Browse > Article
http://dx.doi.org/10.5370/KIEE.2011.60.4.733

Source Model for Harmonic Interaction Analysis between Renewable Energy Generators and Power Distribution System  

Cho, Sung-Min (숭실대 전기공학과)
Shin, Hee-Sang (숭실대 전기공학과)
Moon, Won-Sik (숭실대 전기공학과)
Kim, Jae-Chul (숭실대 전기공학과)
Publication Information
The Transactions of The Korean Institute of Electrical Engineers / v.60, no.4, 2011 , pp. 733-738 More about this Journal
Abstract
As increase of nonlinear loads and renewable energy generators (REGs) being connected to power distribution system via inverters, the concern on harmonic problems have increased. Recently, the harmonics evaluation method considering TDD (Total Demand Distortion) is used to analyze the effect of harmonics from inverters on power distribution quality. Harmonic current sources are typically used for simulation of nonlinear load. Most inverter type for REGs is voltage source inverter (VSI). So, harmonic voltage sources are more suitable to analyze impact of renewable energy generator on harmonics problem in power distribution system. In this paper, we presented the circuit model to analyze interaction between harmonics from nonlinear load and REGs. We verified that the harmonic analysis using the proposed circuit model is more appropriate than the harmonics evaluation method considering TDD through case study using PSCAD/EMTDC.
Keywords
Harmornics; Renewable energy generators; Superposition;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
Times Cited By SCOPUS : 0
연도 인용수 순위
1 IEEE 519, IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems, 1992
2 IEEE 1547.1, IEEE Standard Conformance Test Procedures for Equipment Interconnecting Distributed Resources with Electric Power Systems, 2005
3 IEC61000-3-6, Assessment of emission limits for distorting loads in MV and HV power systems - Basic EMC publication, 2008
4 S. K. Kim, J. H. Jeon, C. H. Cho, E. S. Kim, J. B. Ahn, "Modeling and simulation of a grid-connected PV generation system for electromagnetic transient analysis", Solar Energy, Vol. 83, No. 5, May 2009, 664-678   DOI   ScienceOn
5 David G. Infield, Peter Onions, Anton D. Simmons and Gordon A. Smith, "Power Quality From Multiple Grid-Connected sing-phase Inverters", IEEE Trans. on Power Delivery, Vol. 19, No. 4, pp. 1983-1989, 2004   DOI   ScienceOn
6 IEEE Harmonics Working Group and SCC22, "Guide for Applying Harmonics Limits on Power Systems", 1996
7 Roger C. Dugan, M. F. McGranaghan, "Electrical Power System Quality", McGraw-Hill, 2004
8 Wenqiang He, Hans Peter Nee, "Current Harmonics Analysis of The DG Interconnection by Modeling and Simulation", IEEE/PES T&D Conference & Exhibition, 2005
9 김경철, 김유준, "실측에 의한 특고압 수용가의 고조파 평가에 관한 연구", 조명전기 설비학회 논문지, 제21권, 제3호, pp. 50-55, 2007   DOI
10 김경철, 진성은, 이주홍, 전영수,"시간에 따라 변하는 전기로 부하의 고조파 측정, 평가 및 시뮬레이션에 관한 연구", 조명전기 설비학회 논문지, 제 20권, 제 5호, pp. 9-17, 2006   DOI
11 한국 전력 공사 배전품질팀, "배전계통 고조파 관리기준(잠정)", 2009
12 Makoto Saito, Takaharu Takeshita and Nobuyuki Masui, "Modeling and Harmonic Suppression for Power Dirtribution Systems", IEEE Trans. on Industrial Electronics, Vol. 50, No. 6, pp. 1148-1158, 2003   DOI   ScienceOn
13 왕용필, 정종원, 정동일, "배전 시스템의 고조파 분석 및 모델링에 관한 연구", 조명전기 설비학회 논문지, 제21권, 제 3호 p62-68, 2007   DOI
14 유상봉, "전기설비에서의 고조파 대책 기술", 조명전기 설비학회지, 제 13권, 제 4호, p40-52, 1999,
15 한국 전력 공사 배전처, "분산형 전원 배전계통 연계 기술기준", 2005
16 IEEE 1547, "IEEE Standard for Interconnecting Distributed Resources with Electric Power Systems", 2003
17 F. Blaabjerg, R. Teodorescu, M. liserre and A. V. Timbus, "Overview of Control and Grid synchronization for Distributed Power Generation Systems", IEEE Transaction on Industrial Electronics, Vol. 53, No. 5, October, 2006   DOI   ScienceOn
18 지식경제부, "스마트그리드 국가로드맵", 2010, 01, 25