• 제목/요약/키워드: Replacement Ratio

검색결과 1,414건 처리시간 0.024초

승모판막 치환술후 조기사망의 술전 및 술중 위험인자에 대한 임상적 고찰 (A Clinical Study for Pre- and Intraoperative Risk Factors of Hospital Mortality after Mitral Valve Replacement)

  • 박승규
    • Journal of Chest Surgery
    • /
    • 제23권2호
    • /
    • pp.236-244
    • /
    • 1990
  • To improve the prognosis of mitral valve replacement surgery, analysis and evaluation of pre and intra operative risk factors will be very much valuable. Author studied 205 cases of mitral valve replacement from Feb 1982 to June 1989 for the risk factors of hospital death. 90 patients were male and 115 were female, and age was from 16 to 59 years, Mitral stenosis dominant lesions were 91 cases and regurgitation 114. Suspected risk factors were NYHA functional class, cardiothoracic ratio, implanted valve type and size, operation time, age and sex, thrombus in left atrium, atrial fibrillation, aortic cross clamping time, left ventricular end diastolic and systolic dimension, nephropathy, hepatopathy and respiratory insufficiency. Statistic analysis was performed by X2 test between survivors and death group. Statistical significances as pre and intraoperative risk factors of hospital death after mitral valve replacement were confirmed in those presence of AF on the EKG, NYHA functional class[>IV], cardiothoracic ratio[>70%], and implanted valve size[>33mm]

  • PDF

잔골재 종류 및 치환율에 따른 저탄소 무기결합재의 유동 및 강도특성 (Flowing and Strength Properties of Low Carbon Inorganic Composite Depending to Fine Aggregate Types and Replacement Ratio)

  • 박종필;배상우;이윤성;이강필;이상수;송하영
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.235-236
    • /
    • 2011
  • This study analyzed flowing and strength properties of mortar depending to fine aggregate types and replacement ratio by using blast furnace slag, red mud, and silica fume that are industrial by products. The findings showed that higher replacement level of fine aggregate increased air content while decreased table flow. In addition, compressive strength showed that the higher replacement level was regardless of fine aggregate types, the lower strength became. Mortar substituted by the dredged sand showed high strength.

  • PDF

고로슬래그 미분말을 사용한 콘크리트의 방청성능에 관한 연구 (A Study on the Rust-protection Performance of Concrete using Ground Granulated Blast-furnace Slag)

  • 박상준;김동석;원철;이상수;김영진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.529-532
    • /
    • 2001
  • In this paper, rust-protection performance of concrete using ground granulated blast-furnace slag are discussed. 4 kinds of W/B in combination with 3 kinds of replacement ratio of ground granulated blast-furnace slag and 2 kinds of chloride ion contents of are selected as experimental parameters. According to the experimental results, as the replacement ratio of ground granulated blast-furnace slag is increased, the corrosion area of steel bar tends to be decreased. However, as the autoclave cycle and chloride ion contents are increased, the corrosion area of steel bar is increased. In conclusion, when the replacement ratio of ground granulated blast-furnace slag is 50%, the strength and rust-protection performance appear to be most excellent.

  • PDF

리젝트애쉬를 사용한 콘크리트 특성 (The Properties of Concrete with Reject Ash)

  • 백철우;김호수;박조범;류득현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.481-484
    • /
    • 2006
  • The purpose of this study is to present the recycling method of reject-ash. The reject-ash, a significant portion of the pulverized fuel ash produced by coal-fired power plants and rejected from the ash classifying process, has remained unused due to its high carbon content and large particle size. This study compared reject-ash with fly-ash by physical properties, the properties of fresh & harden concrete with cement replacement ratio of reject-ash and fly-ash, 0, 5, 10, 15, 20, 25(wt. %). The loss of ignition of the reject-ash is similar to fly-ash and is suited to the KS L 5405. When the replacement ratio of reject-ash is increasing the air content of reject-ash concrete is lowly decreased. The results of the compressive strength measurement of reject-ash tends to decrease by increasing the replacement ratio.

  • PDF

산업부산물을 활용한 조강형 결합재의 치환율에 따른 조기강도 특성에 관한 연구 (A Study on the Properties of Early Strength with the Replacement Ratio of Early Strength Type Binder Using Industrial By-product)

  • 전우철;권해원;서휘완;이재삼
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.254-255
    • /
    • 2014
  • This study is a part of development to improve early-age compressive strength of concrete by using industrial by-products. It tried to investigate the characteristics of early-age compressive strength according to curing temperature and industrial by-product replacement ratio 10, 20, and 30 %. As a result, regardless of industrial by-product replacement ratio and age, early-age compressive strength of concrete was found to be high compared to Plain using 100 % cement.

