Digital Tomosynthesis versus Conventional Radiography for Evaluating Osteonecrosis of the Femoral Head

  • Yun Hwa Roh;Seunghun Lee;Jeong Ah Ryu;Yeo Ju Kim;Yeesuk Kim;Jiyoon Bae
    • Korean Journal of Radiology
    • /
    • v.22 no.12
    • /
    • pp.2026-2033
    • /
    • 2021
  • Objective: The aim of this study was to compare the diagnostic performances of digital tomosynthesis (DTS) and conventional radiography in detecting osteonecrosis of the femoral head (ONFH) using computed tomography (CT), as the reference standard and evaluate the diagnostic reproducibility of DTS. Materials and Methods: Forty-five patients (24 male and 21 female; age range, 25-77 years) with clinically suspected ONFH underwent anteroposterior radiography, DTS, and CT. Two musculoskeletal radiologists independently evaluated the presence and type of ONFH. The diagnostic performance of radiography and DTS in detecting the presence of ONFH and determining the types of ONFH were evaluated. The interobserver and intraobserver reliabilities of each imaging modality were analyzed using Cohen's kappa. Results: DTS had higher sensitivity (89.4%-100% vs. 74.5%-76.6%) and specificity (97.3%-100% vs. 78.4%-83.8%) for ONFH detection than radiography. DTS showed higher performance than radiography in identifying the subtypes of ONFH with statistical significance in one reader (type 1, 100% vs. 30.8%, p = 0.004; type II, 97.1% vs. 73.5%, p = 0.008). The interobserver agreement was excellent for DTS and moderate for radiography (kappa of 0.86 vs. 0.57, respectively). The intraobserver agreement for DTS was higher than that of radiography (kappa of 0.96 vs. 0.69, respectively). Conclusion: DTS showed higher diagnostic performance and reproducibility than radiography in detecting ONFH. DTS may be used as a first-line diagnostic modality instead of radiography for patients suspected of having ONFH.

Performance Measurement of Diagnostic X Ray System (진단용 X선 발생장치의 성능 측정)

  • You, Ingyu;Lim, Cheonghwan;Lee, Sangho;Lee, Mankoo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.447-454
    • /
    • 2012
  • To examine the performance of a diagnostic X-ray system, we tested a linearity, reproducibility, and Half Value Layer(HVL). The linearity was examined 4 times of irradiation with a given condition, and we recorded a level of radiation. We then calculated the mR/mAs. And the measured value should not be more than 0.1. If the measured value was more than 0.1, we could know that the linearity was decreased. The reproducibility was analyzed 10 times of irradiations at 80kVp, 200mA, 20mAs and 120kVp, 300mA, 8mAs. The values from these analyses were integrated into CV equation, and we could get outputs. The reproducibility was good if the output was lower than 0.05. HVL was measured 3 times of irradiation without a filter, and we inserted additional HLV filters with 0, 1, 2, 4 mm of thickness. We tested the values until we get the measured value less than a half of the value measured without additional filter. We tested the linearity, the reproducibility, and HVL of 5 diagnostic X-ray generators in this facilities. The linearity of No. 1 and No. 5 generator didn't satisfy the standard for radiation safety around 300mA~400mA and 100mA~200mA, respectively. HVL of No.1 generator was not satisfied at 80kVp. The outputs were higher in the three-phase equipment than the single-phase equipment. The old generators need to maintain and exchange of components based on the these results. Then, we could contribute to getting more exact diagnosis increasing a quality of the image and decreasing an expose dose of radiation.

Reproducibility Assessment of Skin Furrows Measurement using Facial Skin Photographing System (전안촬영시스템을 이용한 주름 측정의 재현성 평가)

