Creep Damage Evaluation of High-Temperature Pipeline in Power Plant by Using Ultrasonic Velocity Measurement and Hardness Test (초음파 음속 및 경도법에 의한 발전소 고온배관재의 크리프 손상평가)

  • Hur, Kwang-Beom;Yoo, Keun-Bong;Cho, Yong-Sang;Lee, Sang-Guk
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.3 s.33
    • /
    • pp.92-99
    • /
    • 1999
  • High temperature and pressure materials in power plant are degraded by creep damage, if they are exposed to constant loads for long times, which occurs in load bearing structures of pressurized components operationg at elevated temperatures. Many conventional measurement techniques such as replica method, electric resistance method, and hardness test method for measuring creep damgage have been used. So far, the replica method is mainly used for the inspection of high temperature and pressure components. This technique is, however, restricted to applications at the surface of the testpieces and cannot be used to material inside. In this paper, ultrasonic evaluation for the detection of creep damage in the form of cavaties on grain boundaries or intergranular microcracks were carried out. And the absolute measuring method of quantitative ultrasonic velocity technique for Cr-Mo material degradation was analyzed. As a result of ultrasonic tests for crept for specimens, we founded that the sound velocity was decreased as increase of creep life fraction(${phi}c$) and also, confirmed that hardness was decreased as increase of creep life fraction(${phi}c$).

  • PDF

Vocal Enhancement for Improving the Performance of Vocal Pitch Detection (보컬 피치 검출의 성능 향상을 위한 보컬 강화 기술)

  • Lee, Se-Won;Song, Chai-Jong;Lee, Seok-Pil;Park, Ho-Chong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.6
    • /
    • pp.353-359
    • /
    • 2011
  • This paper proposes a vocal enhancement technique for improving the performance of vocal pitch detection in polyphonic music signal. The proposed vocal enhancement technique predicts an accompaniment signal from the input signal and generates an accompaniment replica signal according to the vocal power. Then, it removes the accompaniment replica signal from the input signal, resulting in a vocal-enhanced signal. The performance of the proposed method was measured by applying the same vocal pitch extraction method to the original and the vocal-enhanced signal, and the vocal pitch detection accuracy was increased by 7.1 % point in average.

Fractographic Analysis of Ceramic Composites by Transmission Electron Microscopy using Surface Replication Technique (표면복제법을 이용한 세라믹 복합재료 파괴현상의 투과전자현미경 분석)

  • Jun, Hyeung-Woo;Kim, Gyeung-Ho;Kim, Byung-Ho
    • Applied Microscopy
    • /
    • v.26 no.4
    • /
    • pp.447-456
    • /
    • 1996
  • Fracture surfaces of materials contain useful information ranging from crack path to the mechanism of fracture. Since limitation of electron transparency requires a sample in the form of thin foil for TEM observations, it is impossible to extract such information directly from the fracture surfaces. In this study, the method of surface replication from the ceramic fracture surface is employed to characterize the process of crack propagation in ceramic matrix composites using TEM analysis. The surface replica from the fracture surface in ceramic materials provides detailed surface morphology and more importantly, loosened particles on the fracture surface are collected. Electron diffraction and chemical composition analyses of these particles reveal crack path in the specimen. Furthermore, one can determine the mode of fracture by observing the fracture surface morphology from the image of replica. Two examples are given to illustrate the potential of the surface replication technique. In the first example, apparent toughness increase in $B_{4}C-Al$ composites at high strain rate is investigated by surface replication to elucidate the mechanism of fracture at different strain rates. The polytypes of SiC formed during the sintering of SiC-AlN composite and their effect on the fracture behavior of SiC-AlN composite are analyzed in the second example.

  • PDF

Comparison of the fit accuracy of zirconia-based prostheses generated by two CAD/CAM systems

  • Ha, Seok-Joon;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.6
    • /
    • pp.439-448
    • /
    • 2016
  • PURPOSE. The purposes of this study are to evaluate the internal and marginal adaptation of two widely used CAD/CAM systems and to study the effect of porcelain press veneering process on the prosthesis adaptation. MATERIALS AND METHODS. Molar of a lower jaw typodont resin model was prepared by adjusting a 1.0 mm circumferential chamfer, an occlusal reduction of 2.0 mm, and a $5^{\circ}$ convergence angle and was duplicated as an abrasion-resistant master die. The monolithic crowns and copings were fabricated with two different CAD/CAM system-Ceramil and Zirkonzahn systems. Two kinds of non-destructive analysis methods are used in this study. First, weight technique was used to determine the overall fitting accuracy. And, to evaluate internal and marginal fit of specific part, replica technique procedures were performed. RESULTS. The silicone weight for the cement space of monolithic crowns and copings manufactured with Ceramil system was significantly higher than that from Zirkonzahn system. This gap might cause the differences in the silicone weight because the prostheses were manufactured according to the recommendation of each system. Marginal discrepancies of copings made with Ceramil system were between 106 and $117{\mu}m$ and those from Zirkonzahn system were between 111 and $115{\mu}m$. Marginal discrepancies of copings made with Ceramil system were between 101 and $131{\mu}m$ and those from Zirkonzahn system were between 116 and $131{\mu}m$. CONCLUSION. Marginal discrepancy was relatively lower in Ceramil system and internal gap was smaller in Zirkonzahn system. There were significant differences in the internal gap of monolithic crown and coping among the 2 CAD/CAM systems. Marginal discrepancy produced from the 2 CAD/CAM systems were within a reported clinically acceptable range of marginal discrepancy.

