• Title/Summary/Keyword: Renal imaging

Search Result 177, Processing Time 0.022 seconds

Preliminary evaluation of new 68Ga-labeled cyclic RGD peptides by PET imaging

  • Shin, Un Chol;Jung, Ki-Hye;Lee, Ji Woong;Lee, Kyo Chul;Lee, Yong Jin;Park, Ji-Ae;Kim, Jung Young;Kang, Joo Hyun;An, Gwang Il;Ryu, Young Hoon;Choi, Jae Yong;Kim, Kyeong Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.2 no.2
    • /
    • pp.118-122
    • /
    • 2016
  • Integrin ${\alpha}_v{\beta}_3$ plays an important role in the tumor metastases and angiogenesis. Arginine-glycine-aspartate (RGD) peptide motif binds to the integrin ${\alpha}_v{\beta}_3$. General $^{68}Ga$-labeled cyclic RGD peptides was rapidly eliminated from the circulatory system by renal excretion because of its hydrophilic property. The purpose of this study was to develop a novel $^{68}Ga$-labeled cyclic RGD peptides, which could acquire enhanced PET tumor images with improved pharmacokinetics by adopting biphenyl group between chelator and RGD peptides. $^{68}Ga$-DOTA-2P-c(RGDyK) was demonstrated a 12% higher lipophilicity level than $^{68}Ga$-DOTA-c(RGDyK) as a reference compound. In the animal PET, $^{68}Ga$-DOTA-2P-c(RGDyK) represented relatively lower blood-clearance, and an increased signal to noise ratio compared to $^{68}Ga$-DOTA-c(RGDyK). From these perspective, $^{68}Ga$-DOTA-2P-c(RGDyK) could be a good candidate for in integrin ${\alpha}_v{\beta}_3$-expressed tumor imaging.

Management of Urinary Tract Infections in Children: A Survey of Pediatricians in Daegu City (대구지역 소아청소년과 의사들의 요로감염 관리 실태분석)

  • Lee, Sang Su;Kang, Seok Jeong;Lee, Jae Min;Cho, Min Hyun;Park, Yong Hoon
    • Childhood Kidney Diseases
    • /
    • v.16 no.2
    • /
    • pp.95-101
    • /
    • 2012
  • Purpose: Recently, many evidence-based guidelines for the management of urinary tract infection (UTI) have been developed because of the importance of proper management. However, there is a lack of data regarding how pediatricians manage UTIs in Korea. Therefore, we surveyed pediatricians to determine whether they manage UTIs in an appropriate manner. Methods: A postal questionnaire survey of 78 pediatricians practicing in Daegu city was performed. Subjects were asked about diagnosis, imaging studies, treatment, and prevention of UTIs. Results: Most of the respondents (94.8%) performed urinalysis to diagnose UTI in febrile children with an unknown fever focus. However, many preferred inaccurate collection methods, such as bagged urine collection, and did not obtain urine cultures. The most frequently performed imaging modality was renal-bladder ultrasonogram. Orally administered antibiotics were preferred unless admission was needed. After diagnosis of UTI, the pediatricians usually provided information to caregivers about the disease itself and supplementary treatment. Of the respondents, only 28.6% had their own guidelines for management of vesicoureteral reflux. Conclusion: Most pediatricians suspected UTI in febrile children with an unknown focus appropriately. Nevertheless, the fact that many pediatricians preferred inaccurate urine collection methods and did not perform sufficient imaging studies to detect associated abnormalities likely resulted in overtreatment due to false-positive diagnosis of UTI and a low probability of ruling out genitourinary anatomical problems. To improve the quality of management of UTI, pediatricians should follow scientific and evidence-based guidelines.

