• 제목/요약/키워드: Removal rate.

검색결과 3,891건 처리시간 0.031초

Crosslinking of $\beta$-Cyclodextrin on Cholesterol Removal from Milk

  • Kim, S.H.;Ahn, J.;Kwak, H.S.
    • Archives of Pharmacal Research
    • /
    • 제27권11호
    • /
    • pp.1183-1187
    • /
    • 2004
  • This study was designed to develop crosslinking of $\beta$-cyclodextrin ($\beta$-CD), and determine the optimum conditions of different factors (mixing time, mixing temperature, and mixing speed) on cholesterol reduction from milk. Crosslinked $\beta$-CD was prepared with epichlorohydrin. When milk was treated with different conditions, the cholesterol removal rate was in the range of 79.4 to 83.3% with 1 % crosslinked $\beta$-CD addition, which were not significantly different among treatments. After cholesterol removal from milk, the used crosslinked $\beta$-CD was washed for cholesterol dissociation and reused. For recycling study, the cholesterol removal rate in first trial was 81.8%, which was mostly same as that using new crosslinked $\beta$-CD. With five trials repeatedly using the same sample, the mean cholesterol removal rate was 81.2%. The present study indicated that the optimum conditions on cholesterol removal using crosslinked $\beta$-CD were 10 min mixing with 400 rpm speed at $5^{\circ}C$ with about 80% cholesterol removal. In addition, crosslinked $\beta$-CD resulted in the effective recycling efficiency almost 100%.

팔당호 연안대 초지생태계에서 낙엽 구성성분의 유실률 VI. Cu, Fe 및 Zn (The Removal Rates of the Constituents of Litters in the Littoral Grassland Ecosystems in the Lake Paldangho VI. Cu, Fe and Zn)

  • 윤신선;이인숙;장남기
    • 아시안잔디학회지
    • /
    • 제10권4호
    • /
    • pp.297-304
    • /
    • 1996
  • The investigation was performed to reveal the removal rate of metal constituents of litters in a Phragmites communis Miseanthus sacchariflorus, Typha angastata and Seirpas tabernaemontani grasslands in the lake Paldangho. The removal rates of metal constituents are determined by the mathematical models. The removal rates and time required to decay up to a percentage of each metal constituent were calculated using these model. The removal rates of Cu, Fe and Zn were 0.61, 0.58 and 0.79 in Phragmites communis 0.39, 0.47 and 0.68 in Miseanthus saccharflorus; 0.26, 0.09 and 0.23 in Typha angustata: 0.56, 0.27 and 0.67 in Seirpus tabernaemontani respectively. The periods required to reach half time to the stedy state of the removal and accumulation for Cu, Fe and Zn were 1,13,1.19 and 0.79 years in Phragmites communis; 1.79, 1.49 and 1.02 years in Miscanthus sacchariflorus; 2.70, 7.43 and 2.96 years in Typha angustata ; 1.23, 2.58 and 1.04 years in Scirqus tabernaemontani, re-spectively. Key words: Phragmites communis, Miscanthus sacchariflorus, Typha angustata and Scirpus tabernaemontani, lake Paldangho, Removal rate, Cupper, Iron, Zinc.

  • PDF

하수중의 질소.인 제거를 위한 $A^2$/O공정의 적용 (Application of $A^2$/O Process for Removal of Nitrogen and Phosphorus in Sewage)

  • 안철우;박진식;문추연
    • 한국환경보건학회지
    • /
    • 제26권4호
    • /
    • pp.9-14
    • /
    • 2000
  • In this study, the removal efficiencies of organics, nitrogens and phosphorus from municipal wastewater using $A^2$/O process were investigated. BO $D_{5}$ removal efficiencies were indicated 95% and 94% with HRT of 12 hr and 10 hr, respectively. CO $D_{Cr}$ average removal efficiency and concentration of effluent were indicated 87% and 34mg/$\ell$. SS average removal efficiency and concentration of effluent were indicated 93% and 4~17mg/$\ell$. T-N removal efficiency and concentration of effluent were shown as 60~80% and below 15mg/$\ell$. In aerobic basin, removal efficiency of N $H_4$-N was shown over 97% with N $H_4$-N volume load 0.16kg N $H_4$-N/㎥.d and in anoxic basin, denitrification efficiency was indicated over 80% with return sludge rate 0.5Q and internal recirculation rate 2.5Q. Removal efficiency and effluent concentration of phosphorus were shown over 80% and below 2 mg/$\ell$ with return sludge rate 0.5Q.Q.

