• Title/Summary/Keyword: Renewable energy generator

Search Result 347, Processing Time 0.032 seconds

A Study on the Energy Saving Capacity of Solar Power Generation System using Economic Evaluation (경제성 평가를 통한 태양광발전시스템 연계형 에너지저장장치 용량 선정에 관한 연구)

  • Lee, Yeo-Jin;Kim, Sung-Yul;Han, Se-Kyung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.1
    • /
    • pp.21-26
    • /
    • 2018
  • Due to the international environmental regulations and changes in policies, the demand for generators using the renewable energy is increasing. However, renewable energy generators with intermittent output characteristics such as solar and wind power generators, need the buffer facilities such as ESS during system operations. However, because of low price competitiveness in energy storage system, it is difficult to operate the renewable energy generator with ESS. Therefore, the government has recently proposed a policy to compensate the REC for renewable energy system with ESS. For all this, since the initial cost of the ESS is high, it is the most important to calculate and operate the optimal capacity of the ESS through an economic analysis. In this paper, we proposed the method of calculation the optimal capacity of ESS and analyzed economic feasibility of renewable energy system using the ESS according to depreciation in ESS price.

Characterization of a Micro Power Generator using a Fabricated Electroplated Coil Measured at Low Frequency (금도금 방법으로 제작한 코일을 이용한 초소형 발전기의 저주파 진동 특성분석)

  • Lee, Dong-Ho;Kim, Seong-Il;Lee, Yoon-Pyo;Baek, Chang-Wook
    • New & Renewable Energy
    • /
    • v.2 no.3
    • /
    • pp.10-14
    • /
    • 2006
  • We have designed and fabricated coil structures by gold electroplating technique. The thickness, width, and length are $7{\mu}m,\;20{\mu}m$, and 1.6m, respectively. With vibrating a magnet on the surface of a fabricated electroplated coil, the micro power generator produce an alternating voltage. We have changed the vibrational frequency from 0.5Hz to 8Hz. The generated voltage was 106mV at 3Hz and 198mV at 6Hz. We have rectified and stepped up the input voltage using a quadrupler circuit. After using the step up circuit, the measured voltage was 81mV at 3Hz and 235mV at 6Hz.

  • PDF

A Study on Stable Operating for Buan S/S Byunsan D/L (2728 02) Power Distribution Area Connected with Wind Power Generator (부안 S/S 변산 D/L(2728 02) 공급구역을 대상으로 한 풍력발전시스템 계통연계 시 보호협조 방안)

  • Jang, Mi-Hye;Shin, Baek-Sik;Song, Weon-Jin;Kim, Yeong-Min;Kim, Dong-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.508-509
    • /
    • 2008
  • A creation of large and small scale wind farm was considered to proper already, as according to real Jeonbuk Saemangeum project. A grow larger to be construction of the new and renewable energy thema park as well as creation possibility of large scale wind farm afterward. Therefore, in this paper was proposed a counterplan on D/L protection cooperation of Buan S/S Byunsan D/L (2728 02) power distribution line in case of connected with wind power generator.

  • PDF

Power and Economic Simulation of Island for the Field Demonstration Test of Smart Microgrid System Based on Stand-alone Wind power (독립형 풍력기반 Smart Microgrid 시스템의 현장 실증 시험을 위한 도서지역 전력 및 경제성 시뮬레이션)

  • Kang, SangKyun;Lee, EunKyu;Lee, JangHo
    • New & Renewable Energy
    • /
    • v.10 no.3
    • /
    • pp.22-30
    • /
    • 2014
  • The isolated self-generating electricity with diesel engine generator has been used in islands far away from main land. It costs high because of increasing oil price, and unsafe to have supplying oil and its related components by ship due to unexpectable marine conditions. Therefore there is the need for the hybrid system of renewable energy like wind or solar energy systems with oil engine generator, which can reduce oil use and extend oil supplying period. In this study, the feasibility of such hybrid system with smart micro grid on the eight islands of Jeon-nam province is surveyed to find good place for the demonstration test of the hybrid system. In each island, 3 wind turbine systems of 10 kW and photovoltaic of 20 kW are tested with already installed diesel engine. The performance and costs of the hybrid system in each island are compared in the given conditions of solar and wind energy potential. As a result of the study, Jung-ma island is recommended for the optimum place to make real field demonstration test of isolated hybrid generating and smart grid systems.

Review of Wind Energy Publications in Korea Citation Index using Latent Dirichlet Allocation (잠재디리클레할당을 이용한 한국학술지인용색인의 풍력에너지 문헌검토)

  • Kim, Hyun-Goo;Lee, Jehyun;Oh, Myeongchan
    • New & Renewable Energy
    • /
    • v.16 no.4
    • /
    • pp.33-40
    • /
    • 2020
  • The research topics of more than 1,900 wind energy papers registered in the Korean Journal Citation Index (KCI) were modeled into 25 topics using latent directory allocation (LDA), and their consistency was cross-validated through principal component analysis (PCA) of the document word matrix. Key research topics in the wind energy field were identified as "offshore, wind farm," "blade, design," "generator, voltage, control," 'dynamic, load, noise," and "performance test." As a new method to determine the similarity between research topics in journals, a systematic evaluation method was proposed to analyze the correlation between topics by constructing a journal-topic matrix (JTM) and clustering them based on topic similarity between journals. By evaluating 24 journals that published more than 20 wind energy papers, it was confirmed that they were classified into meaningful clusters of mechanical engineering, electrical engineering, marine engineering, and renewable energy. It is expected that the proposed systematic method can be applied to the evaluation of the specificity of subsequent journals.

