• 제목/요약/키워드: Research System Procedure

검색결과 1,712건 처리시간 0.027초

내부점 선형계획법에서의 사후처리 (Postsolving in interior-point methods)

  • 이상욱;임성묵;성명기;박순달
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회 2003년도 추계학술대회 및 정기총회
    • /
    • pp.89-92
    • /
    • 2003
  • It is often that a large-scale linear programming(LP) problem may contain many constraints which are redundant or cause infeasibility on account of inefficient formulation or some errors in data input. Presolving or preprocessing is a series of operations which removes the underlying redundancy or detects infeasibility in the given LP problem. It is essential for the speedup of an LP system solving large-scale problems to implement presolving techniques. For the recovery of an optimal solution for the original problem from an optimal solution for the presolved problem, a special procedure, so called postsolving, must be applied. In this paper, we present how a postsolving procedure is constructed and implemented in LPABO, a interior-point based LP system. Briefly, all presolving processes are logged in a data structure in LPABO, and after the end of the solution method an optimal solution for the original problem is obtained by tracing the logs. In each stage of the postsolving procedure, the optimality of intermediate solutions is maintained. We tested our postsolving procedure on Netlib, Gondzio and Kennington LP data sets, and concluded that the computational burden of the procedure is relatively negligible compared with the total solving time.

  • PDF

매트릭스 해법을 이용한 포장체 각 층의 탄성계수 추정 역산알고리즘의 개발 (Development of Backcalculation Algorithm of Pavement System Using Matrix Solution Technique)

  • 김수일;이광호;박병현
    • 대한토목학회논문집
    • /
    • 제14권3호
    • /
    • pp.495-508
    • /
    • 1994
  • 본 연구에서는 FWD 등의 비파괴 시험장비를 사용하여 포장체 각 층의 탄성계수를 추정할 때 필요로 하는 역산알고리즘을 매트릭스 해법을 이용하여 개발하고 수치모델을 통하여 알고리즘의 신뢰성을 검정하였다. 역산알고리즘에 적용한 포장구조해석 전산 프로그램으로는 다층탄성해석 전산 프로그램인 SINELA를 사용하였다. 역산 초기의 가정 탄성계수 및 가상암반층의 깊이 설정에는 포장 단면에 따른 data base를 구성한 후 이를 이용하는 방법을 택하였다. 본 연구개발의 역산 프로그램은 수치모델을 통한 분석에서 매우 정확한 역산결과를 주고 있음을 알 수 있었다. 또한, 기존의 역산 프로그램인 FPEDD1과 결과비교를 통해 본 프로그램이 역산 소요시간 및 정도 면에서 우수함을 알 수 있었다.

  • PDF

헬리콥터 관절형 로터 시스템용 마하 축소 복합재료 블레이드 개발 (Development of Mach Small-scaled Composite Blade for Helicopter Articulated Rotor System)

  • 김덕관;송근웅;김준호;주진
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 춘계학술발표대회 논문집
    • /
    • pp.57-60
    • /
    • 2003
  • This Paper contains the development procedure of Mach small-scaled composite rotor blade for helicopter articulated rotor system. This mach small-scaled composite blade design is conducted by using CORDAS program developed by KARI. The Dynamic analysis for an articulated rotor system with this blade is conducted by using FLIGHTLAB which is commercial software for helicopter analysis. Also the optimizing procedure of iterative design was described. The designed composite blades were manufactured after establishing the effective curing method. For small-scaled rotor test, strain gauges were embedded in composite blade spar to obtain bending & torsion strain value. To verify sectional properties of a blade, the bench test is accomplished. After comparing a designed data and tested data, Dynamic Calculation was repeated using tested data. Through this research, experiences of mach small-scaled composite blade development were accumulated and will be applied to the related research field.

