• 제목/요약/키워드: Removal and recovery

검색결과 515건 처리시간 0.022초

Global technologies for the removal of water scaling & water recovery - Department of Energy (DOE) USA

  • Ramakrishna, Chilakala;Thriveni, Thenepalli;Whan, Ahn Ji
    • 에너지공학
    • /
    • 제27권1호
    • /
    • pp.21-32
    • /
    • 2018
  • In this paper, we reported the current technologies of water scaling removal and also water recovery from the flue gases, which are funded by Department of Energy (DOE), USA. Globally, water resources are limited due to the climate change. The potential impacts of climate change is food and water shortages. In the $21^{st}$ century, water shortages and pollution are expected to become more acute as populations grow and concentrate in cities. At present, the water stress increases over 62.0 ~ 75.8% of total water basin area and decreases over 19.7 ~ 29.0%. Many renewable energy sources demand secure water resources. Water is critical for successful climate change mitigation, as many efforts to reduce greenhouse gas emissions depend on reliable access to water resources. Water hardness is one of the major challenge to coal power plants. Department of energy (DOE) funded and encouraged for the development of advanced technologies for the removal of hardness of water (scaling) and also water recovery from the flue gases from coal power plants.

표면처리 공정에서 발생하는 혼합 폐수의 전기화학적 처리에 의한 중금속의 재활용 및 유기물의 제거에 관한 연구 (A Study on the Recycling of Metals and Removal of Organics By Electrochemical Treatment of Mixed Waste Water of Surface Finishing Industry)

  • 김영석;이중배
    • 한국표면공학회지
    • /
    • 제36권2호
    • /
    • pp.184-193
    • /
    • 2003
  • Cyclic sweep voltametry was performed to investigate the electrochemical behavior of heavy metal ions and the organic additives in surface finishing process. And electrolysis using parallel plate electrode electrolyzer was carried out to simulate the treatment of real waste water. Results showed that more than 99 percent of Cu was recovered and selective recovery of Cu in mixed waste water was possible, but the possibility of economical recovery of Ni and Cr were very low due to the evolution of hydrogen gas. Electrochemical oxidation of cyanide and organic additives on anode showed very excellent removal rate. The complete removal of several hundred ppm of cynide was possible within several tens minutes and organics within 2 or 3 hours. Even in case of concentrate waste water, the complete removal of COD by using NaCl and air stirring seemed to be possible.

Recovery of Trichloroethylene Removal Efficiency through Short-term Toluene Feeding in a Biofilter Enriched with Pseudomonas putida F1

  • Jung In-Gyung;Park Ok-Hyun;Woo Hae-Jin;Park Chang-Ho
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제10권1호
    • /
    • pp.34-39
    • /
    • 2005
  • Trichloroethylene (TCE) is an environmental contaminant provoking genetic mutation and damages to liver and central nerve system even at low concentrations. A practical scheme is reported using toluene as a primary substrate to revitalize the biofilter column for an extended period of TCE degradation. The rate of trichloroethylene (TCE) degradation by Pseudomonas putida F1 at $25^{\circ}C$ decreased exponentially with time, without toluene feeding to a biofilter column ($11\;cm\;I.D.{\times}95\;cm$ height). The rate of decrease was 2.5 times faster at a TCE concentration of $970\;{\mu}g/L$ compared to a TCE concentration of $110\;{\mu}g/L$. The TCE itself was not toxic to the cells, but the metabolic intermediates of the TCE degradation were apparently responsible for the decrease in the TCE degradation rate. A short-term (2 h) supply of toluene ($2,200\;{\mu}g/L$) at an empty bed residence time (EBRT) of 6.4 min recovered the relative column activity by $43\%$ when the TCE removal efficiency at the time of toluene feeding was $58\%$. The recovery of the TCE removal efficiency increased at higher incoming toluene concentrations and longer toluene supply durations according to the Monod type of kinetic expressions. A longer duration ($1.4{\sim}2.4$ times) of toluene supply increased the recovery of the TCE removal efficiency by $20\%$ for the same toluene load.

Ammonia Nitrogen Removal and Recovery from Swine Wastewater by Microwave Radiation

  • La, Joohee;Kim, Taeyoung;Jang, Jae Kyung;Chang, In Seop
    • Environmental Engineering Research
    • /
    • 제19권4호
    • /
    • pp.381-385
    • /
    • 2014
  • Microwave (MW) radiation was developed to remove and recover ammonia nitrogen in the real swine wastewater. The effect of operating parameters of MW radiation such as initial pH, power, radiation time, aeration, and stirring for removal ammonia nitrogen in swine wastewater was determined. The pH, radiation time, and power were significantly influenced on the removal of ammonia nitrogen, and aeration and stirring showed relatively minor effect on the removal of ammonia nitrogen. Optimum condition was achieved to retrieve the nitrogen efficiently at pH 11, 700 W for 5 min in MW radiation process. Through this process, 83.1% of ammonia nitrogen concentration was reduced in swine wastewater and also 82.6% of ammonia nitrogen was recovered as ammonium sulfate at the optimized condition. The high ammonia removal and recovery efficiency of the MW radiation method indicated that MW radiation was an effective technique to remove and recover ammonia nitrogen in the swine wastewater.

