• Title/Summary/Keyword: Research method

Search Result 65,387, Processing Time 0.077 seconds

A Study on Idea Conception Method of Creative Fashion Design -Focused on NM Method (T type) & Synetics- (크리에이티브 패션디자인 발상법 연구 -NM법(T형)과 시네틱스를 중심으로-)

  • Im, Miji;Park, Juhee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.1
    • /
    • pp.71-83
    • /
    • 2017
  • This research suggests a new idea conception method for creative thinking to develop a creative fashion design. The common characteristics of the design area, the unique characteristics of the fashion design, and idea conception method for creative thinking were analyzed and reviewed to develop a creative fashion design research model. Based on this, the fashion design research model was planned through an attempt to graft a new idea conception method on an existing method to utilize the advantage of it suitable for fashion design characteristics and designated as an idea conception method for a creative fashion design research model. We developed 10 designs with a full awareness of the research model steps; subsequently, the effectiveness was confirmed through the evaluation phase of the research model that utilized the idea conception method. This research has significance in that the research model utilizing idea conception method that rarely addressed in precedent research was developed with the idea conception method as a research subject by drawing the characteristics for an idea conception of fashion design and new approach was tried that emphasized the advantages of the existing method.

A Study of Simple α Source Preparation Using a Micro-coprecipitation Method

  • Lee, Myung Ho;Park, Tae-Hong;Song, Byung Chul;Park, Jong Ho;Song, Kyuseok
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.11
    • /
    • pp.3745-3748
    • /
    • 2012
  • This study presents a rapid and simple ${\alpha}$ source preparation method for a radioactive waste sample. The recovery of $^{239}Pu$, $^{232}U$ and $^{243}Am$ using a micro-coprecipitation method was over 95%. The ${\alpha}$-peak resolution of Pu and Am isotopes through the micro-coprecipitation method is enough to discriminate the Pu and Am isotopes from other Pu and Am isotopes. The determination of the Pu and Am isotopes using the micro-coprecipitation method was applied to the radioactive waste sample, so that the activity concentrations of the Pu and Am isotopes using the micro-coprecipitation method in the radioactive waste sample were similar to those using the electrodeposition method.

Clothing and Cultural Approach : The Importance of Qualitative Method (의복과 문화적 접근: 질적 연구 방법의 중요성)

  • 김현식
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.4
    • /
    • pp.510-520
    • /
    • 2000
  • Despite the important of qualitative research method, little is used to understand dress and culture in Korea. This study proposed qualitative research method to understand deeply cultural aspects of dress. The articles which were selected from J. of Korean Society of Clothing and Textiles, The Korean Society of Costume, Clothing and Textiles Research Journal, Home Economics Research Journal, published master's thesis and doctoral dissertation, and interdisciplinary articles were analyzed from 1977~1999. Based on results of the analysis of articles, it was found that qualitative research method was appropriate to understand dress and culture. Many articles were dealt with non-western culture. However, the use of qualitative research method is very well suited to help the researcher understand concepts that are deeply embedded in western culture. Implications pertain to researcher in the area of human behavior and marketing. The importance of dependability and credibility was discussed in qualitative research method.

  • PDF

Automatic proficiency assessment of Korean speech read aloud by non-natives using bidirectional LSTM-based speech recognition

  • Oh, Yoo Rhee;Park, Kiyoung;Jeon, Hyung-Bae;Park, Jeon Gue
    • ETRI Journal
    • /
    • v.42 no.5
    • /
    • pp.761-772
    • /
    • 2020
  • This paper presents an automatic proficiency assessment method for a non-native Korean read utterance using bidirectional long short-term memory (BLSTM)-based acoustic models (AMs) and speech data augmentation techniques. Specifically, the proposed method considers two scenarios, with and without prompted text. The proposed method with the prompted text performs (a) a speech feature extraction step, (b) a forced-alignment step using a native AM and non-native AM, and (c) a linear regression-based proficiency scoring step for the five proficiency scores. Meanwhile, the proposed method without the prompted text additionally performs Korean speech recognition and a subword un-segmentation for the missing text. The experimental results indicate that the proposed method with prompted text improves the performance for all scores when compared to a method employing conventional AMs. In addition, the proposed method without the prompted text has a fluency score performance comparable to that of the method with prompted text.

기술군집분석을 활용한 전략적 연구영역 도출

  • 이용길;이세준;박성배;원유형
    • Journal of Technology Innovation
    • /
    • v.10 no.1
    • /
    • pp.22-37
    • /
    • 2002
  • The importance of selecting the strategic research field is increasingly emphasized by research manager and technology policy-maker in perspective of the strategic allocation of R&D resources, employing the R&D personnel, and formulating technology policy. Among various methods for selecting the strategic research field, it is, however, very difficult to find the method that involves the path-dependant trend, and interdisciplinary nature of technology development. This study suggests modified technology cluster analysis (TCA) as a method for selecting strategic research field in order to include the recent technology trend in quantitative approach. TCA is the method that groups the near technologies of which the innovation pattern is similar. TCA model can be a very necessary method for multidisciplinary government research institutes (GRIs) which conduct multi research field with forward oriented positioning. It is more difficult for them to select the strategic research field mainly due to their diversity and intangibility of research scope. In this study, we applied this method to Korea Institute of Science and Technology (KIST) which represents the most adequate research institute in terms of research diversity and forwardness. As a result of the application, we found that seven main technology groups come from TCA analysis, coincide with the technology topics of KIST's recent R&D planning. Even though this method designed for multidisciplinary research institutes, but it also can be used for establishing the research strategy of other (private or public) Research Institute which have the similar mission and scope of research.