  • PDF

Structural integrity assessment procedure of PCSG unit block using homogenization method

  • Gyogeun Youn;Wanjae Jang;Youngjae Jeon;Kang-Heon Lee;Gyu Mahn Lee;Jae-Seon Lee;Seongmin Chang
    • Nuclear Engineering and Technology
    • /
    • 제55권4호
    • /
    • pp.1365-1381
    • /
    • 2023
  • In this paper, a procedure for evaluating the structural integrity of the PCSG (Printed Circuit Steam Generator) unit block is presented with a simplified FE (finite element) analysis technique by applying the homogenization method. The homogenization method converts an inhomogeneous elastic body into a homogeneous elastic body with same mechanical behaviour. This method is effective when the inhomogeneous elastic body has repetitive microstructures, and thus the method was applied to the sheet assembly among the PCSG unit block components. From the method, the homogenized equivalent elastic constants of the sheet assembly were derived. The validity of the determined material properties was verified by comparing the mechanical behaviour with the reference model. Thermo-mechanical analysis was then performed to evaluate the structural integrity of the PCSG unit block, and it was found that the contact region between the steam header and the sheet assembly is a critical point where large bending stress occurs due to the temperature difference.

사례기반 추론방법을 이용한 치공구의 선정 (Fixture Planning Using Case-Based Reasoning)

  • 현상필;이홍희
    • 산업경영시스템학회지
    • /
    • 제22권51호
    • /
    • pp.129-138
    • /
    • 1999
  • The aim of this research is the development of an automated fixture planning system for prismatic parts using the case-based reasoning (CBR). CBR is the problem solving paradigm that uses the similarity between a new problem and old cases to solve the new problem. This research uses CBR for the fixture planning. A case is composed with the information of the part, the components of fixture and the method of fixing for the part. The basic procedure is the retrieval and adaptation for the case, and this research presents the method of retrieval that selects most similar case to the new situation. The retrieval-step is divided into an index matching and an aggregated matching. The adaptation is accomplished by the modification, which transforms the selected case to the solution of the situation of the input part by the specified CBR algorithm. The components of fixture and the method of fixing are determined for a new part by the procedure.

  • PDF

스프링 격발형 생검총 구조를 가진 생검 시술 자동화 로봇 말단장치 (A Robot End-effector for Biopsy Procedure Automation with Spring-Triggered Biopsy Gun Mechanism)

  • 원종석;문영진;박상훈;최재순
    • 제어로봇시스템학회논문지
    • /
    • 제22권8호
    • /
    • pp.590-596
    • /
    • 2016
  • Biopsy is a typical needle type intervention procedure performed under radiographic image equipment such as computed tomography (CT) and cone-beam CT. This minimal invasive procedure is a simple and effective way for identifying cancerous condition of a suspicious tissue but radiation exposure for the patients and interventional radiologists is a critical problem. In order to overcome such trouble and improve accuracy in targeting of the needle, there have been various attempts using robot technology. Those devices and systems, however, are not for full procedure automation in biopsy without consideration for tissue sampling task. A robotic end-effector of a master-slave tele-operated needle type intervention robot system has been proposed to perform entire biopsy procedure by the authors. However, motorized sampling adopted in the device has different cutting speed from that of biopsy guns used in the conventional way. This paper presents the design of a novel robotic mechanism and protocol for the automation of biopsy procedure using spring-triggered biopsy gun mechanism. An experimental prototype has been successfully fabricated and shown its feasibility of the automated biopsy sequence.

부유식 파력발전장치용 계류선의 설계 및 안전성 검토에 관한 연구 (Investigation of Safety and Design of Mooring Lines for Floating Wave Energy Conversion)

  • 정동호;남보우;신승호;김현주;이호생;문덕수;송제하
    • 한국해양공학회지
    • /
    • 제26권4호
    • /
    • pp.77-85
    • /
    • 2012
  • A study was performed on the design of a mooring line to maintain the position of a floating WEC (wave energy conversion) system. The procedure to design a mooring line is set up and the safety of the designed mooring system is evaluated using commercial software, Orcaflex. The characteristics curve for one line is analyzed to determine the properties and pretension of a mooring line. While considering the ocean environmental condition and importance of a floating WEC system, a multi-line layout is determined. A 4-point mooring system with 4 lines shows the instability in the yaw motion of the floating WEC system under a designed ocean environmental condition. The redesigned 4-point mooring system with 8 lines is found to be safe on the condition of a harsh ocean environment. The floating WEC system with the redesigned mooring system also shows stable motion in surge and pitch under operating conditions. From a parametric study on the mooring line length, the extreme value of the mooring line tension is found to be very sensitive to the pretension and length of mooring line. The results of this study can contribute to the establishment of a design procedure for mooring lines.

