• Title/Summary/Keyword: Research Facility

Search Result 4,470, Processing Time 0.031 seconds

Management and Operation of Apartment Community Facilities and Post Occupancy Evaluation - Focused on the R Apartments Complex in Daegu - (아파트 단지 내 커뮤니티 시설의 운영 실태와 거주 후 평가 - 전문관리자 운영의 대구 R아파트 단지를 중심으로-)

  • Kang, Soon-Joo
    • Journal of the Korean housing association
    • /
    • v.21 no.4
    • /
    • pp.111-120
    • /
    • 2010
  • This study examines the effectiveness of a new community facility operation and management system that were implemented by one of the major construction companies. This system was an unprecedented approach in a sense that it provided not only necessary facilities but also a specialized management staff, an operational manual, and a subsidy for various programs. According to POE conducted among the residents, it can be concluded that the residents' satisfaction will be increased under the following conditions; 1) when a program manual associated with the community facility is provided, 2) when there is a professional staff who can coordinate various programs effectively, 3) when the facilities are well designed in accordance with the program requirements, 4) when the users adhere to regulations and management standards, 5) when all three components- i.e. facility, people and programs- are well coordinated, and 6) when affordable user fees are charged. This research assures that professional management staff and well-planned management system play a significant role in the enhancement of the residents' satisfaction as well as vitalizations of the community.

A Study on the Circulation System of Biosafety Level 4 Laboratory Facilities (생물안전 4등급(BL4) 실험시설의 동선계획에 관한 연구)

  • Kwon, Soonjung;Choi, Hongbin
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.17 no.1
    • /
    • pp.23-32
    • /
    • 2011
  • Recently, with the advent of high risk infectious agent such as the Ebola virus, SARS, special research facilities dealing with such dangerous pathogenic are drawing attention gradually. Especially, this kind of facilities can be called BL4(Biosafety Level 4) facility. At the moment, Korean government is going to construct BL4 institute in order to handle efficiently such kind of pathogen. However, there are no proper design guidelines for BL4 facility. This paper proposes circulation system of BL4 facility on the basis of analysis of existing BL4 guidelines of Canada, and Korean BL3 facilities. The outcomes of this study are as follows. At first, functional areas of BL4 facilities have been divided into three categories according to the hazard level ; dangerous area, transitional area, and ordinary area. Secondly, circulation system of BL4 facility has been explored as a form of diagram according to the circulating subjects. These include human, laboratory animals, hazardous pathogen, equipments and cloth. This study has some limitations in that it lacks empirical evidences and concrete SOPs(Standard Operating Procedure). Despite of some weaknesses, it is expected to give some preliminary guidelines for the design of circulation system in BL4 facilities.

Design of an Altitude Test Facility for Turbo Shaft Engine

  • Choi, Young-Hwan;Park, Sang-Joon;Lee, Joon-Won;Kim, Chun-Taek;Cha, Bong-Jun;Ahn, Iee-Ki
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.173-181
    • /
    • 2008
  • Gas turbine engine for aircraft are usually operated at the altitude condition which is quite different from the ground condition. In order to measure the precise performance data at the altitude condition, the engine should be tested at the altitude condition by a real flight test or an altitude simulation test with an altitude test facility. In this paper describes the design of altitude test facility for turbo shaft engine. This facility will be located in test cell #2 at the Korea Aerospace Research Institute. Test Cell #2 will be used for altitude testing engines with mass flow rate up to 40kg/s and inlet temperatures in the range from $-65^{\circ}C$ to $200^{\circ}C$. The existing compressor/exhauster station with heater & cooler system will be used to simulate altitude conditions in Test Cell #2.

