• Title/Summary/Keyword: Removal efficiency rate

Search Result 1,301, Processing Time 0.031 seconds

A study on the desulfurization wastewater treatment using Ferrate(VI) (Ferrate(VI)를 이용한 발전소 탈황폐수 처리에 관한 연구)

  • Jo, Eun-young;Park, Chan-gyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.4
    • /
    • pp.297-301
    • /
    • 2017
  • Wastewater treatment using ferrate (VI) solution is becoming a promising technology for several years, because it is high efficient and harmless technology. In this study, the ferrate (VI) solution was tested to treatment of desulfurization wastewater. The effluent from desulfurization wastewater treatment process of power plant was used as raw water, and the COD and T-N removal efficiency of ferrate(VI) solution were investigated. In the test, as the injection rate increased from 0.1 to 1.0%, the removal efficiency of COD also slightly increased, about 80% of COD were removed in 1.0% of injection rate. In the case of T-N, about 50% of T-N was removed in the condition of 1.0% of injection rate. The removal efficiency of COD and T-N also affected by reaction time, maximum removal efficiency was shown in 30 min of treatment. From these results, the wastewater treatment with ferrate(VI) solution can be great solutions for treatment of non-biodegradable pollutants in wastewater, especially for the 3rd treatment of wastewater.

Fabrication of Flow Cell Using Carbon Fiber and Electrochemical Decomposition Characteristics for Organic Dyes (탄소섬유전극을 이용한 흐름형 전기분해조 제작 및 유기염료의 전기화학적 분해 연구)

  • Park, Deog-Su
    • Journal of Environmental Science International
    • /
    • v.21 no.11
    • /
    • pp.1371-1377
    • /
    • 2012
  • The simulated dyes solution containing Basic Red 46(BR 46), Yellow 21(Y 21), and Maxilon Blue 30(MB 30) were electrochemically oxidized using carbon fiber as an anode. The electrolyses were performed in a electrolytic flow cell constructed by Vycor glass tube. The carbon fiber was positioned in the inside of Vycor glass tube and platinum wire coiled around outside of tube as a cathode. Several operating variables, such as current, time, pH and flow rate of solution were studied. Increasing current density would lead to a corresponding increase in the dye removal efficiency 99.2 % at a 200 mA. The electrolyses time could also improve and removal efficiency was about 99 % after 1.5 hours of electrolyses. The removal efficiency was increased with the increase of flow rate of solution and optimum flow rate was 5 mL/min. THe pHs of solution affect the removal efficiency. The removal efficiency was decreased with the increase of pH of solution and optimum pH was 5.05 (0.1 M $KNO_3$).

Removal of Methane Using a Three Phase Fluidized Bed Bioreactor (3상 유동층생물반응기를 이용한 메탄처리에 관한 연구)

  • 김동욱;서혁상
    • KSBB Journal
    • /
    • v.13 no.2
    • /
    • pp.141-146
    • /
    • 1998
  • To remove the low concentration of methane biologically, a three phase fluidized bed bioreactor immobilized with Methylosinus trichosporium OB3b was used. Optimum pH, temperature and bed height for the operation were pH7.0, 30$^\circ C$ and 150cm, respectively. For the inlet methane concentration of 100-400ppm and flow rate of 2-4L/min, the removal efficiencies of the bioreactor using the activated carbon as a carrier were the range of 54-71%, whereas those using the biosand were the range of 45-56%. It was found that activated carbon was more efficient than the biosand for the removal of methane. When aeration tank was equipped with the bioreactor, the removal efficiency increased to 6-13% and maximum removal rate obtained in the experiment was 1184mg.CH$_4$/min.

  • PDF

The Characteristics of the Ozonation of the Phenol Wastewater in the Continuous PCR and BCR (연속식 PCR과 BCR에서 기$cdot$액 접촉 방법 및 주입 오존 유량에 따른 페놀 폐수의 오존 처리특성)

  • Kim, Yong-Dai;Ahn, Jae-Dong;Lee, Joon
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.1
    • /
    • pp.57-64
    • /
    • 1996
  • The main objectives of this research program were to study the ozonation characteristics of phenol wastewater in the continuous packed colamn reactor(PCR) and the bubble column reactor (BCR) using ozone and to provide the fundamentals of ozonizing the phenol wastewater. Among various influencing factors that affect on phenol decomposition through the oxidation by ozone, contacting method, and ozone flow rate were chosen as reaction parameters. The results were obtained from two different types of contacting methods where the countercurrent flow was more efficient than the cocurrent flow in both the phenol removal efficiency and the ozone utilization efficiency. Furthermore, PCR showed the phenol removal efficiency 1.6 to 3% higher than that of BCR in both contacting methods, as well as the ozone utilization efficiency, suggesting that the countercurrent flow is more efficient than the cocurrent flow. The phenol removal efficiency and the ozone utilization efficiency were reduced in both reactors as the influent ozone flow rate increased. Upon varing flow rate from 0.5l/min to 2.0 l/min by 0.5 l/min, the phenol removal efficiency was reduced approximately from 8.5% to 10.5% and the ozone utilization efficiency was reduced approximately from 6% to 8% in both reactors. The performance of PCR was superior to that of BCR in the aspects of phenol removal and ozone utilization efficiency.

