• Title/Summary/Keyword: Research Facility

Search Result 4,438, Processing Time 0.033 seconds

The Impact of Cultural Similarity on the International Distribution Management

  • Zhang, Jun;Lee, Hoonyoung
    • Journal of Distribution Science
    • /
    • v.15 no.12
    • /
    • pp.21-30
    • /
    • 2017
  • Purpose - This research approaches to the new niche market of medical tourism to investigate how factors of cultural similarity influence the international distribution management. This study also estimates the interaction effects of distribution channel on the relationships of facility attributes and customers' destination choice behavior. Research design, data, and methodology - We collected the sample of 881 potential customers from the more economically developed regions in China. Regression analysis is used to confirm the relationships in the research model. Results - The result shows that cultural similarity plays an important moderating role in the relationships of facility attributes and destination choice intention. For instance, power distance and masculinity interact with the distribution facility characteristics of medical quality and reputation to influence customers' selection of the destination country. Individualism, powder distance, and masculinity play moderating roles when social environment affects destination choice intention. Especially, all the elements of cultural similarity moderate the relationships between travel cost and destination choice intention. This research also proves that depending on distribution channel, determinants of distribution facility are the critical predictors of intention to select the medical service outside of China. Conclusions - The study enables managers to develop the more effective strategies reflecting the interaction effects of cultural similarity and distribution channel on customers' decision-making process.

PREDICTION OF THE TRITIUM CONCENTRATION IN THE SOIL WATER AFTER THE OPERATION OF WOLSONG TRITIUM REMOVAL FACILITY

  • CHOI HEUI-JOO;LEE HANSOO;SUH KYUNG SUK;KANG HEE SUK
    • Nuclear Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.385-390
    • /
    • 2005
  • The effect of the Wolsong Tritium Removal Facility on the change of tritium concentration in the soil water was assessed by introducing a dynamic compartment model. For the mathematical modeling, the tritium in the environment was thought to come from two different sources. Three global tritium cycling models were compared with the natural background concentration. The dynamic compartment model was used to model the behavior of the tritium from the nuclear power plants at the Wolsong site. The source term for the dynamic compartment model was calculated with the dry and wet deposition rates. The area around the Wolsong nuclear power plants was represented by the compartments. The mechanisms considered in deriving the transfer coefficients between the compartments were evaporation, runoff, infiltration, hydrodynamic dispersion, and groundwater flow. We predicted what the change of the tritium concentration around the Wolsong nuclear power plants would be after future operation of the tritium removal facility to show the applicability of the model. The results showed that the operation of the tritium removal facility would reduce the tritium concentration in topsoil water quickly.

A Study on the Planning Criteria for Thalassotherapy Facility (해양치유시설 계획기준에 관한 연구)

  • Lee, Han-Seok;Kang, Young-Hun;Seong, Hai-Min
    • Journal of Navigation and Port Research
    • /
    • v.44 no.1
    • /
    • pp.20-31
    • /
    • 2020
  • The purpose of this study was to provide planning criteria for the thalassotherapy facility. Among the various contents of the planning criteria, the crucial parts of the thalassotherapy facility planning are the location, facility environment, and room space. To do this, we first examined the characteristics of the thalassotherapy facility and inquired about the thalassotherapy resources and treatments that are the basis of the thalassotherapy facility planning. And then, the overseas qualification criteria related to thalassotherapy facility were analyzed. Based on the above research results, the criteria for the thalassotherapy facility planning on location, facility environment, and spaces of rooms are presented. The location is within 1km of the coastline, where there is no pollutant emission facility, and the climate conditions are maintained more than 80% throughout the year below 'caution' level of the thermal sensation index and sensory temperature. The water quality of the facility environment meets the stricter criteria among the domestic standards or ISO 17680 standards, and the air quality is 60% of the atmospheric environment standard of the 「Framework Act on Environmental Policy」 and SO2, NO2, O3 and PM10 concentration shall ensure that the annual number of exceeding standards meets the EU standard, and noise is less than 50dB per daytime, 40dB per night. Therapy spaces have to meet the standards of the 「Building Act」, the working standards of architectural planning and international standards according to their function and use.

