• 제목/요약/키워드: Research field

검색결과 24,617건 처리시간 0.049초

Partial Solution for Concomitant Gradient Field in Ultra-low Magnetic Field: Correction of Distortion Artifact

  • Lee, Seong-Joo;Shim, Jeong Hyun
    • 한국자기공명학회논문지
    • /
    • 제24권3호
    • /
    • pp.66-69
    • /
    • 2020
  • In ultra-low field magnetic resonance imaging (ULF-MRI), the strength of a static magnetic field can be comparable to that of gradient field. On that occasion, the gradient field is accompanied by concomitant gradient field, which yields distortion and blurring artifacts on MR images. Here, we focused on the distortion artifact and derived the equations capable of correcting it. Its usefulness was confirmed through the corrections in both simulated and experimental images. This solution will be effective for acquiring more accurate images in low and/or ultra-low magnetic fields.

Azimuthal anchoring measurement of nematic liquid crystals using the strong magnetic field

  • Jang, Tae-Sug;Im, Ji-Young;Goh, Wan-Hee;Kim, Jong-Hyun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.664-667
    • /
    • 2009
  • We would like to show a measuring technique of azimuthal anchoring energy of the nematic liquid crystals. The electro-optical setup of liquid crystal cell, crossed polarizers and magnetic field was assumed. The planar or hybrid alignment cells were prepared. The director in the light entering substrate and the polarization of light was adjusted into parallel to the magnetic field. The director orientation of exit substrate and analyser maintained perpendicular to the magnetic field. As the magnetic field strength is increased, the director deviates from the easy axis and rotates to the field direction. We obtained an equation calculating the change of transmission with the field and measured experimentally the transmission. By comparing the calculating and experimental data, we obtained the azimuthal anchoring strength.

  • PDF

Magnetic levitation properties of single- and multi-grain YBCO bulk superconductors

  • Kim, C.J.;Yang, A.Y.;Lee, S.H.;Jun, B.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권3호
    • /
    • pp.52-56
    • /
    • 2022
  • Single-grain (c-normal or c-parallel) and multi-grain YBCO superconductors were prepared by a melt growth process with/without seeding. The magnetic levitation force and trapped magnetic field at liquid N2 temperature (77 K) of the YBCO superconductors were investigated. Samples for the levitation force measurement were zero-field cooled (ZFC) to 77 K, and samples for trapped field measurement were field-cooled (FC) using Nd magnets. As for the magnetic levitation force, the c-normal, single grain sample showed the largest value, whereas the multi-grain sample showed the lowest value. The trapped magnetic field of the c-normal and c-parallel single-grain samples was 4-5 times that of the multi-grain sample. In addition, as the external magnetic field (the number of magnets) increased, the both properties increased proportionally. These results were explained in terms of the orientation dependence of the levitation forces and the magnetic field trapping capability of the YBCO superconductor.

Studies on the suppression of transmission of anthracnose with covering method and environment friendly agricultural materials (EFAM) in pepper field

  • Kang, B.R.;Ko, S.J.;Kim, D.I.;Choi, D.S.;Kim, J.D.;Choi, K.J.
    • 한국유기농업학회지
    • /
    • 제19권spc호
    • /
    • pp.291-294
    • /
    • 2011
  • We studies a model for management of pepper anthracnose based covering method and spraying system in field. 1. Among 82 organic fungicides, 42 materials showed most effective inhibition against mycelia growth of the Colletotrichum acutatum in vitro. 23 formulated biocontrol agents were chosen to control the disease from 42 biocontrol agents in greenhouse. In the end, five kinds (2 plant extracts, 2 biopesiticides, 1 Bordeaux mixture) were selected from 23 materials in the field. 2. The mulching materials of bed covering in fruit season were thin non-woven fabric sheet and black plastic. The use of a fabric sheet was reduced the spread of anthracnose as compared to the plastic covering. 3. The application with the chosen materials was reduced 34% of anthracnose for 7 times sprays to planting 70 days as compared to the untreated control. In yield, nonwoven fabric sheet with formulated biopesticides was increased 17% than black plastic. 4. This result indicated that the developed biocontrol strategy could be an effective and economic crop protection system in organic pepper cultivation field.