Small Animal PET Imaging with [$^{124}I$]FIAU for Herpes Simplex Virus Type 1 Thymidine Kinase Gene Expression in a Hepatoma Model (간암 동물 모델에서 2'-fluoro-2'-deoxy-1-${\beta}$-D-arabinofuranosyl-5-[$^{124}I$iodo-uracil ($[^{124}I]FIAU$) 소동물 PET 영상 연구)

  • Chae, Min-Jeong;Lee, Tae-Sup;Kim, June-Youp;Woo, Gwang-Sun;Jumg, Wee-Sup;Chun, Kwon-Soo;Kim, Jae-Hong;Lee, Ji-Sup;Ryu, Jin-Sook;Cheon, Gi-Jeong;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.235-245
    • /
    • 2008
  • Purpose: The HSV1-tk gene has been extensively studied as a type of reporter gene. In hepatocellular carcinoma (HCC), only a small proportion of patients are eligible for surgical resection and there is limitation in palliative options. Therefore, there is a need for the development of new treatment modalities and gene therapy is a leading candidate. In the present study, we investigated the usefulness of substrate, 2'-fluoro-2'-deoxy-1-${\beta}$-D-arabino-furanosyi-5-[$^{124/125}I$]iodo- uracil ([$I^{124/125}I$]FIAU) as a non-invasive imaging agent for HSV1-tk gene therapy in hepatoma model using small animal PET. Material and Methods: With the Morris hepatoma MCA cell line and MCA-tk cell line which was transduced with the HSV1-tk gene, in vitro uptake and correlation study between [$^{125}I$]FIAU uptake according to increasing numeric count of percentage of MCA-tk cell were performed. The biodistribution data and small animal PET images with [$^{124}I$]FIAU were obtained with Balb/c-nude mice bearing both MCA and MCA-tk tumors. Results:, Specific accumulation of [[$^{125}I$]FIAU was observed in MCA-tk cells but uptake was low in MCA cells. Uptake in MCA-tk cells was 15 times higher than that of MCA cells at 480 min. [$^{125}I$]FIAU uptake was linearly correlated (R2 =0.964, p =0.01) with increasing percentage of MCA-tk numeric cell count. Biodistribution results showed that [$^{125}I$]FIAU was mainly excreted via the renal system in the early phase. Ratios of MCA-tk tumor to blood acting were 10, 41, and 641 at 1 h, 4 h, and 24 h post-injection, respectively. The maximum ratio of MCA-tk to MCA tumor was 192.7 at 24 h. Ratios of MCA-tk tumor to liver were 13.8, 66.8, and 588.3 at 1 h, 4 h, and 24 h, respectively. On small animal PET, [$^{124}I$]FIAU accumulated in substantial higher levels in MCA-tk tumor and liver than MCA tumor. Conclusion: FIAU shows selective accumulation to HSV1-tk expressing hepatoma cell tumors with minimal uptake in normal liver. Therefore, radiolabelled FIAU is expected to be a useful substrate for non-invasive imaging of HSV1-tk gene therapy and therapeutic response monitoring of HCC.

Comparison for Glomerular Filtration Rate in Gamma Camera Systems Using Dynamic Renal Phantom System (동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교)

  • Kang, Chun Goo;Park, Hoon-Hee;Oh, Shin Hyun;Lee, Han Wool;Kim, Jung Yul;Oh, Joo Yung;Lee, Ju Young;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.3-9
    • /
    • 2013
  • Purpose: Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desire to evaluate the usefulness of nuclear medicine imaging. Materials and Methods: The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc-pertechnate$. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn ten times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Results: Under the same conditions infusion rate 40 mL/min fixed to adjust the pressure of the pump when the radiopharmaceuticals between 2-3 minutes in the most integrated in the kidney phantom was excreted inthe bladder. Glomerular filtration rate (GFR), respectively, by each device SYMBIA 1,091 mL/min, FORTE 1,232 mL/min, ARGUS 1,264 mL/min, INFINIA 1,302 mL/min in that there isno statistically significant difference was found, Tmax values and T1/2 values stars from all equipment with no statistically significant difference was found. CV values of the coefficient of variation less than 5% was found to be repeatable, and to 2.67% of the lowest SYMBIA appeared, INFINIA was the highest in the 4.86%. Conclusion: Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

Study on the Difference in Intake Rate by Kidney in Accordance with whether the Bladder is Shielded and Injection method in 99mTc-DMSA Renal Scan for Infants (소아 99mTc-DMSA renal scan에서 방광차폐유무와 방사성동위원소 주입방법에 따른 콩팥섭취율 차이에 관한 연구)

