• Title/Summary/Keyword: Repair materials

Search Result 1,112, Processing Time 0.026 seconds

Arthroscopic Treatment of Metallic Suture Anchor Failures after Bankart Repair (Bankart 수술 후 발생한 금속 봉합 나사못 합병증의 관절경적 치료)

  • Shin, Sang-Jin;Jung, Jae-Hoon;Kim, Sung-Jae;Yoo, Jae-Doo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.70-76
    • /
    • 2006
  • Purpose: This study presents 5 patients who had metallic anchor protrusion on glenoid after Bankart repair in anterior shoulder instability and reviewed the cause, clinical feature and arthroscopic removal technique. Method and Materials: 5 male with average age of 22 years (range 19 to 25 years) were included. 4 patients had arthroscopic Bankart repair and 1 patient had open repair for anterior shoulder instability. They had protruded metallic suture anchors on glenoid and the protruded suture anchors were removed arthroscopically using larger suture anchor empty inserter. Results: 4 patients had painful clicking sound with motion of abduction and external rotation and 1 patient showed shoulder instability. The ROM showed normal except mild degrees loss of external rotation. The position of protruded metallic anchor was 2, 3 and 5 O'clock in three patients and 4 O'clock in 2 patients. In 2 patients, the metallic suture anchor was malpositioned about 5mm off on the medial side from the anterior glenoid edge. All had Outerbrige classification Grade II-III chondral damage on humeral head and 1 patient showed glenoid cartilage destruction. None had shoulder instability after 2 years of follow-up. Constant score was 65 preoperatively and 89 postoperatively. ASES score was 67 preoperatively and 88 postoperatively. Conclusion: Symptoms of protruded suture anchor are not combined with instability. Most of symptoms were revealed from the rehabilitation period and confused with postoperative pain. Prompt diagnosis and early arthroscopic removal or impaction of protruded metallic suture anchor is recommended because of serious glenohumeral cartilage destruction. This is easy and simple and reproducible method to remove protruded metallic suture anchor arthroscopically.

  • PDF

Operative Treatment of the Displaced Bucket Handle Tear of the Medial Meniscus (내측 반월상 연골의 전위된 양동이 손잡이형 파열의 수술적 치료)

  • Hahn Sung-Ho;Yang Bo-Kyu;Yi Seung-Rim;Chung Shun-Wook;Lee Dong-Ho;Kim Min-Seok
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.142-149
    • /
    • 2002
  • Purpose : The purpose of this study is to compare with result of repair and resection in displaced bucket handle medial meniscal tear. Materials and Methods : From Sep. 1998 to Dec. 2001, we experienced 46 cases, 45 patients. We classified them into repair group (group I, 23 cases) and resection group (group II, 23 cases). We analyzed the time interval between injury and operation, zone of tear, the status of reduction and quality of displaced fragment of all cases. Average follow-up period is 29, 28 months, respectively. We evaluated the final results of both groups as Lysholm knee score, radiologic changes and 2nd look arthroscopy. Results : Mean age was 25 years old in both group, respectively. Mean interval between injury and surgical treatment was 12 and 17 weeks. respectively. In group I, 6 of 7 cases were evaluated as clinical success in red-red zone, 12 of 15 cases were assessed as clinical success in red-white zonal tear, stable reduction. Another case which is evaluated as clinical failure showed red-white zonal tear, unstable reduction and poor quality meniscal fragment. 5 cases showed variant degrees of tibio-femoral compartment symptom. In group II, red-white zone (9 cases) and white-white zone (14 cases) were treated as resection and got good results. Conclusion : Considering zone of tear, reducibility and quality of meniscal fragment before treatment will improve the success rate of meniscal repair.

  • PDF

Arthroscopic Transosseous Suture Repair for Bankart Lesion with a Flexible Drill Device - An Experimental and Preliminary Clinical Report - (유연성 천공기를 이용한 Bankart 병변의 골관통식 봉합 - 동물 실험 및 예비 임상 결과 보고 -)

