• Title/Summary/Keyword: Required thermal time

Search Result 312, Processing Time 0.025 seconds

Temperature Distribution Monitoring of Transformer Using IRR-Camera (적외선방사카메라를 이용한 변압기 온도분포 모니터링)

  • 이우선;정찬문;서용진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.459-462
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of Power transformer is measured with partial temperature distribution in real time.

  • PDF

Evaluation for Warming-up Performance and Fusing Quality through Heat Transfer Simulations of Laser Printer Fusing System (레이저 프린터 정착 시스템의 열전달 해석을 통한 승온 성능 및 정착성 예측)

  • Lee, Jin-sung
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2231-2235
    • /
    • 2008
  • Thermal performance of fusing system in laser printer is determined by FPOT(First print out time) required and toner fusing quality. FPOT is influenced by the thermal resistance of fusing system between heat source and nip region. Also FPOT is depended by the heat source power and toner fusing temperature. The fusing quality of toner is decided by the temperature, pressure and duration time in nip region. In this study, I have performed thermal analysis for the toner fusing system. Computational simulation has been used to understand the effect of heat source power and printing speed etc. on the temperature distribution of the fusing system. Also in order to predict fusing quality, numerical simulation of the process that paper is continuously supplied to the nip regions were performed. In comparison with the experimental results of the fusing quality vs transferred calory to the toner layer, I could evaluate various fusing condition parameters effected on the thermal performance.

  • PDF

Temperature Distribution Monitoring of Transformer (변압기 온도 변화특성 모니터링)

  • Lee, Woo-Sun;Jung, Chan-Moon;Son, Dong-Min;Seo, Young-Jin;Lim, Jang-Sub
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.69-72
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of power transformer is measured with partial temperature distribution in real time.

  • PDF

Control characteristics of a refrigerant compressor test facility (냉매압축기 성능시험장치의 제어 특성)

  • Lee, J. Y.;Lee, D. Y.;Kim, K. H.;Nam, P. W.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.46-51
    • /
    • 1999
  • This paper describes the control charcteristics of thermal/flow systems. In thermal/flow systems, the transport lag plays as a dead time causing a deterioration of the controllability. Besides this, such many parameters including the temperature, pressure, and flow rate affect the system response that a control scheme which can deal with multi-input is required. Particularly in a refrigerant compressor test facility, the evaporator and condenser interact each other so that the change in the evaporator pressure cause the condenser pressure to change or vice versa. Therefore, to control the evaporator pressure, not only the cooling water flow rate in the evaporator but also the coolant flow rate in the condenser is considered. Meanwhile, the conventional PID controllers, which is suitable for a single input system, shows a large overshoot for a disturbance input. In this work, the predictive control scheme is introduced and its applicability is discussed for thermal/flow systems.

  • PDF

Thermal Stress Calculations Using Enhanced Green's Function Considering Temperature-dependent Material Properties (온도 의존적 재료물성치를 고려한 개선된 그린함수 기반 열응력 계산)

  • Han, Tae-Song;Huh, Nam-Su;Jeon, Hyun-Ik;Ha, Seung-Woo;Cho, Sun-Young
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.5
    • /
    • pp.535-540
    • /
    • 2015
  • We propose an enhanced Green's function approach to predict thermal stresses by considering temperature-dependent material properties. We introduce three correction factors for the maximum stress, the time taken to reach maximum stress, and the time required to attain steady state based on the Green's function results for each temperature. The proposed approach considers temperature-dependent material properties using correction factors, which are defined as polynomial expressions with respect to temperatures based on Green's functions, that we obtain from finite-element (FE) analyses at each temperature. We verify the proposed approach by performing detailed FE analyses on thermal transients. The Green's functions predicted by the proposed approach are in good agreement with those obtained from FE analyses for all temperatures. Moreover, the thermal stresses predicted using the proposed approach are also in good agreement with the FE results, and the proposed approach provides better predictions than the conventional Green's function approach using constant, time-independent material properties.

Small Camera Module for TEC-less Uncooled Thermal Image (TEC-less 비냉각 열영상 검출기용 소형카메라 모듈 개발)

  • Kim, Jong-Ho
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.12 no.2
    • /
    • pp.97-103
    • /
    • 2017
  • Thermal imaging is mainly used in military equipment required for night observation. In particular, technologies of uncooled thermal imaging detectors are being developed as applied to low-cost night observation system. Many system integrators require different specifications of the uncooled thermal imaging camera but their development time is short. In this approach, EOSYSTEM has developed a small size, TEC-less uncooled thermal imaging camera module with $32{\times}32mm$ size and low power consumption. Both domestic detector and import detector are applied to the EOSYSTEM's thermal imaging camera module. The camera module contains efficient infrared image processing algorithms including : Temperature compensation non-uniformity correction, Bad/Dead pixel replacement, Column noise removal, Contrast/Edge enhancement algorithms providing stable and low residual non-uniformity infrared image.

