• Title/Summary/Keyword: Repeated

Search Result 8,679, Processing Time 0.036 seconds

A Study on the Detergency and Functionality of Laminating Finished Fabrics for Outdoor Wear by Repeated Washing (아웃도어용 라미네이팅 가공 직물의 반복세척에 의한 세척성 및 기능성 연구)

  • Hyun, Su Jung;Lee, Jeong Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.3
    • /
    • pp.527-536
    • /
    • 2017
  • This study investigated the detergency and functionality of laminating finished fabrics for outdoor wear based on repeated washing. Laminating finished fabrics were selected as the main fabrics for outdoor wear and used as test fabrics. The effects of outdoor exclusive detergent and normal neutral detergent were examined according to washing time, temperature, rpm and detergent concentration based on the use of a Terg-O-Tometer. Re-soiling of the test fabrics was measured by Florio-Mersereau. Permeability, water repellency, water resistance and absorbency were estimated to measure improvements and effects in regards to outdoor exclusive detergent in optimal washing conditions. The detergent effect of outdoor exclusive detergent was superior compared to normal neutral detergent. Re-soiling was lower with exclusive outdoor detergent than with normal neutral detergent. The measurement of functionality for laminating finished fabrics before and after washing indicated that functionality was decreased with repeated washing.

Linear Trend Comparison of Repeated Measures Data among Treatments with a Control (반복측정 자료에서 개제기올기를 이용한 대존군과 처리군들의 선형추세 검정법)

  • Kwon, Jae-Hoon;Kim, Dong-Jae
    • Communications for Statistical Applications and Methods
    • /
    • v.16 no.6
    • /
    • pp.945-957
    • /
    • 2009
  • Repeated measurement data among several treatments with a control is often used in the field of medicine study. In this paper, we suggest a method for comparison of the linear trend of responds followed time among several treatments with a control based on repeated measurement data. First, we estimate slope from each subject and generate samples using the slope estimated previous. And then, we test the difference among treatment with a control by ANOVA F test, Jonckheere-Terpstra test, updated control group procedure using generated samples. Monte Carlo Simulation is adapted to compare the power and experimental significance levels in various configuration.

Neutralizing Effects of Antiserum by Repeated Subcutaneous Administration of Recombinant Human Growth Hormone (rhGH)

  • Song, Yeon-Jung;Park, Shin-Hye;Park, Seung-Kook;Yeon, Je-Deuk
    • Biomolecules & Therapeutics
    • /
    • v.10 no.3
    • /
    • pp.175-179
    • /
    • 2002
  • Human growth hormone (hGH) forms antibody by repeated administration. The present study investigated to confirm formation of antibody by repeated subcutaneous administration of hGH for two months in rats and dogs. In this result, hGH-injected sera were significantly higher than control sera by 1:1,000,000 of dilution factor. After antibody formed sera (anti-hGH sera) and control sera were added to 30 $\mu\textrm{g}$/ml hGR, the complex incubated for overnight at $30^{\circ}C$. Anti-hGH sera decreased hGH contents about 90% compared to control sera. Also, body weight gain conducted decreased about 67% compared to control sera in hypophysectomised rat. Inconclusion, repeated administration of hGH formed antibody because hGH was foreign protein to rats and dogs. And formed antibody of hGH was blocked and decreased many efficacy of hGH, the antibody was proved to be neutralizing antibody. Thus, because neutralizing antibodies were decreased pharmacological effects of hGH, administration more than two months were no significance.

Rutting Potential Evaluation of Asphalt Mixtures by Repeated-Load Creep Test (반복하중 크리프시험에 의한 아스팔트 혼합물의 소성변형특성 평가)

