Browse > Article
http://dx.doi.org/10.4047/jkap.2010.48.2.135

Evaluation using Replica Technique on the marginal and internal fitness of zirconia cores by several CAD/CAM systems  

Huh, Jung-Bo (Department of Advanced Prosthetic Dentistry, Graduate School of Clinical Dentistry, Korea University)
Park, Cheong-Gil (Department of Advanced Prosthetic Dentistry, Graduate School of Clinical Dentistry, Korea University)
Kim, Ha-Young (Department of Advanced Prosthetic Dentistry, Graduate School of Clinical Dentistry, Korea University)
Park, Chan-Kyung (Department of Advanced Prosthetic Dentistry, Graduate School of Clinical Dentistry, Korea University)
Shin, Sang-Wan (Department of Advanced Prosthetic Dentistry, Graduate School of Clinical Dentistry, Korea University)
Publication Information
The Journal of Korean Academy of Prosthodontics / v.48, no.2, 2010 , pp. 135-142 More about this Journal
Abstract
Purpose: This study was aimed to compare the margin and internal fitness of single anterior all-ceramic crown zirconia core made by three deferent CAD/CAM systems. Material and methods: Five single zirconia cores were manufactured by three deferent CAD/CAM systems($Cerasys^{(R)}$system, KaVo $Everest^{(R)}$system, $LAVA^{TM}$system). The manufactured zirconia cores were duplicated through the use of replica technique, and a replicated sample was sectioned in the center of bucolingual and mesiodistal direction to measure the marginal and internal gap. Measurement was carried out by using measuring microscope ($AXIO^{(R)}$) and $I-Solution^{(R)}$ and analysed through the use of ANOVA. Results: As for the mean marginal fitness of the zirconia core, it was $84.74{\pm}27.57{\mu}m$, in $Cerasys^{(R)}$, $80.23{\pm}21.07{\mu}m$ in KaVo $Everest^{(R)}$ and $96.37 {\pm}11.45{\mu}m$ in $LAVA^{TM}$, and as for the mean internal gap, it was $94.11{\pm}30.07{\mu}m$ in $Cerasys^{(R)}$, $92.31{\pm}25.18{\mu}m$ in KaVo $Everest^{(R)}$, and $94.99{\pm}18.74 {\mu}m$ in $LAVA^{TM}$. There was no significant statistically deference among the total average gap of three systems. The internal gap in KaVo $Everest^{(R)}$ seemed to be smaller than $LAVA^{TM}$ (P < .05). The internal gap in the incisal area was larger in all of the three systems. Conclusion: There was no difference in marginal fitness in $Cerasys^{(R)}$, KaVo $Everest^{(R)}$ and $LAVA^{TM}$. As for the internal fitness, it was smaller in KaVo $Everest^{(R)}$ system than $LAVA^{TM}$ system. In all of the three systems, there was a larger gap in incisal area. The marginal and internal gap was within the clinically allowed range in all of the three systems.
Keywords
CAD/CAM; Zirconia core; Marginal fitness; Internal fitness;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Jorgensen KD. Factors affecting the film thickness of zinc phosphate cement. Acta Odontol Scan 1960;18:479-90.   DOI
2 McLean JW, von Fraunhofer JA. Polycarboxylate cements.: Five years'experience in general practice. Br Dent J 1972; 132:9-15.   DOI   ScienceOn
3 Pera P, Bassi F, Carossa S. In vitro marginal adaptation of alumina porcelain ceramic crown. J Prosthet Dent 1994;72:585-90.   DOI   ScienceOn
4 Bindle A, Mormann WH. Marginal and internal fit of allceramic CAD/CAM crown-coping on chamfer preparations. J Oral Rehabil 2005;32:441-7.   DOI   ScienceOn
5 Valderrama. S, Roekel NV, Andersson M, Goodacre CJ, Munoz CA. A comparison of the marginal and internal adaptation of titanium and gold-platinum-palladium metal ceramic crowns. Int J Prosthodont 1995;8:29-37.
6 Molin M, Karlsson S. The fit of gold inlays and three ceramic inlay system. Aclinical and in vitro study. Acta Odontol Scand 1993;51:201-16.   DOI   ScienceOn
7 Habib Y, Georges E, Salim M, Albert S, Khaldoun T. In vitro evaluation of the "Replica Technique" in the measurement of the fit of Procera crown. J Contemp Dent Pract 2008;9:25-32.
8 Davis DR. Comparison of fit of two types of all ceramic crowns. J Prosthet Dent 1988;59:13-6.
9 Abbate MF, Tjan A, Fox WM. Comparison of marginal fit of various ceramic crown systems. J Prosthet Dent 1989;61:527-31.   DOI   ScienceOn
10 Belser UC, Mecentee MI, Richter WA. Fit of three porcelain-fusedto metal marginal designs in vivo: a scanning electron microscope study. J Prosthet Dent 1985;53:24-9.   DOI   ScienceOn
11 Hertlein G, Hoscheler S, Frank S, Suttor D. Marginal fit of CAD/CAM manufactured all ceramic prosthesis. J Dent Res 2001;80:42-4.
