• Title/Summary/Keyword: Research cycle loop

Search Result 64, Processing Time 0.026 seconds

REVIEW OF SUPERCRITICAL CO2 POWER CYCLE TECHNOLOGY AND CURRENT STATUS OF RESEARCH AND DEVELOPMENT

  • AHN, YOONHAN;BAE, SEONG JUN;KIM, MINSEOK;CHO, SEONG KUK;BAIK, SEUNGJOON;LEE, JEONG IK;CHA, JAE EUN
    • Nuclear Engineering and Technology
    • /
    • v.47 no.6
    • /
    • pp.647-661
    • /
    • 2015
  • The supercritical $CO_2$ (S-$CO_2$) Brayton cycle has recently been gaining a lot of attention for application to next generation nuclear reactors. The advantages of the S-$CO_2$ cycle are high efficiency in the mild turbine inlet temperature region and a small physical footprint with a simple layout, compact turbomachinery, and heat exchangers. Several heat sources including nuclear, fossil fuel, waste heat, and renewable heat sources such as solar thermal or fuel cells are potential application areas of the S-$CO_2$ cycle. In this paper, the current development progress of the S-$CO_2$ cycle is introduced. Moreover, a quick comparison of various S-$CO_2$ layouts is presented in terms of cycle performance.

Conceptual Design of Korea Aerospace Research Institute Lunar Explorer Dynamic Simulator

  • Rew, Dong-Young;Ju, Gwang-Hyeok;Kang, Sang-Wook;Lee, Sang-Ryool
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.4
    • /
    • pp.377-382
    • /
    • 2010
  • In lunar explorer development program, computer simulator is necessary to provide virtual environments that vehicle confronts in lunar transfer, orbit, and landing missions, and to analyze dynamic behavior of the spacecraft under these environments. Objective of simulation differs depending on its application in spacecraft development cycle. Scope of use cases considered in this paper includes simulation of software based, processor and/or hardware in the loop, and support of ground-based flight test of developed vehicle. These use cases represent early phase in development cycle but reusability of modeling results in the next design phase is considered in defining requirements. A simulator architecture in which simulator platform is located in the middle and modules for modeling, analyzing, and three dimensional visualizing are connected to that platform is suggested. Baseline concepts and requirements for simulator development are described. Result of trade study for selecting simulation platform and approaches of defining other simulator components are summarized. Finally, characters of lunar elevation map data which is necessary for lunar terrain generation is described.

Thermal and telemetry module design for satellite camera

  • Kong, Jong-Pil;Yong, Sang-Soon;Heo, Haeng-Pal;Kim, Young-Sun;Youn, Heong-Sik
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.229-234
    • /
    • 2002
  • Under the hostile influence of the extreme space environmental conditions due to the deep space and direct solar flux, the thermal control in space applications is especially of major importance. There are tight temperature range restrictions for electro-optical elements while on the other hand there are low power consumption requirements due to the limited energy sources on the spacecraft. So, we usually have strong requirement of thermal and power control module in space applications. In this paper, the design concept of a thermal and power control module in the MSC(Multi-Spectral Camera) system which will be a payload on KOMPSATII is described in terms of H/W & S/W. This thermal and power control module, called THTM(Thermal and Telemetry Module) in MSC, resides inside the PMU(Payload Management Unit) which is responsible for the proper management of the MSC payload for controlling and monitoring the temperature insides the EOS(Electro-Optic System) and gathering all the analog telemetry from all the MSC sub-units, etc. Particularly, the designed heater controller has the special mode of "duty cycle" in addition to normal closed loop control mode as usual. THTM controls heaters in open loop according to on/off set time designed through analysis in duty cycle mode in case of all thermistor failure whereas it controls heaters by comparing the thermistor value to temperature based on closed loop in normal mode. And a designed THTM provides a checking and protection method against the failure in thermal control command using the test pulse in command itself.