  • PDF

Removal of Tetrachloroethylene using Advanced Oxidation Processes (고급산화법을 이용한 Tetrachloroethylene의 처리)

  • Shin, Hang-Sik;Lim, Jae-Lim
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.4
    • /
    • pp.64-72
    • /
    • 1996
  • The effect of $O_3$, $O_3/pH$, and $O_3/H_2O_2$, $O_3/UV$, and $H_2O_2/UV$ advanced oxidation process(AOP) were investigated for the treatment of tetrachloroethylen(PCE) at various condition. The removal efficiency of 10, 20, and 30ppm PCE by ozonation were almost same, only about 60%. And pseudo first-order rate constants, ko for overall oxidation was about 0.097($min^{-1}$). In the $O_3/pH$ AOP experiment for the 20ppm PCE, the removal rate of PCE increased with the increase of pH. However, mineralization rate of PCE at pH 7 was higher than at pH 10. In the $O_3/H_2O_2$ AOP, the removal rate of PCE was the highest at peroxide-to-ozone dosage ratio of about 0.9, which PCE was removed over 99.95%. Despite 42% of PCE was directly photolyzed by the UV irradiation, the removal efficiency of PCE by $O_3/UV$ AOP was only about 70%. In $H_2O_2/UV$ AOP, the removal efficiency of PCE increased to about 98% in proportion to the $H_2O_2$ injection concentration at constant UV intensity of 5W/l.

  • PDF

Flue Gas Sulfur Dioxide Removal Performance of a Bench-Scale Spray Absorption/Drying Reactor (실험실적 규모의 분무흡수건조반응기의 배출가스 중 아황산가스 처리성능 연구)

  • 동종인;구우회;임대현
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.449-457
    • /
    • 1996
  • The main purpose of this study was to investigate sulfur dioxide removal performance of flue gas desulfurization system utilizing a Spray Absorption/Drying Reactor. In this system, the size of droplets was considered the most significant factor and tested using a PDA system. Lime slurry flow rate, operating temperature, calcium/sulfur (Ca/S) ratio and applied air pressure were selected as major operation variables and tested/analyzed in terms of system performance. The results are as follows. 1. The $SO_2$ removal efficiencies were 49%, 74%, 85% for Ca$(OH)_2$ slurry flow rate of 10, 20, 30 ml/min, which implies that the increase of slurry flow rate improves removal efficiency. The optimum slurry flow rate in this study was, however, considered 20 ml/min because of constraints of system troubles and absorbent utilization. 2. As Ca/S ratio increased, $SO_2$ removal efficiency was observed to increase. 3. As air pressure, at the atomizing nozzole, increased from 3 to 5 $kg/cm^2, SO_2$ removal efficiency increased from 74% to 80%, because of droplet size reduction due to pressure increase during atomizing process and the increase of surface area, helping mass transfer between gas and liquid phase.

  • PDF

A Study on Toluene Removal of VOC and Characteristics of Material Using Biofilter (Bio필터를 이용한 VOC 가스 중 Toluene 제거율과 필터특성 연구)

  • 강신묵;하상안
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.2
    • /
    • pp.88-94
    • /
    • 1998
  • This study was investigated the application of biofiltration using cometabolic process to remediate gaseous toluene that are highly recalcitrant to adsorption, absorption and biodegradation. The investigation was conducted using specially built steel columns packed with granular activated carbon for removal of toluene and G.A.C was also coated with Pseudomonas putida microorganisms by addition of KH$_{2}$PO$_{4}$. The biofilter unit was operated in the condition of dry and 27.5% moisture content at gas loading rate of 12.5 l/min. Gaseous toluene taken from tedlar bag was analyzed by the use of G.C. equipped with F.I.D. detector. The removal efficiency of gaseous toluene was 85% at average inlet concentration of 970 ppm during dry operating condition. For gaseous toluene, 91% removal efficient was obtained at the filter material with moisture content and 97% removal efficiency was obtained with Pseudomonas putida microorganisms at gas loading rate of 12.5 l/min.

