• Title/Summary/Keyword: Research Facility

Search Result 4,470, Processing Time 0.035 seconds

The Survey Analysis on the Exterior Connection Facility Conditions of University Campuses for Handicapped Students (장애학생을 위한 대학캠퍼스 옥외매개시설의 실태에 관한 조사 분석)

  • Choi, Jang-Soon
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.14 no.1
    • /
    • pp.21-28
    • /
    • 2012
  • Campus facilities were recently remodeled to provide the substantial learning rights of handicapped students in many campus to embody the dignity and value as man. So this study aims to identify the exterior connection facilities for handicapped students of S and D campuses. The summaries of this research are as follows. Installations of even crossing area(1.5mx1.5m) per 50m and even rest area(1.5mx1.5m) per 30m in walking or access ramp. Improving in accordance with exterior connection facility repairing master plan in S campus. Bringing down an angle degrees of the inclined walking or access ramp in D campus. Installation of exterior braille guide sign for blind students. All handicapped students must be guaranteed the same learning rights as normal men to remove obstacles as the upper mentioned imperfections in using exterior campus facilities.

A Study on Refrigerate Warehouse Facility Performance Planning for Picking and Replenishing Facility Using Simulation Method (냉장창고설비의 픽킹 및 재 보충설비계획문제의 연구)

  • Hwang Heung Seok;Jo Gyu Seong;Choe Bae Seok
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2003.05a
    • /
    • pp.1035-1041
    • /
    • 2003
  • Recent studies among various activities taking place in order-picking warehouse system have shown various researches to reduce the order-picking costs occupying more than half the total costs. One way of improving the warehouse system performance is to separate from a picking area and a reserve area in one unit rack. This study is concerned on the performance evaluation model for picking and replenishing facility of refrigerated warehouse using simulation method. In this study, we developed a mathematical model to compute the system performance solve this problem using simulation method. We demonstrate the system performance using AutoMod Simulator and verify the results to compare mathematical results of the system performance of warehouse system. A systematic approach proposed n this study for an optimal planning of order-picking warehouse is known as an effective method for planning of order-picking warehouse and a performance evaluation problem considering both picking and replenishment.

  • PDF

Application of Disaster Information Classification System for Disaster Management (시설물 재해관리를 위한 재해정보분류체계 구성 방안)

  • Kang Leen-Seok;Park Seo-Young;Moon Hyoun-Seok
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.4 s.35
    • /
    • pp.335-342
    • /
    • 2006
  • Disaster management system should be built for minimizing damage factor that affects to construction facility from natural disaster. It could be classified by three categories such as disaster prevention, damage survey and recovery phases. For an integrated disaster management system, a disaster information classification system(DICS) is necessary for the reasonable disaster information management. This study suggests an integrated DICS that includes disaster type classification, facility type classification and information type classification for disaster management service. The applicability of suggested DICS is verified by railway facility and the research result could be used as a basic information system for national disaster management system.

의약품 제조시설의 포름알데히드가스 훈증살균과 최근 실내무균화방법의 동향

  • 한국공기청정협회
    • Air Cleaning Technology
    • /
    • v.23 no.3
    • /
    • pp.34-43
    • /
    • 2010
  • In most productive facility of pharmaceutical companies, the fumigation using formaldehyde gas has been put into operation. Because formaldehyde gas is so bactericidal as to sterilize bacterial spore which can not be sterilized with usual disinfectants, it has been used for fumigation in many facilities such as facility of experimental animals, research institute and productive facility of pharmaceutical companies which are required to be high level of biological clean. However, the use of formaldehyde is recently under the strict management because of its causing of sick house and carcinogenesis. We introduce the conditions of sterilization using formaldehyde gas, the examples of sterilization using formaldehyde gas in a pharmaceutical manufacture and the problems of use of formaldehyde against environments and health. Further, we describe the characteristics and future subjects of the sterilization method using gasified oxidants such as hydrogen peroxide, peracetic acid and chlorine oxide.

  • PDF

The Semi-Transparent Diamond Monochromator at the ESRF Troika Beamlines

  • Mattenet Muriel;Konovalov Oleg;Madsen Anders;Grubel Gerhard
    • Macromolecular Research
    • /
    • v.14 no.4
    • /
    • pp.473-477
    • /
    • 2006
  • The above described semi-transparent monochromators have been operational since 1997. Four units are permanently operating at the ESRF beam line ID14. Two units are in continuous operation at ID 10 and one unit is installed at the APS beamline 8-ID in USA. The water cooling of the crystals is currently being revised and above we showed that improvements most likely are possible by using micro fluidics techniques. Further tests will be performed in collaboration with the CEA-France and tested at ESRF. Parallel developments including nanofluids as coolants are under evaluation. Combination of nanofluidics and microfluidics cooling devices are under study. The authors are grateful to C. Gillot and J-A. Gruss for useful discussions and advices, and to S.Mcheik for his work on the thermal model.