Evaluation using Replica Technique on the marginal and internal fitness of zirconia cores by several CAD/CAM systems (수종의 CAD/CAM 시스템으로 제작한 지르코니아 코어에서 Replica Technique을 이용한 변연 및 내면 적합도 평가)

  • Huh, Jung-Bo;Park, Cheong-Gil;Kim, Ha-Young;Park, Chan-Kyung;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.135-142
    • /
    • 2010
  • Purpose: This study was aimed to compare the margin and internal fitness of single anterior all-ceramic crown zirconia core made by three deferent CAD/CAM systems. Material and methods: Five single zirconia cores were manufactured by three deferent CAD/CAM systems($Cerasys^{(R)}$system, KaVo $Everest^{(R)}$system, $LAVA^{TM}$system). The manufactured zirconia cores were duplicated through the use of replica technique, and a replicated sample was sectioned in the center of bucolingual and mesiodistal direction to measure the marginal and internal gap. Measurement was carried out by using measuring microscope ($AXIO^{(R)}$) and $I-Solution^{(R)}$ and analysed through the use of ANOVA. Results: As for the mean marginal fitness of the zirconia core, it was $84.74{\pm}27.57{\mu}m$, in $Cerasys^{(R)}$, $80.23{\pm}21.07{\mu}m$ in KaVo $Everest^{(R)}$ and $96.37 {\pm}11.45{\mu}m$ in $LAVA^{TM}$, and as for the mean internal gap, it was $94.11{\pm}30.07{\mu}m$ in $Cerasys^{(R)}$, $92.31{\pm}25.18{\mu}m$ in KaVo $Everest^{(R)}$, and $94.99{\pm}18.74 {\mu}m$ in $LAVA^{TM}$. There was no significant statistically deference among the total average gap of three systems. The internal gap in KaVo $Everest^{(R)}$ seemed to be smaller than $LAVA^{TM}$ (P < .05). The internal gap in the incisal area was larger in all of the three systems. Conclusion: There was no difference in marginal fitness in $Cerasys^{(R)}$, KaVo $Everest^{(R)}$ and $LAVA^{TM}$. As for the internal fitness, it was smaller in KaVo $Everest^{(R)}$ system than $LAVA^{TM}$ system. In all of the three systems, there was a larger gap in incisal area. The marginal and internal gap was within the clinically allowed range in all of the three systems.

Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes

  • von Maltzahn, Nadine Freifrau;Bernhard, Florian;Kohorst, Philipp
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.2
    • /
    • pp.100-106
    • /
    • 2020
  • PURPOSE. The purpose of this in vitro study was to evaluate the fitting accuracy of single crowns made from a novel presintered Co-Cr alloy prepared with a computer-aided design and computer-aided manufacturing (CAD/CAM) technique, as compared with crowns manufactured by other digital and the conventional casting technique. Additionally, the influence of oxide layer on the fitting accuracy of specimens was tested. MATERIALS AND METHODS. A total of 40 test specimens made from Co-Cr alloy were investigated according to the fitting accuracy using a replica technique. Four different methods processing different materials were used for the manufacture of the crown copings (milling of presintered (Ceramill Sintron-group_cer_sin) or rigid alloy (Tizian NEM-group_ti_nem), selective laser melting (Ceramill NPL-group_cer_npl), and casting (Girobond NB-group_gir_nb)). The specimens were adapted to a resin model and the outer surfaces were airborne-particle abraded with aluminum oxide. After the veneering process, the fitting accuracy (absolute marginal discrepancy and internal gap) was evaluated by the replica technique in 2 steps, before removing the oxide layer from the intaglio surface of the crowns, and after removing the layer with aluminum oxide airborne-particle abrasion. Statistical analysis was performed by multifactorial analysis of variance (ANOVA) (α=.05). RESULTS. Mean absolute marginal discrepancy ranged between 20 ㎛ (group_cer_npl for specimens of Ceramill NPL) and 43 ㎛ (group_cer_sin for crowns of Ceramill Sintron) with the oxide layer and between 19 ㎛ and 28 ㎛ without the oxide layer. The internal gap varied between 33 ㎛ (group_ti_nem for test samples of Tizian NEM) and 75 ㎛ (group_gir_nb for the base material Girobond NB) with the oxide layer and between 30 ㎛ and 76 ㎛ without the oxide layer. The absolute marginal discrepancy and the internal gap were significantly influenced by the fabrication method used (P<.05). CONCLUSION. Different manufacturing techniques had a significant influence on the fitting accuracy of single crowns made from Co-Cr alloys. However, all tested crowns showed a clinically acceptable absolute marginal discrepancy and internal gap with and without oxide layer and could be recommended under clinical considerations. Especially, the new system Ceramill Sintron showed acceptable values of fitting accuracy so it can be suggested in routine clinical work.