A Study on the Weekly Capacity Factor Assessment of Solar Cell Generator (태양광에너지전원의 주간설비이용율 추정에 관한 연구)

  • Park, Jeon-Je;Wu, Liang;Choi, Jae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.468_469
    • /
    • 2009
  • The application of renewable energy in electric power systems is growing rapidly in order to make provision for the inequality of the climate, the dwindling supplies of coal, oil and natural gas and a further rise in oil prices. Solar cell generators(SCG) is one of the fastest growing renewable energy. A study on the renewable energy is getting more important for the application of renewable energy. This paper presents the capacity factor of SCG by calculating the probabilistic production energy of SCG.

  • PDF

A Study on the ESS Integration Plan with Inner PCS of Wave-Offshore Hybrid Generation System for Maximizing Power Profile Stability (복합발전의 공급전력 안정성 극대화를 위한 파력발전 PCS의 BESS 연동방안 연구)

  • Jung, Seungmin;Kim, Hyun-Wook;Yoo, Yeuntae;Jang, Gilsoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.5
    • /
    • pp.82-91
    • /
    • 2014
  • The combined generator system by integrating several renewable energy sources can share the electrical infrastructure and therefore have the advantage of constructing not only the transmission system but also the power conversion system. Among the various combined renewable system, the wind power and wave power has a high possibility of future growth due to the economic feasibility in offshore environment. This kind of large-scale combined systems might be follow the determination by the transmission system operator's directions and control the output profile by focusing at PCC. However, both renewable energies are depend on the unpredictable environmental variation; it is needed to do the compensation devices. In this paper, the ESS compensation plan is proposed to do output determination of the combined generator system by paying attention to active power of utility grid with the analysis of the controllable elements of the wind and wave power generator. The improvement of the new application technique of the combined system is confirmed through using the PSCAD/EMTDC. The entire simulation process was designed by adopting the active power control according to the reference signal of TSO.

A New Design of Wave Energy Generator Using Hydrostatic Transmission (정유압 구동식 변속기를 사용한 새로운 파력 발전기 설계)

  • Ahn, Kyoungkwan;Dinh, Quangtruong;Yoon, Jongil
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.171-171
    • /
    • 2010
  • An innovative design of a floating-buoy wave energy converter (WEC) using hydrostatic transmission (HST), named HSTWEC, is presented in this paper. The system is designed to convert ocean wave fluctuation into electricity by using the HST circuit and an electric generator. Based on the floating-buoy concept, the wave forces the sub-buoy to move up and down. Consequently, the electric power can be obtained from the generator in both the moving directions of the sub-buoy through the HST circuit as shown in Fig. 1. In order to investigate the HSTWEC operations, a mathematical model of the system is indispensible. In addition, the method to control the HSTWEC, including: pump displacement control, tension adjustment control and ballast weight control, is also discussed in this paper. Finally, the design concept as well as simulation results indicated that this HSTWEC design is an effective solution and possible to fabricate for wave energy generation.

  • PDF

Source Model for Harmonic Interaction Analysis between Renewable Energy Generators and Power Distribution System (계통 고조파와 분산형 전원의 상호작용 평가를 위한 고조파 모델에 관한 연구)

  • Cho, Sung-Min;Shin, Hee-Sang;Moon, Won-Sik;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.733-738
    • /
    • 2011
  • As increase of nonlinear loads and renewable energy generators (REGs) being connected to power distribution system via inverters, the concern on harmonic problems have increased. Recently, the harmonics evaluation method considering TDD (Total Demand Distortion) is used to analyze the effect of harmonics from inverters on power distribution quality. Harmonic current sources are typically used for simulation of nonlinear load. Most inverter type for REGs is voltage source inverter (VSI). So, harmonic voltage sources are more suitable to analyze impact of renewable energy generator on harmonics problem in power distribution system. In this paper, we presented the circuit model to analyze interaction between harmonics from nonlinear load and REGs. We verified that the harmonic analysis using the proposed circuit model is more appropriate than the harmonics evaluation method considering TDD through case study using PSCAD/EMTDC.

CFD Performance analysis of Micro Tubular-type hydro turbine by blade shape (블레이드 형상 변화에 따른 마이크로 튜블러 수차의 CFD 성능해석)

  • Park, Ji-Hoon;Hwang, Young-Cheol;Mo, Jang-Oh;Kim, You-Taek;Lee, Young-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.206.1-206.1
    • /
    • 2011
  • Recently, various developments in the area of small hydropower have being made and small hydro turbines are suitable for domestic use because it is a clean and renewable energy source. A small hydropower generator produces power by using the different water pressure levels in pipe lines and energy which was initially wasted by use of a reducing valve at the end of the pipeline is instead collected by a tubular-type hydro turbine in the generator. In this study, in order to acquire the performance of tubular-type hydro turbine applied, the output power, head, efficiency characteristics due to the different guide vane and runner vane angle are examined in detail. Moreover, influences of pressure and velocity distributions with the variation of guide vane and runner vane angle on turbine performance are investigated by using a commercial CFD code.

  • PDF