Design of the Full-Scale Fire Safety Evaluation Facility for Railroad Vehicle Fire (철도차량 실대형 화재안전 성능평가 장치 설계)

  • Yoo, Yong-Ho;Kim, Heung-Youl
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.222-225
    • /
    • 2008
  • To prove a lot of technical difficulties related to the safety management of a railroad fire effectively, we design for the full-scale fire test facility of the railroad vehicle. It will be consist of major 3 part - duct system with smoke cleaning system, measuring section and gas analysis system. The CFD simulation was also carried out to design of the hood and duct system optimization. The results will be help for basic research of the railroad fire safety.

  • PDF

Ant Algorithm Based Facility Layout Planning (설비배치계획에서의 개미 알고리듬 응용)

  • Lee, Sung-Youl;Lee, Wol-Sun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.13 no.5
    • /
    • pp.142-148
    • /
    • 2008
  • Facility Layout Planning is concerned with how to arrange facilities necessary for production in a given space. Its objective is often to minimize the total sum of all material flows multiplied by the distance among facilities. FLP belongs to NP complete problem; i.e., the number of possible layout solutions increases with the increase of the number of facilities. Thus, meta heuristics such as Genetic Algorithm (GA) and Simulated Annealing have been investigated to solve the FLP problems. However, one of the biggest problems which lie in the existing meta heuristics including GA is hard to find an appropriate combinations of parameters which result in optimal solutions for the specific problem. The Ant System algorithm with elitist and ranking strategies is used to solve the FLP problem as an another good alternative. Experimental results show that the AS algorithm is able to produce the same level of solution quality with less sensitive parameters selection comparing to the ones obtained by applying other existing meta heuristic algorithms.

  • PDF

Minipigs as Laboratory Animals: Facility Management and Husbandry

  • Koo, Ok-Jae;Jang, Goo;Lee, Byeong-Chun
    • Reproductive and Developmental Biology
    • /
    • v.36 no.1
    • /
    • pp.79-85
    • /
    • 2012
  • Minipigs are regarded as one of the most important laboratory animal in that anatomical and physiological properties are similar to human and their reproduction efficiency is relatively higher compared to other large animal species. Particularly, several diseases that cannot be mimicked in rodent models are successfully occurred or induced in pig models therefore it has been interested in a valuable model for human diseases. Pigs are also 'standard' species in xenotransplantation research. To maximize experimental outcome using minipigs, establishment and management of proper animal facility, right animal husbandry and control of pathogens are very important. In this review, we summarized several international guidelines related with minipigs published by several companies or governments and discuss optimal conditions for providing informative ideas to the researchers who want to use minipigs in their future studies.

Simplified Synthetic Testing Facility with Modified TRV Circuit

  • Chong, Jin-Kyo;Lee, Kyung Seob;Lee, Chang-Hoon;Kim, Gyu-Tak
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.881-885
    • /
    • 2018
  • In order to develop a gas circuit breaker (GCB), the breaking performance of the short line fault (SLF) should be prioritized over that of the breaker terminal fault (BTF). In brief, it is necessary to evaluate the thermal characteristics of the insulating gas that is filled in a GCB. In the process of developing a GCB, many companies use the simplified synthetic testing facility (SSTF).In order to evaluate the SLF breaking performance of a GCB with a long minimum arcing time, a modifications to the conventional SSTF was proposed. In this study, we developed the SSTF with a modified transient recovery voltage circuit. The performance of the newly developed SSTF was verified by an $L_{90}$ breaking performance test on a rating combination of 170 kV, 50 kA, and 60 Hz.

A STUDY ON DEGREASING DETERGENT AND METHOD FOR THE IPP TEST FACILITY

  • Kim Yong-Wook;Lee Jung-Ho;Kang Sun-Il;Kim Sang-Heon;Oh Seung-Hyub
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.10b
    • /
    • pp.262-265
    • /
    • 2004
  • As a cryogen, LOx is a light blue, odorless, transparent liquid. Also it is not shock sensitive and does not decompose. However, it is a strong oxidizer and will vigorously support combustion. Therefore all harmful contaminants (such as grease, oil, fingerprint and organic materials) that could cause malfunctions, fires, or explosions in a oxygen environments must be completely removed prior to the introduction of oxygen. Especially, grease ingredient located inside of the LOx supply line, pipe and PHS (Pneumo-Hydraulic System) part can make drastic chemical reaction with oxygen. Therefore, to protect rapid reaction such as explosion, grease ingredient must be surely eliminated by a regular and irregular degreasing. Study on the availability, effectiveness and selection of degreasing detergents and method is described in this paper, and it will be useful for the construction and management of IPP test facility.

  • PDF