  • PDF

고강도 경량 자기충전콘크리트의 성능평가 (Properties of High Strength Lightweight Self-Compacting Concrete)

  • 최연왕;문대중;안성일;최욱;조선규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.413-416
    • /
    • 2003
  • Experimental tests on the high strength self-compacting concrete with light-weight fine aggregate and light-weight coarse aggregate(LHSSC) were performed with slump-flow, reaching time to the slump-flow of 500mm, V-funnel dropping time and U-box difference level and compressive strength. LHSCC with light-weight fine aggregate of 75% and light-weight coarse aggregate of 100% was only satisfied with the property conditions of second self-compacting concrete(SCC), like as flowability, resistance to segregation and filling ability. The 28-day compressive strength of LHSCC indicated above 300kgf/$\textrm{cm}^2$ in all concrete mixtures, and it was increased to increase the replacement ratio of light-weight fine aggregate or to decrease the replacement ratio of light-weight coarse aggregate. Therefore, for satisfying the properties of fresh SCC and hardened concrete with above 350kgf/$\textrm{cm}^2$, it would expected that the replacement ratio of light-weight fine aggregate and light-weight coarse aggregate will be determined with 50~75% and 25~50%, respectively.

  • PDF

보증분석을 위한 품질보증 기간 중 제품 교체율 추정 사례 연구 (Estimation of a Product Replacement Ratio During the Warranty Period for a Warranty Analysis)

  • 안해일
    • 산업경영시스템학회지
    • /
    • 제35권2호
    • /
    • pp.71-79
    • /
    • 2012
  • In this paper, an evaluation of a product replacement ratio of irreparable items to the normally working ones is performed with a view to a warranty analysis. It is demonstrated that the replacement ratio during the warranty period can be estimated from the field data collected during the period of operation, and one can provide the management with a useful information regarding the appropriateness for the warranty period, which is vital to the product marketing strategy. Although warranty data usually take the form of multiply right censored interval data, the conventional reliability analysis method seems to be good enough as in this case. More sophisticated method such as warranty cost analysis and 2-dimensional warranty analysis is yet desired.

쇄석말뚝의 지지력 특성에 관한 모형시험 연구 (A Model Test Study on the Bearing Capacity of the Crushed Stone Pile)

  • 이상익;박용원;김병일;윤길림
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.299-306
    • /
    • 2001
  • Crushed Stone Pile(CSP) is one of the ground improvement methods available to loose sand and clayey ground by forming compacted CSP in the weak soil layer. The effects of this method are enhancement of ground bearing capacity, reduction of settlement and prevention of lateral ground movement in cohesive layer, reduction of liquefaction potential in sandy ground. This study performs model tests in 1.0m${\times}$1.0m${\times}$1.0m and 1.5m${\times}$1.5m${\times}$l.2m model tank to observe bearing capacity of CSP treated ground. The area replacement ratio of CSP composite ground varies 20%, 30% and 40% with square grid pattern. After the composite ground was consolidated under pressure of 0.5kg/$\textrm{cm}^2$ and 1.0kg/$\textrm{cm}^2$, load tests were carried out. The results show that ultimate bearing capacity increases with area replacement ratio and the preconsolidation pressure of ground.

  • PDF

폴리실리콘 슬러지와 플라이애쉬 치환율별 역학성능 평가 (The Dynamics Performance Evaluation for Type of Replacement Ratio of the Polysilicon Sludge and Fly ash)

  • 문지환;박종필;김규용;이상수;송하영
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.85-86
    • /
    • 2012
  • This application plan is hasty prepared with the actual condition in which the majority is reclaimed by the waste with the marine and the polysilicon sludge, that is the main raw material of the solar pannel support, does. In this research, by using OPC and Fly ash, the applicability as the blending material of the polysilicon sludge was analyze and it tried to contribute to the waste reduction afterward. The replacement ratio of the sludge was set to 5. 10, 15, 20(%) with the experiment based on the based test result and the air flow rate, liquidity, flexural strength, and compressive strength was measured. The liquidity was reduced in spite of as the replacement ratio of the sludge increased and the air flow rate increased.

  • PDF

플라이 애쉬를 다량 치환한 콘크리트의 중성화 특성에 관한 실험적 연구 (The Experimental Study on Neutralization Properties of High Volume Fly-Ash Concrete)

  • 백민수;김우상;김종원;김제섭;김성식;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.69-74
    • /
    • 2003
  • This study evaluated durability through measurement of substituted test piece's pH degree and experiments of neutralization. Comparing and evaluating cared test piece's pH degrees which we got before the neutralization and after the neutralization. After evaluating neutralization depth through neutralization, evaluating neutralization properties by Fly Ash replacement ratio. pH degree was decreased by cement replacement ratio of Fly Ash. And in the case of substitution of the same amount of Fly Ash, fine aggregate replacement ratio was increased. When the test piece, which had been cared in high temperature, was promoted to neutralization, Among the test piece which was replaced with Fly Ash 40%, the test piece which has high rate of fine aggregate proved opposition of neutralization Through the test, Ⅰ summarized that the test piece cared in high temperature was mostly effected by compress strength, the test piece cared in low temperature was mostly effected by pH degree.

  • PDF