Treatment of oily wastewater from cold-rolling mill through coagulation and integrated membrane processes

  • Cheng, Xue-Ni;Gong, Yan-Wen
    • Environmental Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.159-163
    • /
    • 2018
  • The feasibility of applying coagulation-integrated microfiltration (MF) as a pretreatment for an ultrafiltration (UF) feed in oily wastewater treatment was investigated. The effects of different coagulants on oil removal rates from wastewater were studied. The maximum oil removal rate of 82% was obtained after coagulation with 130 mg/L of polyaluminium chloride (PAC). UF flux reached $95L/(m^2{\cdot}h)$ with coagulation-integrated MF as pretreatment. This value was 2.5 times higher than that flux obtained without pretreatment. The value of UF flux increased as the transmembrane pressure (TMP) and cross-flow velocity (CFV) of the UF module increased. UF flux gradually increased when TMP and CFV exceeded 0.4 MPa and 3 m/s, respectively, because of concentration polarization and membrane fouling stabilization. Chemical oxygen demand reduction and oil removal rate reached 95.2% and 98.5%, respectively, during integrated membrane processing with a PAC concentration of 130 mg/L, TMP of 0.4 MPa, and CFV of 3 m/s for UF. In addition, sequentially cleaning the fouling membrane with NaOH and $HNO_3$ aqueous solutions caused UF flux to recover to 90%. These encouraging results suggested that the hybrid integrated membrane process-based coagulation and MF + UF are effective approaches for oily wastewater treatment.

Selection of Surfactant and Operation Scheme for Improved Efficiency of In-situ Soil Flushing Process (원위치 토양세척 공정의 효율향상을 위한 세제선정과 운전기법)

  • Son, Bong-Ho;Lim, Bong-Su;Oa, Seong-Wook;Lee, Byung-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.824-830
    • /
    • 2006
  • Several tests were conducted to optimize the design parameters of ln-situ soil flushing processes for diesel contaminated soil. According to the batch extraction test for three anionic surfactants evaluation, Calgonit limiting bubble occurrence was selected for its higher oil cleaning efficiency. After optimum surfactant selection, there were many sets of column flushing test. Over 70% of BTEX was removed in this surfactant dose with 400% of soil volume. In the case of no surfactant addition flushing in column, so called "blank flushing test", BTEX removal rate was 64%. But when we reused the effluent for the cleaning solution, the removal rate was decreased to 46.9%. This result showed reabsorption of oil occurred on the soil. With the addition of Calgonit solution to the diesel contaminated column, BTEX was removed up to 98.9% during the first flushing and 99.4% for the second recirculation flushing. In microcosm tests, diesel contaminated soils were cleaned by both surfactant flushing and biological activities. In anoxic condition, nitrate was used as an electron acceptor while the surfactant and the oil were used an electron donor. BTEX removal efficiency could be achieved up to 80% by biological degradation.

Destruction and Removal of PCBs in Waste Transformer Oil by a Chemical Dechlorination Process

  • Ryoo, Keon-Sang;Byun, Sang-Hyuk;Choi, Jong-Ha;Hong, Yong-Pyo;Ryu, Young-Tae;Song, Jae-Seol;Lee, Dong-Suk;Lee, Hwa-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.4
    • /
    • pp.520-528
    • /
    • 2007
  • A practical and efficient disposal of PCBs (polychlorinated biphenyls) in waste transformer oil by a chemical dechlorination process has been reported. The transformer oil containing commercial PCB mixtures (Aroclor 1242, 1254 and 1260) was treated by the required amounts of PEG 600 (polyethylene glycol 600), potassium hydroxide (KOH) and aluminum (Al), along with different reaction temperatures and times. The reaction of PEG with PCBs under basic condition produces arylpolyglycols, the products of nucleophilic aromatic substitution. The relative efficiencies of PCB treatment process were assessed in terms of destruction and removal efficiency (DRE, %). Under the experimental conditions of PEG600/KOH/Al/100 oC/2hr, average DRE of PCBs was approximately 78%, showing completely removal of PCBs containing 7-9 chlorines on two rings of biphenyl which appear later than PCB no. 183 (2,2',3,4,4',5',6-heptaCB) in retention time of GC/ECD. However, when increasing the reaction temperature and time to 150 oC and 240 min, average DRE of PCBs including the most toxic PCBs (PCB no. 77, 105, 118, 123 and 169) in PCB family reached 99.99% or better, with the exception of PCB no. 5 and 8 (2,3-diCB and 2,4'-diCB). In studying the reaction of PEG with PCBs, it confirmed that the process led to less chlorinated PCBs through a stepwise process with the successive elimination of chlorines. The process also permits complete recovery of treated transformer oil through simple segregating procedures.