The Development of N2O Emission Factor at Killn Type Pyrolysis Melting Facility (외열킬른형 열분해용융시설의 N2O 배출계수 개발)

  • Yun, Hyun-Ki;Lee, Dae Kyeom;Cho, Changsang;Kang, Seongmin;Yoon, Young joong;Jeon, Youngjae;Jeon, Eui Chan
    • Journal of Climate Change Research
    • /
    • v.8 no.3
    • /
    • pp.231-237
    • /
    • 2017
  • In this study, the $N_2O$ emission factor of the facility was developed by measuring the kiln type pyrolysis melting facility. This used PAS (Photoacoustic Spectroscopy) method and measured the $N_2O$ emission concentration. From March 2016 to April 2016, it was measured over a total of two times and $N_2O$ concentrations were measured continuously for 24 hours using a 24 hour continuous measuring instrument (LSE-4405). The measured $N_2O$ emission concentration of the pyrolysis melting facility was 0.263 ppm on average and the emission concentration distribution in the range of 0.013~0.733 ppm was obtained. Therefore, the $N_2O$ emission factor of the kiln-type pyrolysis melting facility was estimated to be $0.829gN_2O/ton$-Waste. As a result of comparing the $N_2O$ emission factor of the thermal kiln type pyrolysis melting facility and the previous study, previous studies were about 18 times higher. It is estimated that this is due to the difference of furnace temperature, oxygen concentration and denitrification facilities. It is considered that the study of the emission factor of pyrolysis melting facility is an important factor in improving the credibility of greenhouse gas inventory in waste incineration sector.

Facility Location Planning with Realistic Operation Times in Supply Chain (공급사슬에서 실제 시설물 운영시간을 고려한 시설배치계획에 관한 연구)

  • Lee Sang Heon;Kim Sook Han
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.30 no.2
    • /
    • pp.143-156
    • /
    • 2005
  • Facility location planning (FLP) problem is the strategic level planning in supply chain. The FLP is significantly affected by the operation time of each facility. In most of the FLP researches, operation time of facility has been treated as a fixed value. However, the operation time is not a static factor in real situations and the fixed operation time may lead unrealistic FLP. In this paper, a mixed integer programming (MIP) model is proposed for solving the 3-stage FLP problem and operation times are adjusted by the results from the simulation model and an iterative approach combining the analytic model and simulation model is proposed to obtain more realistic operation plans for FLP problems.

Modification of Dia. 2m-Small-scaled Rotor Test Facility (직경 2m급 축소로터 시험장치 개조 및 보완)

  • Song, Keun Woong;Lee, Jae Ha;Kim, Seoung Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.190-195
    • /
    • 2012
  • Small-scaled Rotor Test facility(GSRTS, General Small-scaled Rotor Test Facility) in KARI could not use the test because facility aging and parts discontinued. Also in order to perform a joint international research, GSRTS modifications should be needed. So requirements of GSRTS modifications were established and according to the requirements, GSRTS modifications were conducted. Facility operation test, 6-component fixed balance calibration, Small-scaled OLS rotor performance test were performed to verify the results of GSRTS modifications. Reasonable results were obtained in comparison to calculation results. Then GSRTS ready was completed to conduct international collaborative research and wind tunnel test.