  • PDF

Conceptual Design of KSLV-II 3rd Stage Engine Test Facility (한국형발사체 3단 엔진 연소시험설비 개념설계)

  • Kim, Seung-Han;Chung, Yong-Gap;Han, Yeoung-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.484-488
    • /
    • 2012
  • Korea Aerospace Research Institute (KARI) performed the conceptual design of rocket engine test facility for the development and qualification of the 3rd stage liquid rocket engine for KSLV-II. The 3rd stage rocket engine test facility, which are to be constructed at Naro Space Center, will supply propellants and high-pressure gases to engine for firing test at ground and altitude conditions. The altitude test condition is obtained using a supersonic diffuser operated by the self-ejecting jet from the liquid rocket engine.

  • PDF

Specific Process Conditions for Non-Hazardous Classification of Hydrogen Handling Facilities

  • Choi, Jae-Young;Byeon, Sang-Hoon
    • Safety and Health at Work
    • /
    • v.12 no.3
    • /
    • pp.416-420
    • /
    • 2021
  • Hazardous area classification design is required to reduce the explosion risk in process plants. Among the international design guidelines, only IEC 60079-10-1 proposes a new type of zone, namely zone 2 NE, to prevent explosion hazards. We studied how to meet the zone 2 NE grade for a facility handling hydrogen gas, which is considered as most dangerous among explosive gases. Zone 2 NE can be achieved considering the grade of release, as well as the availability and effectiveness of ventilation, which are factors indicative of the facility condition and its surroundings. In the present study, we demonstrate that zone 2 NE can be achieved when the degree of ventilation is high by accessing temperature, pressure, and size of leak hole. The release characteristic can be derived by substituting the process condition of the hydrogen gas facility. The equations are summarized considering relation of the operating temperature, operating pressure, and size of leak hole. Through this relationship, the non-hazardous condition can be realized from the perspective of inherent safety by the combination of each parameter before the initial design of the hydrogen gas facility.

A Phenomenological Study on the Experiences of Long Term Care Facility Workers during the COVID-19 Pandemic (코로나19 대유행 시 일 노인요양시설에 종사하는 요양보호사의 직무경험에 대한 연구)

  • Kim, Ji Hyang;Han, Suk Jung
    • Journal of Korean Public Health Nursing
    • /
    • v.35 no.1
    • /
    • pp.33-46
    • /
    • 2021
  • Purpose: The purpose of this study was to understand the experiences of those who take care of the elderly at a long-term care facility during the COVID-19 pandemic. Methods: Colaizzi's phenomenological research method was applied to describe the meaning and nature of the experiences of eight workers in an elderly care facility during the COVID-19 crisis. Results: Studies have shown that these workers experienced 'fear from infectious disease' and had the opportunity to 'reflect upon life changed by infectious disease.' They also worked together to overcome the crisis by 'protect nursing home with the nurses at COVID-19 sites' and felt 'safety from the nursing home,' and experienced 'a strong sense of calling for the job' through the crisis. Conclusion: This study is the first of its kind conducted in Korea on workers in an elderly care facility. The results indicate that it is necessary to supports these workers with practical useful education, counseling, and emotional support during the epidemic.

PILLAR: Integral test facility for LBE-cooled passive small modular reactor research and computational code benchmark

  • Shin, Yong-Hoon;Park, Jaeyeong;Hur, Jungho;Jeong, Seongjin;Hwang, Il Soon
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3580-3596
    • /
    • 2021
  • An integral test facility, PILLAR, was commissioned, aiming to provide valuable experimental results which can be referenced by system and component designers and used for the performance demonstration of liquid-metal-cooled, passive small modular reactors (SMRs) toward their licensing. The setup was conceptualized by a scaling analysis which allows the vertical arrangements to be conserved from its prototypic reactor, scaled uniformly in the radial direction achieving a flow area reduction of 1/200. Its final design includes several heater rods which simulate the reactor core, and a single heat exchanger representing the steam generators in the prototype. The system behaviors were characterized by its data acquisition system implementing various instruments. In this paper, we present not only a detailed description of the facility components, but also selected experimental results of both steady-state and transient cases. The obtained steady-state test results were utilized for the benchmark of a system code, achieving a capability of accurate simulations with ±3% of maximum deviations. It was followed by qualitative comparisons on the transient test results which indicate that the integral system behaviors in passive LBE-cooled systems are able to be predicted by the code.

