• Title/Summary/Keyword: Research Facility

Search Result 4,470, Processing Time 0.034 seconds

Study of the Space Propriety of the Modernized Elementary School's facilities (현대화 초등학교 공간의 유형에 따른 시설의 적정성에 대한 연구)

  • 이은창;이상호
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2001.05a
    • /
    • pp.149-152
    • /
    • 2001
  • Goals of this study are to analyze various types of facility disposition which is brought out in the facility space plan of the modernized elementary school which has been founded and conducted by Seoul city, and most of all, to grasp the space propriety through understanding the peculiarity of the plan by the space analysis form. To proceed this study, I will divide it to three steps; 1. First step : Research into the space alternation of an (Korean) elementary school which has been gotten changed by the alternation of an elementary school. 2. Second step : Research into the efficient studying-space of a modernized elementary school by contemplating analysis of cases which comes from the literature research, collecting related data, and making an on-the-spot survey

  • PDF

Research on the Status Inquiry and Complex Characters of Public Facilities for the Community Life Style in Seoul (서울시 주민생활지원을 위한 공공시설의 현황 및 복합화 특성에 관한 조사연구)

  • Suh, Kuee-Sook
    • Journal of the Korean housing association
    • /
    • v.21 no.2
    • /
    • pp.19-30
    • /
    • 2010
  • The aim of this research is to understand the characteristics and status of existing public facilities, in order to propose the necessary basic materials for the planning and development of improved public facilities to assist communities. Objects of this research are the public facilities provided by the Government throughout the 25gu in Seoul. The methods of this research were carried out through the home page of each facility, telephone inquiries and gujung backseo. Investigations were carried out 3 times between the periods of January-June and September in 2009. Results of the research are as follows - 1) Through the investigations of classifications and distribution status of 5 public facilities over 25gu, quantity supply problems were analyzed. 2) Building distributions of 5 public facilities were classified by types and analyzed. 3) A number of compound facilities were classified and analyzed to determine the complexities of the 5 public facilities. 4) Complex types and characteristics of public facilities in 25gu in Seoul were analyzed. Based on the results of the research, the following conclusions are drawn: 1) Public facilities throughout the 25gu in Seoul have common characteristics and functions and they are spread out evenly in each gu. This means that public facilities are standardized in Seoul. Characteristic public facilities suitable to each gu should be planned accordingly. 2) Public facilities in Seoul show a single form of one facility. Therefore, initiative plans for the complexity of facilities are required. 3) Complex public facilities in Seoul need to be the center of community life in each gu. It is necessary to take into account the diverse life styles and classified needs of residents for complex facilities. Based on the research, complex types such as public administrative+cultural facilities, culture+welfare facilities, medical+welfare facilities can be presented. These complex types should not be classified according to any particular use, but they should be commonly used by diverse generations and every social class. The inquiries of users of public facilities and the programs of each public facility are not included in this research. Thus, the reseaarch limits the proposals for complex public facilities. In the future, the characteristics of each gu in Seoul should be studied and understood, so that appropriate public facilities and their complex plans can be researched continuously and necessarily.

Structural Safety Analysis Of Rear Door in ACP Hotcell Facility for Spent Fuel Treatment (사용후핵연료 차세대관리 종합공정 실증시설내 후면 차폐문의 구조적 안전성 평가)

  • Kwon, Kie-Chan;Ku, Jeong-Hoe;Lee, Eun-Pyo;Choung, Won-Myung;You, Gil-Sung;Lee, Won-Kyung;Kuk, Dong-Hak;Cho, Il-Je
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.1
    • /
    • pp.77-85
    • /
    • 2006
  • A demonstration facility for an advanced spent fuel conditioning process (ACP) is under construction at KAERI. In this hotcell facility, the rear door is frequently used since all process equipment and materials are taken in and out only through the rear door. Therefore , both the structural safety and stability of the door are essentially required for the safety of ACP facility. In this paper, the finite element analysis has been performed to investigate the structural safety under the impact condition between the rear door and the door frame. Also the possibility of the rear door being tumbled over by the impact force or the inertia force under a sudden stop conditon has been evaluated. The analysis results demonstrate that the structural safety and stability of the rear door are sufficiently assured for both the impact and the accidential stop conditions.

  • PDF

Research on Design Capacity Evaluation of Low Impact Development according to Design Criteria (저영향개발 시설 설계 기준에 따른 용량 평가 방법 연구)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.24 no.1
    • /
    • pp.59-67
    • /
    • 2022
  • The interest in LID facilities is increasing worldwide for recovery of natural water cycle system to destroy by urbanization. However, problems are raised when installation of LID because comprehensive analysis about design capacity adequacy of LID facilities was not conducted completely. In this research, removal efficiency and design volume adequacy of LID facilities were analyzed based on rainfall monitoring data in four LID facilities(Vegetated Swale, Vegetative Filter Strip, Bio-Retention and Permeable Pavement). As a result, group of LID facility designed on WQV was shown higher flow(37%) and pollutants(TSS, BOD, TN and TP) removal efficiencies(20 ~ 37%) than group of LID facility designed on WQF. SA/CA graph was drawn for evaluation of design volume adequacy based on rainfall monitoring data. In this SA/CA graph, coefficient of determination show over 0.5 in all parameter, especially, Flow and TP were show over 0.95. And, 'SA/CA & L/CA' graph considering difference of structure mechanism in LID facility suggested in this research was confirmed that improved coefficient of determination in flow, TSS and TP than SA/CA graph. According to this research results, feasibility of applying 'SA/CA & L/CA' graph for evaluation of design volume adequacy in LID facility, and it is necessary to follow up research for generalization and normalization.