  • Lee, Seung-Ryun;Lee, Yun-Kyu;Park, Seo-Young;Ko, Kyoung-Mo;Lee, Yoon-Kyoung;Kim, Jae-Su;Lee, Bong-Hyo;Lim, Seong-Chul;Jung, Tae-Young;Lee, Kyung-Min
    • Journal of Acupuncture Research
    • /
    • v.25 no.1
    • /
    • pp.187-197
    • /
    • 2008
  • Objectives : The purpose of this study was to assess the reproducibility of measurement of facial skin furrows using a facial skin photographing system. Methods : Subjects were 19 patients who visited the department of acupuncture and moxsibustion, at the hospital of Oriental medical college, at Daegu Haany University for the cosmetic acupuncture treatment during August 2007 to 31th August 2007. The facial skin photograph of each participant was analyzed a total of six times in two days using DM-3(a facial skin photographing system). The square and counts of skin furrows were also measured for each one. As the statistical method, Pearson's correlation coefficient and repeated measured ANOVA were used. Results : The Pearson's correlation coefficient, it showed significantly high correlation in both the square and count of skin furrows for each analysis time. Repeated measured ANOVA showed no significant differences among analyses in both square and count of skin furrows. Conclusions : This study reveales that the measurement of the count and square of facial skin furrows by facial skin photograph analysis has high reproducibility. DM-3(a facial skin photographing system) can be useful for the evaluation of facial skin furrows in facial cosmetic acupuncture.

  • PDF

Right Ventricular Mass Quantification Using Cardiac CT and a Semiautomatic Three-Dimensional Hybrid Segmentation Approach: A Pilot Study

  • Hyun Woo Goo
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.901-911
    • /
    • 2021
  • Objective: To evaluate the technical applicability of a semiautomatic three-dimensional (3D) hybrid CT segmentation method for the quantification of right ventricular mass in patients with cardiovascular disease. Materials and Methods: Cardiac CT (270 cardiac phases) was used to quantify right ventricular mass using a semiautomatic 3D hybrid segmentation method in 195 patients with cardiovascular disease. Data from 270 cardiac phases were divided into subgroups based on the extent of the segmentation error (no error; ≤ 10% error; > 10% error [technical failure]), defined as discontinuous areas in the right ventricular myocardium. The reproducibility of the right ventricular mass quantification was assessed. In patients with no error or < 10% error, the right ventricular mass was compared and correlated between paired end-systolic and end-diastolic data. The error rate and right ventricular mass were compared based on right ventricular hypertrophy groups. Results: The quantification of right ventricular mass was technically applicable in 96.3% (260/270) of CT data, with no error in 54.4% (147/270) and ≤ 10% error in 41.9% (113/270) of cases. Technical failure was observed in 3.7% (10/270) of cases. The reproducibility of the quantification was high (intraclass correlation coefficient = 0.999, p < 0.001). The indexed mass was significantly greater at end-systole than at end-diastole (45.9 ± 22.1 g/m2 vs. 39.7 ± 20.2 g/m2, p < 0.001), and paired values were highly correlated (r = 0.96, p < 0.001). Fewer errors were observed in severe right ventricular hypertrophy and at the end-systolic phase. The indexed right ventricular mass was significantly higher in severe right ventricular hypertrophy (p < 0.02), except in the comparison of the end-diastolic data between no hypertrophy and mild hypertrophy groups (p > 0.1). Conclusion: CT quantification of right ventricular mass using a semiautomatic 3D hybrid segmentation is technically applicable with high reproducibility in most patients with cardiovascular disease.

An experimental study on the reproducibility and the position of centric relation and Myocentric (중심위와 Myocentric의 재현성 및 상호위치에 관한 연구)

  • Lee, Jong-Yeab;Kim, Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.24 no.1
    • /
    • pp.45-54
    • /
    • 1986
  • The establishment and/or registration of an optimal or physiologic relationship between the maxillae and mandible has long been a subject of considerable interest and controversy in dentistry. Centric relation has been generally accepted as a repeatable starting point for restoring the mouth. Recently, it has been claimed that an electronic device (Myo-Monitor) will produce an accurate, reproducible occlusal registration at the vertical and horizontal occlusal position most compatible with the muscular of each patient. The objectives of this study was to compare Myo-Monitor centric to centric relation at the points of reproducibility and anteroposterior, superoinferior position. A Vericheck instrument was employed for examining difference in the position and reproducibility of mandible reproduced by the various check bite records. For this study, 8 dental students and dentists who had no missing teeth and no difficulties of mandibular movement were selected. The following three different positions of the mandible were registered (a) centric relation manipulated by means of chin-point technique with Lucia-jig, (b) centric relation manipulated by means of bilateral technique, (c) Myocentric manipulated by Myo-Monitor. From this experiment, the following results were obtained. 1. Bilateral manipulated centric relation was more reproducible than Myocentric in anteroposterior and superoinferior position , but more reproducible than centric relation manipulated by means of chin point technique with Lucia-jig in anteroposoterior position. Centric relation manipulated by means of chin Point technique with Lucia-jig was more reproducible than Myocentric in right anteroposterior and superoinferior position. 2. Centric relation by means of chin point technique with Lucia-jig was posterior($2.16{\pm}0.78mm$) and superior($0.41{\pm}0.16mm$) to centric occlusion. Bilateral manipulated centric relation was posterior($1.68{\pm}0.10mm$) and superior($1.02{\pm}0.45mm$) to centric occlusion. Myocentric was anterior($0.75{\pm}0.70mm$), inferior($0.59{\pm}0.44mm$) to centric occlusion.

