• 제목/요약/키워드: Repeated failure

검색결과 321건 처리시간 0.028초

강판콘크리트 구조 이질접합부의 면외 휨/면내 전단하중 특성에 관한 실험연구 (An Experimental Study on Flexural/Shear Load Properties of SC(Steel Plate Concrete) Structure with Reinforced Concrete Joint)

  • 이경진;황경민;함경원;김우범
    • 한국강구조학회 논문집
    • /
    • 제24권2호
    • /
    • pp.137-147
    • /
    • 2012
  • 본 연구는 L형, I형 실험체에 강판 콘크리트 구조와 철근콘크리트 구조를 적용하여 이질접합부를 만들고, 실험체에 반복하중을 파괴 시 까지 가력하여 면외 휨 내력 및 면내 전단 내력을 평가하고 구조특성을 검토하기 위해서 실험연구를 수행하였다.본 연구에서 면외 휨 성능실험은 접합부에서 정착부 수직철근이 인발되면서 파괴되었고, 면내 전단성능실험은 기초부에서의 휨 균열이 발생하여 파괴되었으며, 이론식과의 비교결과 최대 내력이 실험값/이론값의 결과가 면외 휨성능실험은 96%, 면내 전단성능실험은 82%의 값을 나타내었다.

기관지내시경을 통해 치료한 활성탄 흡인 1예 (A Case of Activated Charcoal Aspiration Treated by Early and Repeated Bronchoalveolar Lavage)

  • 이한민;박재석;김재연;이지연;안병규;길효욱;최재성
    • Tuberculosis and Respiratory Diseases
    • /
    • 제72권2호
    • /
    • pp.177-181
    • /
    • 2012
  • Activated charcoal is an inert substance and it is used in standard therapy in patients with acute intoxication. Charcoal has some side effects such as pulmonary aspiration, gastrointestinal complications, and electrolyte abnormalities. Although aspiration of charcoal is a rare complication, it can cause fatal sequelae. We report a 69-year old man who developed acute respiratory failure associated with charcoal aspiration after management of glyphosate poisoning. The patient was drowsy and suffered severe vomiting during transport to our hospital. On arrival, acute respiratory failure was observed due to charcoal aspiration, but the clinical state was improved with repeated bronchoscopy with a bronchoalveolar lavage (BAL). We presumed that the aspirated charcoal was an important factor in evoking a lung injury. Early bronchoscopy with a BAL might be an effective method for eliminating charcoal from the lung, especially in the case of a large amount of aspiration, and be helpful in decreasing respiratory failure due to charcoal aspiration.

고장력볼트의 인장피로강도에 관한 실험적 연구 (Experimental Study on Tensile Fatigue Strength of the High Strength Bolts)

  • 한종욱;박영석
    • 대한토목학회논문집
    • /
    • 제28권2A호
    • /
    • pp.165-170
    • /
    • 2008
  • 각국의 강구조물 시공현장에서 사용되고 있는 고장력볼트의 인장강도는 일반적으로 1,000 MPa급이 주종을 이루고 있으나, 고강도강과 극후판의 개발과 교량 지간의 장대화로 인하여 강도가 큰 새로운 볼트 개발이 요구되고 있다. 한편, 반복적인 하중이 작용하는 곳에서 인장연결부에 사용되는 고장력볼트에 인장피로파괴 사례가 발생되고 있으나 아직까지 우리나라에서는 이에 대한 이론 및 실험적인 연구가 없는 실정이다. 따라서, 본 연구에서는 현재 일반적으로 사용하고 있는 F8T, F10T볼트와 새로이 개발된 F13T, F13T-N볼트에 대해서 인장피로실험을 수행하였다. 고장력볼트에 대한 피로강도평가는 반복횟수 200만회에 95% 하한신뢰도분석을 하여 수행하였고, 이를 기초로 3가지의 피로강도 기준안을 제시하였다. 또한, KS나사형상의 볼트와 새로이 제안된 나사선 형상의 볼트에 대한 피로강도에 대해서 비교 검토하였다.