의류관리기 내 직물거동이 구김 제거에 미치는 영향 (The Effect of Fabric Movement on Wrinkle Recovery in a Clothing Care System)

  • 유동주;윤주희;이상욱;윤창상
    • 한국의류학회지
    • /
    • 제45권2호
    • /
    • pp.335-345
    • /
    • 2021
  • The purpose of this study was to examine the effect of fabric movement on wrinkle recovery in a clothing care system and to propose an algorithm to improve wrinkle removal performance by adjusting fabric movements. With an increase in the reciprocating speed of the movement system, the number and amplitude of curves on the fabric also increased. This allowed the fabric to be applied to a larger tension, resulting in better wrinkle removal performance at higher speeds. However, even at high reciprocating speeds, wrinkles could not be removed effectively because of nodes at a few specific locations. Based on the results of fabric movement and wrinkle recovery, a complex movement algorithm was proposed with a mixture of various reciprocation speeds. It showed a 41%p (24%→65%) improvement of wrinkle recovery when compared with the conventional algorithm that showed simple fabric movement at 180 rpm. This was because the positions of nodes and antinodes changed continuously and the force by the reciprocating motion could be applied evenly to the fabric.

Fabrication of Ti/Ir-Ru electrode by spin coating method for electrochemical removal of copper

  • Kim, Joohyun;Bae, Sungjun
    • Environmental Engineering Research
    • /
    • 제24권4호
    • /
    • pp.646-653
    • /
    • 2019
  • Recovery of valuable metals in the industrial wastewater and sludge has attracted an attention owing to limited metallic resources in the earth. In this study, we firstly fabricated Ti/Ir-Ru electrodes by spin coating technique for effective recovery of Cu in electrowinning process. Two different Ti/Ir-Ru electrodes were fabricated using 100 and 500 mM of precursors (i.e., Ir-Ru). SEM-EDX and AFM revealed that Ir and Ru were homogenously distributed on the surface of Ti plate by the spin coating, in particular the electrode prepared by 500 mM showed distinct boundary line between Ir-Ru layer and Ti substrate. XRD, XPS, and cyclic voltammetry also revealed that characteristics of IrO2, RuO2, and TiO2 and its electrocatalytic property increased as the concentration of coating precursor increased. Finally, we carried out Cu recovery experiments using two Ti/Ir-Ru as anodes in electrowinning process, showing that both anodes showed a complete removal of Cu (1 and 10 g/L) within 6 h reaction, but much higher kinetic rate constant was obtained by the anode prepared by 500 mM. The findings in this study can provide a fundamental knowledge for surface characteristics of Ti/Ir-Ru electrode prepared by spin coating method and its potential feasibility for effective electrowinning process.

사진폐액으로부터 용매추출에 의한 은의 제거 및 회수에 대한 기초연구 (Fundamental Studies for the Removal and Recovery of Silver from Waste Photo-Developing Solution by Solvent Extraction)

  • 이선화;김동수;이화영
    • 한국물환경학회지
    • /
    • 제22권1호
    • /
    • pp.122-127
    • /
    • 2006
  • Fundamental studies were carried out for an effective removal and recovery of silver from waste photo-developing solution by solvent extraction. The organic solvents examined for silver-extraction were ALIQUAT 336, D2EHPA, KELEX 100, and TBP. ALIQUAT 336, which is an anionic exchanger, was found to be efficient for the extraction of silver and the reason for this was considered to be due to the chloride ion contained in its structure. The extent of silver extraction was examined to increase with the concentration of ALIQUAT 336 until it reached 0.6 M and no more extraction was observed above this concentration. The extraction of silver by ALIQUAT 336 was found to reach its pseudo-equilibrium within a few minutes after the reaction started and additional slight increase in silver extraction was observed until 30 minutes of reaction time. The observed differences in silver extraction for artificial and actual waste solutions were considered to be based upon the different ionic form of silver-containing species in these solutions.

