• Title/Summary/Keyword: Residential Conditions

Search Result 536, Processing Time 0.022 seconds

A Study on Expanding Participation in and Raising Awareness of the Green Parking Project for Improvement of Parking Conditions in Urban Residential Areas (도시주거지 주차환경개선을 위한 녹색주차사업 참여확대 및 인식제고 방안)

  • Kim, Myo-Jung
    • Journal of the Korean housing association
    • /
    • v.26 no.1
    • /
    • pp.61-70
    • /
    • 2015
  • The purpose of this study was to provide information on how to expend participation in and raise awareness of the Green Parking Project. A survey was conducted for this study among two groups. One group consisted of 38 residents of the Green Parking Zone in Nam-gu, Ulsan, and the other group consised 129 residents with no experience with the Green Parking Project. For analysis, the frequency and means were calculated, and t-test, analysis of variance, and chi-square test were performed. The results showed, first, that general residents tended to think that parking on the street in front of one's house is a divine right, while residents living the Green Parking Zone thought that the street is a public space. Second, general residents regarded fences as means of security to protect their private property, while people living in the Green Parking Zone tended to think of their yards as semi-private spaces and allowed access to neighbors. Third, general residents had concerns about maintenance and administration fees, noise and dust, security of houses, and privacy. However, residents of the Green Parking Zone evaluated those conditions positively. Fourth, people who were well-informed about the Green Parking Project had low anxiety about security and invasion of privacy, results from the project. Therefore, effective public relations are very important for expanding participation and raising awareness.

Research of High Efficiency Integrated Reforming System Using Separated Reforming System (분리형 개질기를 이용한 고효율 일체형 개질기 개발에 관한 연구)

  • PARK, SANG-HYOUN;KIM, CHUL-MIN;SON, SUNG-HYO;JANG, SE-JIN;KIM, JAE-DONG;BANG, WAN-KEUN;LEE, SANG-YONG
    • Journal of Hydrogen and New Energy
    • /
    • v.29 no.1
    • /
    • pp.11-18
    • /
    • 2018
  • A high efficiency integrated reforming system for improving the efficiency of the 5 kW PEMFC system used as the back up power of building was studied. The separated reforming system consisted of three parts - A steam reformer with two stage concentric circular shape, a heat exchanger type steam generator and a CO shift reactor. Temperature and steam carbon ratio (SCR) were control variables during operation. The operating conditions were optimized based on the thermal efficiency of the steam reformer as reformate gas composition changes at different temperature. In experiments, water was fully vaporized in the steam generator up to SCR 3.5 and the maximum thermal efficiency was achieved at the operating temperature around $700^{\circ}C$ in the steam reforming reactor. With the results of the separated reforming system research, we improved the shape of high efficiency integrated reformer. The performance evaluation of the integrated reformer was based on optimized operating conditions in SCR 3.5. As a result, the developed integrated reforming system maintained an efficiency of 76% and constant performance over 3,000 hours.

A Study on the External Wall Heating Temperature Distribution According to Opening Upper Shading Installation and Length (개구부 상부 차양설치 및 길이에 따른 외벽 수열온도분포에 관한 연구)

  • Jung, Ui-In;Hong, Sang-Hun;Kim, Bong-Joo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.4
    • /
    • pp.339-345
    • /
    • 2020
  • This study used a real-scale model experiment to reproduce internal fires in residential buildings such as a multi-dwelling unit, in order to prevent damage caused by tens of thousands of fires witnessed each year and to take measures to cope with them. For experimental conditions, different opening sizes were applied to measure and analyze the heating temperature of the exterior wall. Results drawn are as follow : On top of this, the experimental conditions had whether to install shading and put a shading length differently, before measuring and analyzing the heating temperature of the exterior wall. Subsequent results were drawn as shown below. Based on the maximum temperature, the temperature was lowered as much as around 90℃ at 150mm, around 150℃ or over at 300mm and over 175℃ at 450mm. It also turned out that the difference in maximum temperature dropped by around 180℃ or over. This indicated that the shading installation works well in lowering flame temperature generated by fire spread of the exterior wall.

Selection of Capillary Tubes for HCFC-22 Alternative Fluids (HCFC-22 대체냉매의 모세관 선정)

  • Jung, D.S.;Kim, C.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.435-449
    • /
    • 1995
  • In this paper, pressure drop through a capillary tube is modeled to determine the length of a capillary tube for a given set of conditions. HCFC-22 and its alternatives, HFC-134a, R407B, and R410A are used as working fluids. The conditions on which the model is tested are as follows : condensing temperature; 40.0, 45.0, 50.0, $55.0^{\circ}C$, degree of subcooling;0.0, 2.5, $5.0^{\circ}C$, capillary tube exit condition;choked flow, capillary tube diameter;1.2~2.4mm, mass flow rate;5.0~50.0g/sec. The results justify the use of Stoecker's model which yields the results very close to the values in ASHRAE handbook. While McAdams' method yields much better results than Duckler's in calculating the viscosity of the fluid in 2-phase, the friction factor suggested by Stoecker seems to be the best for capillary tubes of large diameter used in residential air conditioners. For each refrigerant, 372 data with various variables are calculated by the model. The results show that capillary tube length varies very uniformly with changes in condensing temperature and degree of subcooling. Based on this fact, regression analysis is performed to determine the dependence of mass flow rate on the length and diameter of a capillary tube, condensing temperature, and degree of subcooling. Thus determined correlation yields a mean deviation of 2.36% for 1,488 data, showing an excellent agreement.

