• 제목/요약/키워드: Reproducibility of result

검색결과 309건 처리시간 0.031초

Evaluation of the effect of abutment preparation angles on the repeatability and reproducibility using a blue light model scanner

  • Kim, Dong-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권4호
    • /
    • pp.210-217
    • /
    • 2020
  • PURPOSE. The purpose of the study is to evaluate the repeatability and reproducibility of the abutment angle using a blue light scanner. MATERIALS AND METHODS. 0°, 6°, and 10° wax cast abutment dies were fabricated. Each of the silicone impression was produced using the replicable silicone. Each study die was constructed from the prepared replicable stone used for scans. 3-dimensional data was obtained after scanning the prepared study dies for the repeatability by using the blue light scanner. The prepared 3-dimensional data could have the best fit alignment using 3-dimensional software. For reproducibility, each abutment was used as the first reference study die, and then it was scanned five times per each. 3-dimensional software was used to perform the best fit alignment. The data obtained were analyzed using a nonparametric Kruskal-Wallis H test (α=.05), post hoc Mann-Whitney U test, and Bonferroni correction (α=.017). RESULTS. The repeatability of 0°, 6°, and 10° abutments was 3.9, 4.4 and 4.7 ㎛, respectively. Among them, the 0° abutment had the best value while the 10° abutment showed the worst value. There was a statistically significant difference (P<.05). The reproducibility of 0°, 6°, and 10° abutments was 6.1, 5.5, and 5.3 ㎛, respectively. While the 10° abutment showed the best value, the 0° abutment showed the worst value. However, there was no statistically significant difference (P>.05). CONCLUSION. In repeatability, the 0° abutment showed a positive result. In reproducibility, the 10° abutment achieved a positive result.

Evaluating intra- and inter-examiner reproducibility in histometric measurement: one-wall intrabony periodontal defects in beagle dogs

  • Kim, Soo-Kyung;Choi, Eun-Hee;Lee, Jung-Seok;Kim, Tae-Gyun;Choi, Seong-Ho;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • 제40권4호
    • /
    • pp.172-179
    • /
    • 2010
  • Purpose: Accurate and exact measurement is an important factor for generating meaningful results in any properly designed study. If all the participating examiners are able to yield similar results, it will be possible to evaluate the objective results of the study more easily and quickly. The purpose of this study was to evaluate the intra- and inter-examiner reproducibility of histometric measurements in the intrabony periodontal defect model. Methods: One wall intrabony defects were surgically created at the distal aspect of the second and the medial aspect of the fourth mandibular premolars in the right and left jaw quadrants in twenty beagle dogs and the defect sites received the following ${\beta}$-tri calcium phosphate, growth differentiation factor-0, growth differentiation factor-100 and sham surgery. Histometric analysis was performed after 8 weeks. Histometric parameters were recorded and repeated at three months interval by three examiners. Intra- and inter-examiner reproducibility was assessed. Results: Most parameters of all the groups showed high intra- and inter-examiner reproducibility. Parameters including defect height, bone regeneration height, cementum regeneration height, and formation of junctional epithelium yielded interexaminer correlation ${\geq}0.9$. The intra-examiner reproducibility showed a high result, over 0.9. Conclusions: Histometric evaluation of the one-wall intra-alveolar periodontal defect model showed high reproducibility not only for a single given examiner but also among the three examiners.

Mini-Review of Studies Reporting the Repeatability and Reproducibility of Diffusion Tensor Imaging

  • Seo, Jeong Pyo;Kwon, Young Hyeon;Jang, Sung Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권1호
    • /
    • pp.26-33
    • /
    • 2019
  • Purpose: Diffusion tensor imaging (DTI) data must be analyzed by an analyzer after data processing. Hence, the analyzed data of DTI might depend on the analyzer, making it a major limitation. This paper reviewed previous DTI studies reporting the repeatability and reproducibility of data from the corticospinal tract (CST), one of the most actively researched neural tracts on this topic. Materials and Methods: Relevant studies published between January 1990 and December 2018 were identified by searching PubMed, Google Scholar, and MEDLINE electronic databases using the following keywords: DTI, diffusion tensor tractography, reliability, repeatability, reproducibility, and CST. As a result, 15 studies were selected. Results: Measurements of the CSTs using region of interest methods on 2-dimensional DTI images generally showed excellent repeatability and reproducibility of more than 0.8 but high variability (0.29 to 1.00) between studies. In contrast, measurements of the CST using the 3-dimensional DTT method not only revealed excellent repeatability and reproducibility of more than 0.9 but also low variability (repeatability, 0.88 to 1.00; reproducibility, 0.82 to 0.99) between studies. Conclusion: Both 2-dimensional DTI and 3-dimensional DTT methods appeared to be reliable for measuring the CST but the 3-dimensional DTT method appeared to be more reliable.

