• 제목/요약/키워드: Repeated Measurement Stability

검색결과 36건 처리시간 0.028초

반복 측정이 가능한 인라인 측정시스템의 안정성 평가 (Stability Evaluation of In-Line Measurement System with Repeated Measurements)

  • 정수호;변재현
    • 대한산업공학회지
    • /
    • 제30권1호
    • /
    • pp.36-43
    • /
    • 2004
  • In-line measurement systems are preferred to those in analytical laboratories, since in-line systems provide rapid response to process upsets. If an in-line measurement system exhibits an unstable variation and if this instability in measurement variation goes undetected, it will make the process monitoring procedure invalid. This paper presents a stability evaluation procedure for the in-line measurement system using two independent readings from the in-line measurement system and one reading from the analytical laboratory, which requires less measurement cost and time.

수종의 치과용 스캐너로 채득된 3차원 치아 모형의 반복측정 안정성 평가 연구 (A Study on the Evaluation of Repeated Measurement Stability of 3D Tooth Model Obtained by Several Dental Scanners)

  • 배은정;김원수;임중연
    • 한국콘텐츠학회논문지
    • /
    • 제21권5호
    • /
    • pp.996-1003
    • /
    • 2021
  • 연구의 목적은 치과용 스캐너의 반복측정 안정성 비교를 통해 영향을 미치는 스캐너의 요소를 평가하는 것이다. 연구 목적을 달성하고자 청색광을 사용하는 I사의 스캐너와 광학 방식을 사용하는 Z사의 스캐너 그리고 백색광을 사용하는 D사의 스캐너를 본 연구의 반복측정 안정성 연구에 사용하였다. 측정 결과는 root mean square (RMS)로 계산하였고 one-way ANOVA 통계기법을 적용하여 유의수준을 확인하였다(𝛼=.05). 통계분석 결과 가장 큰 RMS 값을 가지는 스캐너는 Z-opt 그룹으로 38.2 ㎛이었다. 다음으로는 D-white가 35.2 ㎛로 나타났고, 가장 RMS 값이 적은 그룹은 I-blue 그룹으로 34.1 ㎛이었다. 각 그룹간에 RMS 평균을 비교한 결과는 유의하지 않은 것으로 나타났다(p>.05). 이 결과로부터 청색광, 백색광 그리고 광학 방식의 스캐너에서는 반복측정 안정성에서 청색광의 오차가 가장 낮은 것으로 나타났으나 통계적 유의성은 없었다. 연구결과 임상적 허용 가능하다는 것이 본 연구의 결론이다.

전방머리자세 대상자에게 어깨관절 멀리건테이핑 적용이 손목굽힘근의 근활성도와 파악력에 미치는 영향 (The Effects of Shoulder Mulligan Taping and Repeated Measurements on Wrist Flexor Muscle Activity and Grip Strength in Forward Head Posture)

  • 오강오;박수형;김동우;백용현;최수홍
    • 대한정형도수물리치료학회지
    • /
    • 제24권2호
    • /
    • pp.1-7
    • /
    • 2018
  • Background: This study was carried out to investigate the effect of mulligan taping group and repeated measurement group on muscle activity and grip strength of adult with forward head posture. Methods: Thirty adults with forward head posture were randomly assigned to each of 15 mulligan taping and repeat measurement groups. The mulligan taping group measured the pre-test and post-test muscle activity and the grip strength three times and compared the mean values. The repeat group was repeatedly measured and measured before and after the experiment, The collected data were analyzed using SPSS statistical program. Results: There was no significant difference between mulligan taping group and repeated measurement group in changes of muscle activity. There was a significant difference between mulligan taping group and repeated measurement group in changes of grip strength. Conclusions: Mulligan taping was applied to an adult with forward head posture, there was no significant change in muscle activity of flexor carpi radialis and palmaris longus, but it seems to improve hand function by re-aligned of nearby muscles by maintaining scapular stability.

상악 전치의 치열 형태에 따른 스캔 반복 측정 안정성 평가: in vitro 연구 (Evaluation of repeated measurement stability of dentition type of maxillary anterior tooth: an in vitro study)

  • 박동인;손호정;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제41권3호
    • /
    • pp.211-217
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the repeated measurement stability of scans related to dentition type. Methods: A normal model and the crowding and diastema models are also duplicated using duplicating silicon. After that, a plaster model is made using a plaster-type plaster on the duplicate mold, and each model is scanned 5 times by using an extraoral scanner. The gingival part and molar part were deleted from the 3D STL file data obtained through scanning. Using the 3D stl file obtained in this way, data is nested between model groups. Thereafter, RMS values obtained were compared and evaluated. The normality test of the data was performed for the statistical application of repeated measurements with dentition type, and the normality was satisfied. Therefore, the one-way ANOVA test, which is a parametric statistical method, was applied, and post-tests were processed by the Scheffe method. Results: The average size of each RMS in the Normal, Diastema, and Crowding groups was Normal> Crowding> Diastema. However, the standard deviation was in the order of Crowding> Normal> Diastema. The average value of each data is as follows. Diastema model was the smallest ($5.51{\pm}0.55{\mu}m$), followed by the crowding model ($12.30{\pm}2.50{\mu}m$). The normal model showed the maximum error ($13.23{\pm}1.06{\mu}m$). Conclusion: There was a statistically significant difference in the repeatability of the scanning measurements according to the dentition type. Therefore, you should be more careful when scanning the normal intense or crowded dentition than scanning the interdental lining. However, this error value was within the range of applicable errors for all clinical cases.