전문의 대상 설문조사를 이용한 보건의료 기술평가 대상 시술의 우선 순위 선정 - 이비인후과와 흉부외과를 중심으로 - (Prioritisation of Medical Procedure for Health Technology Assessment)

  • 안형식;김선민;신영수;김차엽;김선미;이순형
    • 보건행정학회지
    • /
    • 제7권2호
    • /
    • pp.46-64
    • /
    • 1997
  • Background & Objectives : Korea is face with the social need for health care technology assessment so that it is urgently needed to found principles and methodology in technology assessment in health care. As a groundwork for health care technology assessment, we tried to prioritize medical technology for assessment. Among medical technologies, procedure is somewhat difficult to assess, compared to drug or equipment. In this study, we aimed at the prioritisation of medical procedure to be assessed, in terms of efficay, safety, and adequacy. Method : For the standardized classification of medical procedure, ICD-9-CM(International Classification of Diseases 9th edition - Clinical Modification) was used. Among the list the procedures coming under otorhinolaringjology and thoracic surgery were selected by three family physicians. The list of procedure was mailed to the board certified surgeons of both disciplines, with the question asking about the necessity for assessment in terms of efficay, safety, and adequacy. Replied questionnaires were analyzed in each procedure. Results : Of 560 otorhinolaryngologist and 480 thoracic surgeon, 114 surgeons replied. Of otorhinolaryngological procedure, incision, excision, and destruction of inner ear : fenestration of inner ear : stapedectomy and its revision were the most urgent technology to assess in the aspect of safety. For adequacy, operations on Eustachian tube: fenestration of inner ear: incision, excision, and destruction of inner ear were highly ranked in necessity, and for efficary, operations on Eustachian tube; external maxillary antrotomy; fenestration of inner ear. Thoracic surgeons replied thoracic procedures, lung transplantation; heart transplantation; implantation of heart assist system [pump] are most important for evaluation in terms of safety; and heart transplantation; Lung transplantation; Implantation of heart assist system [pump] in terms of adequacy, and surgical collapse of lung [Artificia니 pnemothorax or pnuexoperitoeum]; lung transplantation; periarterial sympathectomy in terms of efficacy. As a whole, surgeons regard safety evaluation is more urgent than adequacy or efficary. In addition, otorhinolaryngological surgeons regard evaluation of their procedures more urgent than thoracic surgeons regard theirs. Conclusion : By the questionnaire to board certified physicians, we get some preliminary data for prioritisation of technologies to assess. Through the questionnaire like this, much information would be gathered for technology assessment, especially for medical procedure, if not enough. In the near future, well structured expert opinion gathering research, such as modified Delphi or nominal group technique, should be done succeedingly.

  • PDF

진부화 제품의 단일 생산 재고 모델에 관한 연구 (A study on a single production inventory model with decaying items)

  • 소재영;윤덕균
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 1995년도 춘계공동학술대회논문집; 전남대학교; 28-29 Apr. 1995
    • /
    • pp.476-486
    • /
    • 1995
  • In this paper, an attempt has been made to revise Raafat' s(1985) results on an inventory model for decaying raw materials and the finished product at a constant rate which was based on Goyal's integrated inventory model for a single product system. This paper is concerned with scheduling the frequencies of order quantity of several different raw materials on a production inventory model. The purpose of this paper is to present a simple method of deciding the frequencies of order quantity of raw materials, in the sense of minimizing the average total cost of the system. We describe on iterative procedure for directly determining near optimal frequencies of order quantity for the raw materials and the associated fundamental cycle time which can be used for constructing the production duration of the finished product. In cases where feasible schedules cannot be constructed using the values from the iterative procedure, the procedure provides a basis for changing the order quantity frequencies and the fundamental cycle time to obtain feasible schedules. An example is given to illustrate the derived results.

  • PDF