A Study on the Nondimensional Analysis for the Recovery Rate of Oil Using a Belt Type Skimmer (벨트식 유회수기의 유회수율 데이터의 무차원화 과정에 관한 연구)

  • Yoon Kyunghwan
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.2 no.1
    • /
    • pp.34-39
    • /
    • 1999
  • Removal of spilled oil over the sea and the river has become one of the urgent problems in these days. Removing oil using mechanical devices by adhesion method is known to be closely related with the problem of estimating the thickness of film remaining on the surface of solid withdrawn from a quiescent liquid. In the present study a series of experimental results are compared with the analytic estimation for the thickness of film remaining on the solid surface using non-dimensional analysis. For the case of pure water both results show the remarkable agreement. However, discrepancy has been found for the case of Bunker C oil and diesel oil. The analytic estimation over-predicts the experimental value for the case of Bunker C oil and under-predicts it for the case of diesel oil. Further study is required to investigate the real situation including a contact angle and the property difference between oil and water.

  • PDF

Treatability Study on the Remediation Groundwater Contaminated by TPH Cr6+ : Lab-Scale Experiment (TPH와 6가 크롬으로 오염된 지하수 처리를 위한 실내 실험)

  • Lee, Gyu-Beom;Chang, Yoon-Young
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.3
    • /
    • pp.332-345
    • /
    • 2019
  • The purpose of the study is to evaluate the treatability of contaminated groundwater with TPH and (or) $Cr^{6+}$. Laboratory scale tests were performed for oil/water separation, dissolved air flotation (DAF), coagulation and precipitation, and filtration with sand and activated carbon respectively. Two times of oil/water separation tests for total 40 minutes of separation or separating time shows 90.2 % of TPH removal rate. In case of DAF test for high TPH sample, the TPH removal rates were not varied significantly by the variation of microbubble size. However, tests for low TPH samples show that TPH removal rate increases as microbubbles are smaller. When coagulant was added to sample for DAF test, TPH removal rate was increased 12.3 %. SS removal rate by DAF was 97.9 % at $16-40{\mu}m$ and it was increased as the size of microbubble is reduced. Tests for coagulation and precipitation were performed to evaluate the removal of $Cr^{6+}$ in groundwater. The increase of $FeSO_4$ dosage increased $Cr^{6+}$ removal rate in the coagulation and precipitation process. As the amount of activated carbon in the filter media increased TPH removal rate in the filtration process. SS removal rate by the filtration was 96.7 % similar to the results of DAF process tests. The filtration process treats TPH and SS. Best design parameters are determined as the size of sand is $425-850{\mu}m$ and the ratio of activated carbon and sand is 50:50.

Degradation of Fat, Oil, and Grease (FOGs) by Lipase-Producing Bacterium Pseudomonas sp. Strain D2D3

  • Shon, Ho-Kyong;Tian, Dan;Kwon, Dae-Young;Jin, Chang-Suk;Lee, Tae-Jong;Chung, Wook-Jin
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.4
    • /
    • pp.583-591
    • /
    • 2002
  • Biodegradation of fat, oil, and grease (FOGs) plays an Important role in wastewater management and water pollution control. However, many industrial food-processing and food restaurants generate FOG-containing waste waters for which there Is no acceptable technology for their pretreatment. To solve these problems, this study evaluated the feasibility of effective FOG-degrading microorganisms on the biodegradation of olive oil and FOG-containing wastewater. Twenty-two strains capable of degrading FOGs were isolated from five FOG-contaminated sites for the evaluation of their FOG degradation capabilities. Among twenty-two strains tested, the lipase-producing Pseudomonas sp. strain D2D3 was selected for actual FOG wastewater treatment. Its biodegradability was performed at 3$0^{\circ}C$ and pH 8. The extent of FOG removal efficiency was varied for each FOG tested, being the highest for olive oil and animal fat (94.5% and 94.4%), and the lowest for safflower oil (62%). The addition of organic nitrogen sources such as yeast extract, soytone, and peptone enhanced the removal efficiency of FOGs, but the addition of the inorganic nitrogen nutrients such as $NH_4$Cl and $(NH_4)_2SO_4$ did not increase. The $KH_2PO_4$ sources in 0.25% to 0.5% concentrations showed more than 90% degradability. As a result, the main pathway for the oxidation of fatty acids results in the removal of two carbon atoms as acetyl-CoA with each reaction sequence: $\beta$-oxidation. Its lipase activity showed 38.5 U/g DCW using the optimal media after 9 h. Real wastewater and FOGs were used for determining the removal efficiency by using Pseudomonas sp. strain D2D3 bioadditive. The degradation by Pseudomonas sp. strain D2D3 was 41% higher than that of the naturally occurring bacteria. This result indicated that the use of isolated Pseudomonas sp. strain D2D3 in a bioaugmentating grease trap or other processes might possibly be sufficient to acclimate biological processes for degrading FOGs.

