• Title/Summary/Keyword: Repeated measurement data

Search Result 222, Processing Time 0.028 seconds

The Development of an Oral Care Protocol for Cancer Patients Receiving Chemotherapy and its Effects (항암화학요법을 받는 환자의 구강관리 프로토콜개발 및 적용효과)

  • Son, You Jin;Shin, Yoon Jung;Cho, Mee Young;Kim, Soon Ho;Park, Ok Sun;Han, Soo Young;Kang, Young Lynn;Kim, Yeon Woo;Song, Su Kyung;Lee, Sun Hwa;Hwang, In Hee;Son, Byung Hee;Joo, Un Hye;Kim, Sue;Choi, Hye Jin
    • Journal of Korean Clinical Nursing Research
    • /
    • v.17 no.1
    • /
    • pp.113-122
    • /
    • 2011
  • Purpose: This study was conducted to develop and evaluate an oral care protocol for cancer patients receiving chemotherapy. Methods: The participants in this study were cancer patients in Severance hospital in Seoul. A total of 31 patients were assigned to the experimental group, and 29 patients to the control group. Data were collected from August 1 to October 5, 2010. The protocol included definition and symptom of oral mucositis, self-check method of oral status, prophylactic method of oral mucositis (oral care, eating habits, and gargling) and management of oral mucositis. Oral Assessment Guide (OAG) was used as the measurement tool of oral mucositis in this study, Oral Care Performance Scale was used as the measurement tool of oral care performance status. Data were analyzed with a $x^2-test$ and t-test, and repeated measures ANOVA, using SPSS/WIN 18.0 program. Results: Patients in the experimental group receiving the oral care protocol had a significant difference (t=-2.938, p=.005) in the oral care performance compared to the control group. However, there was no significant difference (F=1.255, p=.274) in the oral mucositis status between two groups. Conclusion: This study showed that the oral care protocol could improve oral care performance status for the patients under chemotherapy.

Development of Personalized Exercise Prescription System based on Kinect Sensor (Kinect Sensor 기반의 개인 맞춤형 운동 처방 시스템 개발)

  • Woo, Hyun-Ji;Yu, Mi;Hong, Chul-Un;Kwon, Tae-Kyu
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.3
    • /
    • pp.593-605
    • /
    • 2022
  • The purpose of this study is to investigate the personalized treacmill exercise analysis using a smart mirror based on Kinect sensor. To evaluate the performance of the development system, 10 health males were used to measure the range of the hip joint, knee joint, and ankle joint using a smart mirror when walking on a treadmill. For the validity and reliability of the development system, the validity and reliability were analyzed by comparing the human movement data measured by the Kinect sensor with the human movement data measured by the infrared motion capture device. As a result of validity verification, the correlation coefficient r=0.871~0.919 showed a high positive correlation, and through linear regression analysis, the validity of the smart mirror system was 88%. Reliability verification was conducted by ICC analysis. As a result of reliability verification, the correlation coefficient r=0.743~0.916 showed high correlation between subjects, and the consistency for repeated measurement was also very high at ICC=0.937. In conclusion, despite the disadvantage that Kinect sensor is less accurate than the motion capture system, Kinect is it has the advantage of low price and real-time information feedback. This means that the Kinect sensor is likely to be used as a tool for evaluating exercise prescription through human motion measurement and analysis.

Changes of Surface Temperature and Electromyography Activities by Local Heat and Cold (온열과 냉의 국소적용에 의한 체표면 온도와 근전도 활동의 변화)