  • Park, Jeong Kyun;Cha, Jae Hoon;Kim, Kwang Hyun;An, Jong Ki;Hong, Da Young;Seong, Hyo Jin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.27-31
    • /
    • 2016
  • Purpose $^{99m}Tc-DMSA$ renal scan is a test for the comparison of the function by imaging the parenchyma of the kidneys by the cortex of a kidney and by computing the intake ratio of radiation by the left and right kidney. Since the distance between the kidneys and the bladder is not far given the bodily structure of an infant, the bladder is included in the examination domain. Research was carried out with the presumption that counts of bladder would impart an influence on the kidneys at the time of this renal scan. In consideration of the special feature that only a trace amount of a RI is injected in a pediatric examination, research on the method of injection was also carried out concurrently. Materials and Methods With 34 infants aged between 1 month to 12 months for whom a $^{99m}Tc-DMSA$ renal scan was implemented on the subjects, a Post IMAGE was acquired in accordance with the test time after having injected the same quantity of DMSA of 0.5mCi. Then, after having acquired an additional image by shielding the bladder by using a circular lead plate for comparison purposes, a comparison was made by illustrating the percentile of (Lt. Kidney counts + Rt. Kidney counts)/ Total counts, by drawing the same sized ROI (length of 55.2mm X width of 70.0mm). In addition, in the format of a 3-way stopcock, a Heparin cap and direct injection into the patient were performed in accordance with RI injection methods. The differences in the count changes in accordance with each of the methods were compared by injecting an additional 2cc of saline into the 3-way stopcock and Heparin cap. Results The image prior to shielding of the bladder displayed a kidney intake rate with a deviation of $70.9{\pm}3.18%$ while the image after the shielding of the bladder displayed a kidney intake rate with a deviation of $79.4{\pm}5.19%$, thereby showing approximately 6.5~8.5% of difference. In terms of the injection method, the method that used the 3-way form, a deviation of $68.9{\pm}2.80%$ prior to the shielding and a deviation of $78.1{\pm}5.14%$ after the shielding were displayed. In the method of using a Heparin cap, a deviation of $71.3{\pm}5.14%$ prior to the shielding and a deviation of $79.8{\pm}3.26%$ after the shielding were displayed. Lastly, in the method of direct injection into the patient, a deviation of $75.1{\pm}4.30%$ prior to the shielding and a deviation of $82.1{\pm}2.35%$ after the shielding were displayed, thereby illustrating differences in the kidney intake rates in the order of direct injection, a Heparin cap and the 3-way methods. Conclusion Since a substantially minute quantity of radiopharmaceuticals is injected for infants in comparison to adults, the cases of having shielded the bladder by removing radiation of the bladder displayed kidney intake rates that are improved from those of the cases of not having shielded the bladder. Although there are difficulties in securing blood vessels, it is deemed that the method of direct injection would be more helpful in acquisition of better images since it displays improved kidney intake rate in comparison to other methods.

  • PDF

Determination of Appropriate Sampling Frequency and Time of Multiple Blood Sampling Dual Exponential Method with $^{99m}Tc$-DTPA for Calculating GFR (사구체여과율 계산을 위한 $^{99m}Tc$-DTPA를 이용한 다중 채혈 이중지수법의 적정 채혈 횟수 및 시간의 선정)

  • Kim, Chung-Ho;O, Joo-Hyun;Chung, Yong-An;Yoo, Ie-Ryung;Sohn, Hyung-Sun;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.33-39
    • /
    • 2006
  • Purpose: To determine appropriate sampling frequency and time of multiple blood sampling dual exponential method with $^{99m}Tc$-DTPA for calculating glomerular filtration rate (GFR). Materials & Methods: Thirty four patients were included in this study. Three mCi of $^{99m}Tc$-DTPA was intravenously injected and blood sampling at 9 different times, 5ml each, were done. Using the radioactivity of serum, measured by gamma counter, the GFR was calculated using dual exponential method and corrected with the body surface area. Using spontaneously chosen 2 data points of serum radioactivity, 15 collections of 2-sample GFR were calculated. And 10 collections of 3-sample GFR and 12 collections of 4-sample GFR were also calculated. Using the 9-sample GFR as a reference value, degree of agreement was analyzed with Kendall's $\tau$ correlation coefficients, mean difference and standard deviation. Results: Although some of the 2-sample GFR showed high correlation coefficient, over or underestimation had evolved as the renal function change. The 10-120-240 min 3-sample GFR showed a high correlation coefficient (${\tau}=0.93$), minimal difference ($Mean{\pm}SD=-1.784{\pm}3.972$), and no over or underestimation as the renal function changed. The 4-sample GFR showed no better accuracy than the 3-sample GFR. Conclusions: In the wide spectrum of renal function, the 10-120-240 min 3-sample GFC could be the best choice for estimating the patients' renal function.

