• Title/Summary/Keyword: Removal of Needle

Search Result 96, Processing Time 0.026 seconds

Intraosseous anesthesia using a computer-controlled system during non-surgical periodontal therapy (root planing): Two case reports

  • Han, Keumah;Kim, Jongbin
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.18 no.1
    • /
    • pp.65-69
    • /
    • 2018
  • Local anesthesia is administered to control pain, but it may induce fear and anxiety. Root planing is a non-surgical periodontal therapy; however, when it is performed in an extensive manner, some tissue removal is inevitable. Notably, this removal may be so painful that local anesthesia is required to be administered to the area scheduled for the treatment. Although patients tend to accept root planing easily, they frequently express a fear of local anesthesia. Intraosseous anesthesia (IA) is an intraosseous injection technique, whereby local anesthetic is injected into the cancellous bone supporting the teeth. A computer-controlled IA system (CIAS) exhibits multiple benefits, such as less painful anesthesia, reduced soft tissue numbness, and the provision of palatal or lingual, as well as buccal, anesthesia via single needle penetration. In this report, we present two cases of root planing that were performed under local anesthesia, using a CIAS.

Removal of Broken Instruments in Soft Tissue at Mandibular Area Using a Dental Mini C-arm: Case Reports (치과용 소형 C자형 투시장치를 이용한 하악 연조직에 위치한 부러진 기구의 제거: 증례보고)

  • Park, Sung-Soo;Yang, Hoon-Joo;Hwang, Soon-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.6
    • /
    • pp.567-572
    • /
    • 2010
  • Intraoperative breakage of instruments can be occurred unexpectedly. To prevent damage of neighboring important anatomic structures and consequent complications, broken instruments should be removed as soon as possible. There have been several methods to remove broken instruments. One of them is the Carm fluoroscopy which is commonly used for locating metal foreign bodies. However, its application for removal of broken instruments in the oral and maxillofacial area is not common. In our experiences with the removal of two broken instruments in mandibular area, the newly developed dental mini C-arm was used to find broken instrument in soft tissue, because it gives real-time in situ information for the intraoperative location. We report two cases with broken instruments, a broken dental needle in the pterygomandibular space and a broken straight bur in the mandibular angle area. They were identified and could be removed safely using a dental mini C-arm.

SIMPLE DOUBLE EYELID OPERATION (ORIENTAL BLEPHAROPLASTY) USING Y NEEDLE (Y needle을 이용한 간단한 이중검 수술)

  • Yang, Byoung-Eun;Kim, Seong-Gon;Kim, Yong-Kwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.2
    • /
    • pp.157-161
    • /
    • 2004
  • The eyes, the saying goes, are the windows of the soul. It's the first thing you notice about a person. Therefore, many people want to possess beautiful eyelids. Surgical formation of a palpebral fold and sulcus divides the lid into two well-defined segments (palpebral and pretarsal), producing the double eyelid desired by many Oriental women as well as an increasing number of man recently. Upper lid blepharoplasty is the Oriental eye is one of the variations of standard upper lid blepharoplasty. In Oriental double eyelid surgery, there have been two approaches to form a superior palpebral fold: the buried suture(nonincision) method and the full external incision method. Conventionally, the nonincision technique has been shown to produce little postoperative edema. However, the probability of the fold disappearing is high, and this technique cannot be performed in patients with fatty eyelids. Conversely, the incision technique has contrary characteristics. Recently, partial incision(or semi-open) technique which is combination of mentioned methods is used, this technique is removal of pretarsal tissue, muscle, and/or orbital fat around 2 or 3 incision site to facilitate tarsus-dermal adhesion. Our method is on the basis of this technique, furthermore, compared with conventional semi-open method, Y(Yang's) needle assisted double eyelid operation is more easy, convenient, saving-time method and provide satisfactory results.