  • PDF

Performance of Heat Pumps Charged with R170/R290 Mixture (R170/R290 혼합냉매 적용 히트펌프 성능 평가)

  • Park, Ki-Jung;Lee, Cheol-Hee;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.9
    • /
    • pp.590-598
    • /
    • 2008
  • In this study, performance of R170/R290 mixtures is measured on a heat pump bench tester in an attempt to substitute R22. The bench tester is equipped with a commercial hermetic rotary compressor providing a nominal capacity of 3.5kW. All tests are conducted under the summer cooling and winter heating conditions of $7/45^{\circ}C$ and $-7/41^{\circ}C$ in the evaporator and condenser respectively. During the tests, the composition of R170 is varied from 0 to 10% with an interval of 2%. Test results show that the coefficient of performance (COP) and capacity of R290 are up to 15.4% higher and 7.5% lower than those of R22 for both conditions respectively. For R170/R290 mixture, the COP decreases and the capacity increases with an increase in the amount of R170. The mixture of 4%R170/96%R290 shows the similar capacity and COP as those of R22. For the mixture, the compressor discharge temperature is $16{\sim}30^{\circ}C$ lower than that of R22. There is no problem with mineral oil since the mixture is mainly composed of hydrocarbons. The amount of charge is reduced up to 58% as compared to R22. Overall, R170/R290 mixture is a good long term 'drop-in' candidate to replace R22 in residential air-conditioners and heat pumps.

To reduce carbon from residential architecture Research on energy-saving elements (주거건축에서 탄소를 줄이기 위한 에너지 절감 요소에 관한 연구)

  • Park, Jae-Hee
    • KIEAE Journal
    • /
    • v.9 no.5
    • /
    • pp.47-52
    • /
    • 2009
  • Currently, the environmental issue is of great urgency and sensitivity to the future of our planet. Global warming caused by increased CO2 concentration has an alarming impact on the earth's fragile environment. Droughts throughout the world are causing crop failures. Wildfires now burn with far greater rage. Melting ice caps and glaciers are causing floods. Sea levels are rising. Warm unseasonable winters are threatening our fragile eco-systems. Global warming is no longer a theory; it is an obvious fact we are confronted with every day, and the only way we can prevent it is to take action now. The need to reduce CO2 emissions and try to become carbon neutral is of national importance and leadership. We have become so reliant on fossil fuels that nearly everything we do generates CO2 emissions; from our modern farming practices to transport, to the electricity used to turn on a light, boil water in a kettle or cook our meals. A reduction of 50% of CO2 emissions can easily be achieved by decreasing the energy amount used. We tracked the carbon footprint throughout the electricity and heating energy use in homes and confirmed the amount of carbon emissions according to its consumptions. In order to reduce the carbon generation from housing constructions, such as Passive House concept of buildings or low energy buildings, we must adjust its applications best fit to our conditions. And technical elements should be applied to improve our conditions, and the methodology should be actively sought. Most of all, each individual's recongnition who uses these elements is more important than any other solutions.

Feng Shui Theory Analysis Of Living Environment Layout of Fortune - Focused on Eunpyeong New Town - (풍수이론으로 바라 본 주거환경의 길흉형국 - 은평뉴타운을 중심으로 -)

  • Xu, Zhong-Hua;Sung, Jong-Sang
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.34 no.2
    • /
    • pp.55-62
    • /
    • 2016
  • In this paper, Fengshui Theory Analysis Eunpyeong-New Town. The analysis frame is man and nature integrated, suit one measures to local conditions, analysis of macro environment site selection, analysis of micro environment site selection, analysis of traffic lines, orientations of residential analysis. The result is as follows: The analysis of the macro environment site selection of Eunpyeong-New Town at Northwest Mountain shape is open, so in the winter exposure of the northwest there is wind. Therefore, according to Fengshui there is a bad pattern formation. Analysis of the macro environment site selection has four animal frames seperated into two districts. The result is district one has "bad" ground. District two uses Bibo to restore small brooks so the formation has "good" ground. Finally, we use Fengshui of Bibo to propose solutions.

