• Title/Summary/Keyword: Research Facility

Search Result 4,470, Processing Time 0.036 seconds

Importance Factor Analysis on Transfer Facilities by Considering Characteristics of Urban Railway Station (도시철도역사의 유형별 특성을 고려한 환승시설의 중요도 분석)

  • Kim, Hwang Bae;Ahn, Woo-Young;Lee, Sang Hwa
    • Journal of Korean Society of Transportation
    • /
    • v.32 no.5
    • /
    • pp.487-496
    • /
    • 2014
  • Much research has been actively done so far on the inconvenience of each urban railway station; however, Research is on importance factor analysis on transfer facilities by considering characteristics of railway stations is relatively insufficient. In this study, a novel method of finding causality between transfer facilities(movement, information, comfortability, etc,) in terms of demands and platform types is provided by using SEM(Structural Equation Model). The results of SEM analysis show that a large demand transfer station if combined with island and segregate platform types, has a higher importance factor with respect to information facility, movement facility position and comfortability. In addition, a medium demand transfer station if combined with separate and separate platform types has a higher importance factor with respect to information facility, movement facility and comfortability.

3D/4D CAD Applicability for Life Cycle Facility Management (3D/4D CAD를 통한 시설물 생애주기 관리 유용분야 도출)

  • Park, Jung-Jun;Kim, Chang-Yoon;Kim, Hyoung-Kwan
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.291-296
    • /
    • 2008
  • For the past two decades, 3D/4D CAD research has heel mainly focused on the design and construction phase of a facility life-cycle. However, there has been a general notion that the strength of 3D/4D CAD lends itself to other phases such as planning, operation and maintenance. In this research, a 3D/4D CAD model was generated in a commercial software platform. Then, the traditional 1:fe cycle facility management procedures are reviewed to, see any possible improvement opportunity with the 3D/4D CAD model as an example. A focus group interview, in conjuction with an extensive literature review, produced the list of area where 3D/4D CAD model could significantly benefit the traditional life cycle facility practices. Finally, a questionnaire-based survey was conducted with 155 respondents to statistically verify the feasibility of 3D/4D CAD for life cycle facility management.

  • PDF

Development Test of Alcohol Burner for Turbopump Real-propellant Test Facility (터보펌프 실매질 시험설비를 위한 알코올버너 개발시험)

  • Kim, Jin-Sun;Han, Yeoung-Min;Ko, Youngsung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.5
    • /
    • pp.79-86
    • /
    • 2014
  • A turbopump real-propellant test facility(TPTF) is to verify the performance of a turbopump unit(TPU) based on liquid oxygen and kerosene. One of the most important sub-facilities is a hot-gas generation system which makes the driving force of the TPU with an alcohol burner. The alcohol burner generates the required flow rates and temperature at the facility using high pressure air and ethanol. In the study, the verification tests of the alcohol burner which was manufactured entirely with domestic technology were performed and fabrication technique and operation skill for the burner could be obtained ahead of the construction of the facility. Two burners will be operated simultaneously for the real-propellant test of 75tf class turbopump and satisfy the power requirement from the turbine of the TPU.

Research on the Trend of Welfare of Children with Disabilities and Facility Reorganization in Japan - Focused on Medical-type Facility for Children with Disabilities (일본의 장애아를 위한 복지의 동향과 시설재편에 관한 연구 - 의료형 장애아 입소시설을 중심으로)

  • Bae, Minjung;Takemiya, Kenji
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.3
    • /
    • pp.67-74
    • /
    • 2019
  • Purpose: In 2012, the Child Welfare Act was revised to provide better support to children with severe disabilities in Japan. Previously, inpatient facilities had been classified according to the type of disabilities of patients. After the revision of the Act, however, these facilities were assigned into the category of "medical-type facilities for children with disabilities", or "welfare-type facilities for children with disabilities." The focus of the study is to evaluate the reorganization of the Child Welfare Act and to analyze the new layout of Center K after its transition from a facility for children with motional disabilities to a medical-type facility for children with disabilities. Methods: A literature review was conducted to identify the trend in the treatment for persons with disabilities and the process of policy making in Japan. Field research was performed twice in 2015 and 2016, before and after the renovation of the Center K facilities depending upon the revision of the Child Welfare Act. Results: There is an increasing tendency of the population of persons with disabilities in Japan, and the severity level of disability of children with disabilities. In the case of Center K, two types of ward constructed to meet the two types of disability has been reconstructed into three types of unit following the various severity level of disability. Implications: As a result, it could be argued that it is also necessary in Korea to reorganize the facilities for persons with disabilities to deal with the fact that the population of persons with disabilities in Korea has been growing and their degree of disabilities also getting severe.

A Study on Planning of Foreign Sailors' Temporary Living Facilities to Prevent the Spread of COVID-19 (COVID-19 확산 방지를 위한 외국인선원 임시생활시설 계획 연구)

  • Oh, Sang-baeg;Lee, Han-seok
    • Journal of Navigation and Port Research
    • /
    • v.45 no.4
    • /
    • pp.194-203
    • /
    • 2021
  • After the outbreak of COVID-19, local infections were spread by foreign sailors of foreign ships entering the ports. However, the government had difficulties in designating temporary living facilities around port areas due to the opposition from local residents. Therefore, the purpose of this study was to plan a floating temporary living facility for foreign sailors in the port area to prevent the spread of COVID-19 by foreign sailors. In this study, location selection, a facility volumetric plan, a unit facility plan, and a unit facility block plan are presented as results of facility planning. Floating temporary living facilities are expected to be used to prevent the spread of first-class infectious diseases in port areas in the future.