  • PDF

An Analysis of Educational Facility Planning Focused on Various Career Pursuit & its Possibilities of Application - Based on the Research & Development of CEFPI - (다양한 교육시설계획(敎育施設計劃)과 그 응용(應用) 가능성(可能性)에 관한 분석연구(分析硏究)(II) - 국제교육시설기구(CEFPI)의 연구활동을 통하여 -)

  • Ryu, Hyang-San
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.1 no.2
    • /
    • pp.7-20
    • /
    • 1994
  • The Council of Educational Facility Planners, International: CEFPI included about 20 countries (now another members are continuously registering) have some decision making of the master plan for the educational facilities and buildings in constructing/consulting for the world education. Through the research & development of the educational facility & building designing by the Council members who are the professional, of the nursery to higher education. At the same time they will have some master plan for the connected school & university facility's & building's designing/constructing system, having for the White-, blue-, steel-, and idea color job's educational facilities. The Council will be Given a desirable 72nd Birthday 1995 with the 21st Century's Educational Facility Master plan.

  • PDF

A Comparative Analysis on the Merits and Demerits in Domestic and Overseas Public Facilities Management (P-FM)

  • Yoon, Seung-Wook;Lee, Chun-Kyong
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.357-360
    • /
    • 2015
  • For the last 40 years, the Korean government has built and supplied diverse public facilities. The Korean government, which has supplied diverse public facilities for the last 40 years, has maintained these public facilities as breakdown maintenance under limited budget. Because of increase of aging of public facilities and insufficient budget, it needs the total public facility maintenance. Especially, as Japan has also experienced similar issues and solved these, they are the introduction of P-FM theory and see successful examples. In this study, by comparison Analysis on the Merits and Demerits for Public Facility management (P-FM) between domestic and abroad, it would find a future direction to public facility management P-FM is to go.

  • PDF

Radiological Assessment of Environmental Impact of the IF-System Facility of the RAON

  • Lee, Cheol-Woo;Whang, Won Tae;Kim, Eun Han;Han, Moon Hee;Jeong, Hae Sun;Jeong, Sol;Lee, Sang-jin
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.2
    • /
    • pp.58-65
    • /
    • 2021
  • Background: The evaluation of skyshine distribution, release of airborne radioactive nuclides, and soil activation and groundwater migration were required for radiological assessment of the impact on the environment surrounding In-Flight (IF)-system facility of the RAON (Rare isotope Accelerator complex for ON-line experiment) accelerator complex. Materials and Methods: Monte Carlo simulation by MCNPX code was used for evaluation of skyshine and activation analysis for air and soil. The concentration model was applied in the estimation of the groundwater migration of radionuclides in soil. Results and Discussion: The skyshine dose rates at 1 km from the facility were evaluated as 1.62 × 10-3 μSv·hr-1. The annual releases of 3H and 14C were calculated as 9.62 × 10-5 mg and 1.19 × 10-1 mg, respectively. The concentrations of 3H and 22Na in drinking water were estimated as 1.22 × 10-1 Bq·cm-3 and 8.25 × 10-3 Bq·cm-3, respectively. Conclusion: Radiological assessment of environmental impact on the IF-facility of RAON was performed through evaluation of skyshine dose distribution, evaluation of annual emission of long-lived radionuclides in the air and estimation of soil activation and groundwater migration of radionuclides. As a result, much lower exposure than the limit value for the public, 1 mSv·yr-1, is expected during operation of the IF-facility.

Setup of standard PD calibrator and its uncertainties

  • Kim, Kwang-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.677-683
    • /
    • 2011
  • The present paper describes the setup of standard partial discharge calibrator for measuring partial discharge and estimating uncertainties. The standard PD calibrator was designed and set up, consisting of a digital pulse generator, capacitor modules, and a digital oscilloscope controlled by software developed in the laboratory. Using this software, averages of charges and rising times and their standard deviations in the measured pulses can also be calculated. The standard PD calibrator generates five types of pulses: single, double, random, oscillating, and long-rising. The coefficient sensitivities to estimate the uncertainties of pulses were extracted in the model circuit of the standard PD calibrator. The uncertainties of charges and rising times in pulses of the standard PD calibrator were estimated with single pulses. These values were 0.3%-1.4% in charges and 1.9%-7.0% in rising time; however, these values are lower than the limit values in IEC 60270.