Development of Micro-chip Removal Equipment Using Bubble (버블을 이용한 미세칩 제거장치의 개발)

  • Choi, Sung-Yun;Kwon, Dae-Gyu;Lee, Sea-Han;Park, Tae-hyun;Wang, Duck Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.10
    • /
    • pp.88-94
    • /
    • 2021
  • Machining operations require the removal of chips to keep the water-soluble cutting oil clean and fresh throughout the operation time. Water-soluble cutting oil for metal processing is diluted using a 3-8% solution in water which is generally replaced every three to six months. This study aims to develop multiple purification devices to efficiently remove fine contaminating particles from water-soluble cutting oil. The 2D concept designs were created using AutoCAD. The designs were drawn using the 3D modelling feature of CATIA. Flow analysis was performed in a bubble purifier using Ansys computational fluid dynamics (CFD). This analysis has aided in improving the design and structure of the device to create the final prototype. Experiments were conducted to check the prototype's performance. Comparisons of the effects of each process variable on the experiment was carried out using ANOVA.

A Fundamental Study on the Application of Cast for Removal of VOCs Produced in the Oil-contaminated Soil (유류오염 토양에서 발생되는 VOCs 제거를 위한 분변토의 활용 가능성에 관한 기초연구)

  • Son, Hee-Jeong;Chun, Mi-Hee;Kim, Chul
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.5
    • /
    • pp.456-461
    • /
    • 2007
  • This study was carried out two point view that reuse of sludge and adsorption of benzene, toluene and o-xylene of VOCs in cast, carbonized cast and activated carbon. The cation exchange capacity of cast and carbonized cast were 59.2, 112 meq/100g, respectively. The specific surface were 560, $800m^2/g$, respectively. The average removal rates of benzene by 50g cast of 50% hydrous cast, anhydrous cast, carbonized cast, activated carbon were 15.0, 41.2, 88.2, 99.4% in 60min of retention time. The average removal efficiency of toluene by 50 g cast of 50% hydrous cast, anhydrous cast, carbonized cast, activated carbon were 12.5, 34.2, 88.2, 99.5% in 60 min of retention time. The average removal rates of o-xylene 50 g cast of 50% hydrous cast, anhydrous cast, carbonized cast, activated carbon were 8.8, 28.5, 84.8, 98.1% in 60min of retention time. The adsorption efficiency of test absorbent was in order of Activated Carbon > Carbonized Cast > Cast.

Effect of Organic Loading Rate on the Performance of Anaerobic Hybrid Reactor (유기물 부하가 Anaerobic Hybrid Reactor 운전효율에 미치는 영향)

  • Shin, Chang-Ha;Oh, Dae-Yang;Kim, Tae-Hoon;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.4
    • /
    • pp.497-502
    • /
    • 2012
  • Anaerobic Digestion Process is evaluated as efficient wastewater treatment process with the removal of high concentrations of organic waste and production of biogas. This study was performed using hybrid anaerobic hybrid reactor (AHR) which consists of anaerobic sludge blanket (UASB) and biofilm-coated filter media was applied for Palm Oil Mill Effluent (POME) for 80 days to know optimum removal efficiency and production of biogas by comparing each part which divided changing Organic Loading Rate (OLR). As a result of this study, the removal efficiency was 90.4 % when the organic loading rate of influent was 15 kg COD/$m^3$/day. Since organic loading rate was up to 20 kg COD/$m^3$/day, the removal rate declined 80.7%. Over loading of influent caused sludge expansion and overproduction of microorganism. Amount of biogas was collected 82.3 L/day and pH was remained 6.9 constantly with balance of alkalinity.