• Title/Summary/Keyword: Reproducibility of result

Search Result 309, Processing Time 0.031 seconds

Evaluation of the effect of abutment preparation angles on the repeatability and reproducibility using a blue light model scanner

  • Kim, Dong-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.4
    • /
    • pp.210-217
    • /
    • 2020
  • PURPOSE. The purpose of the study is to evaluate the repeatability and reproducibility of the abutment angle using a blue light scanner. MATERIALS AND METHODS. 0°, 6°, and 10° wax cast abutment dies were fabricated. Each of the silicone impression was produced using the replicable silicone. Each study die was constructed from the prepared replicable stone used for scans. 3-dimensional data was obtained after scanning the prepared study dies for the repeatability by using the blue light scanner. The prepared 3-dimensional data could have the best fit alignment using 3-dimensional software. For reproducibility, each abutment was used as the first reference study die, and then it was scanned five times per each. 3-dimensional software was used to perform the best fit alignment. The data obtained were analyzed using a nonparametric Kruskal-Wallis H test (α=.05), post hoc Mann-Whitney U test, and Bonferroni correction (α=.017). RESULTS. The repeatability of 0°, 6°, and 10° abutments was 3.9, 4.4 and 4.7 ㎛, respectively. Among them, the 0° abutment had the best value while the 10° abutment showed the worst value. There was a statistically significant difference (P<.05). The reproducibility of 0°, 6°, and 10° abutments was 6.1, 5.5, and 5.3 ㎛, respectively. While the 10° abutment showed the best value, the 0° abutment showed the worst value. However, there was no statistically significant difference (P>.05). CONCLUSION. In repeatability, the 0° abutment showed a positive result. In reproducibility, the 10° abutment achieved a positive result.

Evaluating intra- and inter-examiner reproducibility in histometric measurement: one-wall intrabony periodontal defects in beagle dogs

  • Kim, Soo-Kyung;Choi, Eun-Hee;Lee, Jung-Seok;Kim, Tae-Gyun;Choi, Seong-Ho;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.4
    • /
    • pp.172-179
    • /
    • 2010
  • Purpose: Accurate and exact measurement is an important factor for generating meaningful results in any properly designed study. If all the participating examiners are able to yield similar results, it will be possible to evaluate the objective results of the study more easily and quickly. The purpose of this study was to evaluate the intra- and inter-examiner reproducibility of histometric measurements in the intrabony periodontal defect model. Methods: One wall intrabony defects were surgically created at the distal aspect of the second and the medial aspect of the fourth mandibular premolars in the right and left jaw quadrants in twenty beagle dogs and the defect sites received the following ${\beta}$-tri calcium phosphate, growth differentiation factor-0, growth differentiation factor-100 and sham surgery. Histometric analysis was performed after 8 weeks. Histometric parameters were recorded and repeated at three months interval by three examiners. Intra- and inter-examiner reproducibility was assessed. Results: Most parameters of all the groups showed high intra- and inter-examiner reproducibility. Parameters including defect height, bone regeneration height, cementum regeneration height, and formation of junctional epithelium yielded interexaminer correlation ${\geq}0.9$. The intra-examiner reproducibility showed a high result, over 0.9. Conclusions: Histometric evaluation of the one-wall intra-alveolar periodontal defect model showed high reproducibility not only for a single given examiner but also among the three examiners.

Mini-Review of Studies Reporting the Repeatability and Reproducibility of Diffusion Tensor Imaging

  • Seo, Jeong Pyo;Kwon, Young Hyeon;Jang, Sung Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.1
    • /
    • pp.26-33
    • /
    • 2019
  • Purpose: Diffusion tensor imaging (DTI) data must be analyzed by an analyzer after data processing. Hence, the analyzed data of DTI might depend on the analyzer, making it a major limitation. This paper reviewed previous DTI studies reporting the repeatability and reproducibility of data from the corticospinal tract (CST), one of the most actively researched neural tracts on this topic. Materials and Methods: Relevant studies published between January 1990 and December 2018 were identified by searching PubMed, Google Scholar, and MEDLINE electronic databases using the following keywords: DTI, diffusion tensor tractography, reliability, repeatability, reproducibility, and CST. As a result, 15 studies were selected. Results: Measurements of the CSTs using region of interest methods on 2-dimensional DTI images generally showed excellent repeatability and reproducibility of more than 0.8 but high variability (0.29 to 1.00) between studies. In contrast, measurements of the CST using the 3-dimensional DTT method not only revealed excellent repeatability and reproducibility of more than 0.9 but also low variability (repeatability, 0.88 to 1.00; reproducibility, 0.82 to 0.99) between studies. Conclusion: Both 2-dimensional DTI and 3-dimensional DTT methods appeared to be reliable for measuring the CST but the 3-dimensional DTT method appeared to be more reliable.