산업용 센서에 사용하는 Teflon계 박막 일렉트렛의 내열성 향상에 관한 연구 (A Study on the Way to Increase Heat Resistance of Teflon Type Thin Film Electret Applied for Industrial Sensor)

  • 김병수;이덕출
    • 한국안전학회지
    • /
    • 제18권3호
    • /
    • pp.60-63
    • /
    • 2003
  • For the increase the charge stability of teflon electrets for used at uncomfortable industrial circumstances with high temperature or humidity, We made an investigation into double layer effect of teflon electrets. Teflon AF film was spincoated on FEP film and then the charge storage property of AF/FEP dual film was investigated to be compared with FEP film. It was found that the AF/FEP dual film has higher surface potential than FEP film on the repeated charging and annealing process. It seems that AF/FEP dual film has higher thermal stability than FEP film through TSC measurement. If the investigations of the double layer effect of Teflon film carried out more closely with it's molecular structures and surface conditions, it may be effectively improved the stability of charge storage.

Analysis of Stability on Single-leg Standing by Wearing a Head Mounted Display

  • Woo, Byung Hoon
    • 한국운동역학회지
    • /
    • 제27권2호
    • /
    • pp.149-155
    • /
    • 2017
  • Objective: The purpose of this study was to investigate the effects of three visual conditions (eyes opened, eyes closed, and wearing of a head mounted display [HMD]) on single-leg standing through kinematics and kinetic analysis. Method: Twelve college students (age: $24.5{\pm}2.6years$, height: $175.0{\pm}6.4cm$, weight: $69.2{\pm}5.1kg$) participated in this study. The study method adopted three-dimensional analysis with six cameras and ground reaction force measurement with one force plate. The analysis variables were coefficient of variation (CV) of the center of body mass, head movement, ground reaction force, and center of pressure, which were analyzed using one-way analysis of variance with repeated measures according to visual conditions. Results: In most cases, the results of this study showed that the CV was significantly higher in the order of HMD wearing, eyes closed, and eyes opened conditions. Conclusion: Our results indicated that body sway was the largest in the HMD wearing condition, and the risk of falling was high owing to the low stability.

무릎관절 멀리건 테이핑이 균형능력과 각근력에 미치는 효과와 측정의 반복에 의한 효과 비교 (Comparison of the Balancing Capacity and Strength of Taping for the Knee Joint and Repeated Measurements)

  • 박보현;최수홍;김성중;박수형;오강오
    • 대한정형도수물리치료학회지
    • /
    • 제24권2호
    • /
    • pp.9-15
    • /
    • 2018
  • Background: The purpose of this study was to compare the effects of mulligan taping on knee joints on balance ability and strength with repeated measurements. Methods: Seventeen patients were randomly assigned to the 8 taping group and the 9 repeat measurement group. To measure the balance ability, fall risk assessment equipment was used, and the measurement of the muscle strength was performed by using the equipment of the same company. Results: Balanced abilities and muscle strength were increased in groups with taping only after Mulligan taping. Conclusions: The application of mulligan taping did not have the effect of stimulating the inherent receptive sensation. However, active grouping of the knee joint taping only, and muscle strength and muscle strength were increased. It increases the stability and activity of the muscles that operate on the balance of the active knee joint and muscle strength, thereby enhancing exercise prevention and prevention performance and exercise performance.

고관절용 인공관절 시스템의 안정성 평가 (Stability Test of Artificial Joint for Hip Joint)

  • 석승휘;박수
    • 대한기계학회논문집A
    • /
    • 제36권9호
    • /
    • pp.1033-1039
    • /
    • 2012
  • 인공관절은 관절부의 뼈가 파괴되거나 관절 손상을 입어 관절로서의 기능을 할 수 없게 된 경우에 사용된다. 고관절용 인공관절 시스템의 일차안정성을 평가하기 위해서는 인공관절이 삽입된 직후 인공관절에 반복하중을 가하여 대퇴골과 인공관절 사이의 상대변위를 측정하게 된다. 이때, 정확한 안정성을 평가하기 위해서는 인공관절이 대퇴골을 파고드는 변위와 대퇴골에서 인공관절이 회전한 각의 변화량을 정확히 측정하여야 한다. 본 연구에서는 고관절용 인공관절 시스템의 일차안정성을 평가하기 위해 새로운 상대 변위측정 방식을 제안하고 이를 이용하여 수술 방법의 차이 및 대퇴골 자체 강성의 차이에 따른 일차 안정성을 사체에서 얻은 대퇴골 실험을 통해 비교 평가하였다.

PV모듈의 발전성능시험을 위한 Solar Simulator의 측정불확도 요인 분석 (Analysis of Solar Simulator's Uncertainty Factor for Maximum Output Power Test of Photovoltaic Module)

  • 강기환;김경수;박지홍;유권종;안형근;한득영
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.39-45
    • /
    • 2007
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.36W$ with 95% confidence level for 125W PV module(KD-5125).

PV모듈의 I-V특성 시험을 위한 Solar Simulator의 측정불확도 요인 분석 (Analysis of Solar Simulator's Uncertainty Factor for Photovoltaic Module's I-V curve test)

  • 강기환;박지홍;김경수;유권종;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.5-7
    • /
    • 2006
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.75W$ with 95% confidence level for 125W PV module.

  • PDF