  • Park, Jin-Su;Won, Ye-Yeon;Yoo, Jung-Han;Park, Yong-Wook;Noh, Kyu-Chul;Chung, Kuk-Jin;Kim, Hong-Kyun;Hwang, Ji-Hyo;Lee, Young-Bum;Suh, Il-Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.72-78
    • /
    • 2010
  • Purpose: Too develop a flexible drill device that can be inserted into the shoulder joint so that arthroscopic transosseous suture repair for Bankart lesion is possible. Materials and Methods: We created a device composed of a flexible drill unit and a guide pipe unit. The flexible drill unit was made of flexible multifilament wires (1.2 mm in diameter) that was twisted into one cord so that it can flex in any direction and a drill bit (1.2 mm in diameter) that is attached onto one end of the flexible wire. The guide pipe unit was a 150 mm long metal pipe (2.0 mm in inner diameter and 3.0 mm in outer diameter), with one end bent to 30 degrees. The flexible drill set was inserted into the shoulder joint through the posterior portal of the joint. The guide pipe component was placed onto the medial wall of the glenoid so that the pipe was placed 5 mm posterior to the margin of the anterior glenoid rim. The flexible drill was driven through the glenoid by the power drill so that holes were made in the glenoid. A non- absorbable suture was passed through the hole. Tying of a sliding knot tying was accomplished over the capsule and labrum after making a stitch through the capsule and labrum with a suture hook loaded with suture passer. The same procedures were done at the 2 and 4 O'Clock positions of the glenoid. Results: Five cases with Bankart lesion received arthroscopic transosseous repair with our flexible drill device. There were no intraoperative problems. Neither redislocation nor subluxation was reported at final follow-up. Conclusion: Arthroscopic transosseous suture repair without suture anchors and easy tying of a sliding knot are possible with a flexible drill set.

One Anchor Double Fixation (OADF) Technique for Arthroscopic Bony Bankart Repair (두가닥의 봉합사를 가진 봉합나사못을 이용한 새로운 관절경적 골성 방카르트 병변 봉합술)

  • Choi, Eui-Sung;Park, Kyoung-Jin;Kim, Yong-Min;Kim, Dong-Soo;Shon, Hyun-Chul;Cho, Byung-Ki;Bae, Seung-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2010
  • Purpose: The aim of this study was to evaluate the usefulness of arthroscopic Bony Bankart repair using a One Anchor Double Fixation Technique. Materials and Method: Seventeen patients with a Bony Bankart lesion were treated using the One Anchor Double Fixation Technique (OADF Technique). There were 13 males and 4 females. The average age was 24 years (range 17-42). The average follow-up period was 22.3 months. One 3.0 mm suture anchor with doubly loaded sutures was inserted into the glenoid rim. One suture strand was passed the around the small bony fragment and tied first. Another suture strand was passed through the capsule and tied over the bony fragment. The result was measured using Rowe's evaluation index & KSS score. The glenoid defect & bony fragment were measured by 3D-CT scan. Results: Rowe's evaluation index on the final follow-up showed an overall improvement from an average of 54 (range, 23-71) to 83.4 (range 71-90). Of the 17 cases, 13 were excellent, 3 were good, and 1 was fair. KSS scores showed improvement from an average of 71 (range 49-82) to 92.5 (range 82-94). There were no cases where pain continued to the final follow-up, and no cases being re-dislocated during the follow-up period. For six cases, we confirmed the bony healing of the bony Bankart lesion by CT. Conclusion: Bony Bankart lesion repair using this new method achieves excellent clinical results with low recurrence rates and is considered another choice for bony Bankart lesions.

The results of arthroscopic repair according to the delamination of rotator cuff (회전근 개 판분리 파열에 따른 관절경하 회전근 개 봉합술의 결과)

  • Ku, Jung Hoei;Cho, Hyung Lae;Park, Man Jun;Kim, Jeong Cheol
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.2
    • /
    • pp.61-68
    • /
    • 2011
  • Purpose: We evaluated the clinical outcome after arthroscopic repair in full thickness rotator cuff tears with and without delamination. Materials and Methods: From March 2006 to October 2008, we included 48 consecutive shoulders (31 males, 17 females; mean age 57.6 years; 45~68) who had arthroscopic double row repair for fullthickness tears of the rotator cuff. Mean rotator cuff tear size was 2.8 cm (range: 1.2~3.6) and the techniques of tendon-to-bone fixation varied according to the presence of delamination; separate row fixations of bursal and articular layer were used in delaminated tear. The mean follow-up was 26 months (range: 18~33) and functional and structural results were evaluated by American Shoulder and Elbow Surgeons (ASES), University of California at Los Angeles (UCLA) scale, isokinetic strength testing and magnetic resonance imaging (MRI) obtained mean 8 months (range:6~13) postoperatively. The patterns of delamination, age, sex, symptom duration, size of tear, satisfaction rate, retear rate ware compared and significance was set at p values < 0.05. Results: Postoperative functional shoulder score improved significantly in 44 shoulders (91.7%). Delamination was observed in 15 shoulders (31%) and it extended proximally and posteriorly in the majority of shoulders, and the articular layer was thicker (8/15, 53%) and more retracted (9/15, 60%) compared with the superficial bursal layer. Final follow up functional shoulder scores showed no differences between non-delaminated and delaminated tears and the presence of delamination had no correlations with sex, symptom duration, tear size and satisfaction rate, however, older age had more delaminated tears (p=0.041). Follow up MRI in 29 shoulders revealed that fourteen (48%) shoulders had complete healing; nine (31%), partial healing; six (21%), complete retear but the half of the retear group showed favorable clinical results. 79% (15/19) in non-delaminated tear and 80% (8/10) in delaminated tear were judged as healed tendon on MRI and double-layer double row repairs in delaminated tears resulted in nearly same rate of structural integrity of single-layer double row repairs (p=0.165). Conclusion: The incidence of delamination in our series was 31% and older age had more delaminated tears. Sex, symptom duration, preoperative size of the tear, functional results and satisfaction rate had no significant correlations with the presence of delamination. Nearly the same postoperative structural integrity was noted in both delaminated and non-delaminated tears.