  • PDF

A Study on the Research of Analytical Method for 1,4-Dioxane in Water (1,4-Dioxane의 분석방법 연구)

  • Park, Sun-Ku;Kim, Tae-Ho;Rim, Yeon-taek;Myung, Nho-Il
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.6
    • /
    • pp.549-563
    • /
    • 2005
  • The study was carried out to develop and standardize the analytical method of 1,4-dioxane in water. The National Institute of Environmental Research in Korea has monitored for 1,4-dioxane in water since 1998 and it has been detected in environmental water occasionally. But the environmental pollution and analytical method in water is not well known over the world. The trace analytical method at low-${\mu}/L$ level is prerequisite in order to evaluate the residue of 1,4-dioxane in water. Evaluation of the method was demonstrated by comparing and analyzing with liquid-liquid extraction, solid-phase extraction and purge & trap technique. As a result of experiment by standard solutions and raw samples, the precision and accuracy for three methods were obtained within error rate of about 10%. Therefore, three methods were standardized as official monitoring method in Korea. Also, a convenient and simple liquid-liquid extraction method for the analysis of 1,4-dioxane in water was developed by combined with gas chromatography/mass spectrometry and applied to the water samples in Korea

Sea fog detection near Korea peninsula by using GMS-5 Satellite Data(A case study)

  • Chung, Hyo-Sang;Hwang, Byong-Jun;Kim, Young-Haw;Son, Eun-Ha
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.214-218
    • /
    • 1999
  • The aim of our study is to develop new algorism for sea fog detection by using Geostational Meteorological Satellite-5(GMS-5) and suggest the techniques of its continuous detection. So as to detect daytime sea fog/stratus(00UTC, May 10, 1999), visible accumulated histogram method and surface albedo method are used. The characteristic value during daytime showed A(min) > 20% and DA < 10% when visble accumulated histogram method was applied. And the sea fog region which detected is of similarity in composite image and surface albedo method. In case of nighttime sea fog(18UTC, May 10, 1999), infrared accumulated histogram method and maximum brightness temperature method are used, respectively. Maximum brightness temperature method(T_max method) detected sea fog better than IR accumulated histogram method. In case of T_max method, when infrared value is larger than T_max, fog is detected, where T_max is an unique value, maximum infrared value in each pixel during one month. Then T_max is beneath 700hpa temperature of GDAPS(Global Data Assimilation and Prediction System). Sea fog region which detected by T_max method was similar to the result of National Oceanic and Atmosheric Administration/Advanced Very High Resolution Radiometer (NOAA/AVHRR) DCD(Dual Channel Difference). But inland visibility and relative humidity didn't always agreed well.

  • PDF

Performance Analysis of Acquisition Methods for DGPS Reference Receiver under Noisy Environment

  • Park, Sang-Hyun;Cho, Deuk-Jae;Suh, Sang-Hyun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.107-112
    • /
    • 2006
  • The previous acquisition method of GPS receiver for reference station adopts not only the coherent integration method but also the non-coherent integration method in order to enhance sensitivity under noisy environment. However, under noisy environment, the previous GPS signal acquisition method causes the non-coherent integration loss which is a major factor among losses that can be caused during GPS signal acquisition. The non-coherent integration loss also increases with the strength of the received noise. This paper has intention of analyzing the performance of the GPS signal acquisition method proposed to effectively enhance sensitivity of DGPS reference receiver under noisy environment. This paper presents that the proposed GPS signal acquisition method suppresses the non-coherent integration loss through post-processing simulation. Furthermore, with regard to the mean acquisition time, it is shown that the number of search cells of the proposed GPS signal acquisition method is much fewer than that of the previous GPS signal acquisition method.

  • PDF

A Second-Order Particle Tracking Method

  • Lee, Seok;Lie, Heung-Jae;Song, Kyu-Min;Lim, Chong-Jeanne
    • Ocean Science Journal
    • /
    • v.40 no.4
    • /
    • pp.201-208
    • /
    • 2005
  • An accurate particle tracking method for a finite difference method model is developed using a constant acceleration method. Being assumed constant temporal and spatial gradients, the new method permits temporal-spatial variability of particle velocity. Test results in a solid rotating flow show that the new method has second-order accuracy. The performance of the new method is compared with that of other methods; the first-order Euler forward method, and the second-order Euler predictor-corrector method. The new method is the most efficient method among the three. It is more accurate and efficient than the other two.

Design of an Enhanced TDOA Method for Swept CW Interferences

  • Kang, Hee Won;Lim, Deok Won;Heo, Moon Beom
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.1 no.1
    • /
    • pp.23-27
    • /
    • 2012
  • Recently, devices like Personal Privacy Devices (PPD) are being employed to avoid the detection of one's location by GPS, and most PPD transmits swept CW signals. However, signals transmitted from PPD may interfere a precise location system based on GPS. Accordingly, in order to reduce interferences by PPD, a technique to locate an interferer is needed. In order to locate an interferer AOA method and TDOA method are generally used, TDOA method is known to be more accurate than AOA method. Unfortunately, TDOA method has a problem of ambiguity in obtaining measurements of swept CW interference. Thus, this paper design a localization algorithm based on TDOA method that can accurately locate an interferer transmitting swept CW signals by resolving problem of ambiguity. In addition, feasibility of the designed algorithm has been verified by simulation results.