Faultproof Design in Space for Monopropellant Rocket Engine Assembly (단일추진제 로켓 엔진 어셈블리를 위한 우주 공간에서의 과실 방지 설계)

  • Han, Cho-Young;Kim, Jeong-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1377-1384
    • /
    • 2003
  • An analysis has been performed for active thermal control of the KOMPSAT monopropellant rocket engine assembly, i.e., dual thruster module(DTM). The main efforts of this work have been directed at determining proper heater sizes for propellant valves and catalyst beds necessary to maintain their temperatures within specified temperature ranges under KOMPSAT environment and operational conditions. The TAS incorporated with TRASYS thermal radiation analyzer was used to establish a complete heat transfer model which allows to predict the DTM temperature as a function of time. The thermal analysis has been performed in transient mode to verify the appropriate power for catalyst bed heaters necessary to increase catalyst bed temperature to the required value within a specified period of time. Similar analysis has been executed to validate the heater power for the thermostatically controlled primary and redundant heater circuits used to prevent hydrazine freezing, i.e., single fault. Moreover the effect of the radiative property of thermal control coating of heat shield was examined. Thruster firing condition was also simulated for the heat soakback condition. As a consequence, all thermal analysis results for DTM satisfactorily met the thermal requirements for the KOMPSAT DTM under the worst case average voltage, i.e. 25 volt.

Optimizing of Diffusion Condition in Spin on Doping for c-Si Solar Cell (스핀 도핑을 이용한 단결정 실리콘 태양전지 확산 공정 최적화)

  • Yeo, In Hwan;Park, Ju Eok;Kim, Jun Hee;Cho, Hae Sung;Lim, Donggun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.5
    • /
    • pp.410-414
    • /
    • 2013
  • Rapid thermal processing (RTP) abruptly decreases the time required to perform solar cell processes. RTP were used to form emitter of crystalline silicon solar cells. The emitter sheet resistance is studied as a function of time and temperature. The objective of this study is reduction of doping process time with same performance. Emitter difRapid thermal dfusion was carried out by using a spin on doping and a RTP. iffusion was performed in the temperature range of $700{\sim}750^{\circ}C$ for 1m 30s~15 m. Thermal budgets yielded a $50{\Omega}/sq$ emitter using a P509 source. To reduce process time and get high efficiency, rapid thermal diffusion by IR lamp was employed in air atmosphere at $700^{\circ}C$ for 15 m.

Improving Anaerobic Digestion of Polyhydroxybutyrate by Thermal-Alkaline Pretreatment (열-알칼리성 전처리에 따른 폴리하이드록시부티레이트의 혐기성 소화 개선 효과 조사)

  • Trang, Le Thi Nhu;Lee, Joonyeob
    • Journal of Environmental Science International
    • /
    • v.31 no.7
    • /
    • pp.609-616
    • /
    • 2022
  • In this study, the effect of different reaction times for thermal-alkaline pretreatment on the solubilization and biogasification of polyhydroxybutyrate (PHB) were evaluated. Thermal-alkaline pretreatment tests were performed at 73 ℃ and pH 13 at 0-120 h reaction times. The mesophilic anaerobic batch tests were performed with untreated and pretreated PHB samples. The increase in the pretreatment reaction time results in a 52.8-98.8% increase of the abiotic solubilization efficiency of the PHB samples. The reaction time required to achieve solubilization efficiencies of 50%, 90%, and 95% were 10.5, 52.0, and 89.6 h, respectively. The biogasification of the untreated PHB samples achieved a specific methane production rate of 3.6 mL CH4/g VSS/d and require 101.3 d for complete biogasification. The thermal-alkaline pretreatment significantly improved specific methane production rate (10.2-16.0 time increase), lag time (shortened by 76-81%), and time for complete biogasification (shortened by 21-83%) for the biogasification of the PHB samples when compared to those of the untreated PHB samples. The improvement was higher as the reaction time of the thermal-alkaline pretreatment increased. The findings of this study could be used as a valuable reference for the optimization of the biogasification process in the treatment of PHB wastes.

Analysis of Heat Flow and Thermal Stress for Divertors (디버터의 열유동 및 열응력 해석 1)

  • Lee, Sang-Yun;Kim, Hong-Bae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.1 s.94
    • /
    • pp.238-245
    • /
    • 1999
  • For the optimal design of plasma facing components of a fusion reactor, thorough understanding of thermal behavior of high heat. nux components are required. The purpose of this research is to investigate the characteristics of heat flow and thermal stress in divertors which are exposed to high heat load varing with time and space-Numerical simulations of heat now and thermal stress for three types of diverter are performed using finite volume method and finite element method. Respectly, commercial FLUENT code are used in the heat flow simulation, and maximum surface temperature, temperature distribution and cooling rate are calculated. Commercial ABQUS code are used for calculating temperature distribution. thermal stress, strain and displacement. Through this computer simulation. design data for cooling system and Structural provided.

  • PDF