벨트식 유회수기를 사용한 디젤유 회수에 관한 실험적 연구 (An experimental study on the recovery of diesel oil using a belt type skimmer)

  • 송동업;윤경환
    • 한국해양공학회지
    • /
    • 제11권3호
    • /
    • pp.132-143
    • /
    • 1997
  • Removal of spilled oil over the sea and the river has become one of the urgent problem in these days. Removing oil using mechanical devices are recommended because chemical dispersion can cause the secondary contamination in the environment. In the present study a series of experiments were carried out to study the effect of working conditions of a belt type skimmer on the rate of recovery for the spilled oil. The oil chosen for the present experiment was diesel oil. Three different situations, namely, upward, downward, up-and-downward pickup have been investigated for various contact angles, belt speeds and oil thicknesses. The results show that the rate of oil recovery for the case of downward pickup with a contact angle of 45.deg. shows the highest among all the conditions. For the removal of spilled diesel oil the optimal belt speed can be found as the critical value to reach the saturated pickup rate for a given oil thickness. The recovery rate of bunker C oil shows 4-6 times higher than that for diesel oil. And the optimal belt speed for bunker C oil can be found less than that for diesel oil for the same slick thickness.

  • PDF

양돈폐수처리시 실규모 이단 혐기성공정의 성능 및 메탄회수 (Methane Recovery and Performances of Full-scale Two-stage Anaerobic Process Treating Piggery Wastewater)

  • 정진영;정윤철;강신현;정형숙
    • 한국물환경학회지
    • /
    • 제21권3호
    • /
    • pp.256-262
    • /
    • 2005
  • The purpose of this study is to investigate the performances of organic removal and methane recovery by using a full scale two-phase anaerobic system. The full scale two-phase anaerobic process was consists of an acidogenic anaerobic baffled reactor (ABR) and a methanognic upflow anaerobic sludge blanket (UASB) reactor. The volumes of acidogenic and methanogenic reactors were designed to $28.3m^3$ and $75.3m^3$. The two-phase anaerobic system represented 60-82% of COD removal efficiency when the influent COD concentration was in the range of 7,150 to 16,270 mg/L after screening (average concentration is 10,280 mg/L). After steady-state, the effluent COD concentration in the methanogenic reactor showed $2,740{\pm}330 mg/L$ by representing average COD removal efficiency was $71.4{\pm}8.1%$ when the operating temperature was in the range of $19-32^{\circ}C$. The effluent SCOD concentration was in the range of 2,000-3,000 mg/L at the steady state while the volatile fatty acid concentration was not detected in the effluent. Meanwhile, the COD removal efficiency in the acidogenic reactor showed less than 5%. The acidogenic reactor played key roles to reduce a shock-loading when periodic shock loading was applied and to acidify influent organics. Due to the high concentration of alkalinity and high pH in the effluent of the methanogenic reactor, over 80% of methane in the biogas was produced consistently. More than 70% of methane was recovered from theoretical methane production of TCOD removed in this research. The produced gas can be directly used as a heat source to increase the reactor temperature.

한국 재래산양에서의 과배란유기와 외래유전자 주입에 적합한 수정란의 회수에 관한 연구 (Studies on the Superovulation and Collection of microinjectable Embryos in Korean Native Goats (Capra hircus aegagrus))

  • 윤우식;이철상;;방남수;구덕본;한용만;신상태;유욱준;박창식
    • 한국가축번식학회지
    • /
    • 제21권4호
    • /
    • pp.373-379
    • /
    • 1997
  • This study was carried out to determine the hormone treatment scheme for an efficient superovulation and optimal recovery time for obtaining pronuclear embryos suitable for DNA injection in Korean native goats. For a superovulation, FSH(5.6mg) was given over four days in twice daily injections with (FSH/hCG group) or without(FSH group) hCG(100 IU) co-injection at the time of 7th FSH injection. Estrus cycle was synchronized by norgestomet ear-implantation for 11 days and its removal at the time of 6th FSH injection. Among the treated goats, the percentage of ovulated goats, which were examined at 70 to 76 h following implant removal, was greater in FSH/hCG group than in FSH group (100% vs 36.4%) but there was no significant difference in the mean numbers of ovulation points and fertilization rates between the two groups. To optimize hCG treatment scheme and recovery time, we injected hCG at the time of 7th (FSH/hCGa) or 8th(FSH/hCGb) FSH injection and then examined the developmental stage of the embryos recovered at different times after implant removal. In FSH/hCGa group, significant portions(31 to 44%) were beyond 1-cell stage, which was non-injectable, irrespective of their recovery time. However, in FSH/hCGb group recovered at 70 to 76 h after implant removal, great portions(69%) were fertilized and most of them(96.6%) were injectable 1-cell stage. Considering together the fertilization rate and developmental stage of recovered embryos, it is recommendable to administrate hCG at the time of final 8th FSH injection and collect the embryos at 70 to 76 h after implant removal to obtain injectable embryos as many as possible in Korean native goats.

  • PDF