Preparation and biological evaluation of 99mTc tricarbonyl cysteine (테크네슘-99엠 트리카보닐 시스테인의 제조 및 생물학적 특성 평가)

  • Jang, Beom-su;Park, Kyung-bae;Yun, Hyo-in
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.1
    • /
    • pp.15-21
    • /
    • 2004
  • This paper describes the development of $^{99m}Tc$ tricarbonyl cysteine as potential renal function diagnostic radiopharmaceutical and evaluation of its biological characteristics using experimental animals. l-Cysteine was labeled efficiently with $^{99m}Tc$ tricarbonyl precursor $([^{99m}Tc(CO)_3(H_2O)_3)]^{+})$ under 30 min heating at ${75^{\circ}C}$. Labeling yield and stability were analyzed by high performance liquid chromatography (HPLC). The biodistribution property of $^{99m}Tc$ tricarbonyl cysteine in mice and its dynamic imaging profiles in rabbits were carried out. To investigate the excretion mechanism of $^{99m}Tc$ tricarbonyl cysteine, tubular transport inhibition test with probenecid was adopted. $^{99m}Tc$ tricarbonyl cysteine was obtained with a high labeling yield under the moderate condition. The results of biodistribution experiments of $^{99m}Tc$ tricarbonyl cysteine in ICR mice at 3 and 90 min provided that $^{99m}Tc$ tricarbonyl cysteine was very highly accumulated in the kidney and bladder, thereby almost 99% of $^{99m}Tc$ tricarbonyl cysteine was excreted within 90 min post injection. The same results were confirmed by the whole body dynamic images for 30 minutes and static images in rabbits at given time intervals after injection. Renogram of $^{99m}Tc$ tricarbonyl cysteine in rabbits showed that its $T_{max}$ and $T_{1/2}$ of $^{99m}Tc$ tricarbonyl cysteine were $2.33{\pm}0.56$ and $4.30{\pm}0.79$ min, respectively. The $T_{max}$ of $^{99m}Tc$ tricarbonyl cysteine with probenecid pretreatment was $2.30{\pm}0.17$ min, whereas $T_{1/2}$ of that with probenecid pretreatment was $17.0{\pm}32.47$ min. $T_{1/2}$ of $^{99m}Tc$ tricarbonyl cysteine with probenecid pretreatment was significantly different, as compared to the result without probenecid (p<0.0001). The results showed that the excretion of $^{99m}Tc$ tricarbonyl cysteine was extremely affected by probenecid. Therefore, $^{99m}Tc$ tricarbonyl cysteine was rapidly excreted from the kidney principally by the tubular secretion.

Assessment of Systemic Arterial Thromboembolism with Multi-Slice Spiral CT in a Dog (개에서 다중나선형 CT촬영에 의한 동맥혈전색전증의 평가)

  • Shin, Seung-Ho;Lee, Ki-Chang
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.208-213
    • /
    • 2007
  • A 15 kg 6-year-old intact male Jindo dog with a history of a respiratory distress, hindlimb paralysis with necrosed skin of dorsal digit for three weeks was referred to Animal Medical Center, Chonbuk National University. Heartworm infection was identified by kit examination. In plain thoracic radiographs, dilated pulmonary arteries reverse D sign and focal interstitial pattern was compatible with heartworm infection and possible pulmonary thromboembolism. Abdominal radiographs showed poor serosal detail indicating fluid accumulation within peritoneal cavity. No evidence of musculoskeletal abnormalities was found. Ultrasonography presented focal wedge-shaped hyperechogenecity on the both poles of left kidney, weak or absent pulse on the distal to the external iliac artery as well as ascites and irregular liver margin. Multi-organ failure was strongly supposed by blood profile including leukocytosis, anemia, hemoglobinuria bililubinemia, hypoalbuminemia, imbalance of electrolytes, and increased hepatic and renal function values. Interestingly, the glucose level is remarkably lower in pelvic limb compared to thoracic limb. Suspected pulmonary thromboembolism, renal infarction and femoral arterial embolization causing hindlimb paralysis and dermatic necrosis were confirmed by 3D reconstructed CT imaging. Prior to taking a consideration of euthanasia, interventional radiology was experimentally attempted but failed due to not recovered from general anesthesia. Early and accurate diagnosis of thromboembolism is valuable and 3D reconstructed CT images might be very useful to show the correct way to treat effectively.