Transition nuclear protein 1 as a novel biomarker in patients with fertilization failure

  • Jamileh Sadat Mirsanei;Hadis Gholipour;Zahra Zandieh;Masoumeh Golestan Jahromi;Mojgan Javedani Masroor;Mehdi Mehdizadeh;Fatemehsadat Amjadi
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제50권3호
    • /
    • pp.185-191
    • /
    • 2023
  • Objective: Although intracytoplasmic sperm injection (ICSI) is a way to deal with in vitro fertilization failure, 3% of couples still experience repeated fertilization failure after attempted ICSI, despite having sperm within normal parameters. These patients are a challenging group whose sperm cannot fertilize the egg during ICSI. Unfortunately, no test can predict the risk of fertilization failure. Phospholipase C zeta (PLCζ) and transition nuclear proteins (TNPs) are essential factors for chromatin packaging during sperm maturation. This study aimed to assess PLCζ1 and TNP1 expression in the sperm of patients with fertilization failure and the correlations among the DNA fragmentation index, PLCζ1 and TNP1 gene and protein expression, and the risk of fertilization failure. Methods: In this study, 12 infertile couples with low fertilization rates (<25%) and complete failure of fertilization in their prior ICSI cycles despite normal sperm parameters were chosen as the case group. Fifteen individuals who underwent ICSI for the first time served as the control group. After sperm analysis and DNA fragmentation assays, quantitative reverse-transcription polymerase chain reaction (qRT-PCR) and Western blot analyses were performed to compare the gene and protein expression of PLCζ and TNP1 in both groups. Results: DNA fragmentation was significantly higher in the fertilization failure group. The qRT-PCR and Western blot results demonstrated significantly lower PLCζ and TNP1 gene and protein expression in these patients than in controls. Conclusion: The present study showed that fertilization failure in normozoospermic men was probably due to deficient DNA packaging and expression of TNP1.

반복 하중 후 골밀도 감소에 따른 척추경 나사못의 고정력(Pullout Strength)감소 형태 분석 (Biomechanical analysis of pullout strength of the pedicle screws in relation to change bone mineral density)

  • 정덕영;이성재;김동수;신정욱;김원중;석세일
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.155-156
    • /
    • 1998
  • Screw loosening and subsequent pullout can be attributed to the reduction in bone mineral density in the vertebrae manifested by osteoporosis in which the decrease in fixation strength between the cancellous bone and screw threads are accelerated by repeated loads exerted by patients own weight and activities following the surgery. In this study, the change in pullout strength of the pedicle screws was investigated before and after repeated loads were imparted. For this purpose. Diapason pedicle screws $(6.7\times40mm)$ were inserted onto fresh porcine spine specimens (T1-L5) after bone mineral density was measured using a DEXA. With an MTS, an axial load was applied at a loading rate of 0.33mm/sec until failure to measure the maximum pullout strength. Flexion moment of 7.5N-m was then imparted at 0.5Hz for 2000 cycles. It was found that the maximum pullout strength was exponentially related to BMD regardless of load types ($107.71\;\times\;\exp^{(1.43{\times}BMD)}r^2=0.93$, P<0.0001 without repeated load; ($107.71\;\times\;\exp^{(2.19{\times}BMD)}r^2=0.78$, P<0.0001 with repeated load). The results suggest that the reduction in pullout strength for pedicle screws is far more prominent in osteoporotic spine than in normal spine especially as number of repeated load was increased. More importantly, it was demonstrated that the level of bone mineral density and the activity level of the patient should be evaluated in more detail for successful implementation of pedicle screw systems in spinal surgery.

  • PDF

Development of an evaluation method for nuclear fuel debris-filtering performance

  • Park, Joon-Kyoo;Lee, Seong-Ki;Kim, Jae-Hoon
    • Nuclear Engineering and Technology
    • /
    • 제50권5호
    • /
    • pp.738-744
    • /
    • 2018
  • Fuel failure due to debris is a major cause of failure in pressurized water reactors. Fuel vendors have developed various filtering devices to reduce debris-induced failure and have evaluated filtering performance with their own test facilities and methods. Because of the different test facilities and methods, it is difficult to compare filtering performances objectively. This study presents an improved filtering test and an efficiency calculation method to fairly compare fuel-filtering efficiency regardless of the vendor's filtering features. To enhance the reliability of our evaluation, we established requirements for the test method and had a facility constructed according to the requirements. This article describes the debris specimens, the amount of debris, and the replicates for the proposed test method. A calculation method of comprehensive debris-filtering efficiency using a weighted mean is proposed. The test method was verified by repeated tests, and the tests were carried out using the PLUS7 and 17ACE7 test fuels to calculate the comprehensive debris-filtering efficiencies. The evaluation results revealed that the filtering performance of PLUS7 is better than that of 17ACE7. The proposed method can be used on any kind of debris-filtering devices and is appropriate for use as a standard.