  • PDF

UV-OXIDATIVE TREATMENT OF BIO-REFRACTORY ORGANIC HALOGENS IN LEACHATE: Comparison Between UV/O3, UV/H2O2, and UV/H2O2/O3 Processes

  • Qureshi, Tahir Imran;Kim, Young-Ju
    • Environmental Engineering Research
    • /
    • 제11권2호
    • /
    • pp.84-90
    • /
    • 2006
  • UV-catalytic oxidation technique was applied for the treatment of bio-refractory character of the leachate, which is generally present in the form of adsorbable organic halogens (AOX). Destruction of AOX was likely to be governed by pH adjustment, quantitative measurement of oxidants, and the selection of oxidation model type. Peroxide induced degradation ($UV/H_2O_2$) facilitated the chemical oxidation of organic halides in acidic medium, however, the system showed least AOX removal efficiency than the other two systems. Increased dosage of hydrogen peroxide (from 0.5 time to 1.0 time concentration) even did not contribute to a significant increase in the removal rate of AOX. In ozone induced degradation system ($UV/O_3$), alkaline medium (pH 10) favored the removal of AOX and the removal rate was found 11% higher than the rate at pH 3. Since efficiency of the $UV/O_3$ increases with the increase of pH, therefore, more OH-radicals were available for the destruction of organic halides. UV-light with the combination of both ozone and hydrogen peroxide ($UV/H_2O_2$ 0.5 time/$O_3$ 25 mg/min) showed the highest removal rate of AOX and the removal efficiency was found 26% higher than the removal efficiency of $UV/O_3$. The system $UV/H2O_2/O_3$ got the economic preference over the other two systems since lower dose of hydrogen peroxide and relatively shorter reaction time were found enough to get the highest AOX removal rate.

유입부하가 DEPHANOX 및 Modified-DEPHANOX 공정에 미치는 영향 (Effect of Loading Rate in the Operation of DEPHANOX and Modified-DEPHANOX Processes)

  • 류홍덕;민경국;이상일
    • 한국물환경학회지
    • /
    • 제20권1호
    • /
    • pp.24-31
    • /
    • 2004
  • This study was initiated to evaluate the efficiencies of DEPHANOX and Modified-DEPHANOX, which were devoloped to enhance nitrogen removal efficiency in municipal wastewater treatment. In the results, removal efficiency of organic matters was not affected much by increased loading rate of organic matters which is contained in influent. The nitrogen removal efficiencies according to the loading rate of influent TN was decreased drastically in conditions of over $0.2kg/m^3{\cdot}day$, which is T-N loading rate, and the DEPHANOX process was affected more sensitively than the M-DEPHANOX was. When the temperature was altered from $25^{\circ}C$ to $16^{\circ}C$ at HRT 6hrs, the removal efficiency of ammonia nitrogen was still over 90% and it was concluded that both DEPHANOX and M-DEPHANOX were strong enough to endure temperature variation. Moreover, both processes showed over 90% in ammonia removal efficiencies in over HRT 5hrs, so it was concluded that they were strong in HRT variation. M-DEPHANOX process showed a higher value than DEPHANOX did in T-N removal efficiency to the extent of 4~21 %, which resulted from differency of denitrification rates and the biosorption efficiency of organic matter in both processes. In the condition of HRT less than 4hrs, concentrations of ammonia nitrogen contained in effluents and nitrification reactors, might be sensitively affected by biosorption efficiency of organic matters in first separation tank. In the effect of effluent nitrate concentration in phosphorus removal, the more effluent nitrate concentration was decreased, the more phosphorus removal efficiency was increased. This result is related to the decrease of concentration of effluent nitrate which resulted from nitrification inhibition by decreased HRT.