  • Choi, Seok-Ju;Lim, Sang-Wan;Kim, Su-Hyon;Mun, Dal-Ju
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.5 no.2
    • /
    • pp.61-72
    • /
    • 2007
  • INTRODUCTION: Local heat and cold application has been frequently used as means of muscle relaxation and blood circulation or reinforcing muscle strength, relaxing muscle tension in clinical situation. In particular, it has been known that long-term heat and cold application for relaxing muscle tension inhibits muscle spasticity or tension. But, it has been rarely reported that what influences of heat and cold application on activation of muscle action potential. Therefore, this study aims to analyze surface temperature and electromyography activities according to the heat and cold application. METHODE: Subjects of this research were 10 normal men and women (5 men, 5 women). Hot pack and cold pack was applied to vastus medialis muscle of thigh and rectus femoris muscle for 20 min. Surface temperature of vastus medialis muscle and rectus femoris muscle was measured, knee joint of subjects was in $45^{\circ}$ flexion, sitting on a chair, maximal isometric contraction was induced, surface electromyography (sEMG) signals were collected and root mean square (RMS) and median frequency (MOF) were analyzed. All measurements were conducted before and immediately after experiment, 10 min., 20 min. and 30 min. after experiment. Data were analyzed with SPSS 12.0 program, comparison of changes in superficial temperature and sEMG signals through repeated measurement was conducted with repeated measures ANOVA and significance level $\alpha$ was 0.05. RESULTS: Changes of surface temperature of vastus medialis muscle according to cold application were radically decreased immediately after application, but it was recovered after 30 min. of application and it showed significant difference (F4. 36=72.216, P<0.001). Surface temperature of rectus femoris also showed radical decrease immediately after application, but it was recovered after 30 min. of application and showed significant difference (F4. 36=88.930, P<0.001). Changes of surface temperature of vastus medialis muscle according to heat application were radically increased immediately after application, but it was recovered after 30 min. of application and it showed significant difference (F4. 36=27.267, P<0.001). Surface temperature of rectus femoris also showed radical decrease immediately after application, but it was recovered after 30 min. of application and showed significant difference (F4. 36=19.774, P<0.001). Changes of sEMG by heat and cold application were no statistical difference. Surface temperature of skeletal muscle after heat and cold application showed significant change for 30 min., but it was found that increase or decrease of surface temperature had not great influence on sEMG activities.

  • PDF

EFFECT OF VARIOUS LINERS ON THE POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN (수종의 이장재가 복합레진의 중합수축에 미치는 영향)

  • Choi, Ji-Won;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.606-614
    • /
    • 2006
  • The purpose of this study was to evaluate the polymerization contraction of composite resin(Tetric $ceram^{(R)}$, Ivoclar Vivadent Liechtenstein) according to various liners(Tetric $flow^{(R)}$, Ivoclar Vivadent, Liechtenstein/$Ionosit^{(R)}$, DMG, German/ $Vitrebond,^{TM}$ 3M-ESPE, USA). The strain gauge method was used for measurement of polymerization shrinkage strain. Specimens were divided by 8 groups according to curing units and liners. Group A, E: Tetric $ceram^{(R)}$ bulk filing, Group B, F: Tetric $flow^{(R)}$ lining, Tetric $ceram^{(R)}$ filling, Group C, G: $Ionosit^{(R)}$ lining, Tetric $ceram^{(R)}$ filling, Group D, H: $Vitrebond^{TM}$ lining, Tetric $ceram^{(R)}$ filling. Group A, B, C and D were cured using the conventional halogen light($XL3000^{TM}$ 3M ESPE, USA) for 40 seconds at $400mW/cm^2$. Group E, F G and H were cured using light emitted diode(LED) light(Elipar Freelight $2^{TM}$, 3M-ESPE, USA) for 15 seconds at 800 $mW/cm^2$. Strain gauge attached to each sample was connected to a strainmeter. Measurements were recorded at each second for the total of 750 seconds including the periods of light application. Obtained data were analyzed statistically using Repeated measures ANOVA and Tukey test. The results of this were as follows : 1. Contraction stresses in flowable resin and glass ionomer lining group were lower than that in compomer lining group(p<0.05). 2, Contraction stresses in LED curing light groups were higher than that in halogen curing light groups, but there was no significant difference (p>0.05).

  • PDF

A Study of Arrow Performance using Artificial Neural Network (Artificial Neural Network를 이용한 화살 성능에 대한 연구)

  • Jeong, Yeongsang;Kim, Sungshin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.5
    • /
    • pp.548-553
    • /
    • 2014
  • In order to evaluate the performance of arrow that manufactures through production process, it is used that personal experiences such as hunters who have been using bow and arrow for a long time, technicians who produces leisure and sports equipment, and experts related with this industries. Also, the intensity of arrow's impact point which obtains from repeated shooting experiments is an important indicator for evaluating the performance of arrow. There are some ongoing researches for evaluating performance of arrow using intensity of the arrow's impact point and the arrow's flying image that obtained from high-speed camera. However, the research that deals with mutual relation between distribution of the arrow's impact point and characteristics of the arrow (length, weight, spine, overlap, straightness) is not enough. Therefore, this paper suggests both the system that could describes the distribution of the arrow's impact point into numerical representation and the correlation model between characteristics of arrow and impact points. The inputs of the model are characteristics of arrow (spine, straightness). And the output is MAD (mean absolute distance) of triangular shaped coordinates that could be obtained from 3 times repeated shooting by changing knock degree 120. The input-output data is collected for learning the correlation model, and ANN (artificial neural network) is used for implementing the model.

