrunk into half-day life zone and it opened the times of speed. However, some technical problems unexpected before service have been raised and, among them, the noise generation at train passing was claimed by the residents living nearby the track and it is often publicized by the broadcastings and newspapers. In case where the residential area is close to the track, the installation of noise barrier at trackside is the general measures for noise reduction on bridge section and earthwork section. In case of KTX project, such measures were actually taken without any exception; however, the noise level is still high. In this study, analysis for the reason of higher noise level in spite of which the noise barriers are being installed was carried out, the sample of insulation material effective for noise barrier was manufactured and the performance of the insulation material was evaluated to verify its effectiveness

  • PDF