  • PDF

Evaluation of accuracy of 3-dimensional printed dental models in reproducing intermaxillary relational measurements: Based on inter-operator differences

  • Choi, Won-joon;Lee, Su-jung;Moon, Cheol-Hyun
    • The korean journal of orthodontics
    • /
    • v.52 no.1
    • /
    • pp.20-28
    • /
    • 2022
  • Objective: Although, digital models have recently been used in orthodontic clinics, physical models are still needed for a multitude of reasons. The purpose of this study was to assess whether the printed models can replace the plaster models by evaluating their accuracy in reproducing intermaxillary relationships and by appraising the clinicians' ability to measure the printed models. Methods: Twenty sets of patients' plaster models with well-established occlusal relationships were selected. Models were scanned using an intraoral scanner (Trios 3, 3Shape Dental System) by a single operator. Printed models were made with ZMD-1000B light-curing resin using the stereolithography method 3-dimensional printer. Validity, reliability, and reproducibility were evaluated using measurements obtained by three operators. Results: In evaluation of validity, all items showed no significant differences between measurements taken from plaster and printed models. In evaluation for reliability, significant differences were found in the distance between the gingival zeniths of #23-#33 (DZL_3) for the plaster models and at #17-#43 (DZCM_1) for the printed models. In evaluation for reproducibility, the plaster models showed significant differences between operators at midline, and printed models showed significant differences at 7 measurements including #17-#47 (DZR_7). Conclusions: The validity and reliability of intermaxillary relationships as determined by the printed model were clinically acceptable, but the evaluation of reproducibility revealed significant inter-operator differences. To use printed models as substitutes for plaster models, additional studies on their accuracies in measuring intermaxillary relationship are required.

Reproducibility of physiological patterns in disgust visual stimulation design

  • Lee, Kyung-Hwa;E. Sokhadze;Jang, Eun-Hye;Yang, Gyung-Hye;Sohn, Jin-Hun
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.11a
    • /
    • pp.73-80
    • /
    • 2000
  • The paper is addressed to the topic of physiological response-specificity in disgust induced by visual stimulation. The purpose of this study was to evaluate reproducibility of physiological reactivity pattern during disgust elicited by the International Affective Pictures System (IAPS) in 2 experiments. Twenty-nine subjects participated in the first experiment with 3 visual stimulation sessions with disgust-eliciting slides (3 slides in each 1 min long session). In the second experiment disgust-eliciting slides from the IAPS were presented to 42 subjects in 2 sessions (one slide for 1 min). Spectral power of frontal EEG, skin conductance (SCL, SCR and NS.SCR), heart rate(HR), heart period variability(HPV) and respiration rate were recorded. Visual stimulation evoked 1:.n deceleration, higher power of high frequency component of HPV, increased SCL and NS.SCR frequency, frontal slow alpha blocking and moderate increase in fast beta power in most of the sessions in both experiments. However in the second experiment the EEG pattern associated with disgust showed inconsistent shifts in fast alpha and slow beta bands, but was marked by higher power of theta activity. Our data in both experiments emphasizes presence of disgust-specific profiles of autonomic and at the less extent EEG responses in visual stimulation context. Discussed are potential behavioral mechanisms leading to observed physiological manifestations in disgust elicited by visual stimulation. The results support the consideration that disgust is an withdrawal type negative valence emotion associated with relatively low autonomic arousal (low HR, low amplitude SCRs with relatively high NS.SCR frequency) and moderate EEG activation signs. Obtained data showed more consistent reproducibility of disgust-specific autonomic rather than EEG response patterns during visual stimulation design.