Surgical Removal of the Lung Lobe Metal Foreign Body in a Dog

  • Hwang, Yawon;Kang, Jihoun;Chang, Dongwoo;Kim, Gonhyung
    • Journal of Veterinary Clinics
    • /
    • v.34 no.2
    • /
    • pp.108-111
    • /
    • 2017
  • A 4-year-old, weighing 7.6 kg, castrated male, Pug presented with ingestion of gastric cavity foreign body. Physical examination revealed panting, retching and hyper-salivation. Blood chemistry and complete blood cell count were normal, but hypophosphatemia was observed. An abdominal radiograph revealed the foreign body (FB), round shape and 2 cm length, at the pyloric region of stomach. A thoracic radiograph revealed an incidental metal FB, 3.5 cm length, at the cranial portion of the diaphragm. An upper gastrointestinal endoscopy was performed to remove the FB in the stomach and then a peach-pit was removed. However the metal FB was not found in the esophagus therefore a lateral thoracotomy was performed. A right lateral thoracotomy through the $7^{th}$ intercostal space was accomplished to expose the right caudal lung lobe. After open the thoracic cavity, foreign body was not observed by gross evaluation and caudal lung lobe was attached to the diaphragm. The FB was identified inside the lung lobe and surrounded by granulation tissue. The metal FB (sewing needle) was removed with blunt dissection and incised lung lobe was sutured using absorbable suture material PDS 4-0 with interrupted suture. A thoracotomy tube was inserted into the thoracic cavity during surgery. Patient's respiration became stable after surgery. A chest tube was removed 3 days after surgery. No complications were noted and the dog was discharged 4 days after surgery. In small animal, foreign body ingestion is a common reason for emergency. After ingestion of the FB, perforation through the esophagus and migration to inside the lung lobe is not common in small animals. In this case, thoracic metal FB was identified incidentally and removal of a thoracic FB with thoracotomy was performed successfully.

Thinning Effects on Litterfall Inputs and Litter Decomposition in Pinus densiflora S. et Z. and Quercus variabilis Blume Stands

  • Baek, Gyeongwon;Baek, Gyeongrin;Kim, Hojin;Lee, Jihyun;Kim, Hyungsub;Kim, Choonsig
    • Journal of Forest and Environmental Science
    • /
    • v.38 no.1
    • /
    • pp.48-54
    • /
    • 2022
  • This study was conducted to examine litter inputs and litter decomposition rates following thinning, which is among the most important forest management activities that enhance the beneficial functions in Korean forests. Litter inputs and litter decomposition rates following a 2-year elapse from thinning in Pinus densiflora and following a 7-year elapse from thinning in Quercus variabilis stands were measured for 2 years from 16 sites in three regions (Sancheong-gun, Uiryeong-gun, and Jinju-si) in Gyeongsangnam-do, Korea. Annual needle litter inputs in P. densiflora stands were significantly decreased following thinning, whereas annual broadleaved leaf litter inputs in Q. variabilis stands were not significantly different between thinned and unthinned treatments. The annual mean total litter inputs in both tree species were significantly lower in the thinned (P. densiflora: 3,653 kg ha-1 year-1; Q. variabilis: 4,963 kg ha-1 year-1) compared to the unthinned stands (P. densiflora: 5,138 kg ha-1 year-1; Q. variabilis: 5,997 kg ha-1 year-1) during the study period. The mass loss rates from decomposing needle litter in P. densiflora stands were significantly lower (p<0.05) in the thinned stands than in the unthinned stands for two sampling dates of the eight included in the study, whereas the decomposition rates from decomposing leaf litter in Q. variabilis stands were not affected by thinning. The results indicate that thinning effects on total litter inputs remained clear following a 2-year elapse from thinning in P. densiflora stands and following a 7-year elapse from thinning in Q. variabilis stands.

Thoracoscopic Removal of an Intrapulmonary Sewing Needle - A case report - (폐실질 내 바늘의 흉강경을 통한 수술적 제거 - 1예 보고 -)

  • Yu, Jeong-Hwan;Kang, Shin-Kwang;Na, Myung-Hoon;Lim, Seung-Pyung;Lee, Young;Yu, Jae-Hyeon
    • Journal of Chest Surgery
    • /
    • v.40 no.11
    • /
    • pp.798-801
    • /
    • 2007
  • A 24 year old man visited our hospital, because an intrapulmonary foreign body had been found incidentally. Simple chest X-ray showed a 5 cm sized foreign body of metallic density, and chest CT confirmed the foreign body, which was like a sewing needle, in the left upper lobe. We performed a simple extraction of the foreign body using VATS (Video Assisted Thoracic Surgery). After the operation, the patient was discharged without any complications.

Pseudoaneurysm of the superficial temporal artery after blunt trauma: case report and literature review

  • Kang, Inho;Mo, Young Woong;Jung, Gyu Yong;Shin, Hea Kyeong
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.3
    • /
    • pp.130-133
    • /
    • 2022
  • An 88-year-old man presented with a left temporal pulsatile mass that developed after blunt trauma. Based on suspicion of hematoma, needle aspiration was performed with the removal of approximately 15 mL of blood. No evident improvement was noted, and active arterial bleeding was observed at the needle puncture site. Doppler ultrasonography revealed a "yin-yang" sign, and the mass was diagnosed as a pseudoaneurysm of the left superficial temporal artery. Under general anesthesia, the superficial temporal artery was ligated and the pseudoaneurysm was removed. Superficial temporal artery pseudoaneurysm is a rare facial tumor that generally occurs after blunt trauma. Due to its rarity, pseudoaneurysms are often misdiagnosed as hematoma. The treatment of choice is excision, although endovascular intervention is a potential treatment option. However, when a pseudoaneurysm is small, conservative treatment can be used.