Assessment of Validity and Reliability of Plantar Pressure in Smart Insole (스마트 인솔의 족저압 측정 결과에 대한 타당도 및 신뢰도 평가)

  • Kang, Ho Won;An, Yae Lynn;Kim, Dae-Yoo;Lee, Dong-Oh;Park, Gil Young;Lee, Dong Yeon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.26 no.3
    • /
    • pp.130-135
    • /
    • 2022
  • Purpose: Smart insoles are wearable devices that are inserted into shoes. Smart insoles with built-in pressure and acceleration sensors can measure the plantar pressure, stride length, and walking speed. This study evaluated the validity and reliability of the plantar pressure measurements of smart insoles during walking on flat ground. Materials and Methods: Twenty one subjects were included in this study. After wearing smart insoles, I-SOL® (Gilon, Seongnam, Korea), the subjects walked a 10 m corridor six times at a rate of 100 steps/min, and the middle three steps, free from direction changes, were chosen for data analysis. The same protocol was repeated after wearing Pedar-X (Novel Corporation, Munich, Germany), an insoletype plantar pressure measurement equipment with proven validity. The average maximum pressure (Ppeak, kPa) and the time at which Ppeak appeared (Ptime, %stride) were calculated for each device. The validity of smart insoles was evaluated by using the interclass correlation coefficient (ICC) of Ppeak and Ptime between the two instruments, and Cronbach's alpha was obtained from the Ppeak values to evaluate the reliability. Results: The ICC of Ppeak was 0.651 (good) in the hallux, 0.744 (good) in the medial forefoot, 0.839 (excellent) in the lateral forefoot, and 0.854 (excellent) in the hindfoot. The ICC of Ptime showed 0.868 (excellent) in the hallux, 0.892 (excellent) in the medial forefoot, 0.721 (good) in the lateral forefoot, and 0.832 (excellent) in the hindfoot. All ICC values showed good or excellent results. The Cronbach's alpha of Ppeak measured in the smart insoles was 0.990 in the hallux, 0.961 in the medial forefoot, 0.973 in the lateral forefoot, and 0.995 in the hindfoot; all indicated excellent reliability in all areas. Conclusion: The plantar pressure measurements of smart insoles during walking on a flat ground showed validity compared to Pedar-X, and high reliability after repeated measurements.

Effect of Home Training on Male College Students Body Composition and Fitness (홈트레이닝이 남자 대학생의 신체 조성과 체력에 미치는 효과)

  • Han Jun Hee;Jae Hoon Lee;Ji Sun Kim;Yoo Sung Oh
    • Journal of the Korean Applied Science and Technology
    • /
    • v.41 no.2
    • /
    • pp.413-423
    • /
    • 2024
  • Sixteen male college students were divided into two groups: a face-to-face group(n=8) and a real-time non-face-to-face exercise group(n=8), engaging in 30minute sessions twice a week for a duration of 8 weeks. Body composition and physical strength were measured as dependent variables before and after the home training period. For data analysis, a two-way ANOVA with repeated measures was conducted to evaluate the effects on body composition and physical strength, considering differences in exercise methods and measurement periods. Post hoc analysis using Bonferroni correction was applied. To compare the mean difference in change between groups, the pre-post difference was calculated, and an independent t-test was performed. The statistical significance level was set at p<.05. The results showed that 8 weeks of home training led to an increase in skeletal muscle mass and improvements in muscle strength, muscular endurance, and cardiorespiratory endurance in male college students, regardless of whether they participated in face-to-face or real-time non-face-to-face exercise. Moreover, there was no significant difference in exercise effectiveness between the face-to-face and real-time non-face-to-face exercise methods. Thus, these findings suggest that real-time non-face-to-face exercise can be as effective as face-to-face exercise in enhancing skeletal muscles and physical strength in male college students. Additionally, if a real-time non-face-to-face exercise program is validated for individuals with mobility issues or the elderly, it could serve as an effective alternative for those who face challenges in participating in face-to-face exercise sessions.