  • PDF

Volumetric CT Texture Analysis of Intrahepatic Mass-Forming Cholangiocarcinoma for the Prediction of Postoperative Outcomes: Fully Automatic Tumor Segmentation Versus Semi-Automatic Segmentation

  • Sungeun Park;Jeong Min Lee;Junghoan Park;Jihyuk Lee;Jae Seok Bae;Jae Hyun Kim;Ijin Joo
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1797-1808
    • /
    • 2021
  • Objective: To determine whether volumetric CT texture analysis (CTTA) using fully automatic tumor segmentation can help predict recurrence-free survival (RFS) in patients with intrahepatic mass-forming cholangiocarcinomas (IMCCs) after surgical resection. Materials and Methods: This retrospective study analyzed the preoperative CT scans of 89 patients with IMCCs (64 male; 25 female; mean age, 62.1 years; range, 38-78 years) who underwent surgical resection between January 2005 and December 2016. Volumetric CTTA of IMCCs was performed in late arterial phase images using both fully automatic and semi-automatic liver tumor segmentation techniques. The time spent on segmentation and texture analysis was compared, and the first-order and second-order texture parameters and shape features were extracted. The reliability of CTTA parameters between the techniques was evaluated using intraclass correlation coefficients (ICCs). Intra- and interobserver reproducibility of volumetric CTTAs were also obtained using ICCs. Cox proportional hazard regression were used to predict RFS using CTTA parameters and clinicopathological parameters. Results: The time spent on fully automatic tumor segmentation and CTTA was significantly shorter than that for semi-automatic segmentation: mean ± standard deviation of 1 minutes 37 seconds ± 50 seconds vs. 10 minutes 48 seconds ± 13 minutes 44 seconds (p < 0.001). ICCs of the texture features between the two techniques ranged from 0.215 to 0.980. ICCs for the intraobserver and interobserver reproducibility using fully automatic segmentation were 0.601-0.997 and 0.177-0.984, respectively. Multivariable analysis identified lower first-order mean (hazard ratio [HR], 0.982; p = 0.010), larger pathologic tumor size (HR, 1.171; p < 0.001), and positive lymph node involvement (HR, 2.193; p = 0.014) as significant parameters for shorter RFS using fully automatic segmentation. Conclusion: Volumetric CTTA parameters obtained using fully automatic segmentation could be utilized as prognostic markers in patients with IMCC, with comparable reproducibility in significantly less time compared with semi-automatic segmentation.

Results of a Round-Robin Test for the Draft International Standard on FT-IR Gas Analysis of Fire Effluents from a Cone Calorimeter (콘칼로리미터 연소가스 FT-IR 분석을 위한 국제표준 초안의 비교시험 결과분석)

  • Choi, Jung-Min;Park, Kye-Won;Jeong, Jae-Gun
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.1-8
    • /
    • 2019
  • The international standard for FT-IR gas analysis of fire effluents in ISO 5660-1 cone calorimeter has been being developed in ISO TC 92. A comparison of the round-robin test of WD 21397 was conducted with six participating laboratories in 2018. The test specimens were PMMA, rigid PU foam board, and PVC flooring. The measurement quantities were the time-to-ignition, peak heat release rate, total heat release, and effective heat of combustion for a cone calorimeter test and peak gas concentration, gas generation, and gas yield for FT-IR gas analysis. No outliers were identified. For the cone calorimeter quantities, the repeatability and reproducibility were 1.5% and 9.8%, respectively. For FT-IR gas analysis, the repeatability and reproducibility was 12.9% and 27.9%, respectively.

Study on the Sun Screen Test Method using Elipsometer (분광타원해석기를 이용한 자외선 차단제의 평가방법 연구)

  • Kim, Joon-Woo;Lee, Jong-Soo;Lee, Ji-Hye;Choung, Suk-Jin
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.37 no.2
    • /
    • pp.137-141
    • /
    • 2011
  • Sunscreen is divided into the organic agent of UV absorption and inorganic agent of reflection. These are evaluated by sun protection factor (SPF) in-vivo test requiring high cost and time, while in-vitro tests are adopted commonly because of short test time, easy result collection. Generally, test method of SPF use SPF 290a by UV-vis spectrometer. The evaluate by SPF 290 has low reproducibility. Although analysis using UV-vis spectrometer has high reproducibility, it is hard to separated results of transmission, adsorption, and reflection. In this study, suggested method of elipsometer has some merit such as high reproducibility, easy separation of transmission/adsorption/re- flection, analysis using various incident angle. We tested the validity of elipsometer for SPF measurement, using commercially available sun-block (SPF 50).