  • PDF

A Study on $SO_2$Removal in Flue Gas by Semidry Flue Gas Desulfurization Method (반건식 배연탈황법에 의한 연소 페가스 중 $SO_2$제거에 관한 연구)

  • Song, Ho-Cheol;Lee, Yun-Gi;Park, Jin-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.4
    • /
    • pp.273-280
    • /
    • 1998
  • The investigation on the removal of 502 gas fro.In flue gas which causes serious air pollution was made by using a semi dry flue gas desulfurization method. Experiments were carried out as a function of process variables which would affect SO2 removal efficiency. Process variables inclilded SO2 inlet concentration, inlet temperature of simulated flue gas, sorbent weight fraction, and volume flow rate of sorbent slurry. In this study, used sorbent was Ca(OH), and simulated flue gas was prepared by mixing pure SO2 gas with air. Experimental conditions were varied at 140~18$0^{\circ}C$ of inlet temperature of the simulated flue gas, 500~2000ppm of inlet SO2 concentration, 0.4~1.0% of sorbent concentration, and 10~25 mL/min of flow rate of sorbent slurry. Among process variables, inlet concentration of SO2 was found to be the most significant factor to affect SO2 removal efficiency. The concentration of Ca(OH2) had a lower effect on SO2 removal than SO2 inlet concentration removal amount was 0.108, 0.141, 0.153 g SO2/g Ca(OH)2 respectively- As 200 mmol of HNO3 was added into slurry to improve removal efficiency, initial pH was maintained and solubility of slurry increased, so that removal efficiency elevated. Adding over 200 mmol of HNO3 into slurry caused removal efficiency lower. Therefore it could be concluded the optimum was 200 mmol of HNO3 input.

  • PDF

The Effect of Pressure and Platen Speed on the Material Removal Rate of Sapphire Wafer in the CMP Process (CMP 공정에서 압력과 정반속도가 사파이어 웨이퍼 재료제거율에 미치는 영향)

  • Park, Sanghyun;An, Bumsang;Lee, Jongchan
    • Tribology and Lubricants
    • /
    • v.32 no.2
    • /
    • pp.67-71
    • /
    • 2016
  • This study investigates the characteristics of the sapphire wafer chemical mechanical polishing (CMP) process. The material removal rate is one of the most important factors since it has a significant impact on the production efficiency of a sapphire wafer. Some of the factors affecting the material removal rate include the pressure, platen speed and slurry. Among the factors affecting the CMP process, we analyzed the trends in the material removal rate and surface roughness, which are mechanical factors corresponding to both the pressure and platen speed, were analyzed. We also analyzed the increase in the material removal rate, which is proportional to the pressure and platen speed, using the Preston equation. In the experiment, after polishing a 4-inch sapphire wafer with increasing pressure and platen speed, we confirmed the material removal rate via thickness measurements. Further, surface roughness measurements of the sapphire wafer were performed using atomic force microscopy (AFM) equipment. Using the measurement results, we analyzed the trends in the surface roughness with the increase in material removal rate. In addition, the experimental results, confirmed that the material removal rate increases in proportion to the pressure and platen speed. However, the results showed no association between the material removal rate and surface roughness. The surface roughness after the CMP process showed a largely consistent trend. This study demonstrates the possibility to improve the production efficiency of sapphire wafer while maintaining stable quality via mechanical factors associated with the CMP process.

Chemical/Electro-Chemical Method for Swine Wastewater Treatment (화학적/전기화학적 방법을 이용한 돈사폐수 처리)

  • Yoon, S.J.;Jo, W.S.;Kim, C.H.;Park, J.I.;Shin, J.S.;Ra, C.S.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.4
    • /
    • pp.641-648
    • /
    • 2003
  • In a batch mode treatment process, which electrolyzes the wastewater after derivation of N-P crystal formation and recovery, the characteristics of pollutant removal induced with the changes of loading rate and hydraulic retention time were studied. $MgCl_2$ was used as Mg source for the formation of struvite and the molar ratio of $MgCl_2$ to $PO_4^{3-}$ in influent was 1.3. When analyzing the average treatment efficiencies and removal characteristics obtained from four separate operations (Run I, II, III, IV), removal efficiencies of PO43- was not function of its loading rate. Under a condition of sufficient aeration and Mg source provided, over 88% of $PO_4^{3-}$ was eliminated by the formation of MAP without any pH adjustment, in spite of loading rate variation. An optimum-loading rate of NH4-N to achieve high removal efficiency was approximately $100g/m^3/d$. Below that loading rate, the removal of NH4-N was proportional to the loading rate into the system, and hence stable and high removal efficiency, over 90%, was achieved. However, when the loading rate increased over that rate, removal efficiency began to drop and fluctuate. Removal efficiency of TOCs was dependant upon the hydraulic retention time ($r^2$=0.97), not upon the loading rate. Stable and high color removal (94%) was obtained with 2 days of HRT in electrolysis reactor.