• Title/Summary/Keyword: Repetition rate

Search Result 434, Processing Time 0.028 seconds

Marx Generator Implementation Using IGBT Stack (IGBT 스택을 이용한 Marx Generator 구현)

  • Kim, J.H.;Min, B.D.;Kim, J.S.;Rim, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.507-510
    • /
    • 2005
  • High voltage pulse power supply using Marx generator and solid-state switches is proposed in this study. The Marx generator is composed of 12 stages and each stage is made of IGBT stack, two diode stacks, and capacitor. To charge the capacitors of each stage in parallel, inductive charging method is used and this method results in high efficiency and high repetition rates. It can generate the pulse voltage with the following parameters: Voltage: up to 120kv Rising time: sub ${\mu}S$ Pulse width: up to $10{\mu}S$, Pulse repetition rate: 1000pps The proposed pulsed power generator uses IGBT stack with a simple driver and has modular design. So this system structure gives compactness and easiness to implement total system. Some experimental results are included to verify the system performances in this paper.

  • PDF

A Design and Implementation of 30w class Er:YAG laser adopted skin and dental clinic. (치과 및 교부과용 30W급 Er:YAG 레이저 설계 및 구현)

  • 김휘영;신경애
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.211-214
    • /
    • 2001
  • For general laser power supply, the secondary of the power transformer is connected to the rectifier and filter capacitor. The output of a rectifier is connected to a switching element in the secondary of the transformer. So the Dower supply is complicated and the loss of switching is considerably. In addition, according to increasing pulse repetition, charged energy of energy-storage capacitor is not transferred sufficiently to flashlamp, and laser output efficiency decreases. In this raper, to improve laser efficiency, we designed and fabricated the power supply in which the SCR was turned on in zero point by the methods of ZCC(zero crossing control), PFN(pulse forming network) in result, laser output efficiency increased by hte 4% other than conventional supply, when a repetition rate was increased by the 10[pps], In 20(pps), efficiency was increased by about 8%

  • PDF

The development of a high efficient transcranial magnetic stimulation adopted real time-charging-discharging circuit

  • Kim, Whi-Young;Park, Sung-Joon
    • Journal of IKEEE
    • /
    • v.14 no.2
    • /
    • pp.9-15
    • /
    • 2010
  • In this study, we have been proposed the new type of a transcranial magnetic stimulation adopted a variable voltage capacitor with Cockcroft-Walton circuit and constant-frequency current resonant half-bridge inverter. This a transcranial magnetic stimulation has some merits compared with the conventional one. First, it doesn't require the high voltage transformer. And second, it has less switching losses, compact size and capability in adjusting the transcranial magnetic stimulation output energy precisely. In this paper, we have performed the output characteristics of a transcranial magnetic stimulation system which is well known as magnetic stimulation. The tested results are described as a function of pulse repetition rate and switching numbers of the half-bridge inverter.

Development of High Flux Metal Ion Plasma Source for the Ion Implantation and Deposition

  • Kim, Do-Yun;Lee, Eui-Wan
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.7 no.2
    • /
    • pp.45-56
    • /
    • 2003
  • A high flux metal plasma pulse ion source, which can simultaneously perform ion implantation and deposition, was developed and tested to evaluate its performance using the prototype. Flux of ion source was measured to be 5 A and bi-polar pulse power supply with a peak voltage of 250 V, repetition of 20 Hz and width of 100 ${\mu}\textrm{s}$ has an output current of 2 kA and average power of 2 kW. Trigger power supply is a high voltage pulse generator producing a peak voltage of 12 kV, peak current of 50 A and repetition rate of 20 Hz. The acceleration column for providing target energy up to ion implantation is carefully designed and compatible with UHV (ultra high vacuum) application. Prototype systems including various ion sources are fabricated for the performance test in the vacuum and evaluated to be more competitive than the existing equipments through repeated deposition experiments.

  • PDF

Laser application in 3-D micromachining (레이져를 이용한 3차원 형상가공에 관한 연구)

  • 윤경구;이성국;황경현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.75-78
    • /
    • 1995
  • This paper presents the feasibility of laser ablation process in 3-D micro machining of MEMS (micro Electro Mechanical System)parts. The micro machining characteristics of polymer(Energy fluence, pulse repetition rate, number of pulse, ablation rate)are investigated and 3-D micro machined samples are demonstrated.

  • PDF

Micro-Processing of Glass Substrates Using a Laser (레이저를 이용한 유리기판의 미세가공(微細加工))

  • Lee, Cheon;Toyoda, Koichi
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1425-1427
    • /
    • 1994
  • Laser ablation of glass substrates (8K-7 and synthetic quartz) using a transversely excited atmospheric (TEA) $CO_2$ laser has been inverstigated to obtain high speed etching. The ablation occurs by local heating of a substrate with a focused TEA-$CO_2$ laser beam. The dependence of ablation rate on pulse count and repetition-rate of laser has been discussed.