12 Strawn SE, White JM, Marshall GW, Gee L, Goodis HE, Marchall SJ. Spectroscopic changes in human dentin exposed to various storage solution-short term. J Dent 1996;24:417-23.   DOI   ScienceOn
13 Kim DK, Cho IH, Lim JH, Lim HS. On the marginal fidelity of allceramic core using CAD/CAM system. J Korean Acad Prosthodont 2003;41:20-34.   과학기술학회마을
14 Yang JH, Yeo IS, Lee SH, Han JS, Lee JB. Marginal fit of Celay/In-Ceram, conventional In-Ceram and Empress 2 all-ceramic single crowns. J Korean Acad Prosthodont 2002;40:131-9.   과학기술학회마을
15 Carter JM, Sorensen SE, Johnson RR, Teitelbaum RL, Levine MS. Punch shear testing of extracted vital and endodontically treated teeth. J Biomech 1983;16:841-8.   DOI   ScienceOn
16 Koo JY, Lim JH, Cho IH. Marginal fidelity according to the margin types of all ceramic crowns. J Korean Acad Prosthodont 1997;35:445-57.
17 Sorensen JA. A standardized method for determination of crown margin. J Prosthet Dent 1990;64:18-24.   DOI   ScienceOn
18 Moon BH, Yang JH Lee SH, Chung HY. A study on the marginal fit of all-ceramic crown using ccd camera. J Korean Acad Prosthodont 1998;36:273-92.
19 Schwartz N, Whitsett L, Berry T, Stewart J. Unserviceable crowns and fixed partial dentures: lifespan and causes for loss of serviceability. J Am Dent Assoc 1970;81:1395-401.   DOI
20 Felton D, Kanoy B, Bayne S, Wirthman G. Effect of in vivo crown margin discrepancies on periodontal health. J Prosthet Dent 1991;65:357-64.   DOI   ScienceOn
21 Walton J, Gardner F, Agar J. A survey of crown and fixed partial denture failures: length of service and reasons for replacement. J Prosthet Dent 1986;56:416-21.   DOI   ScienceOn
22 Council on dental materials and devices. Revised american national standards institute/American dental association specification No. 8 for zinc phosphate cement. J Am Dent Assoc 1978;96:121-3.   DOI
23 Christensen GJ. Marginal fit of gold castings. J Prosthet Dent 1966;16:297-305.   DOI   ScienceOn
24 McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J 1971;131:107-11.   DOI   ScienceOn
25 Hung SH, Hung KS, Eick JD, Chappel RP. Marginal fit of porcelain- fused-to metal and two types of ceramic crown. J Prosthet Dent 1990;63:26-31.   DOI   ScienceOn
26 May KB, Russell MM, Razzoog ME, Lang BR. Precision of fit: the procera Allceram crown. J Prosthet Dent 1998;80:394-404.   DOI   ScienceOn
27 Jeon MH, Jeon YC, Jeong CM, Lim JS, Jeong HC. A study of precise fit of the CAM zirconia all-ceramic framework. J Korean Acad Prosthodont 2005;43:611-21.   과학기술학회마을
28 Sturdevant JR, Bayne SC, Heymann HO. Margin gap size of ceramic inlays using second-generation CAD/CAM equipment. J Esthet Dent 1999;11:206-14.   DOI
29 Tinschert J, Natt G, Mautsch, Spikermann H, Anusavice KJ. Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system. Oper Dent 2001;26:367-74.
30 Lawn BR, Deng Y, Thompson VP. Use of contact testing in the characterization and design of all-ceramic crown-like layer structures: a review. J Prosthet Dent 2001;86:495-510.   DOI   ScienceOn
31 Seo JY, Park IN, Lee KW. Fracture strength between different connector designs of zirconia core for posterior fixed partial dentures manufactured with CAD/CAM system. J Korean Acad Prosthodont 2006;44:29-39.   과학기술학회마을
32 Bader J, Rozier R, McFall W Jr, Ramsey D. Effect of crown margins on periodontal conditions in regularly attending patients. J Prosthet Dent 1991;65:75-9.   DOI   ScienceOn
33 Seghi PR, Sorensen JA. Relative flexural strength of six new ceramic materials. Int J Prosthodont 1995;8:239-46.
34 Grasso J, Nalbandian J, Sanford C, Baili H. Effect of restoration quality on periodontal health. J Prosthet Dent 1985;53:14-9.   DOI   ScienceOn
35 Andersson M, Razzoog ME, Ode′n A, Hegenbarth EA, Lang BR. Procera: a new way to achieve an all-ceramic crown. Quintessence Int 1998;29:285-96.
36 Boening KW, Wolf BH, Schmidt AE, K¨astver K, Walter MH. Clinical fit of Procera Allceram crowns. J Prosthet Dent 2000;84:419-24.   DOI   ScienceOn