• Title/Summary/Keyword: Renewable source

Search Result 710, Processing Time 0.022 seconds

Study on COP Variations with the duration of Ground Source Heat Pump Systems Operation (지열히트펌프의 작동시간 경과에 따른 COP 변화에 대한 연구)

  • Lee, Yonggyu;Baek, Namchoon;Yoon, Eungsang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.198.2-198.2
    • /
    • 2010
  • In this study, the COP variation with the duration of Ground Source Heat Pump (GSHP) systems operation was analyzed by experiment. This experimental facility was installed in residential house as a back-up device of solar thermal heating system. The capacity of heat pump is 2.5 kW with a vertical bore hole of 150m depth. The COP of GSHP is varied, depending on the ground temperature which is used as a heat source. The ground heat source temperature influencing heating COP is the soil or rock temperature which adjoin with geo-source heat exchanger. This temperature is decreased rapidly according to the operation duration of heat pump. As a result, COP of GSHP is decreased to 3 in one hour of continuous operation time.

  • PDF

Single-Inductor, Multiple-Input-Single-Output Converter Based Energy Mixer for Power Packet Distribution System

  • Reza, C.M.F.S.;Lu, Dylan Dah-Chuan;Qin, Ling;Qi, Jian
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1479-1488
    • /
    • 2018
  • Power packet (PP) distribution system distributes power to different loads that share the same distribution cable in a packetized form. When compared with conventional power systems, a PP distribution system (PPDS) can reduce standby power, eliminate Point-of-Load (PoL) power conversion, and intelligently control the load demand from the source side. Due to the absence of PoL conversion, when multiple power sources at different voltage levels and conditioning requirements jointly send power to various loads at different voltage ratings, the generated voltage has an irregular shape. A large filter at each of the load sides is required to reduce such a large voltage ripple. In this paper, a single-inductor, multiple-input-single-output converter structure based multiple-energy-source mixer is proposed. It combines PP generation, maximum power point tracking (MPPT) of renewable energy sources (RESs) and filtering at the source side. To demonstrate the possible renewable energy integration, a PV panel is used as a power source together with other constant voltage sources. The PV power is approximately tracked using the constant voltage method and it is used for each of the PP generations. The proposed PP distribution system is experimentally verified and it is shown that a conventional PI controller is sufficient for stable system operation.

Source Model for Harmonic Interaction Analysis between Renewable Energy Generators and Power Distribution System (계통 고조파와 분산형 전원의 상호작용 평가를 위한 고조파 모델에 관한 연구)

  • Cho, Sung-Min;Shin, Hee-Sang;Moon, Won-Sik;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.733-738
    • /
    • 2011
  • As increase of nonlinear loads and renewable energy generators (REGs) being connected to power distribution system via inverters, the concern on harmonic problems have increased. Recently, the harmonics evaluation method considering TDD (Total Demand Distortion) is used to analyze the effect of harmonics from inverters on power distribution quality. Harmonic current sources are typically used for simulation of nonlinear load. Most inverter type for REGs is voltage source inverter (VSI). So, harmonic voltage sources are more suitable to analyze impact of renewable energy generator on harmonics problem in power distribution system. In this paper, we presented the circuit model to analyze interaction between harmonics from nonlinear load and REGs. We verified that the harmonic analysis using the proposed circuit model is more appropriate than the harmonics evaluation method considering TDD through case study using PSCAD/EMTDC.

Operational Strategy for a BESS-based Microgrid (BESS 기반 마이크로그리드 운영전략)

  • Lee, Ha-Lim;Chun, Yeong-Han
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1666-1672
    • /
    • 2015
  • Small islands are quite adequate places where microgrid system with renewable sources can replace diesel engines as operation costs of diesel engine in most small islands are very high. To get the large amount of renewable energy, the microgrid system has very large capacity of renewable sources. The system with large capacity of renewable sources can meet the case when supplied energy is greater than the load and the fluctuation of source output is very large. The battery energy storage system can be a solution to stabilize the system with large capacity of renewable sources. In this case, BESS can be utilized as a master source for the synchronous operation of all sources including diesel engine, wind turbine and PV. The diesel generators can be used as a backup in case the BESS SOC goes below a certain level. In this paper, we suggest a novel unit commitment of diesel generators and operation schedule of pump for water supply service with the information of wind forecast, PV forecast, and load forecast. The proposed methods has been implemented and tested at the test bed in Gasa-Island.