An Experimental Study on the Exothermic Properties of Cement Mortar Containing Conductive Materials (전도성 재료를 혼입한 모르타르의 발열특성에 관한 실험적 연구)

  • Song, Dong-Geun;Hong, Chul-Ho;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.131-132
    • /
    • 2014
  • In this study, an experiment was carried out using graphite, conductive nickel powder, copper bar, carbon fiber for evaluate the exothermic properties and heating reproducibility of the cement mortar containing conductive material. As a result, the conductive materials that interfere with heating reproducibility are present, and the optimal conductive materials exist in each input voltage.

  • PDF

A Study on the Allowable Deviation for the Measured Level of the Impact Sound Insulation Performance (바닥충격음 차음성능평가에 있어서 측정 레벨의 허용오차에 관한 연구)

  • 장길수;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.222-226
    • /
    • 1997
  • The reproducibility of measured level is a prior condition for the reliable assessment of the sound insulation performance. To review the reproducibility of impact sound level, 20 floors were selected in highrise apartment house, and then impact sound levels of two kinds of typical floors were measured with 10 times in each receiving point. The impact sound insulation class values were derived with a standard tapping machine and bang machine. Inspection of the result showed that smaller scale of the room caused to lower the reproducibility and that the higher values of standard deviation in lower frequency caused to deteriorate the reliability of assesment. Thus to enhance the reproducibility of the impact sound insulation class, greater allowable deviation of measured level is required in lower frequency than in higher one.

  • PDF

A Comparison on the Reproducibility of Parametric Bodies Used in the Virtual Garment System

  • Choi, Hee Eun;Nam, Yun Ja;Kim, Hye Suk
    • Fashion & Textile Research Journal
    • /
    • v.16 no.2
    • /
    • pp.266-274
    • /
    • 2014
  • Parametric bodies reproduce the actual shape of human body parts and should be convenient for general users to change size to judge the visual fit of clothes on-line. In this study, three parametric bodies(i.e. I, C, D ) were compared to verify the accuracy of the provided body dimensions and reproducibility to a target model. To compare reproducibility, the 20s female standard virtual model developed for an apparel industry by Korean agency for technology and standards is used. The investigation of existing parameters showed that the numbers and kinds of parameters provided by each program were different with some errors in notation; in addition, some of virtual body dimensions went beyond the maximum allowable error. The result of changing each parametric body to the 20s female standard body showed that D, C, I in order produced better reproducibility for body dimensions. There were different levels of protrusion and concavity in the virtual cross sections and virtual longitudinal sections despite the small differences in body dimensions and cross sectional areas; in addition, some parametric body was not bilateral symmetry. The results of this study can be used as basic information in the standardization of a virtual model used in a virtual garment program.

An Evaluation of the Mandibular Movements Reproducibility by using Both Pantographic Reproducibility Index and BioEGN Reproducibility Index (하악운동 재현성의 평가에 관한 비교연구)

  • Kyung-Soo Han;Ho-In Jung
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.2
    • /
    • pp.383-392
    • /
    • 1996
  • An observation and evaluation of the reproducibility of the mandibular movements has been a integral part of a test for mandibular function and dysfunction. After Pantographic Reproducibility Index(PRI) was introduced in dentistry, many authors have used the index for investigation of mandibular movement function, especially in condylar compartment. Howerer, the difficult and time-consuming work of instrumentation for getting the PRI has been a major obstacle in using pantograph. This study was performed to try a new mandibular reproducibility index, so-called BioEGN reproducibility index(BERI), calculated from mandibular trajectory recorded with BioEGN. 26 dental students without any signs and symptoms of temporomandibular disorders and 22 patients with temporomandibular disorders took part in this study and classed to control group and patients group, respectively. Pantronic and BioEGN were used to record and calculate the indices, PRI and BERI. PRI had only one value, but BERI had two values of outgoing and incoming movement in each scale. With two scales of small and large, as a result, BERI had four values in this study. PRI corresponded to BERI in small scale on outgoing total movements. The data were calculated and analyzed with SAS/stat program and the conclusion of this study were as follows : 1. In every scales, in each movement, BERI on outgoing movement in control group was lower than that in patients group, respectively, but BERI on incoming movement was only different in one side movement, that was, left excursion. 2. The difference between BERI on outgoing movement and BERI on incoming movement was only shown in small scale on total movements, not in each movement, in control group. However, there was generally a positive correlationship between BERI on outgoing movement and BERI on incoming movement in each movement in both groups. 3. Simple statistics of PRI was similar to that of BERI on total movements in small scale, but there was a negative correlation between PRI and BERI on total movements in large sclae only in patients group.