  • Zhu L.Y.;Fwa T.F.
    • International Journal of Highway Engineering
    • /
    • v.8 no.3 s.29
    • /
    • pp.21-28
    • /
    • 2006
  • Field or laboratory wheel tracking tests have been employed for the evaluation of the rutting potential of asphalt paving mixtures. Compared to field tests, laboratory wheel tracking tests are much less expensive and more manageable for most road projects. However, most test laboratories are not equipped to perform such tests because there does not exist any standard test procedure, and the required equipment is rather expensive. Futhermore, the size of test specimens and the relatively large quantity of test mixture required present difficulties for laboratory specimen mixing and compaction. This paper describes a project conducted to study the feasibility of replacing wheel tracking testsby a repeated-load creep test for rutting potential evaluation. Comparisons were made between the results of the two tests for different test temperatures, loading speeds and applied pressures. Three types of asphalt mixtures were studied in the test program. Favorable conclusions concerning the use of the repeated-load test for rutting potential evaluation were drawn based on the findings of the experimental test results. The correlation between the two types of tests was found to be good for all threeasphalt mixtures. Adopting the repeated-load creep test would lead to cost savings since it employs standard test equipment already available in most laboratories. It would also result in substantial time savings due to the much smaller quantity of mix needed, and the ease in specimen preparation.

  • PDF

Sample size calculation for comparing time-averaged responses in K-group repeated binary outcomes

  • Wang, Jijia;Zhang, Song;Ahn, Chul
    • Communications for Statistical Applications and Methods
    • /
    • v.25 no.3
    • /
    • pp.321-328
    • /
    • 2018
  • In clinical trials with repeated measurements, the time-averaged difference (TAD) may provide a more powerful evaluation of treatment efficacy than the rate of changes over time when the treatment effect has rapid onset and repeated measurements continue across an extended period after a maximum effect is achieved (Overall and Doyle, Controlled Clinical Trials, 15, 100-123, 1994). The sample size formula has been investigated by many researchers for the evaluation of TAD in two treatment groups. For the evaluation of TAD in multi-arm trials, Zhang and Ahn (Computational Statistics & Data Analysis, 58, 283-291, 2013) and Lou et al. (Communications in Statistics-Theory and Methods, 46, 11204-11213, 2017b) developed the sample size formulas for continuous outcomes and count outcomes, respectively. In this paper, we derive a sample size formula to evaluate the TAD of the repeated binary outcomes in multi-arm trials using the generalized estimating equation approach. This proposed sample size formula accounts for various correlation structures and missing patterns (including a mixture of independent missing and monotone missing patterns) that are frequently encountered by practitioners in clinical trials. We conduct simulation studies to assess the performance of the proposed sample size formula under a wide range of design parameters. The results show that the empirical powers and the empirical Type I errors are close to nominal levels. We illustrate our proposed method using a clinical trial example.

A VITRO STUDY OF RETAINED SCREW STABILITY BY VARIOUS CONNECTION DESIGNS BETWEEN FIXTURE AND ABUTMENT IN IMPLANT DENTISTRY (임플란트 고정체와 지대주 연결 형태의 차이에 따른 유지 나사 안정성에 대한 연구)

  • Yang Jae-Sik;Vang Mong-Sook;Jo Gyu-Jong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.83-93
    • /
    • 2004
  • Statement of problem : Since the concept of osseointegrated dental implant by $Br{\aa}nemark$ et al was first applied to mandibular full edentulous patients. Recently it is considerated the first treatment option on missing teeth. A common problem associated with dental implant restorations is loosening of screws that retain the prosthesis to the abutment and the abutment to the implant fixture. Purpose : This study is to examine the influence on screw loosening of implant-abutment designs. Material and methods : External hex, cone screw, beveled hex, cam cylinder, cylinder hex by means of evaluating the loosening torques, with respect to a range of tightening torques after repeated loading. Result : 1. Cone screw, beveled hex groups are the highest initial tightening rate and cylinder hex, external hex groups are the lowest initial tightening rate (p < 0.05). 2. Cone screw groups are the highest after repeated loading tightening rate and cylinder hex groups are lowest after repeated loading tightening rate(p < 0.05). 3. Cone screw groups have the highest initial stability and anal stability. 4. All groups are decreased tightening rate after repeated loading.