수계 내 조류 제거를 위한 전기응집 운전 특성 평가 (Evaluation of Operation Parameters for the Removal of Algae by Electro-Coagulation)

  • 정권;김도군;김석구;김원재;고석오
    • 한국물환경학회지
    • /
    • 제31권2호
    • /
    • pp.94-102
    • /
    • 2015
  • Electro-coagulation experiments were conducted with aluminum (Al) or iron (Fe) electrode in order to determine the optimal electrode material and operation conditions for algae removal. Al electrode showed higher removal rate of algae than Fe electrode because Al flocs have positive surface charges which electrostatically attract algae species having negative surface charges. Removal rate of algae and total phosphorous (T-P) was increased as current density and electrode area increases. It was also found that initial pH with neutral range was optimum for T-P removal by electro-coagulation. Bench-scale continuous flow experiments consisted of electro-coagulation reactor, agitation tank and settling tank were conducted. In electro-coagulation reactor, a large fraction of Al flocs were distributed to scum layer, due to the gas bubbles generated by electrolysis reaction. In agitation tank, most of Al flocs were settled and the optimal mixing intensity was found to be 50 rpm to achieve good settleability. The removal rate of algae was about 90-95%. Additionally, the removal rate of the T-P and COD was observed to be $73.8{\pm}8.0%$ and $75.0{\pm}3.8%$, respectively. Meanwhile, the removal rate of total nitrogen (T-N) was relatively low at only 24%.

쌀과 배추의 세척 및 가열에 의한 유기인계 농약의 제거 효과 (Organophosphorus pesticides removal effect in rice and Korean Cabbages by Washing and Coo]ling)

  • 제갈성아;한영선;김성애
    • 한국식품조리과학회지
    • /
    • 제16권5호
    • /
    • pp.410-415
    • /
    • 2000
  • 본 실험의 목적은 우리나라 상용식품인 쌀과 배추의 세척과 가열에 의한 유기인계 농약의 제거효과를 보기 위한 것으로 유기인계 농약 중 diazinon, fenithrithion, phenthoate, EPN 인위적으로 부착하여 세척과 가열과정의 변화에 의한 저감 효과를 실험한 결과는 다음과 같다. 1. 쌀의 세척에 의한 농약의 제거율은 15.5∼35.4%이었으며, 제거효과는 세척회수보다 물의 양의 영향력이 더 높았다. 2. 쌀을 세척한 후 취반과정을 거치면 농약의 제거율은 72.1∼77.8%이었다. 3. 배추의 세척, 가열과정에 의한 농약의 제거율은 각각 18.4∼41.0%, 22.8∼82.7%이었다. 4. 배추는 쌀과 같이 세척과 가열시 물의 양이 많을수록 제거효과가 높았다. 5. 우리나라의 요리 방법인 나물 무침시 배추를 삶아서 꼭 짜서 수분이 제거되면 농약의 잔존량은 더욱 낮아진다.

  • PDF

Optimized cultivation of Ettlia sp. YC001 in eutrophic pond water for nutrient removal and biomass production

  • Oh, Hyung-Seok;Ahn, Chi-Yong;Srivastava, Ankita;Oh, Hee-Mock
    • ALGAE
    • /
    • 제33권4호
    • /
    • pp.319-327
    • /
    • 2018
  • Ettlia sp. YC001, a highly settleable and productive microalga, was shown to be effective in removing nutrients and capturing suspended solids from eutrophic pond water. The optimum conditions for the Ettlia sp. YC001 cultivation were investigated using water from a landscape pond. The pond water was supplemented with different N : P ratios by weight, and the biomass production and nutrient removal compared in batch cultures. The maximum removal rate of N and P was with an N : P ratio of 16 : 1. Plus, the turbidity dropped to near zero within 4 days. Meanwhile, chemostat cultivation showed that the biomass productivity and nutrient removal rate increased when increasing the dilution rate, where a dilution rate of $0.9d^{-1}$ showed the highest N and P removal rate at $32.4mg\;L^{-1}\;d^{-1}$ and $1.83mg\;L^{-1}\;d^{-1}$, respectively, and highest biomass and lipid productivity at $0.432g\;L^{-1}\;d^{-1}$ and $67.8mg\;L^{-1}\;d^{-1}$, respectively. The turbidity was also reduced by 98% in the chemostat cultivation. Moreover, auto-flocculation and pH were closely connected to the turbidity removal. As a result, this study identified the optimal N : P ratio for small pond water treatment using an Ettlia sp. YC001, while also establishing the optimal conditions for nutrient removal, turbidity reduction, and biomass production.