Pharmacokinetics and Bio-distribution of New Gd-complexes of DTPA-bis (amide) (L3) in a Rat Model (쥐를 이용한 새로운 가돌리늄 조영제 Gd-DTPA-bis(amide)(L3)의 약동학 및 생체내 분포 특성에 대한 연구)

  • Yan, Gen;Wu, Renhua;Chang, Yongmin;Kang, Duksik
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.259-266
    • /
    • 2013
  • Purpose : To investigate the blood pharmacokinetics and bio-distribution of DTPA-bis-amide (L3) Gd(III) complexes. Materials and Methods: The pharmacokinetics and bio-distribution of Gd $(L3)(H_2O){\cdot}nH_2O$ were investigated in Sprague-Dawley rats after intravenous administration at a dose of 0.1 mmol Gd/kg. The Gd content in the blood, various tissues, and organs was determined by ICP-AES. Blood pharmacokinetic parameters were calculated using a two-compartment model. Results: The half-lives of ${\alpha}$ phase and ${\beta}$ phase Gd $(L3)(H_2O){\cdot}nH_2O$ were $2.286{\pm}0.11$ min and $146.1{\pm}7.5$ min, respectively. The bio-distribution properties reveal that the complex is mainly excreted by the renal pathway, and possibly excreted by the hepatobiliary route. The concentration ratio of Gd (III) was significantly higher in the liver and spleen than in other organs, and small amounts of Gd (III) ion were detected in the blood or other tissues of rats only after 7 days of intravenous administration. Conclusion: The MRI contrast agent Gd $(L3)(H_2O){\cdot}nH_2O$ provides prolonged blood pool retention in the circulation and then clears rapidly with minimal accumulation of Gd(III) ions. The synthesis of gadolinium complexes with well-balanced lipophilicity and hydrophilicity shows promise for their further development as blood pool MRI contrast agents.

A Case of Severe Hypercalcemia Causing Acute Kidney Injury: An Unusual Presentation of Acute Lymphoblastic Leukemia

  • Hyun, Hye Sun;Park, Peong Gang;Kim, Jae Choon;Hong, Kyun Taek;Kang, Hyoung Jin;Park, Kyung Duk;Shin, Hee Young;Kang, Hee Gyung;Ha, Il Soo;Cheong, Hae Il
    • Childhood Kidney Diseases
    • /
    • v.21 no.1
    • /
    • pp.21-25
    • /
    • 2017
  • Severe hypercalcemia is rarely encountered in children, even though serum calcium concentrations above 15-16 mg/dL could be life-threatening. We present a patient having severe hypercalcemia and azotemia. A 14-year-old boy with no significant past medical history was referred to our hospital with hypercalcemia and azotemia. Laboratory and imaging studies excluded hyperparathyroidism and solid tumor. Other laboratory findings including a peripheral blood profile were unremarkable. His hypercalcemia was not improved with massive hydration, diuretics, or even hemodialysis, but noticeably reversed with administration of calcitonin. A bone marrow biopsy performed to rule out the possibility of hematological malignancy revealed acute lymphoblastic leukemia. His hypercalcemia and azotemia resolved shortly after initiation of induction chemotherapy. Results in this patient indicate that a hematological malignancy could present with severe hypercalcemia even though blast cells have not appeared in the peripheral blood. Therefore, extensive evaluation to determine the cause of hypercalcemia is necessary. Additionally, appropriate treatment, viz., hydration or administration of calcitonin is important to prevent complications of severe hypercalcemia, including renal failure and nephrocalcinosis.