• 제목/요약/키워드: Reset waveform

검색결과 49건 처리시간 0.027초

A new ramp reset waveform for reducing reset period using address pulse of AC-PDP

  • Kim, Gun-Su;Choi, Hoon-Young;Lee, Seok-Hyun;Kim, Jun-Hyoung;Mim, Byoung-Kuk
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.609-612
    • /
    • 2002
  • A new reset waveform is proposed for reducing the reset period. A square pulse is applied to the address electrode while reset pulse ramps and before a discharge between the sustain electrodes occurs. The square pulse induces a discharge between the address electrode and the X electrode, and the induced wall charge is opposite to the applied ramp pulse. Thus, the next discharge between the sustain electrodes becomes weaker. The weaker discharge lowers background luminance and improves contrast ratio. Thus, the new reset waveform can reduce ramp up time in the ramp reset waveform The experimental results show that the ramp up time can be reduced by about 90% compared with the conventional ramp reset waveform.

  • PDF

ac PDP에서 Addressing 특성개선을 위한 Negative Ramp Slope이 적용된 Reset Pulse에 관한 연구 (The new reset pulse used negative ramp slope for improving the addressing characteristic in ac PDP)

  • 최혜림;정선욱;강정원
    • 반도체디스플레이기술학회지
    • /
    • 제5권2호
    • /
    • pp.11-14
    • /
    • 2006
  • A new reset waveform with negative ramp pulse is proposed. Conventional reset waveform applied to the commercial PDP uses a positive ramp pulse. The reset waveforms, especially focused on ramp area, were examined with 2 dimensional fluid code. The proposed negative reset waveform showed much lower ignition voltage ($\sim$70V) as compared with the conventional reset waveform. When the negative ramp pulse was applied, all of the positive-charged ions are collected on the scan electrode. It is found that the ignition voltage of reset discharge due to the negative ramp pulse became lower than that of positive ramp discharge.

  • PDF

Characteristic of a Negative Driving Waveform in ac PDPs

  • Kang, Jung-Won
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.97-100
    • /
    • 2009
  • A negative waveform was studied to improve the driving characteristics of reset and address periods in ac PDP. Comparative experiments between negative and conventional positive waveforms were performed with 42-inch XGA PDP module. The negative waveform showed lower breakdown voltage than the conventional positive waveform in reset period. Due to its weak and stable discharge during reset period, the contrast ratio was improved by decreasing the black luminance. During address period, the discharge time-lag was measured. The formative time lag ($=T_f$) of negative waveform was improved about 22.8% than $T_f$ of conventional positive waveform.

  • PDF

온도 적응형 PDP RESET 파형 발생회로의 개발 (Reset Waveform Generation Circuit Adapting To Temperature Change)

  • 신민호;김철우
    • 전력전자학회논문지
    • /
    • 제10권6호
    • /
    • pp.587-591
    • /
    • 2005
  • AC PDP의 구동파형은 Reset 구간에서 명암비를 높이고 화질향상을 위해서 전압파형을 서서히 증가시키고 또 감소시키는데, 이 전압파형의 기울기와 크기가 온도와 더불어서 PDP의 화질과 관련이 있다. 그래서 본 논문에서는 Reset 구간에서 Y 전극에 인가하는 램프파형의 setup 및 setdown 구간에서의 기울기와 -Vy전압을 온도에 따라서 가변함으로써, 주위의 온도가 상온에서 저온이나 고온으로 변화하여도 PDP의 화질이 영향을 받지 않고 최상으로 유지하게 하는 온도 적응형 RESET 파형 발생회로를 제안하였다.

Comparative Studies between the Negative Waveform and the Conventional Positive Waveform during Reset Period.

  • Eom, Cheol-Hwan;Lim, Hyun-Muk;Lee, Jun-Young;Kong, Byoung-Goo;Park, Hyun-Il;Moon, Sung-Hak;Kang, Jung-Won
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.388-391
    • /
    • 2008
  • A new reset waveform with negative ramp pulse was proposed. Comparative experiments between the negative and positive waveforms were performed. During reset period, IR distributions and luminance of black and white conditions were measured with the 42-inch XGA PDP module. The negative waveform improved contrast ratio about 15.4 ~ 22.5 % than the positive waveform by lowing the black luminance in reset period. Z bias (= Vbb) of the positive waveform was 27 V higher than the negative waveform.