Accidental Total Spinal Anesthesia Following Thoracic Epidural Block -A case report- (흉부 경막외 차단 시 발생된 우발적 전척추마취 -증례 보고-)

  • Yang, Se-Ho;Jang, Young-Ho;Cheun, Jae-Kyu
    • The Korean Journal of Pain
    • /
    • v.14 no.2
    • /
    • pp.249-252
    • /
    • 2001
  • Total spinal anesthesia is a serious life threatening complication of spinal and epidural anesthesia. We report an accidental total spinal anesthesia developed during a thoracic epidural block in a practitioner's pain clinic. A 69-year-old female with post-herpetic neuralgia was treated by a thoracic epidural block. A thoracic tapping for the epidural block was performed in the right lateral position at a level between $T_{5-6}$, using a 23 gauge Tuohy needle. After the epidural space was identified, a mixed solution of 10 ml of 0.3% lidocaine and 20 mg of triamcinolone was injected into the epidural space. After removal of the syringe, fluid was dripping through the needle. The patient subsequently complained of dyspnea and dizziness, and she became unconscious. She was intubated immediately and cardiopulmonary resuscitation was performed because there was no pulse palpable. The patient recovered an hour after transfer to a general hospital and was discharged without any further complication 19 days later.

  • PDF

Pine Needle Extract Applicable to Topical Treatment for the Prevention of Human Papillomavirus Infection

  • Lee, Hee-Jung;Park, Mina;Choi, HeeJae;Nowakowska, Aleksandra;Moon, Chiung;Kwak, Jong Hwan;Kim, Young Bong
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.1
    • /
    • pp.137-143
    • /
    • 2021
  • Most cervical cancers are associated with high-risk human papillomavirus (HPV) infection. Currently, cervical cancer treatment entails surgical removal of the lesion, but treatment of infection and preventing tissue damage are issues that still remain to be addressed. Herbal medicine and biological studies have focused on developing antiviral drugs from natural sources. In this study, we analyzed the potential antiviral effects of Pinus densiflora Sieb. et Zucc. leaf extracts against HPV. The pine needle extracts from each organic solvent were analyzed for antiviral activity. The methylene chloride fraction (PN-MC) showed the highest activity against HPV pseudovirus (PV). The PN-MC extract was more effective before, rather than after treatment, and therefore represents a prophylactic intervention. Mice were pre-treated with PN-MC via genital application or oral administration, followed by a genital or subcutaneous challenge with HPV PV, respectively. The HPV challenge results showed that mice treated via genital application exhibited complete protection against HPV. In conclusion, PN-MC represents a potential topical virucide for HPV infection.

A Retained Polyethylene Catheter Fragment in Superior Vena Cava - A case report- (상대정맥내 폴리에틸렌관 잔존물 치험 1례)

  • 김주현
    • Journal of Chest Surgery
    • /
    • v.13 no.2
    • /
    • pp.134-137
    • /
    • 1980
  • This represents a case report of the retained polyethylene catheter fragment in superior vena cava. A 39 year old male was admitted to this Korea University Hospital a short time after compression wound on abdomen with heavy cement material in emergency room, a polyethylene catheter was introduced into the right subclavian vein through a needle. But when the polyethylene catheter was attempted to withdraw the catheter was severed by the beveled tip of the needle. Later that day, chest X-ray disclosed the presence of the fragment extending from right subclavian vein to the superior vena cava. {Fig. 1 and Fig. 2]. Local exploration by way of an infraclavicular incision was unsuccessful in locating the catheter fragment. Another attempt was then made remove the catheter by means a biotome, which is originally a device for the biopsy of the myocardium, introduced through the right great saphenous vein. This procedure, though well tolerated by the patient, was in vain. After 11 days later, during that time he was taken a laparotomy with drain, another operation for removal of retained catheter fragment was performed through median sternotomy. After exposure of the right subclavian vein, innominate vein, and superior vena cava, an incision 1 cm in |length was made directly over the palpated catheter. The catheter immediately was picked upward and removed. The length of the catheter was approximately 8 cm. [Fig 3 ] There was no evidence of thromboembolism from the catheter or other complications. The patient made an uneventful recovery, and was discharged asymptomatic on the 9th postoperative day.

  • PDF