• Title/Summary/Keyword: Residential Conditions

Search Result 529, Processing Time 0.026 seconds

A study on the management of the cognitive health design pilot projects applied to residential areas (주거지에 적용된 인지건강디자인 시범사업의 유지관리 실태 연구)

  • Kim, Hyunju;Lee, Seungji
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.4
    • /
    • pp.41-50
    • /
    • 2021
  • Purpose: This study is aimed at the case of the cognitive health design pilot projects promoted by the Seoul Metropolitan Government since 2014 in terms of design to solve social problems in accordance with the aging population of our society. The purpose of this study is to analyze the maintenance and management of the projects and to suggest implications for the promotion and expansion of sustainable cognitive health design in the future. Method: It set the analysis frame by dividing management into maintenance-damage-demolition for the spatial types and spatial elements suggested in the Seoul Cognitive Health Guidelines. And it analyze the actual conditions of four pilot projects based on the field survey. Results: First, the ratio of damage and demolition was higher than maintenance. Second, designs and techniques with low durability were applied. Most of the cases where floor marks were applied to the external environment were lost or difficult to recognize, and their functions were limited due to storage of goods and parking of vehicles and motorcycles. Third, there was a large variation according to the type of residence. The project contents that can be applied to the low-rise residential area were also limited, and more elements were demolished than in the apartment type. Implications: First, it should limit project contents of space types and space elements that can be maintained even over time. Second, it should seek sustainable design and technical solutions. Third, it should seek alternatives to cognitive health design in low-rise residential areas where a large number of elderly people live.

Design and Implementation of Room Finding Application using VR

  • Park, Eunju;Kim, Juryeong;Lim, Hankyu
    • Journal of Multimedia Information System
    • /
    • v.4 no.3
    • /
    • pp.151-156
    • /
    • 2017
  • As Internet services have spread centering on mobiles, diverse services used in everyday life have become mobile services. For humans, residential spaces have significant implications as physical and psychological environments. Therefore, being provided with accurate information on the room that must be sought to find out the residential space wanted by the user can be said to be an important element of real estate apps. However, when buying real estate, people prefer searching for information using mobiles and verifying the information by visiting the real estate firsthand due to increases in damage due to false offerings. This way approaches as inconvenience in cases where the buyer lives far away or if the conditions are not suitable. Therefore, in the present study, a 'room finding application using VR' was designed and implemented using virtual reality (VR) used for diverse purposes. VR is a technology that provides the user with the sense of presence as if the user is actually present in the space. It was used in the present study as a means to provide more accurate information. The use of the application designed and implemented in the present study is expected to reduce false offerings information at least slightly so that users can be provided with more accurate information on the real estate of interest.

A Study on the Evaluation of the Dwelling Environment in the Types of Residential Area (도심지역의 거주환경평가에 관한 연구 - 대구 도심 지역 거주자를 대상으로 -)

  • 신소영
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 1994.05a
    • /
    • pp.29-36
    • /
    • 1994
  • The purpose of this study is to suggest the basic design elements for dwelling environment planning of downtown in Taegu.The evaluation of the dwelling environment should be approached from the satisfaction and the cognitive of the residents, that are based on their desire and various values on the conditions of residential area. This paper concerns the satisfaction and the congnitive image structure of the residents in the various dwelling types, from which design elements for dwelling environments can be derived. The results are as folIows: 1) The analysis on the satisfaction of dwell ins environment shows lots of displeasure about the lack of open-spaces and the housing low-quality, neighborhood in Mun-hwa, Korean style housing and the low-rise apartment areas. In order to make the variety types of dowelling in downtown district, the improvement of housing qualities and the expantion of the urban facilities for the open-spaces and communities are need. 2) The design elements of dwelling environments in downtown find out the important planning elements for urban design. The evaluation of the cognitive image structures about the safety and affection should be considered in design for urban dwelling areas.