  • PDF

The Results of Arthroscopic Double-Row Rotator Cuff Repairs with Combined Knot-tying and Knotless Suture Anchors (매듭 결속과 비매듭 봉합나사를 이용한 관절경적 이열 회전근개 봉합술의 결과)

  • Ku, Jung-Hoei;Lee, Choon-Key;Cho, Hyung-Lae;Choi, Seung-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.172-179
    • /
    • 2008
  • Purpose: To evaluate the functional and structural results of arthroscopic double-row repair using combined knot-tying and knotless suture anchors in rotator cuff tears. Materials and Methods: From March 2006 to June 2007, twenty-one patients (15 males, 6 females; mean age 55.6 years; range 48 to 67) were included who underwent arthroscopic double-row repair for full-thickness tears of the rotator cuff following conservative treatment for a mean of 6.5 months (range 3 to 11). The tear size was carefully inspected arthroscopically and we found 2 small, 13 medium and 6 large-sized rotator cuff tears, with a mean tear size of 2.5cm(range 1.8 to 3.2). The repair constructs were consisted of horizontal mattress sutures using conventional knot-tying suture anchors medially and simple suture at the same level of medial row stitch with Bioknotless RC anchors (DePuy Mitek, Norwood, MA) as lateral row. Clinical and functional evaluations were made according to the range of motion, the ASES, UCLA scale and the isokinetic strength testing. Postoperative cuff integrity was determined through magnetic resonance imaging. The mean follow-up was 15 months (range 13 to 24). Results: The average clinical outcome scores and strength were all improved significantly at the time of the final follow-up (p < 0.01). Nineteen patients (90%) were satisfied with the result of the treatment. In 17 of 21 patients (81%) were judged to reveal healed tendon on magnetic resonance imaging at a mean of 7 months postoperatively. There were no significant functional differences according to the preoperative tear size (p<0.01), but large-sized tear shows less favorable structural results in 3 out of 6 cases(50%). Conclusion: Our results document the usefulness and variability of arthroscopic double-row rotator cuff repairs comparable to the results of the other types of double-row repairs.

  • PDF

The Result of Rotator Cuff Repair Using Arthroscopic Margin Convergence Technique in Irreparable Large and Massive Rotator Cuff Tears (해부학적 봉합이 불가능한 회전근 개 파열에서 관절경하 모서리 맞춤 술식을 이용한 봉합의 결과)

  • Choi, Eui-Sung;Park, Kyoung-Jin;Kim, Yong-Min;Kim, Dong-Soo;Shon, Hyun-Chul;Cho, Byung-Ki;Park, Ji-Kang;Lee, Hyung-Joon
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.46-52
    • /
    • 2011
  • Purpose: This study was performed to assess the usefulness of non-anatomical repair for irreparable large and massive rotator cuff tears by the arthroscopic margin convergence technique. Materials and Methods: Twenty-two patients were followed up more than 1 year after non-anatomical repair for irreparable large and massive rotator cuff tears using the arthroscopic margin convergence technique. The clinical evaluation was performed according to the KSS score, the UCLA score and the Visual analogue scale (VAS). The measurement of the acromio-humeral distance was performed using the shoulder anterior-posterior radiographs. The measurement of fatty degeneration and the healing status was performed using the shoulder MRI after 6 months. Results: Among twenty-two patients, follow up MRI was performed in eleven cases. Three cases were well healed, four cases were partial healed and another four cases were re-torn. The KSS and UCLA scores had significantly improved from a preoperative average of 45.0${\pm}$8.014 and 10.8${\pm}$2.302 points to 77.1${\pm}$10.151 and 30.0${\pm}$1.521 points, respectively, and the pain VAS had decreased from a preoperative average of 7.7${\pm}$0.616 points to 3.0${\pm}$1.021 points at the last follow up. Less favorable results were obtained when the patient had a grade of fatty degeneration higher than grade 3 on the preoperative MRI. Conclusion: Non-anatomical repair for irreparable large and massive rotator cuff tears by the arthroscopic margin convergence technique showed good functional results. It seems to be one of the effective treatment methods for irreparable large and massive rotator cuff tears.