  • PDF

Ablation Rate and Intrapulpal Temperature by Addition of Water Spray During Er:YAG Laser Irradiation (Er:YAG laser를 이용한 치아삭제시 물분사량이 삭제율과 치수내 온도변화에 미치는 영향)

  • Kim, Jung-Moon;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.3
    • /
    • pp.375-381
    • /
    • 2005
  • Er:YAG laser has been considered a promising alternative to dental drill and many researches indicate that adjustment to variable parameters, including water flow rate, pulse energy and pulse repetition rate, can be made to improve ablation ability and efficiency of the laser. Of these parameters, addition of water spray during irradiation has been thought to ablate dental hard tissue more rapidly and safely. The purpose of this study was to investigate tooth ablation amount by Er:YAG laser irradiation as related to varied water flow rates added and, ultimately to find the most effective water flow rate for ablation. In addition, the temperature change of pulp chamber during irradiation was also monitored on the irradiated and opposite pulpal walls, respectively. An Er:YAG laser with contact mode was employed. Extracted human molars were split into two pieces for ablation experiment. Pulse energies of 200 and 300 mJ with a pulse repetition rate of 20 Hz and 5 water flow rates (1.6, 3.0, 5.0, 7.0, and 10.0 ml/min) were applied. Each irradiation was performed for 3 seconds. According to these parameters, experimental groups were divided into 10 subgroups which consisted of 5 specimens. For temperature experiment, another 5 tooth-specimens were prepared in the manner that pulp chamber was open through access cavity preparation and two temperature-measuring probes were placed respectively on the irradiated and the opposite walls of pulp chamber. From the experiment on ablation amount related to different water flow rates, it was shown that the least water flow rate of 1.6 ml/min ablated more than any other water flow rates (p<0.000). When the irradiation for 3 seconds, combined with the pulse repetition time of 20Hz and the water flow rate of 1.6 ml/min was done to tooth specimen, the temperature rise was not noticeable both on the irradiated and the opposite pulpal walls (less than 3$^{\circ}C$) and there was no significant difference in temperature rise between the two pulse energies, 200 and 300 mJ. From the results of this study, it is suggested that tooth ablation with Er:YAG laser can be done effectively and safely at a energy between 200 and 300 mJ/pulse and a pulse repetition rate of 20 Hz when the lasing is conjugated with the water flow rate of 1.6ml/min.

Error Rate Performance of FH/MFSK Signal with Diversity and Coding Technique in the Interference and Fading Environments (간섭과 페이딩 환경하에서 다이버시티와 부호화 기법을 이용하는 FH/MFSK 신호의 오율 특성)

  • 이문승;심수보
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.11
    • /
    • pp.1311-1319
    • /
    • 1992
  • In the partial-band interference and Rayleigh fading environments, the bit error probability equation of FH/MFSK signal has been derived and the error rate has been evaluated. And the results are shown in graphs and discussed. Here, to improve the error rate performance the repeated diversity and the error-correction coding techniques are adopted. The degree of improvement of error rate performance has been found out in diversity and coding techniques respectively. In diversity case, repetition number is taken as a parameter and in coding case, as the error-correction codes Hamming code, BCH code, and convolutional code are introduced. From the obtained results, we have known that the increase of the number of repetition in diversity technique has been brought a little improvement of performance but the coding technique considerable improvement and in particular, convolutional code is very effective. Therefore, coding technique is considered to be better than repeated diversity to cope with Rayleigh fading and partial-band interference.

  • PDF

A Study af Speech Rate and Fluency in Narmal Speakers (정상 성인의 말속도 및 유창성 연구)

  • Shin, Moon-Ja;Han, Sook-Ja
    • Speech Sciences
    • /
    • v.10 no.2
    • /
    • pp.159-168
    • /
    • 2003
  • The purpose of this study was to assess the speech rate, fluency and the type of dysfluencies of normal adults in order to provide a basic data of normal speaking. The number of subjects of this study were 30(14 females and 16 males), and their ages ranged 17 to 36. The rate was measured as syllables per minute (SPM). The speech rates in reading ranged 273-426 with a mean of 348 SPM and in speaking ranges 118-409 (mean=265). The average of their fluencies was 99.1% in reading and 96.9% in speaking. The rater reliability of speech rate in the data assessed by video was very high (r=0.98) and the rater reliability of speech fluency was moderately high (r=0.67). The disfluency types were also analysed from 150 disfluency episodes. Syllable repetition and word interjection were the most common disfluent types.

  • PDF

Vulnerability Analysis of Network Communication Device by Intentional Electromagnetic Interference Radiation (IEMI 복사에 의한 네트워크 통신 장비의 취약성 분석)

  • Seo, Chang-Su;Huh, Chang-Su;Lee, Sung-Woo;Jin, In-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.1
    • /
    • pp.44-49
    • /
    • 2018
  • This study analyzed the Vulnerability of Network Communication devices when IEMI is coupled with the Network System. An Ultra Wide Band Generator (180 kV, 700 MHz) was used as the IEMI source. The EUTs are the Switch Hub and Workstation, which are used to configure the network system. The network system was monitored through the LAN system configuration, to confirm a malfunction of the network device. The results of the experiment indicate that a malfunction of the network occurs as the electric field increases. The data loss rate increases proportionally with increasing radiating time. In the case of the Switch Hub, the threshold electric field value was 10 kV/m for all conditions used in this experiment. The threshold point causing malfunction was influenced only by the electric field value. The correlation between the threshold point and pulse repetition rate was not found. However, in case of the Workstation, it was found that as the pulse repetition rate increases, the equipment responds weakly and the threshold value decreases. To verify the electrical coupling of the EUT by IEMI, current sensors were used to measure the PCB line inside the EUT and network line coupling current. As a result of the measurement, it can be inferred that when the coupling current due to IEMI exceeds the threshold value, it flows through the internal equipment line, causing a malfunction and subsequent failure. The results of this study can be applied to basic data for equipment protection, and effect analysis of intentional electromagnetic interference.