동위원소를 이용한 연안역 현장실험 (A Field Tracer Experiment by Using a Radioisotope near the Offshore)

  • 김기철;박건형;이진용;정성희;민병일;서경석
    • 방사선산업학회지
    • /
    • 제6권1호
    • /
    • pp.41-47
    • /
    • 2012
  • A field tracer experiment using a radioisotope was conducted to analyze the transport and dispersion characteristics of pollutants in the coastal area near a Wolsung. A rod float including GPS was released to track the paths of radioisotope. NaI detector was installed to measure the released radioisotope from the boat, and measurements were performed with the real time. The measured tracer data by a field experiment can be used as the basic data for understanding the transport characteristics of pollutants and verifying numerical models near the offshore.

해석적 방법을 이용한 초전도 회전기의 3차원 자계 해석 (3D Magnetic Field Analysis of Superconducting Rotary Machine by Using Analytical Method)

  • 조영식;서무교;백승규;김석환;손명환;권영길;이정종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.616-618
    • /
    • 2002
  • A Superconducting Rotary Machine (SRM) is characterized by an air-cored machine with its rotor iron and stator iron teeth removed. For this reason, the SRM is featured by 3D magnetic flux distribution, which decreases in the direction of axis, Therefore, 3D magnetic field analysis method is required to know about characteristic of magnetic field distribution of SRM, In this paper, 3D flux distribution of SRM is calculation by using analytical method. The magnetic field distribution due to the field coils use of the Biot-Savart equation. The magnetic core is represented by magnetic surface polarities. The paper describes the combined use of above methods for the total computation, and compares analytical method and 3D FEM(Finite Element Method) results.

  • PDF

Optical Properties and Field Emission of ZnO Nanorods Grown on p-Type Porous Si

  • Park, Taehee;Park, Eunkyung;Ahn, Juwon;Lee, Jungwoo;Lee, Jongtaek;Lee, Sang-Hwa;Kim, Jae-Yong;Yi, Whikun
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권6호
    • /
    • pp.1779-1782
    • /
    • 2013
  • N-type ZnO nanorods were grown on p-type porous silicon using a chemical bath deposition (CBD) method (p-n diode). The structure and geometry of the device were examined by field-emission scanning electron microscopy (FE-SEM) and X-ray diffraction (XRD) while the optoelectronic properties were investigated by UV/Vis absorption spectrometry as well as photoluminescence and electroluminescence measurements. The field emission (FE) properties of the device were also measured and its turn-on field and current at 6 $V/{\mu}m$ were determined. In principle, the growth of ZnO nanorods on porous siicon for optoelectronic applications is possible.

Teleloperation of Field Mobile Manipulator with Wearable Haptic-based Multi-Modal User Interface and Its Application to Explosive Ordnance Disposal

  • Ryu Dongseok;Hwang Chang-Soon;Kang Sungchul;Kim Munsang;Song Jae-Bok
    • Journal of Mechanical Science and Technology
    • /
    • 제19권10호
    • /
    • pp.1864-1874
    • /
    • 2005
  • This paper describes a wearable multi-modal user interface design and its implementation for a teleoperated field robot system. Recently some teleoperated field robots are employed for hazard environment applications (e.g. rescue, explosive ordnance disposal, security). To complete these missions in outdoor environment, the robot system must have appropriate functions, accuracy and reliability. However, the more functions it has, the more difficulties occur in operation of the functions. To cope up with this problem, an effective user interface should be developed. Furthermore, the user interface is needed to be wearable for portability and prompt action. This research starts at the question: how to teleoperate the complicated slave robot easily. The main challenge is to make a simple and intuitive user interface with a wearable shape and size. This research provides multi-modalities such as visual, auditory and haptic sense. It enables an operator to control every functions of a field robot more intuitively. As a result, an EOD (explosive ordnance disposal) demonstration is conducted to verify the validity of the proposed wearable multi-modal user interface.