A Study on the Architectural Status and Improvement of Korean Used Car Trade Facility - based on Benchmarking of Japanese Used Car Trade Facilities - (한국 중고차 거래소 건축 현황과 개선방안 연구 - 일본 중고차 거래소의 벤치마킹을 중심으로 -)

  • Song, Kyuman
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.6
    • /
    • pp.47-58
    • /
    • 2019
  • According to the Korea Ministry of Transportation report in 2015, domestic used car trade (3.66million) is twice the number of new car sales (1.84million). However, contrary to the quantitative growth of the used car trading volume, chaotic used-car market practice has not been improved and also, space that holds these markets (facilities) has remained at a very low level of quality. Lemon Market, asymmetry of information, false bait, tout, dual contracts, negative words that qualify the used car market information are still in place. The aim of this study was to understand the unique circumstances of the used car sales market distinguished from new cars, and to analyse the problems of recent domestic used car market facilities and afterwards to draw guidelines for new used car facility architecture. Through literature review, surveys, the characteristics of domestic used car market have been organised and field research and competitive analysis of the Korea used car market architecture is followed. As a result, empirical guideline for Korea used-car market facility is introduced.

Study on Legal Issues of Facility Management of Children's Swimming Pool

  • KWON, Yeon Taek;SEO, Myung Seok;SEO, Won Jae
    • Journal of Sport and Applied Science
    • /
    • v.3 no.1
    • /
    • pp.19-25
    • /
    • 2019
  • Purpose: Children's swimming pools are picking up faster than the other types of swimming pool. Yet, safety law-related studies are still lack. This study is to review legal status of children's swimming pool in Korea and to discuss the related legal issues for safety management of children's swimming pool. Research design, data, and methodology: The study reviewed law and clauses for sport facility management and related legal clauses with chilren's swimming pool management, and sport facility-related articles. Results: Safety management of children's swimming pool should currently follow law for sport and physical education facility management because of no its own legal norm for children's swimming pool. Given this, specific law and clauses for children's pool management need to be legislated to prevent risks for children and to satisfy specific safety factors considering careless behavior of children. Conclusions: Regarding this, the study points out five suggestions. First, law should be established to make notification of safety rules mandatory and this notification should be placed in the pool. This notification would be better effective if it is visualized. Second, according to law, safety 7 rules of children' s swimming pool need to be legistrated and educated for pool managers to obey them. Pool managers could also add their own rules to the 7 rules. Finally, preparation of emergency kits and safety devices need to be mandatory in the pool. Further implications were discussed.

Application and Maintenance Strategies for Eco-Friendly Facilities in Landscape Trees Nurseries

  • Young Sun Seok;O Man Kwon;Yun Eui Choi
    • Journal of Forest and Environmental Science
    • /
    • v.40 no.2
    • /
    • pp.151-165
    • /
    • 2024
  • Recently, as the number of landscaping plant nurseries have increased, environmental problems such as topographical damage due to indiscriminate changes in land use, increased non-point pollution, and increased impervious areas are also occurring. In this study, we propose eco-friendly facilities and a detailed maintenance manual that can enhance the eco-friendliness and scenic beauty of landscaping plant nurseries that are increasingly located near cities. By exploring previous reports on eco-friendly facilities and related laws, we cataloged the types of eco-friendly facilities, and by referring to examples of eco-friendly facilities introduced in overseas cases and the environmental functions of agriculture, we cataloged the types of eco-friendly facilities suitable for introduction in plant nurseries. The selected facilities are rain gardens, tree boxes, vegetated filter beds, bio-retention, infiltration trench, infiltration tanks, permeable pavements, and sand filtration systems. The maintenance tasks of eco-friendly facilities were categorized and management plans were proposed, which is expected to be utilized as a basic data to prepare eco-friendly space planning and operation management plans when creating a landscape plant nurseries in the future.