Enhancing the Reliability of Coating Flaw Detection for Pipes Buried in Soil Using a Multi-Electrode Detector (다전극 탐상을 통한 토중 매설배관 피복결함 탐상 정확도의 개선)

  • Kim, M.G.;Lim, B.T.;Kim, K.T.;Chang, H.Y.;Park, H.B.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.265-280
    • /
    • 2020
  • External corrosion of buried pipes can be controlled using both coating and cathodic protection. However, deterioration of the coating can occur due to several reasons. The detection reliabilty of coating flaw detection methods is affected by interference such as metal objects connected to rectifiers and copper grids. When performing parallel direct current voltage gradient (DCVG) inspection, a sine wave form without potential reversal in voltage gradient appears in the area where the interference exists. However, this area may be not identified using existing methods. The objective of this study was to determine the effect of analyzing direction on the reliability of coating flaw detection of pipes buried in soil using a multi-electrode detector. DCVG on the buried pipe was measured along the buried pipe. This measurement parallel to the pipe was repeated. Measured data were analyzed for parallel, vertical, and diagonal directions. The reliability of coating flaw detection was improved by up to 46.4% compared to the conventional method.

The Effect of Problem Solving Group Counseling on the Index of Obesity and Health Habits of Obese Children (문제해결 상담프로그램이 아동의 비만지수와 건강습관에 미치는 영향)

  • Cho Mee-Young;Lee Hae-Jung;Lee Hwa-Ja;Park Hyoung-Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.34 no.7
    • /
    • pp.1224-1233
    • /
    • 2004
  • Purpose: This study was to investigate the effects of problem solving group counseling on the index of obesity and health habits for obese children. Method: Forty seven obese children participated in the study(Exp.=22, Cont.=25). Children were recruited from the forth and fifth grade with higher than $20\%$ of the obesity degree. The problem solving counseling lasted for 10 weeks. In order to evaluate the effects of counseling, physical characteristics and health habits were measured three times; pretest, posttest, and at 10 weeks follow-up. The obtained data was analyzed by $x^2-test$, t-test, and repeated measures ANOVA, using the SPSS WIN 10.0program. Result: Problem solving group counseling was effective on the physical characteristics(BMI, obesity degree, body fat ratio, waist measurement) and health habits over time. Children in the experimental group controlled their body weight better and reported lower scores in the index of obesity than children in the control group at 10 weeks follow-up. Conclusion: This counseling program helped obese children modify their health habits so that they could decrease their scores in the obesity index. It can be concluded that problem-solving counseling enhanced problem-solving abilities of obese children, which could help modify their ordinary health habits.

Evaluation of the accuracy of linear and angular measurements on panoramic radiographs taken at different positions

  • Nikneshan, Sima;Sharafi, Mohamad;Emadi, Naghmeh
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.191-196
    • /
    • 2013
  • Purpose: This study assessed the accuracy of linear and angular measurements on panoramic radiographs taken at different positions in vitro. Materials and Methods: Two acrylic models were fabricated from a cast with normal occlusion. Straight and $75^{\circ}$ mesially and lingually angulated pins were placed, and standardized panoramic radiographs were taken at standard position, at an $8^{\circ}$ downward tilt of the occlusal plane compared to the standard position, at an $8^{\circ}$ upward tilt of the anterior occlusal plane, and at a $10^{\circ}$ downward tilt of the right and left sides of the model. On the radiographs, the length of the pins above (crown) and below (root) the occlusal plane, total pin length, crown-to-root ratio, and angulation of pins relative to the occlusal plane were calculated. The data were subjected to repeated measures ANOVA and LSD multiple comparisons tests. Results: Significant differences were noted between the radiographic measurements and true values in different positions on both models with linear (P<0.001) and those with angulated pins (P<0.005). No statistically significant differences were observed between the angular measurements and baselines of the natural head posture at different positions for the linear and angulated pins. Conclusion: Angular measurements on panoramic radiographs were sufficiently accurate and changes in the position of the occlusal plane equal to or less than $10^{\circ}$ had no significant effect on them. Some variations could exist in the pin positioning (head positioning), and they were tolerable while taking panoramic radiographs. Linear measurements showed the least errors in the standard position and $8^{\circ}$ upward tilt of the anterior part of the occlusal plane compared to other positions.