• Title/Summary/Keyword: Research Facility

Search Result 4,470, Processing Time 0.035 seconds

Development of Hard-wired Instrumentation and Control for the Neutral Beam Test Facility at KAERI

  • Jung Ki-Sok;Yoon Byung-Joo;Yoon Jae-Sung;Seo Min-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.359-365
    • /
    • 2006
  • Since the start of the KSTAR (Korea Superconducting Tokamak Advanced Research) project, Instrumentation and Control (I&C) of the Neutral Beam Test Facility (NB-TF) has been striving to answer diverse requests arising from various facets during the project's development and construction phases. Hard-wired electrical circuits have been designed, tested, fabricated, and finally installed to the relevant parts of the system. In relation to the vacuum system I&C, controlling functions for the rotary pumps, a Roots pump, two turbomolecular pumps, and four cryosorption pumps have been constructed. I&C for the ion source operation are the temperature and flow rate signal monitoring, Langmuir probe signal measurements, gradient grid current measurements, and arc detector circuit. For the huge power system to be monitored or safely operated, many temperature measurement functions have also been implemented for the beam line components like the neutralizer, bending magnet, ion dump, and calorimeter. Nearly all of the control and probe signals between the NB test stand and the control room were made to be transmitted through the optical cables. Failures of coolant flow or beam line vacuum pressure were made to be safely blocked from influencing the system by an appropriate interlock circuit that will shut down the extraction voltage application to the system or prevent damages to the vacuum components. Preliminary estimation of the beam power through the calorimetric measurement shows that 87.9% of the total power of the 60kV/18A beam with 200 seconds duration is absorbed by the calorimeter surface. Most of these I&C results would be highly appropriate for the construction of the main NBI facility for the KSTAR national fusion research project.

HY Simplified Synthetic Test Facility (한양대학교 간이차단 합성시험설비구축)

  • Chang, Yong-Moo;Hwang, Ryul;Kim, Cheol-Ho;Lee, Bang-Wook;Koo, Ja-Yoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.220-220
    • /
    • 2009
  • We are developing of the evaluation technique and system for testing the performance of circuit breaker using Simplified Synthetic circuit. This facility specification is up to 90[kApeak] and up to 300[kVpeak]. It is possible to verify the interrupting capability by using low-energy and reduce the development period and the cost.

  • PDF

Effects of Different Calm Conditions on the Radiation Exposure Due to the Operation of a Nuclear Facility at KAERI Site

  • Hwang, Won-Tae;Han, Moon-Hee;Kim, Eun-Han;Suh, Kyung-Suk;Gyuseong Cho
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.28-33
    • /
    • 1996
  • Wind-speed has much effect on the dispersion of the radioactive effluents released into the atmosphere. Accurate measurement of low wind-speeds is very important for the realistic assessment of radiation exposure. The objective of this study is to analyze the effects of different calm conditions on the radiation exposure due to the normal operation of a nuclear facility at KAERI (Korea Atomic Energy Research Institute) site. When calm condition is changed from 0.5 m/sec to 0.21 m/sec, the effects on radiation exposure show a distinct difference.

  • PDF

Simple Synthetic Testing Facility Using LC Resonance Circuit (LC 공진회로를 이용한 간이 합성시험설비)

  • Park, J.H.;Shin, Y.J.;Park, K.Y.;Ryu, H.G.;Kim, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.631-635
    • /
    • 1993
  • This paper shows the procedure to determine the physical variables of the simple synthetic testing facility using LC resonance circuit and presents the calculated results of those variables for the LC resonance circuit which can be used to test circuit breakers up to 36kV 40kA class. Attention has also been paid to the advantages of the LC resonance circuit compared with the method adopting short-circuit generator for the development of circuit breakers.

  • PDF

Heat transfer characteristics of redan structure in large-scale test facility STELLA-2

  • Yoon, Jung;Lee, Jewhan;Kim, Hyungmo;Lee, Yong-Bum;Eoh, Jaehyuk
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1109-1118
    • /
    • 2021
  • The construction of STELLA-2 facility is on-going to demonstrate the safety system of PGSFR and to provide comprehensive understanding of transient behavior under DBEs. Considering that most events are single-phase natural circulation flow with slow transient, STELLA-2 was designed with reduced-height of 1/5 length scale. The ratio of volume to surface area in the vessel can relatively increase resulting in excessive heat transfer. Therefore, a steady-state thermal-hydraulic analysis was performed and the effect of design change to reduce the heat transfer through redan was investigated. The heat transfer through single wall redan in STELLA-2 was 3% of the core power, comparable to 1% of the core power in PGSFR. By applying the insulated redan, about 70% of decrease effect was observed. The effect on transient behavior was also evaluated. The conclusion of this study was directly applied to the STELLA-2 design and the modified version is under construction.

The analysis of Complex Type and the Facility Status of Community Mixed-support Facility (공동체복합지원시설의 시설현황 및 복합유형 분석)

  • Kim, Sumi;Kim, Suk-Young
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.6
    • /
    • pp.507-517
    • /
    • 2013
  • Welfare desire has been diversified according to the increase of economic level and rapid social change. The desire for comprehensive service on culture, medical, mental and information level has appeared. Accordingly, it is necessary to establish an integrated community mixed-support facility, a space of accepting administration, welfare, leisure, culture and informatization request in a small local community in the future. The community mixed-support facility is a meeting place of local resident for information change, various basic service and ultimately for activation of community in order to contribute to regeneration and activation of existing urban core. Thus, this study figured out general status of community mixed-support facility and physical mixed type and analyzed spatial characteristics. Current community mixed-support facility has insufficient program and space to participate in by local residents and to accommodate mixed function. The future planned community mixed-support facility must secure multiple opportunities for various types of life by returning time and cost to user through the introduction of creative mixed concept. While reflecting unique local characteristics, and considering diversity of users, it needs to make mixed facility to cope with social changes. This study is limited in that the study reached a conclusion by survey and analysis only. However, it is expected that the result can be used as basic research data for the planning of community mixed-support facility to cope with living conditions of local residents or realistic requirements.

Mach 5 Performance Tests of Scramjet Engine Intake Using Free-jet Type Ground Propulsion Test Facility (자유제트형 지상추진 시험설비를 사용한 스크램제트 엔진 흡입구의 마하 5 성능시험)

  • Lee, Yang Ji;Yang, Inyoung;Lee, Kyung Jae;Oh, Jung Hwan;Choi, Jin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.4
    • /
    • pp.10-20
    • /
    • 2022
  • The performance analysis test of the scramjet engine intake was conducted under the Mach 5 condition of the scramjet engine test facility, a free-jet ground test facility of the Korea Aerospace Research Institute. A pitot/static pressure rake installed at the rear of the isolator was designed and manufactured to measure the total pressure recovery rate and mass capture ratio, which are typical performance factors of the scramjet engine intake. The effect of the rake mounted at the rear of the isolator on the intake, the performance analysis measured by the rake, and the change in wall static pressure distribution according to the angle of attack were performed. Finally, the point at which the intake unstart occurred was confirmed by using the rear back pressure adjusting device, which simulates pressure rise in the combustor, and the results are summarized in this paper.