  • PDF

Evaluation of the Exothermic Properties and Reproducibility of Concrete Containing Electro-conductive Materials (전기전도성 재료를 혼입한 콘크리트의 발열특성 및 재현성 평가)

  • Song, Dong-Geun;Cho, Hyeong-Kyu;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.1
    • /
    • pp.25-34
    • /
    • 2016
  • From 1990's, a study on the development of exothermic concrete, a concrete which electro-conductive material is mixed, has been proceeded. However, due to the difficulty of exothermic reproducibility of concrete specimen, the study has been unable to continuously carried out. Accordingly, this study was focused on developing an exothermic concrete for the purpose of snow-melting material. Cement paste and mortar specimens mixed with graphite, conductive metal powder and chemical admixture were made. The evaluation of exothermic performance and reproducibility was conducted under $-2^{\circ}C$ of low temperature. In addition, micro-chemical analysis was carried out to investigate a cause of exothermic reproducibility. As a test result, the specimen mixed with graphite and superplasticizer with air entrained showed the best exothermic performance and reproducibility. Through micro-chemical analysis, it is judged that polymer or methacrylic acid (MAA), the contents inside the superplasticizer with air entrained, gave exothermic reproducibility by generating the electrochemical reaction with graphite.

The Aesthetics of Death of Works of Comtemporary Art (현대 예술 작품에 나타난 죽음의 미학)

  • Wang, Xin-yu;Kim, Hyun-joo;Youn, Ji-young
    • Journal of Digital Convergence
    • /
    • v.18 no.4
    • /
    • pp.439-451
    • /
    • 2020
  • In order to deeply understand the significance of death aesthetics in contemporary art, this research first summarizes the development process of death aesthetics in art works with popular perspectives, and then classifies and discusses death aesthetics in modern art works. The results of this study are as follows: First, the aesthetic expressions of death are divided into two types: death reproducibility and death symbolism. Death reproducibility includes reproducibility of real objects and reproducibility of imaginary objects. The symbolism of death can be divided into external and internal manifestations. Secondly, in contemporary art, the reproducibility of death through the description of death scenes has increased the various problems and philosophical significance caused by death. Third, in contemporary art, the symbolism meaning of death is not just something directly related to death, it also shows the various psychological states brought about by death. Subsequent research will promote the artists' visual expression of the aesthetics of death in artworks, and the profound changes in meaning that result from it.

The Effect of Sample Handling on the Rheological Measurement of Regenerated Silk Fibroin Formic Acid Solution using Parallel Plate Geometry

  • Cho, Hee-Jung;Um, In-Chul
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.22 no.1
    • /
    • pp.5-10
    • /
    • 2011
  • The effect of sample handling condition on the rheological measurement of regenerated silk fibroin formic acid solution using parallel plate geometry was investigated. In case of loading method, the loading by pouring sample solution resulted in the best reproducibility of rheological measurement. Loading with spoon showed a high variance of viscosity value at low shear rate region ($0.01{\sim}1sec^{-1}$) while loading with syringe exhibited a low reproducibility of viscosity at high shear region ($1{\sim}100sec^{-1}$) with a disappearance of shear thinning phenomenon. It was revealed that the sample loading with small extra amount lead to the most reproducible result. The sample loading with the exact amount for the measuring plate resulted in a lack of reproducibility of high shear viscosity, while the loading with large extra volume produced a limited consistency of low shear viscosity. It was turned out that 3 min. of waiting time before measurement was the optimum condition for reliable result. When the waiting time was less than 1 min., the low shear viscosity was obtained with a lack of consistency. On the other hand, the sample solution started drying when the waiting time increased up to 5 min.