Clinical Result of Layered Suture Bridge Technique in Arthroscopic Repair for Delaminated Rotator Cuff Tear (회전근 개 층간 분리 파열에서 관절경을 이용한 층상 교량형 봉합술의 임상 결과)

  • Choi, Eui-Sung;Park, Kyoung-Jin;Kim, Yong-Min;Kim, Dong-Soo;Shon, Hyun-Chul;Cho, Byung-Ki;Park, Ji-Kang;Kim, Dong-Whan;Keum, Sang-Wook;Cha, Jung-Kwon
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.2
    • /
    • pp.84-93
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the repair integrity and clinical outcomes of delaminated tears following arthroscopic layered suture bridge rotator cuff repair in a prospective fashion. Materials and Methods: A consecutive series of 67 patients with delaminated rotator cuff tears who underwent surgery using the arthroscopic Layered Suture Bridge Technique were followed prospectively. Of 67 shoulders, 26 patients were male and 40 patients were female (one patient had bilateral tears); the mean age was 58.8(40~76) years. The clinical evaluation was performed according to ASES, UCLA, and KSS (Korea Shoulder Scoring System) scores with an average follow up period of 33 months. Repair integrity was estimated using MRI, which was performed six months postoperatively. Results: The average clinical outcome in ASES, UCLA, and KSS scores showed significant improvement at the time of the final follow-up compared to preoperatively, from 50.2 to 92.3, 15 to 31.3, and 54.4 to 90.7, respectively (p<0.001 for all scores). Follow up by MRI showed that 16 shoulders had a type-I; 14, a type-II; five, a type-III; two, a type-IV; one, a type-V re-tear. The overall rate of re-tear (types IV and V) was 7.9%. Conclusion: Use of the Arthroscopic Layered Suture Bridge Technique can result in improved functional and structural outcome in cases of delaminated rotator cuff tear.

Pain Recovery Pattern According to the Integrity after an Arthroscopic Rotator Cuff Repair (관절경하 회전근 개 봉합술 후 파열 정도에 따른 통증 회복 양상)

  • Kim, Ju-O;Sim, Sang-Don;Noh, Kyung-Hwan;Shon, Suk-June;Kim, Sul-Jun;Yang, Yun-Hyeok
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.2
    • /
    • pp.155-160
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the pain recovery pattern according to the integrity and to analyze the factors affecting the progress and level of pain postoperatively. Materials and Methods: We examined 153 patients, who were treated with arthroscopic rotator cuff repair. 101 rotator cuff tears were full-thickness tear and 52 were partial tear. The mean follow up duration was 20 months (12~30 months). We evaluated the visual analogue scale, range of motion, ASES (American Shoulder and Elbow Surgeons), and UCLA (University of California at Los Angeles) scores preoperatively and postoperatively. We analyzed the pain recovery pattern between partial and full thickness tear using Student T-test and the factors affecting the progress and level of postoperative pain using multiple regression analysis. Results: The change patterns of visual analogue scale after arthroscpoic repair were similar regardless of the tear integrity. The VAS showed a continuous decreasing pattern, but increased at first 3 weeks postoperatively and at 7 weeks postoperatively, and then, decreased thereafter. The average VAS was ${\leqq}2$ points by postoperative 3 months. The factor affecting the pain score at 3 months was related to the preoperative limitation in forward flexion ($r^2=0.377$, p=0.021). Conclusion: There was no differences of the pain recovery pattern according to the integrity, and the factor affecting the progress of postoperative pain was preoperative angle of forward elevation. So, the appropriate preoperative rehabilitation protocol that can improve motions of the shoulder joint would help to improve the level of postoperative pain and functional recovery.

  • PDF

Development of Portable X-ray CT System II - CT Image Reconstruction of Wood using Density Distribution - (현장 적용이 가능한 X선 CT 시스템 개발 II- 밀도분포를 이용한 목재의 CT영상 구성 -)

  • Kim, Kwang-Mo;Lee, Sang-Joon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.23-31
    • /
    • 2006
  • X-ray transit materials with straight path and the its intensity is proportional to the density of materials. Therefore, X-ray has been extensively used as a nondestructive evaluation (NDE) method in various fields. This study was carried out for development of a portable X-ray CT (computed-tomography) system to detect deteriorations of wood members in buildings. Based on the results of our previous study, a procedure of CT image reconstruction was established In order to verify the applicability of developed system, CT images of three wood disks were reconstructed by newly developed procedure and compared with the prototypes. From the results of this study, it was shown that the newly developed system could be used not only to determine the shape, size, and position of defects, but also to find the density distribution in cross section of wood structure members. The density distribution may be utilized to clarify the reason of wood deterioration and to provide the preventive method on how to treat or repair wood buildings. Because it was initial stage of system development, there were some limitations concerned with measuring equipment and image reconstruction algorithm. Especially, measuring time including equipment setup time was longer and measuring accuracy was lower than we expected. Therefore, we planned some additional studies on improvement of equipment and algorithm to enhance the capability of X-ray CT system.