Technical Management Processes for Large National R&D Projects : Focused on Pyro Project (대형 국가 R&D 프로젝트의 기술관리 프로세스 : 파이로 프로젝트를 중심으로)

  • Kim, Jeong-Guk;Ko, Won-Il;Ku, Jeong-Hoe;Nam, Hyo-On
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.13 no.2
    • /
    • pp.34-41
    • /
    • 2017
  • The Pyro project, one of the large national R&D project to construct Korea Advanced Pyroprocessing Facility (KAPF), which has many goals such as development of pyro technology and process equipment, design of equipment and facility, construction, and test operation, is now under research and development. To reduce uncertainty and risk of such complex project, the technical management processes in systems engineering standards and NASA handbook were reviewed, and then the ten common technical management processes were selected for the large national R&D project to meet its goal successfully. And the essential technical management processes were finally suggested for Pyro project in consideration of current situation of the project.

CHARACTERISTICS OF A NEW PNEUMATIC TRANSFER SYSTEM FOR A NEUTRON ACTIVATION ANALYSIS AT THE HANARO RESEARCH REACTOR

  • Chung, Yong-Sam;Kim, Sun-Ha;Moon, Jong-Hwa;Baek, Sung-Yeol;Kim, Hark-Rho;Kim, Young-Jin
    • Nuclear Engineering and Technology
    • /
    • v.41 no.6
    • /
    • pp.813-820
    • /
    • 2009
  • A rapid pneumatic transfer system (PTS) for an instrumental neutron activation analysis (INAA) is developed as an automatic irradiation facility involving the measurement of a short half-life nuclide and a delayed neutron counting system. Three new PTS designs with improved functions were constructed at the HANARO research reactor in 2006. The new system is composed of a manual system and an automatic system for both an INAA and a delayed neutron activation analysis (DNAA). The design and basic conception of a modified PTS are described, and the functions of system operation and control, radiation protection and emissions of radioactive gas are improved. In addition, a form of capsule transportation of these systems is tested. The experimental results pertaining to the irradiation characteristics with variation of the neutron flux and the temperature of the irradiation position with the irradiation time are presented, as is an analysis of the reference material for analytical quality control and uncertainty assessments.

SHIELDING PERFORMANCE OF A NEWLY DESIGNED TRANSPORT CASK IN THE ADVANCED CONDITIONING SPENT FUEL PYROPROCESS FACILITIY

  • Park, Chang-Je;Jeong, Chang-Joon;Min, Deok-Ki;Kang, Hee-Young;Choi, Woo-Seok;Lee, Joo-Chan;Bang, Gyeoung-Sik;Seo, Ki-Seog
    • Nuclear Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.319-326
    • /
    • 2008
  • To transport process wastes efficiently from the Advanced Spent Fuel Conditioning Pyro-process Facility (ACPF) at the Korea Atomic Energy Research Institute (KAERI), a new hot cell cask has been designed based on an existing hot cell padirac transport cask, with not only a neutron absorber for improved shielding capability, but also a docking facility for an easy docking system. In the new hot cell cask, two kinds of materials have been considered as shielding materials, polyethylene and resin. To verify the transport compatibility of the waste and spent fuel for the ACPF, neutron and photon shielding calculations were performed using the MCNPX code. The source term was evaluated by the ORIGEN-ARP code system based on spent PWR fuel. From the calculation, it was found that the maximum surface dose rates of the hot cell cask with the two candidates were estimated within the limit (2 mSv/hr).

A Study on Used Colors Characteristic of Case Study for Children Play Therapy Center (국내.외 놀이치료 시설의 사례분석을 통한 사용 색채 특성에 관한 연구)

  • Choi, Jin-Hee
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.4
    • /
    • pp.29-36
    • /
    • 2011
  • This study aims to be the useful resources for selecting play therapy facility in the future by analysis of used colors in the play therapy facility as the subsequent studies of the thesis of KIID in 2010, titled 'Study on the planning factors of case study for children's play therapy center'. As research method of this study, the overall understanding about play therapy facility was improved through theoretical considerations, and it was about the Moon-Spencer's theory of color harmony which will be used for the framework of case study. In Section 3, the field trips at 6 facilities were conducted as the case research and the data research through website was conducted for case study. Moon-Spencer's theory of color harmony used the Munsell's color Order System, so after measuring CMYK value of the picture for the case research through photo shop, the color, brightness and saturation were measured through Munsell Conversion program. The following three kinds of features were drawn by research of the harmony and disharmony of used colors for the cases after substituting the theory of color harmony through the measured color. brightness, and saturation. First. series Y and YR were used mainly for warm image as the concept of play therapy room. Second, the various colors were used for comfortable image like home. But the various patterns were used by mixing for the therapy room F, so it gives confusing impression. Third, series YR and achromatic color as the color of wood were used unavoidably for using materials of manufactured goods.

A Study on the Test Method of Local Information Processing Device in Digital Substation Based on IEC 61850 (IEC 61850 기반 디지털변전소 현장정보처리장치 시험 방법에 관한 연구)

  • Kim, Nam-Dae;Kim, Woo-Jung;Lee, Nam-Ho;Kim, Seok-Kon;Jang, Byung-Tae
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.3
    • /
    • pp.253-257
    • /
    • 2020
  • The local information processing devices are devices that process information by converting voltage, current, and digital electric signals from legacy-type power facility into IEC 61850 based data. It acquires and processes the operation information of legacy-type power facility, performs control of power facility, and interlock function using internal logic. In particular, the time to convert data to process input and output information for a device is important because a number of protection relay input and output signals are handled by only one device. This paper introduces test methods and cases for measuring IEC 61850 communication function and input/output data conversion time of local information processing device.