  • PDF

Crime Prevention Analysis and Design Guideline of the Elementary School in Urban Residential Blocks (주거지 내 초등학교의 범죄안전성 분석과 계획방안)

  • Kim, Lee-Won;Yang, Woo-Hyun
    • Journal of the Korean housing association
    • /
    • v.22 no.6
    • /
    • pp.71-82
    • /
    • 2011
  • Recently the crime against elementary school students has been rapidly increasing. Under these circumstances, this study is to analyze the basic principles of Crime Prevention Through Environmental Design (CPTED) for the elementary school in urban residential area, and suggest some planning and design guidelines. Among 59 elementary schools in Pyongchon, Bundang, and Pangyo new towns, 11 distinctive schools were selected for analysis study. School cases were investigated comparatively from the viewpoints of visibility, securing of observers, activity support and reinforced territoriality on the basis of theoretical crime prevention concepts. The analysis adopts various methods including theoretical research, field study, observation, and examination of plan. Some of findings of this analysis are as follows. Most of schools rely on the mechanical and physical devices such as CCTV, gate control, or walls, which are considered to be quite passive measures and ineffective for the crime prevention. Other effective methods such as offering school facilities to the public or public space sharing with surrounding residents, for the protection of crimevulnerable students by public eyes. Therefore, in order to prevent crimes effectively, it is urgently required to analyze the environments around and in the school, and to improve physical conditions on the basis of CPTED principles.

Self-sustainable Operation of a 1kW class SOFC System (1kW급 고체산화물 연료전지 발전시스템 자열운전)

  • Lee, Tae-Hee;Choi, Jin-Hyeok;Park, Tae-Sung;Yoo, Young-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.57-60
    • /
    • 2008
  • KEPRI has studied planar type SOFC stacks using anode-supported single cells and kW class co-generation systems for residential power generation. A 1kW class SOFC system consisted of a hot box part, a cold BOP part and a water reservoir. A hot box part contains a SOFC stack made up of 48 single cells and ferritic stainless steel interconnectors, a fuel reformer, a catalytic combustor and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation. A cold BOP part was composed of blowers, pumps, a water trap and system control units. When a 1kW class SOFC system was operated at $750^{\circ}C$ with hydrogen after pre-treatment process, the stack power was 1.2kW at 30 A and 1.6kW at 50A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about 1.3kW with hydrogen and 1.2kW with city gas respectively. The system also recuperated heat of about 1.1kW by making hot water.

  • PDF

Field study of 5kW class PEMFC system (5kW급 고분자전해질 연료전지 시스템 실증연구)

  • Lee, SooJae;Choi, Dae Hyun;Jun, HeeKwon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.87.1-87.1
    • /
    • 2011
  • The residential Fuel Cell system has high efficiency of 85% with transferring natural gas to electrical power and heat, directly and it is a friendly environmental new technology in that $CO_2$ emission can reduce 40% compared with conventional power generator and boiler. The residential fuel cell system consists of two main parts which have electrical and hot storage units. The electrical unit contains a fuel processor, a stack, an inverter, a control unit and balance of plant(BOP), and the cogeneration unit has heat exchanger, hot water tank, and auxiliaries. 5kW class fuel process was developed and tested from 2009, it was evaluated for long-term durability and reliability test including with improvement in optimal operation logic. Stack development was crried out through improvement of design and evaluation protocol. Development of system controller was successfully accomplished through strenuous efforts and original control logic was optimized in 5kW class PEMFC system. In addition, we have been focused on development of system process and assembly technology, which bring about excellent improvement of reliability of system. The 5kW class PEMFC system was operated under dynamic conditions for 1,000 hours and it showed a good performance of total efficiency and durability.

  • PDF

Prediction of Concrete Slab Acceleration and Floor Impact Noise Using Frequency Response Function (주파수 응답함수를 이용한 콘크리트 슬래브 가속도 및 바닥충격소음 예측)

  • Mun, Dae-Ho;Park, Hong-Gun;Hwang, Jae-Seung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.6
    • /
    • pp.483-492
    • /
    • 2014
  • Uncomfortable feelings of occupants by indoor floor impact noise in a residential building are not accurately represented by the floor impact noise from a standard impact source. It is due to the characteristics of standard impact sources, which are different from the impact forces produced by occupants. It varies significantly by impact source, and it is not easy to be replicated for testing. As a result, the indoor floor impact noise under different acoustic conditions cannot be directly compared. Using frequency response function(FRF), which represents the input-output relationships of a dynamic system, it is possible to examine the characteristics of the system. Especially, FRF can predict the response of a linear dynamic system subjected to various excitation. To determine the relationship between impact force and the corresponding response of dynamic system in residential building, the acceleration response of a concrete slab and the floor impact noise in the living room, produced by bang-machine and rubber-ball excitation, were measured. The test results are compared to the estimates based on FRF and impact force spectrum.