플로우포밍 스플릿 공정 시 맨드릴의 응력 해석을 통한 파손 원인 분석 (A Study on Failure Analysis of Mandrel in the Flow Forming Split Process through Stress Analysis)

  • 원권희;홍승우;박희수;이상철;홍성진;현승균;김상열
    • 소성∙가공
    • /
    • 제31권6호
    • /
    • pp.384-393
    • /
    • 2022
  • The flow forming process consists of a split process, a divide process, and a forming process. The split process is a forming process in which rollers radially permeate a simple disc-shaped forging material and split it in both directions to form a top-bottom bidirectional cup. It is advantageous for post-processing to deepen the forming depth in the split process but this characteristic causes the failure near the edge of the mandrel during the actual process. The split process was analyzed using Rigid Plastic FEM, and the stress analysis of the mandrel was conducted to find the cause of the failure. It was found that the failure occurred due to fatigue accumulation damage caused by repeated residual stress.

청소년의 금연경험 탐색 (Experience of Adolescents Smoking Cessation : Use of Focus Group interview)

  • 한영란
    • Child Health Nursing Research
    • /
    • 제11권1호
    • /
    • pp.23-33
    • /
    • 2005
  • Purpose: The purpose of this study was to identify the experience of smoking cessation in middle and high school students who smoked or were ex-smokers. Method: Data were collected through focus group interviews with 3 groups (15 students), and were analyzed according to the analytic method of Morgan (1998) and Krueger (1998). Results: Six categories were identified. They included reasons to quit smoking, efforts to maintain smoking cessation, lures to start smoking again, improved self-esteem after overcome temptations, frustration following repeated failures in attempts to quit smoking and suggestions to help maintain smoking cessation. Through these results, it was found that reasons for quitting smoking were different from those of adults, strategies to maintain smoking cessation were limited and repeated failure in attempts to quit smoking led students to give up attempting to quit smoking. Conclusion: A high percentage of adolescent smokers want to quit but are unsuccessful in doing so. Considering the results of our analysis, smoking cessation programs and strategies should be carefully developed to be more effective in help adolescents quit smoking and maintain smoking cessation.

  • PDF

표면거칠기와 유한요소법을 이용한 터빈 블레이드의 파손해석에 관한 연구 (A Study on Failure Analysis of Turbine Blade Using Surface Roughness and FEM)

  • 홍순혁;이동우;이선봉;조석수;주원식
    • 한국자동차공학회논문집
    • /
    • 제9권6호
    • /
    • pp.170-177
    • /
    • 2001
  • Turbine blade is subject to torsional load by torsion-mount, centrifugal load by rotation of rotor and repeated bending load by steam pressure. Turbine with partially cracked blade has normal working condition at initial repair time but vibratory working condition at middle repair time due to crack growth. Finite element analysis on turbine blade indicates that repeated bending load out of all loads is the most important factor on fatigue strength of turbine blade. Therefore, this study shows root mean square roughness has linear relation with stress intensity factor range in 12% Cr steel and can predict loading condition of fractured turbine blade.

  • PDF

Surface Damage Accumulation in Alumina under the Repeated Normal-Tangential Contact Forces

  • Lee, Kwon-Yong;Choi, Sung-Jong;Youn, Ja-Woong
    • KSTLE International Journal
    • /
    • 제1권1호
    • /
    • pp.48-51
    • /
    • 2000
  • Surface damage accumulation of alumina ceramics under the cyclic stress state was analyzed. The alternating stress state in repeat pass sliding contact was simulated by a synchronized biaxial (normal and tangential) repeated indentation technique. Wear debris formation mechanism through damage accumulation and fatigue grain failure in both alumina ceramic balls and flat disks was confirmed, and the contact induced surface degradation due to fatigue cracking accumulation was quantified by measuring vertical contact displacement. Variation of structural compliance (slope of load-displacement curve) of two contacting bodies was expressed as a variation of the apparent elastic property, called pseudo-elastic constant, of the contact system.

  • PDF