  • PDF

교류형 플라즈마 디스플레이에서 선택적 초기화 방법에 의한 기입 방전 특성의 영향 (Effect of Address Discharge Characteristics by Selective Reset Method in AC Plasma Display Panel)

  • 조병권
    • 한국전기전자재료학회논문지
    • /
    • 제25권12호
    • /
    • pp.1004-1008
    • /
    • 2012
  • The effect of address discharge characteristics by selective reset method is investigated to prevent the weakness of address discharge in the middle of a TV-field without increase of the black luminance. To reduce black luminance in AC PDP usually, the first subfield during one TV frame adopted the conventional rising ramp-reset waveform, whereas the other subfields adopted the subsidiary reset waveform without rising ramp type. As the wall charge for the address discharge was accumulated by only the rising ramp waveform during the first reset period, the wall charge on three electrodes was disappeared as time passed and the address discharge would be weakened in the rear subfields. To prevent a reduction of the address discharge characteristics without decrease the black luminance, the modified rising ramp reset waveform was adopted only in the sixth subfield. As a result, a modified driving method could improve the address discharge characteristics compared with selective reset driving scheme with almost the same black luminance.

ac PDP에서의 Reset과 Address 구간에서 Negative Waveform특성에 관한 연구 (A Study of Negative Waveform in ac PDP during Reset and Address Periods)

  • 엄철환;강정원
    • 반도체디스플레이기술학회지
    • /
    • 제8권1호
    • /
    • pp.27-31
    • /
    • 2009
  • A characteristic of new waveform, called a negative waveform, was studied during reset and address periods. IR distribution, black luminance and time delay were measured to compare the negative waveform with the conventional positive waveform. Based on the analysis of IR measurement, the negative waveform could accumulate more wall charges than the positive waveform. Also the black luminance of negative waveform was lower than that of positive waveform under the same bias and ramp-slope conditions. During address period, the discharge time lag was measured. The negative waveform was showed 0.25 us faster formative time lag and 0.1 us faster average time lag than those of positive waveform.

  • PDF

AC PDP에서 2차원 수치해석을 이용한 Ramp Reset 구동파형에 따른 방전 특성 분석 (The Discharge Characteristic Analysis of a Ramp Reset Waveform Using a 2-Dimensional Numerical Simulation in AC PDP)

  • 박석재;최훈영;서정현;이석현
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권12호
    • /
    • pp.606-615
    • /
    • 2004
  • The discharge characteristics of a ramp reset waveform in the alternating current plasma display panel(ac PDP) were studied using a 2-dimensional numerical simulation. We analyzed the wall charge variation during the reset discharge, address discharge and sustain discharge adopting a ramp reset waveform. Then we investigated the principal parameters for a successful discharge. In this paper, we suggest a new parameter, printing particles' density and its effects on the stability of the ramp discharge. The maximum current flows of the three electrodes during the ramp reset period were decreased with the increase in the priming particles's density which was explained with the wall charge characteristics and the current flow characteristics obtained by a 2-D simulation.

A Modified Ramp Reset Waveform for High Contrast Ratio in AC PDPs

  • Kim, Jae-Sung;Yang, Jin-Ho;Ha, Chang-Hoon;Whang, Ki-Woong
    • Journal of Information Display
    • /
    • 제3권4호
    • /
    • pp.13-18
    • /
    • 2002
  • In general, the background light that is produced during the reset period deteriorates the dark room contrast ratio in AC PDP. In this paper, we propose a modified ramp reset pulse that can reduce the background light to an imperceptible level. In the new reset waveform, the discharges between the scan and sustain electrodes are minimized by applying a positive bias voltage to the sustain electrode and only the weak discharges between the scan and address electrodes are found to occur during the reset period. We also adopted the MgO coated phosphor layer to improve the address voltage margin that was reduced when the bias voltage in the modified ramp reset waveform was applied. As a result, the address voltage margin of 45 V which is the same level of the conventional method was ortained and the dark room contrast ratio was improved up to 7500 : 1.

AC PDP의 Reset 기간 단축을 위한 새로운 구동방식에 관한 연구 (A New Method to Reduce Reset Period in AC Plasma Display Panel)

  • 이상현;박정후
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권10호
    • /
    • pp.517-521
    • /
    • 2001
  • The voltage controlled ramp(VCR) waveform has recently been introduced in the reset period prior to addressing for plasma display. However, this method shows the oscillation of gap voltage when the ramp rate is increased in order to reduce reset period. In this paper a current controlled ramp(CCR) waveform method is suggested. This method can suppress the oscillation of gap voltge under the condition of shorter ramp time. Moreover, the reset time can be reduced about 30% compared with VCR method under the same background luminance.

  • PDF