전도성 재료를 혼입한 모르타르의 발열특성에 관한 실험적 연구 (An Experimental Study on the Exothermic Properties of Cement Mortar Containing Conductive Materials)

  • 송동근;홍철호;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.131-132
    • /
    • 2014
  • In this study, an experiment was carried out using graphite, conductive nickel powder, copper bar, carbon fiber for evaluate the exothermic properties and heating reproducibility of the cement mortar containing conductive material. As a result, the conductive materials that interfere with heating reproducibility are present, and the optimal conductive materials exist in each input voltage.

  • PDF

바닥충격음 차음성능평가에 있어서 측정 레벨의 허용오차에 관한 연구 (A Study on the Allowable Deviation for the Measured Level of the Impact Sound Insulation Performance)

  • 장길수;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 추계학술대회논문집; 한국과학기술회관; 6 Nov. 1997
    • /
    • pp.222-226
    • /
    • 1997
  • The reproducibility of measured level is a prior condition for the reliable assessment of the sound insulation performance. To review the reproducibility of impact sound level, 20 floors were selected in highrise apartment house, and then impact sound levels of two kinds of typical floors were measured with 10 times in each receiving point. The impact sound insulation class values were derived with a standard tapping machine and bang machine. Inspection of the result showed that smaller scale of the room caused to lower the reproducibility and that the higher values of standard deviation in lower frequency caused to deteriorate the reliability of assesment. Thus to enhance the reproducibility of the impact sound insulation class, greater allowable deviation of measured level is required in lower frequency than in higher one.

  • PDF

A Comparison on the Reproducibility of Parametric Bodies Used in the Virtual Garment System

  • Choi, Hee Eun;Nam, Yun Ja;Kim, Hye Suk
    • 한국의류산업학회지
    • /
    • 제16권2호
    • /
    • pp.266-274
    • /
    • 2014
  • Parametric bodies reproduce the actual shape of human body parts and should be convenient for general users to change size to judge the visual fit of clothes on-line. In this study, three parametric bodies(i.e. I, C, D ) were compared to verify the accuracy of the provided body dimensions and reproducibility to a target model. To compare reproducibility, the 20s female standard virtual model developed for an apparel industry by Korean agency for technology and standards is used. The investigation of existing parameters showed that the numbers and kinds of parameters provided by each program were different with some errors in notation; in addition, some of virtual body dimensions went beyond the maximum allowable error. The result of changing each parametric body to the 20s female standard body showed that D, C, I in order produced better reproducibility for body dimensions. There were different levels of protrusion and concavity in the virtual cross sections and virtual longitudinal sections despite the small differences in body dimensions and cross sectional areas; in addition, some parametric body was not bilateral symmetry. The results of this study can be used as basic information in the standardization of a virtual model used in a virtual garment program.

하악운동 재현성의 평가에 관한 비교연구 (An Evaluation of the Mandibular Movements Reproducibility by using Both Pantographic Reproducibility Index and BioEGN Reproducibility Index)

  • Kyung-Soo Han;Ho-In Jung
    • Journal of Oral Medicine and Pain
    • /
    • 제21권2호
    • /
    • pp.383-392
    • /
    • 1996
  • An observation and evaluation of the reproducibility of the mandibular movements has been a integral part of a test for mandibular function and dysfunction. After Pantographic Reproducibility Index(PRI) was introduced in dentistry, many authors have used the index for investigation of mandibular movement function, especially in condylar compartment. Howerer, the difficult and time-consuming work of instrumentation for getting the PRI has been a major obstacle in using pantograph. This study was performed to try a new mandibular reproducibility index, so-called BioEGN reproducibility index(BERI), calculated from mandibular trajectory recorded with BioEGN. 26 dental students without any signs and symptoms of temporomandibular disorders and 22 patients with temporomandibular disorders took part in this study and classed to control group and patients group, respectively. Pantronic and BioEGN were used to record and calculate the indices, PRI and BERI. PRI had only one value, but BERI had two values of outgoing and incoming movement in each scale. With two scales of small and large, as a result, BERI had four values in this study. PRI corresponded to BERI in small scale on outgoing total movements. The data were calculated and analyzed with SAS/stat program and the conclusion of this study were as follows : 1. In every scales, in each movement, BERI on outgoing movement in control group was lower than that in patients group, respectively, but BERI on incoming movement was only different in one side movement, that was, left excursion. 2. The difference between BERI on outgoing movement and BERI on incoming movement was only shown in small scale on total movements, not in each movement, in control group. However, there was generally a positive correlationship between BERI on outgoing movement and BERI on incoming movement in each movement in both groups. 3. Simple statistics of PRI was similar to that of BERI on total movements in small scale, but there was a negative correlation between PRI and BERI on total movements in large sclae only in patients group.