축산폐수 전처리를 위한 암모니아 탈기공정의 운전조건이 암모니아 제거에 미치는 영향 (Effect of Operating Condition of Stripping Process on Ammonia Removal for Pre-treatment of Swine Wastewater)

  • 황규대;조영무
    • 한국물환경학회지
    • /
    • 제20권1호
    • /
    • pp.86-92
    • /
    • 2004
  • Lab-scale experiments have been carried out to investigate ammonia stripping with a modified spray tower for removing ammonia nitrogen from swine wastewater. The operating conditions such as initial pH, temperature, air flow, hole size of distributor determining the diameter of water drops, and influent solids concentration were closely examined focusing on removal efficiency of ammonia. As a result of the experiment, in order to achieve high rate of ammonia removal by the air stripping system, the air flow rate must be supplied at high rate with sufficiently high initial pH, temperature. The optimum operating condition to meet the residual ammonia concentration of 300 mg/L was the initial pH of 11.0 at $35^{\circ}C$ with the air flow rate of 20 L/min. It also showed that the smaller hole size is, the higher removal rate of ammonia is expected. However, when used a small sized distributor (2 mm), the flooding problem at the upper column occurred due to clogging of the hole. With regard to the influent solids concentration, it was showed that the lower concentration of solids, the higher removal rate of ammonia. The removal of particulate materials in influent led to improve the removal efficiency of ammonia, rather than to control the operating condition including initial pH, temperature, and air flow. The empirical correlation between KLa and operating parameters would be driven as, $K_{La}=(0.0003T-0.0047){\cdot}G^{0.3926}{\cdot}L^{-0.5169}{\cdot}C^{-0. 1849}$. The calculated $K_{La}$ from proposed formula can be used effectively to estimate the optimum reaction time and to calculate the volume of modified spray tower system.

산화막 CMP에서 세리아 입자의 패드 표면누적과 재료제거 관계 (Correlation between Ceria abrasive accumulation on pad surface and Material Removal in Oxide CMP)

  • 김영진;박범영;정해도
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.118-118
    • /
    • 2008
  • The oxide CMP has been applied to interlayer dielectric(ILD) and shallow trench isolation (STI) in chip fabrication. Recently the slurry used in oxide CMP being changed from silica slurry to ceria (cerium dioxide) slurry particularly in STI CMP, because the material selectivity of ceria slurry is better than material selectivity of silica slurry. Moreover, the ceria slurry has good a planarization efficiency, compared with silica slurry. However ceria abrasives make a material removal rate too high at the region of wafer center. Then we focuses on why profile of material removal rate is convex. The material removal rate sharply increased to 3216 $\AA$/min by $4^{th}$ run without conditioning. After $4^{th}$ run, material removal rate converged. Furthermore, profile became more convex during 12 run. And average material removal rate decreased when conditioning process is added to end of CMP process. This is due to polishing mechanism of ceria. Then the ceria abrasive remains at the pad, in particular remains more at wafer center contacted region of pad. The field emission scanning electron microscopy (FE-SEM) images showed that the pad sample in the wafer center region has a more ceria abrasive than in wafer outer region. The energy dispersive X-ray spectrometer (EDX) verified the result that ceria abrasive is deposited and more at the region of wafer center. Therefore, this result may be expected as ceria abrasives on pad surface causing the convex profile of material removal rate.

  • PDF