Change of Physical Properties of Under Wear by Repeated Washing. (반복 세탁에 따른 내의류의 물성변화에 관한 연구)

  • Song, Kyoung-Hun;Lee, Mun-Soo
    • The Journal of Natural Sciences
    • /
    • v.8 no.1
    • /
    • pp.137-143
    • /
    • 1995
  • The purpose of this study is to investigate the change of shrinkage, tensile strength, elasticity, light-fastness and color-fastness of 100% cotton upper under wear after acidic treatment and repeated washing and drying. Both of warp and welt were shrinked, especially in the early washing stage. Tensile strength was not weakened by 15 times of repeated washing. Hunter whiteness(HW) of white-underwear decreased, but color difference($\Delta$E) and yellow index(YI) increased corresponding to the frequency of washing and sunlight drying. The discoloration of color-underwear was significant in the early stage.

  • PDF

A Fatigue Analysis on Lumbar Extension Muscle during Repeated Trunk Extention Exercise for Chronic Lumbar Pain (만성요통환자의 반복체간운동 시 요부신전근 피로 분석)

  • So, Jae-Moo;Lee, Chul-Kyu
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.1
    • /
    • pp.159-166
    • /
    • 2006
  • The purpose of this study were analysed fatigue character of lumbar extension Muscle during repeated trunk flexion-extension motion we used EMG multi-telemeter (WEB 5000, Nihon Koden, Japan), Medex lumbar extension machine(Ocala, USA). We evaluated 20 persons on chronic low back pain group and 20 persons on control group. We analysed the quantitative variables IMF, MF, decreased ratios of MF to investigate fatigue. As a result, the following conclusion was drawn : 1. Each lumbar IMF of CLBP was L5> L3> L1 in the order of their size. CON group was similar quantitative and same order. But the relationship of two groups were not significantly. 2 The IMF within lumbar position(L1-L3, L1-L5, L3-L5) of two groups was significantly all positions(p<.05). 3. The MF shifting at lumbar position of two groups during repeated trunk flexion-extension motion was decrease shifting pattern with increase repeating motion, especially CLBP group was suddenly dropping than CON at all lumbar positions(L1, L3, L5) on early stage motion(34 set). 4. The lumbar fatigue of CLBP was higher than CON during repeated trunk flexion-extention motion, so CLBP supposed more tired than CON. And it was significantly within two groups at lumbar positions(L1, L3 : p<.05, L5 : P<.01).

Effects of TiN Coating on the Fatigue Fracture of Dental Implant System with Various Cyclic Loads

  • Jung, Da-Un;Chung, Chae-Heon;Son, Mee-Kyoung;Choe, Han-Cheol
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.6
    • /
    • pp.283-291
    • /
    • 2015
  • The purpose of this study was to investigate effects of TiN coating on the fatigue fracture of dental implant system with various cyclic loads. TiN coated abutment screw, the fixture, and abutment of internal hex type were prepared for fatigue test. The fatigue test was carried out according to ISO 14801:2003(E) using tensile and compression tester with repeated load from 30% to 80% of static fracture force. Morphology and fractured surface was observed by field emission scanning electron microscope(FE-SEM) and energy dispersive X-ray spectroscope(EDS). The fracture cycle drastically decreased as repeated load increased. Especially, in the case of TiN-coated abutment screw, fracture cycle increased compared to non-coated abutment screw. The fatigue crack was propagated fast as repeated load increased. The plastic deformation region decreased, whereas, cleavage fracture region increased as repeated load increased.

Elimination of Discontinuity Phenomenon for Repeated Play of Finite DTV Stream (유한 DTV 스트림의 반복 재생시 불연속 현상 제거)

  • Han, Chan-Ho;Sohng, Kyu-Ik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.10A
    • /
    • pp.951-961
    • /
    • 2002
  • In general, there is discontinuity phenomenon like a black screen and an irregular sound for repeated play of a finite digital stream. In this paper, for repeated play we analyze the relation between source and stream time causes this phenomenon. We obtain the time relation between video frame rate, audio frame rate, and TS packet transmission rate to eliminate this phenomenon. Using this time relation, we propose a new generation method of elementary stream (ES) and transport stream (TS) to eliminate discontinuity phenomenon. The test results of the generate ES and TS using the proposed method show that the discontinuity phenomenon can be eliminated for repeated play of a finite proposed stream.