  • PDF

Research on the Development of the Supercritical CO2 Dual Brayton Cycle (초임계 이산화탄소 이중 브레이튼 사이클 개발 연구)

  • Baik, Young-Jin;Na, Sun Ik;Cho, Junhyun;Shin, Hyung-Ki;Lee, Gilbong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.10
    • /
    • pp.673-679
    • /
    • 2016
  • Because of the growing interest in supercritical carbon dioxide power cycle technology owing to its potential enhancement in compactness and efficiency, supercritical carbon dioxide cycles have been studied in the fields of nuclear power, concentrated solar power (CSP), and fossil fuel power generation. This study introduces the current status of the research project on the supercritical carbon dioxide power cycle by Korea Institute of Energy Research (KIER). During the first phase of the project, the un-recuperated supercritical Brayton cycle test loop was built and tested. In phase two, researchers are designing and building a supercritical carbon dioxide dual Brayton cycle, which utilizes two turbines and two recuperators. Under the simulation condition considered in this study, it was confirmed that the design parameter has an optimal value for maximizing the net power in the supercritical carbon dioxide dual cycle.

A Novel Compensator for Eliminating DC Magnetizing Current Bias in Hybrid Modulated Dual Active Bridge Converters

  • Yao, Yunpeng;Xu, Shen;Sun, Weifeng;Lu, Shengli
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1650-1660
    • /
    • 2016
  • This paper proposes a compensator to eliminate the DC bias of inductor current. This method utilizes an average-current sensing technique to detect the DC bias of inductor current. A small signal model of the DC bias compensation loop is derived. It is shown that the DC bias has a one-pole relationship with the duty cycle of the left side leading lag. By considering the pole produced by the dual active bridge (DAB) converter and the pole produced by the average-current sensing module, a one-pole-one-zero digital compensation method is given. By using this method, the DC bias is eliminated, and the stability of the compensation loop is ensured. The performance of the proposed compensator is verified with a 1.2-kW DAB converter prototype.

Related Conception s to Earth System and Applying of Systems Thinking about Carbon Cycle of the Preservice Teachers (예비교사들의 탄소 순환에 대한 지구시스템의 관련개념과 시스템 사고의 적용)

  • Jeong, Jin-Woo;kyung, Jai-Bok;Koh, Yeong-Koo;Youn, Seok-Tae;Kim, Hai-Gyoung;Oh, Kang-Ho;Moon, Byoung-Chan
    • Journal of the Korean earth science society
    • /
    • v.25 no.8
    • /
    • pp.684-696
    • /
    • 2004
  • Using six preservice teachers as subjects, this was purpose to research about concepts in understanding carbon cycle, which of concepts were related to the conception of the system, and finally whether or not the systems thinking was sufficiently around carbon cycle. To achieve this study purpose , an instrument related to carbon cycle was developed and administered to the six teachers. The study found that a total of 42 conceptions within the system were concepts related to carbon cycle. The consisted of 15 conceptions in atmosphere, 11 in atmosphere 9 in hydrosphere, and 7 in lithosphere. In aspect of applying the system thinking, 4 subjects who couldn't compose the feedback loop in their causal map failed to apply this type of thinking. The other two who applied systems thinking had 2 and 1 feedback loop each, in their causal maps. But, one of the feedback loop from the subject who made two was based on unscientific reasoning. As a result, the subjects had lower understanding of concepts related to carbon cycle in lithosphere than in atmosphere, atmosphere, and hydrosphere. Futhermore, the subjects' application of the earth systems thinking on carbon was at a low standard.

Population Ageing Crisis and Causal loop Analysis on the It's Dynamics in Rural County Regions (우리나라 군지역의 고령화 위기와 동태성의 인과순환적 구조분석)

  • Choi, Nam Hee;Lee, Jong Kun;Kim, Keun Sei;Lee, Myung Suk
    • Korean System Dynamics Review
    • /
    • v.15 no.1
    • /
    • pp.75-96
    • /
    • 2014
  • This research primarily aims at analyzing major crises originating from marginalizing population, especially in counties. In addition, based on the system dynamics approaches, it pays attention to divulging causal loop structure which has been rather strengthened by diverse interactions among key variables. Judging from simulation works, even though Korea is exposed to unprecedented aging trends over decades, its counter response seems inadequate and insufficient, mostly dismissing a series of impact embedded in the aging dynamics. This research statistically confirms that demographic marginalization trends have already begun in the villages within Eup and Myon counties. Furthermore, this research pinpoints out the fact that it would be almost impossible for majority of villages within Eup and Myon counties to escape from going out of existence in the course of time, as they tend to be entrapped vicious cycle of marginalization or extinction.