  • PDF

전기전도성 재료를 혼입한 콘크리트의 발열특성 및 재현성 평가 (Evaluation of the Exothermic Properties and Reproducibility of Concrete Containing Electro-conductive Materials)

  • 송동근;조형규;이한승
    • 한국건축시공학회지
    • /
    • 제16권1호
    • /
    • pp.25-34
    • /
    • 2016
  • 부도체로 알려져 있는 기존의 콘크리트에 전기 전도성 재료를 혼입하여 발열 콘크리트로서 개발하려는 연구가 90년대 이후 진행되어 왔다. 하지만 콘크리트 시험체의 발열 재현성 확보가 어려워 활발한 연구가 이루어지지 못했다. 이에 따라 본 연구에서는 융설용 재료로써 활용 가능한 발열 콘크리트 개발을 목적으로, 흑연, 금속분말, 혼화제를 혼입한 시멘트 페이스트 및 모르타르를 제작하여 $-2^{\circ}C$의 저온환경에서의 발열특성과 재현성을 평가하였다. 또한 미세화학분석을 통해 발현 재현성의 원인을 규명하고자 하였다. 실험 결과, 흑연과 고성능 AE감수제를 혼입한 시험체가 가장 우수한 발열 성능 및 재현 가능성을 보였다. 이에 따른 미세화학분석 결과, 고성능 AE 감수제 내의 폴리머 혹은 메타크릴산 성분이 흑연과 전기화학적 반응을 일으켜 발열 재현성능을 부여한 것으로 판단된다.

현대 예술 작품에 나타난 죽음의 미학 (The Aesthetics of Death of Works of Comtemporary Art)

  • 왕형우;김현주;윤지영
    • 디지털융복합연구
    • /
    • 제18권4호
    • /
    • pp.439-451
    • /
    • 2020
  • 본 연구는 현대 예술에서 나타난 죽음 미학의 의미를 깊게 이해하기 위해, 먼저 예술 작품에 담긴 죽음의 미학적 발전 과정을 통시적 관점으로 정리하고, 다음으로 현대 예술 작품에서의 죽음의 미학을 분류하고 의미를 살펴보았다. 본 연구의 결과는 다음과 같다. 첫째, 죽음의 미학적 표현 형식은 죽음의 재현과 죽음 상징의 두 가지로 구분한다. 죽음의 재현은 실질적 대상 재현, 상상의 대상 재현을 포함한다. 죽음의 상징적 표현은 외면적 표현 상징과 내면적 표현 상징으로 나눌 수 있다. 둘째, 현대 예술에서 죽음의 재현성 표현은 죽음의 장면에 대한 묘사를 통해 죽음으로 인한 다양한 문제 및 철학적 의미를 더한다. 셋째, 현대 예술에서 죽음의 상징적 의미는 죽음과 직접적으로 관련된 것뿐만 아니라 죽음에 따른 다양한 심리상태를 표현한다. 후속 연구에서는 예술 작품에서 죽음의 미학에 대한 작가의 시각적 표현과 그에 따른 심층적인 의미 변화를 진행할 것이다.

The Effect of Sample Handling on the Rheological Measurement of Regenerated Silk Fibroin Formic Acid Solution using Parallel Plate Geometry

  • Cho, Hee-Jung;Um, In-Chul
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제22권1호
    • /
    • pp.5-10
    • /
    • 2011
  • The effect of sample handling condition on the rheological measurement of regenerated silk fibroin formic acid solution using parallel plate geometry was investigated. In case of loading method, the loading by pouring sample solution resulted in the best reproducibility of rheological measurement. Loading with spoon showed a high variance of viscosity value at low shear rate region ($0.01{\sim}1sec^{-1}$) while loading with syringe exhibited a low reproducibility of viscosity at high shear region ($1{\sim}100sec^{-1}$) with a disappearance of shear thinning phenomenon. It was revealed that the sample loading with small extra amount lead to the most reproducible result. The sample loading with the exact amount for the measuring plate resulted in a lack of reproducibility of high shear viscosity, while the loading with large extra volume produced a limited consistency of low shear viscosity. It was turned out that 3 min. of waiting time before measurement was the optimum condition for reliable result. When the waiting time was less than 1 min., the low shear viscosity was obtained with a lack of consistency. On the other hand, the sample solution started drying when the waiting time increased up to 5 min.