A Study on Architectural Characteristics of the Newly Built Hanok in Seoul Since 2000 - Focused on the Kan Composition - (2000년 이후 서울의 신축한옥에서 보이는 건축적 특징 - 칸 구성을 중심으로 -)

  • Kim, SungHa;Jeon, BongHee
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.9
    • /
    • pp.109-117
    • /
    • 2019
  • Since 'Hanok Expanse Support' has been started in Seoul, its target was expanded from renovation to new construction and from 'Hanok District' to all area in Seoul. The newly built hanok with Hanok Expanse Support had to follow the standards about the form of the hanok and adapt to modern lifestyle. However, the newly built hanok were planned with 'kan' since it retained the traditional wooden structure. So their composition of kan were considered to be influenced by the standards of each district and modern lifestyle. Therefore the aim of this study is to understand the architectural characteristics of newly built hanok in Seoul since 2000 focusing on the kan composition. Because of the differences in site conditions and the district unit plan, newly built hanok in Hanok District have more limited changes than Other District. However, kan is composed variously in horizontal and vertical ways to make the most space according to site conditions and most of the newly built hanok have opened courtyard rather than closed courtyard layout. With kan composition in various directions and kan added under the eaves, kan is highlighted in form. On the other hand, the composition of kan as an interior spatial element has changed and weakened because the lifestyle has changed compared to the traditional hanok and the 20th century urban hanok. Also the regular kan composition of Mom-chae and Nalgae-chae has changed. And kan is divided regardless to the wooden structure. Also, with the added kan under the eaves the main kan is dismantled inside. This paper indicates that although there is an undeniable premise that the case is restricted to hanok received Hanok Expanse Support on the condition of following the standards of the form of hanok, it is a part of the transitional changes that hanok is experiencing.

Fuel Characteristics of Pitch Pine and Mongolian Oak Pellets Fabricated with Coffee Waste and Used Frying Oil as an Additive Using a Pilot-scale Flat-die Pellet Mills (식품부산물인 커피박과 폐식용유를 첨가제로 사용하여 파일럿 규모의 평다이 성형기로 제조한 리기다소나무 및 신갈나무 펠릿의 연료적 특성)

  • Yang, In;Jin, Xuanjun;Han, Gyu-Seong
    • New & Renewable Energy
    • /
    • v.18 no.3
    • /
    • pp.23-31
    • /
    • 2022
  • This study evaluated the potential of coffee waste (CW) and used frying oil (UFO) as an additive in the production of pitch pine (PIP) and Mongolian oak (MOK) pellets. Ash contents obtained from CW and UFO were 0.5% and <0.1%, respectively. The calorific values of UFO (31.4 MJ/kg) and CW (26.3 MJ/kg) are higher than PIP (20.6 MJ/kg) and MOK (19.1 MJ/kg). For pellets fabricated using a pilot-scale flat-die pellet mill, regardless of fabricating conditions, moisture content (MC) and bulk density of PIP and MOK pellets satisfied the A1 wood pellet standard for residential and small-scale commercial uses, as designated by the National Institute of Forest Science (NIFOS) of the Republic of Korea. When CW was used as an additive, durability of PIP pellets made with 12%-MC sawdust and MOK pellets increased. The optimal conditions for producing PIP and MOK pellets could be by adding 20 mesh CW as an additive and the using of 12%-MC sawdust. However, durability of PIP pellets and ash content MOK pellets did not satisfy the A1 wood pellet standard of NIFOS. Thus, further research is needed to improve the properties of wood pellets with additives.

A STUDY ON THE TEMPERAMENTAL CHARACTERISTICS OF KOREAN CHILDREN USING TODDLER TEMPERAMENT SCALE (걸음마기 기질평가척도를 이용한 한국 아동의 기질 특성 연구)

  • Choi, Sung-Ku;Hong, Sung-Do;Son, Jung-Woo
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.13 no.1
    • /
    • pp.163-176
    • /
    • 2002
  • Objectives:This study was designed to investigate the temperamental characteristics and the differences of temperamental characteristics in Korean children according to the sociodemographic and family environment factors using Toddler Temperament Scale(TTS). Methods:The samples consisted of 1,175 children who were attending twenty-five Samsung Child Care Centers nationwide. Both Korean version of TTS and child developmental questionnaire(designed by the Department of Psychiatry, Samsung Medical Center) were distributed to the parents of these children. Score of 9 temperamental categories was determined using the result of TTS, and determination of 5 temperamental clusters was conducted by the Fullard's criteria. Statistical analyses were performed according to the sex, birth order, existence of siblings, residential city, residential province, marital state of child's parents, and parental relationship to compare the scores of temperamental categories and the distribution of temperamental clusters. Results:The distribution of temperamental clusters was as follows;Easy 35.8%, Intermediate Low (IL) 33.1%, Intermediate High(IH) 11.1%, Slow-To-Warm-Up 6.3%, and Difficult 13.6%. Some of 9 temperamental categories were statistically different according to the sex, birth order, existence of siblings, residential city, residental province, marital state of child's parents, and parental relationship. From the viewpoint of 5 temperamental clusters, there were statistically more Easy and less Difficult children in good relation between each parent(p=.022). In spite of no statistical significance, the children in conditions of first-born, non-existence of siblings, middle or small residential city, Chung-Cheong province, married state of parent had a tendency to be easier to care. Conclusions:The toddler temperamental characteristics of Korean children showed some differences in several sociodemographic and family environment factors. We could confirm that the 'Goodness of Fit' was very important in child temperament.

  • PDF