Comparison of microwave and steam-type drying processes for dehydrated sludge in a wastewater treatment plant (탈수슬러지의 마이크로웨이브와 증기 건조공정의 성능비교)

  • Sang-hong Jeong;Yun-seong Choi;Seung-Hwan Lee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.38 no.3
    • /
    • pp.155-164
    • /
    • 2024
  • There are two primary sludge drying methods such as the direct heating microwave method and the indirect heating steam one. In this study, the drying treatment facility at sewage treatment plant A applied both of these drying methods. The research aimed to investigate the optimal operation approach for the drying facility, considering the input sludge and the moisture content data after the drying process. Moisture content and removal rate data were executed at the research facility from January 2016 to December 2018. First, the microwave, a direct heating drying method, performed intensive drying only on the outer surface of the sludge by directly applying heat to the sludge using far infrared rays, so effective sludge drying was not achieved. On the other hand, the steam method of the indirect heating method used steam from a gas boiler to maximize the utilization of the heat transfer area and reduce energy of the dryer, resulting in an effective sludge drying efficiency. The sludge moisture content brought into the sludge drying facility was about 80%, but the moisture content of the sludge that went through the drying facility was less than 10% of the design standard. Therefore, the steam method of the indirect heating method is more effective than the microwave method of the previous direct heating method and is more effective for maintenance It has proven that it is an efficient method of operating construction facilities.

High-temperature ultrasonic thickness monitoring for pipe thinning in a flow-accelerated corrosion proof test facility

  • Cheong, Yong-Moo;Kim, Kyung-Mo;Kim, Dong-Jin
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1463-1471
    • /
    • 2017
  • In order to monitor the pipe thinning caused by flow-accelerated corrosion (FAC) that occurs in coolant piping systems, a shear horizontal ultrasonic pitch-catch waveguide technique was developed for accurate pipe wall thickness monitoring. A clamping device for dry coupling contact between the end of the waveguide and pipe surface was designed and fabricated. A computer program for multi-channel on-line monitoring of the pipe thickness at high temperature was also developed. Both a four-channel buffer rod pulse-echo type and a shear horizontal ultrasonic waveguide type for high-temperature thickness monitoring system were successfully installed to the test section of the FAC proof test facility. The overall measurement error can be estimated as ${\pm}10{\mu}m$ during a cycle from room temperature to $200^{\circ}C$.

Development of a Full-Scope Human Machine Simulator for Human Factors Experiments

  • Sim, R.S.;Oh, I.S.;Cheon, S.W.;Park, G.O.;Lee, H.C.;Cha, K.H.;Kim, D.K.;Son, S.W.;Sabri, M.;Paris, H.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.219-226
    • /
    • 1997
  • This paper presents the development of an Integrated Test Facility (ITF) that consists of a full-scope Human Machine Simulator (HMS) and some experimental measurement systems. This facility is aimed to experiment with tile design of the control room environment and the human interaction as it relates to the control of advanced nuclear power plants.

  • PDF

300kV DC Charging system for Synthetic Testing Facility (합성 차단 시험용 DC300kV 충전장치 개발)

  • Rim, G.H.;Choi, Y.W.;Park, J.M.;Park, K.Y.;Lee, W.Y.;Chung, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1354-1356
    • /
    • 2000
  • This paper deals with a 300kV dc charging system to be used ?s a voltage source in a circuit breaker synthetic short-circuit-test facility. Cockcroft-walton circuit is used to step up the rectified voltage from a single phase transformer of which primary winding is hooked up to an ac220 wall plug. Two systems with the same ratings have been designed and manufactured. The two system have been made of different supporting structure with different insulating materials. The paper describes a couple of charging schemes, system configurations and the synthetic test circuit in which the developed system is to be used.

  • PDF

LBLOCA AND DVI LINE BREAK TESTS WITH THE ATLAS INTEGRAL FACILITY

  • Baek, Won-Pil;Kim, Yeon-Sik;Choi, Ki-Yong
    • Nuclear Engineering and Technology
    • /
    • v.41 no.6
    • /
    • pp.775-784
    • /
    • 2009
  • This paper summarizes the tests performed in the ATLAS facility during its first two years of operation (2007${\sim}$2008). Two categories of tests have been performed successfully: (a) the reflood phase of the large-break loss-of-coolant accidents in a cold leg, and (b) the breaks in one of four direct vessel injection lines. Those tests contributed to understanding the unique thermal-hydraulic behavior, resolving the safety-related concerns and providing an evaluation of the safety analysis codes and methodology for the advanced pressurized water reactor, APR1400. Several important and interesting phenomena have been observed during the tests. In most cases, the ATLAS shows reasonable accident characteristics and conservative results compared with those predicted by one-dimensional safety analysis codes. A wide variety of small-break LOCA tests will be performed in 2009.