Effect of heat treatment of core fabricated by Ni-Cr alloy on marginal and internal fit (열처리가 Ni-Cr 합금으로 제작된 하부구조물의 변연 및 내면 간격에 미치는 영향)

  • Kim, Jae-Hong;Kim, Ki-Baek;Jung, Jae-Kwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.9
    • /
    • pp.244-250
    • /
    • 2017
  • The most important aspect determining the completeness of aprosthesis is itsmarginal and internal fit. Alloysare processed using a softening/hardening heat treatment methodin order to improve their mechanical, physical properties and polishing properties. To examinehow the heat treatment method affects the marginal and internal fit of the Ni-Cr alloy core,thirty dental stone models of the abutment of the mandibular left molar were manufactured.The Ni-Cr alloy coreswere manufactured by the dipping method for the experiment and dividedinto three groups; A for no heat treatment, B for softening heat treatment and C for hardening heat treatment. The marginal and internal fitsof all of the groups were measured by the silicone replica technique. A statistical analysis was performed using one-way ANOVA(${\alpha}=0.05$) in order to examine whether there is a significant difference in the average values of the marginal and internal fits among the three groups and it was found that themarginal fits (1, 6) were significantly different (p<0.05), but the internal fits (2, 3, 4, 5) were not significantly different (p>0.05). These results show that Ni-Cr alloys should not be processed bythe heat treatmentmethod.However, they need to be confirmed in further clinical application studies.

Evaluation of the marginal and internal gap of metal-ceramic crown fabricated with a selective laser sintering technology: two- and three-dimensional replica techniques

  • Kim, Ki-Baek;Kim, Jae-Hong;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.2
    • /
    • pp.179-186
    • /
    • 2013
  • PURPOSE. One of the most important factors in evaluating the quality of fixed dental prostheses (FDPs) is their gap. The purpose of this study was to compare the marginal and internal gap of two different metal-ceramic crowns, casting and selective laser sintering (SLS), before and after porcelain firing. Furthermore, this study evaluated whether metal-ceramic crowns made using the SLS have the same clinical acceptability as crowns made by the traditional casting. MATERIALS AND METHODS. The 10 study models were produced using stone. The 20 specimens were produced using the casting and the SLS methods; 10 samples were made in each group. After the core gap measurements, 10 metal-ceramic crowns in each group were finished using the conventional technique of firing porcelain. The gap of the metal-ceramic crowns was measured. The marginal and internal gaps were measured by two-dimensional and three-dimensional replica techniques, respectively. The Wilcoxon signed-rank test, the Wilcoxon rank-sum test and nonparametric ANCOVA were used for statistical analysis (${\alpha}$=.05). RESULTS. In both groups, the gap increased after completion of the metal-ceramic crown compared to the core. In all measured areas, the gap of the metal cores and metal-ceramic crowns produced by the SLS was greater than that of the metal cores and metal-ceramic crowns produced using the casting. Statistically significant differences were found between cast and SLS (metal cores and metal-ceramic crown). CONCLUSION. Although the gap of the FDPs produced by the SLS was greater than that of the FDPs produced by the conventional casting in all measured areas, none exceeded the clinically acceptable range.

Provisioning Scheme of Large Volume File for Efficient Job Execution in Grid Environment (그리드 환경에서 효율적인 작업 처리를 위한 대용량 파일 프로비저닝 방안)

  • Kim, Eun-Sung;Yeom, Beon-Y.
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.8
    • /
    • pp.525-533
    • /
    • 2009
  • Staging technique is used to provide files for a job in the Grid. If a staged file has large volume, the start time of the job is delayed and the throughput of job in the Grid may decrease. Therefore, removal of staging overhead helps the Grid operate more efficiently. In this paper, we present two methods for efficient file provisioning to clear the overhead. First, we propose RA-RFT, which extends RFT of Globus Toolkit and enables it to utilize RLS with replica information. RA-RFT can reduce file transfer time by doing partial transfer for each replica in parallel. Second, we suggest Remote Link that uses remote I/O instead of file transfer. Remote link is able to save storage of computational nodes and enables fast file provisioning via prefetching. Through various experiments, we argue that our two methods have an advantage over existing staging techniques.