VLD technique for MEAs performance enhancement (MEA의 장기 성능 향상을 위한 VLD 기술 개발)

  • Lim, Sang-Jin;Kim, Hyoung-Juhn;Cho, Eun-Ae;Lee, Sang-Yeop;Lim, Tae-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.494-497
    • /
    • 2006
  • For commercialization of polymer electrolytemembrane fuel cell (PEMFC), durability of membrane electrode assemblies (MEAs) has to be improved. Especially, long-term stability of MEA is one of the most important issues for frequent shut-down and start-up processes of PEMFC. The degradation of MEA could be attributed to chemical attack of hydrogen peroxide radicals that are formed at high cell voltages without any special treatment to remove residual hydrogen from anode gas channel after shut-down of the fuel cell. In this study, we investigated the long-term stability of MEA under different on/off operation conditions. Residential hydrogen gas was removed from the anode flow channel by purging air or nitrogen. Also, a dummy resistance was applied to the fuel cell to exhaust residential hydrogen at the anode. In these cases, MEA showed much more stable durability. Electrochemical characteristics of the fuel cell were measured byrepeating the on/off cycles with the hydrogen removal processes. Also, degradation of MEA components was examined by SEM, TEM and XRD analyses.

  • PDF

Residential Satisfaction Level of Group Homes for the Elderly Living Alone in Rural Areas (농촌지역 독거노인 생활공동체 거주만족도)

  • Jeong, In-Soo;Park, Sun-Hee;Yun, Hye-Rim
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.14 no.1
    • /
    • pp.9-19
    • /
    • 2012
  • The object of this study is to investigate the satisfaction level of group homes for the elderly living alone in rural areas. Sixty-four elderly people, living alone, were selected from ten regions operated by the Gimje city council in Jeonlabuk-do, and then a survey was conducted during January 17 to 26 in 2011. The results of the investigation are as follows: first, roughly 90.6 percent of the participants responded that they were satisfied with cohabitation. Second, average point of satisfaction was going to bed together, which is 4.39, also each unit in all the ten regions was recorded above 4.00. Third, the satisfaction of eating together averaged highly at 4.37. Fourth, 95 percent of them were satisfied with the conditions of the residential space. Fifth, the satisfaction with the amenities, such as electricity, phone, heating and sanitation, averaged 96.9 and 98.4 percent each, which was rated highest. Through analytical research, elderly people who live in 'group homes' are satisfied with their lives. It is thought that this 'group home' can play the role of an alternative family better than existing 'senior citizen centers' and 'welfare centers for the elderly'. The study means that 'group homes' in rural areas could be established successfully.

Refined damage prediction of low-rise building envelope under high wind load

  • Pan, F.;Cai, C.S.;Zhang, W.;Kong, B.
    • Wind and Structures
    • /
    • v.18 no.6
    • /
    • pp.669-691
    • /
    • 2014
  • Since low-rise residential buildings are the most common and vulnerable structures in coastal areas, a reliable prediction of their performance under hurricanes is necessary. The present study focuses on developing a refined finite element model that is able to more rigorously represent the load distributions or redistributions when the building behaves as a unit or any portion is overloaded. A typical 5:12 sloped low-rise residential building is chosen as the prototype and analyzed under wind pressures measured in the wind tunnel. The structural connections, including the frame-to-frame connections and sheathing-to-frame connections, are modeled extensively to represent the critical structural details that secure the load paths for the entire building system as well as the boundary conditions provided to the building envelope. The nail withdrawal, the excessive displacement of sheathing, the nail head pull-through, the sheathing in-plane shear, and the nail load-slip are found to be responsible for the building envelope damage. The uses of the nail type with a high withdrawal capacity, a thicker sheathing panel, and an optimized nail edge distance are observed to efficiently enhance the building envelope performance based on the present numerical damage predictions.