Analytical Study on the Performance of Ground Source Compound Hybrid Heat Pump System for Large Community Building (대형 Community 건물의 지열원 복합 하이브리드 히트펌프 시스템 성능에 관한 해석적 연구)

  • Byun, Jae-Ki;Jeong, Dong-Hwa;Lee, Jong-Gil;Hong, Seong-Ho;Choi, Young-Don;Cho, Sung-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.634-637
    • /
    • 2008
  • Ground source heat pumps are clean, energy-efficient and environment-friendly systems cooling and heating. Although the initial cost of ground source heat pump system is higher than that of air source heat pump, it is now widely accepted as an economical system since the installation cost can be returned within an short period of time due to its high efficiency. In the present study, performances of ground source compound hybrid heat pump system applied to a large community building are simulated. The system design and operation process appropriate for the surrounding circumstance guarantee the high benefit of the heat pump system applied to a large community building. If among several renewable energy sources, ground, river, sea, waste water source are chosen as available alternative energies are combined, COP of the system can be increased largely and hybrid heat pump system can reduced the fuel cost.

  • PDF

Correlation Analysis between the Renewable Energy Source Generation and the Utilization for Smart Grid in Korea (한국의 스마트 그리드를 위한 신재생에너지원 생산과 활용률 간의 상관관계 분석)

  • Hyun, Jung Suk;Park, Chan Jung;Lee, Junghoon;Park, Kyung Leen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.347-353
    • /
    • 2017
  • In order to prohibit global warming, various kinds of regulatory policies have been established in the whole world. One example is the establishment of the Renewable Portfolio Standard. It requires the increased portion in energy production from renewable energy sources. The Republic of Korea adopted the act on the promotion of the development, use, and diffusion of new and renewable energy since 2012. However, in spite of the effort on the consideration of the renewable energy sources, it was reported the carbon intensity of electricity in Korea was not that low in 2015. Thus, it is required to examine the recent state of the utilization degree of the renewable energy sources in Korea. This paper analyzed the statistical data provided by Korea Power Exchange (KPX) to examine any problems and solutions for generating electricity from the renewable energy sources. We focused on the generation capacity provided by the power plants participated in the market, the electric power trading amount, and the utilization coefficient for 10 years. By analyzing the data, we provide an alternative to solve some imbalance among the factors contributing to renewable energy use.

Information Strategy Planning for GIS based Management System Development with New Renewable Energy Resource Information

  • Kim Kwang-Deuk;Jeong Jae-Hyuck
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.313-316
    • /
    • 2005
  • New renewable energy information becomes one of the greatest issues all over the world because of serious environment problems and limited fossil resources. The new renewable energy source information system is treated seriously for efficient management and distribution as dealing with these energy problems. However, it is difficult to manage and utilize new renewable energy information because gathering and surveying information is progressed individually in each research field. Therefore this paper will establish ISP(Information strategy Planning) and propose the basic management system based-on GIS to analyze new renewable energy such as solar energy, wind power, small hydro, biomass, geothermal etc. and build the integration management system. The proposed integration management system can provide spatial analysis using thematic map, data search, data import/export and interpolation about users quenes.

  • PDF

An Analysis of Problems and the Current Status of Renewable Energy System in Buildings (건축물 신재생에너지원의 이용 현황 및 문제점 분석)

  • Jang, Hyang-In;Seong, Yoon-Bok;Cho, Young-Hum;Kim, Yong-Shik;Jo, Jae-Hun
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.75-82
    • /
    • 2012
  • This study aims to investigate the usage of the renewable energy systems installed in buildings and make suggestions for the effective management. In this regard, a questionnaire survey was conducted on 1)design and construction, 2) operation and management, 3) user satisfaction and improvements about the renewable energy systems in buildings. Findings from this study can be summarized as follows; a lack of the basic information about systems, non-use of energy management systems, the differences in the features by energy source, and a lack of expertise of managers. The requirements to resolved these problems include the integrated management of various electric heat sources including a renewable energy source, an operation schedule based on the prediction of production and consumption, and so on. Furthermore the necessity of multiplex energy sources management system was confirmed and the basic data needed to establish the targets of this system were obtained.

Simulation Analysis of Bio-Methane Decomposition Using Solar Thermal Energy (태양열 이용 바이오메탄 분해 해석연구)

  • Kim, Haneol;Lee, Sangnam;Lee, Sang Jik;Kim, Jongkyu
    • New & Renewable Energy
    • /
    • v.17 no.1
    • /
    • pp.40-49
    • /
    • 2021
  • In this study, the optical properties, heat transfer capabilities and chemical reaction performance of a methane thermal decomposition reactor using solar heat as a heat source were numerically analyzed on the basis of the cavity shape. The optical properties were analyzed using TracePro, a Monte Carlo ray tracing-based program, and the heat transfer analysis was performed using Fluent, a CFD program. An indirect heating tubular reactor was rotated at a constant speed to prevent damage by the heat source in the solar furnace. The inside of the reactor was filled with a porous catalyst for methane decomposition, and the outside was insulated to reduce heat loss. The performance of the reactor, based on cavity shape, was calculated when solar heat was concentrated on the reactor surface and methane was supplied into the reactor in an environment with a solar irradiance of 700 W/㎡, a wind speed of 1 m/s, and an outdoor temperature of 25℃. Thus, it was confirmed that the heat loss of the full-cavity model decreased to 13% and the methane conversion rate increased by 33.5% when compared to the semi-cavity model.