  • PDF

A Study on Entering Water Temperature in Vertical Closed Ground Loop System Considering the Economical Feasibility in Load of the Office Building (사무시설에 수직형 지열원 냉 난방시스템의 경제성을 고려한 인입온도(EWT)에 관한 연구)

  • Lee, Byung-Doo;Lee, Dae-Woo;Lee, Se-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.579-585
    • /
    • 2009
  • Recently, Vertical-Closed Loop system using geothermal which is the most efficient among the building cooling and heating systems is coming into wide spread due to assistance of domestic policies. However, there is a limitation that a design of ground heat exchanger taking 60% of construction cost is done by GLD and GLHEPRO programs without specific guidelines and consideration on Entering Water Temperature(EWT). For getting an optimal EWT, we analyzed the costs for construction of ground heat exchanger and cooling and heating for 15 years. In the results, reduction of construction costs as the length of ground heat exchanger shortens was much greater than increase of the electrical power consumption as COP gets low. EWT that COP of heat pump can be 3.76 or above was below $31^{\circ}C$ in cooling and was over $5^{\circ}C$ in heating.

  • PDF

The Rock Cycle Composition Elements and Process of the Pre-service Earth Science Teachers' Understanding (암석 순환의 구성요소와 과정에 대한 예비 지구과학 교사들의 이해)

  • Kim, Yun-Ji
    • Journal of the Korean Society of Earth Science Education
    • /
    • v.9 no.2
    • /
    • pp.186-198
    • /
    • 2016
  • The purpose of this study is to identify the composition elements and processes of the rock cycle that pre-service teachers in earth science field understand. Second-year students majoring in earth science were selected as research objects, all of whom attended teacher's university located in the southern region. The methods of arranging the composition elements of the rock cycle in a structured way and displaying the cycle direction through the arrow and describing the cycle processes in detail were applied. Pre-service teachers recognized 5 composition elements: magma, igneous rocks, sediments, sedimentary rocks, metamorphic rocks of the rock cycle and cycle processes was represented into 20 branches. The cycle type was analyzed by four criteria: linear, triangular, circular, complex, some pre-teachers did not complete the loop of the cycle or some showed incomplete understanding of the cycle structure simply displayed in one direction. The rock cycle is an important theme of the earth system education characterized by dynamism and complexity.

Development of Map based Open Loop Control Algorithm for Urea - SCR System (Urea-SCR 시스템의 Map 기반 Open Loop 제어알고리즘 개발)

  • Ham, Yun-Young;Park, Yong-Sung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.2
    • /
    • pp.50-56
    • /
    • 2011
  • To meet the NOx limit without a penalty of fuel consumption, Urea-SCR system is currently regarded as promising NOx reduction technology for diesel engines. SCR system has to achieve maximal NOx conversion in combination with minimal $NH_3$ slip. In this study, map based open loop control for urea injection was developed and assessed in the European Transient Cycle (ETC) for heavy duty diesel engine. The basic urea quantity set-value which was calculated using the look up tables of engine out NOx, exhaust flow rate and optimum NSR resulted in NOx reduction of 80% and the average $NH_3$ slip of 24 ppm and maximum of 79 ppm. In order to reduce $NH_3$ slip, $NH_3$ storage control algorithm was applied to correct the basic urea quantity and reduced $NH_3$ slip levels to the average 15 ppm and maximum 49 ppm while keeping NOx reduction of 76%. With high and increasing SCR temperature, the $NH_3$ storage capacity decreases, which leads to $NH_3$ slip. The resulting $NH_3$ slip peak can be avoided by stopping or significantly reducing the urea injection during the SCR temperature gradient is over $30^{\circ}C/min$.