• 제목/요약/키워드: Removal Strength of the Forms

검색결과 20건 처리시간 0.023초

고강도 콘크리트의 초기강도 발현에 따른 거푸집 탈형시기의 결정 (Determination of Removal Time of the Forms with the Strength Development of High Strength Concrete at Early Age)

  • 김은호;김영진;한민철;신병철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.99-102
    • /
    • 2003
  • This study discusses the determination of removal time of forms with early strength development in high strength concrete. According to the results, as W/B increases by 10%, the setting time is shortened by about 2 hours. The time when compressive strength of 8 MPa is gained is about 20 hours. Bond strength between form and concrete is highest around final setting time, but decreases drastically after that. Amount of concrete sticking on the form is large before setting, but after that, it is little. The rebound value of P type schmidt hammer is measured faster by 2-3 hours than compressive strength. It is also confirmed that the removal of forms is possible when the rebound value of P type schmidt hammer is more than 34

  • PDF

촉진형 AE감수제를 사용한 콘크리트의 최적공기산정을 위한 조기강도 발현 특성 연구 (A Study on Early-strength Development of Concrete Using Accelerating AE Water Reducing Agents for the Estimation of Optimum Duration)

  • 이주헌;사순헌;지석원;전현규;서치호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 추계 학술논문 발표대회 논문집
    • /
    • pp.91-94
    • /
    • 2006
  • The way to shorten a construction period is considered to an very important technology development element as reducing the formwork removal periods with promoting strength revelation own concrete. This study executed experiment to review usability of early strength revelation chemical admixture which is judged in ways effective with premature removal of form about concrete. Use of early strength revelation AE water reducin admixture is apperaing so that strength revelation by early hydration promotions is excellent. The results of being applied proposed work process are that compressive strength are appeared more than 5MPa within 16 hours so that removal of vertical form was possible. the concrete compressive strength satisfied with a more than 2/3 of specified concrete strength for removal of horizontal form are appeared in 42 hours of 27 MPa proportioning strength, in 36 hours of 30, 35 MPa proportioning strength so that the 6 days cycle time of concrete structural frame work is cut by 2 days as shortening delayed period in works of removing slab forms. So construction cost reductions and a construction period shortening are judged so that it is possible.

  • PDF

트리에탄올아민을 사용한 콘크리트의 현장 적용 실험 (An Experimental Application of Concrete Using TEA in Construction Field)

  • 황인성;임춘근;김성수;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문 발표회
    • /
    • pp.23-26
    • /
    • 2003
  • This study is intended to investigate the properties of early strength development by application of TEA to the field. According to the results, when TEA is added, fluidity is almost same to base concrete, and increases upto aimed slump after field flowing. Setting time does not differ in the case of base and TEA, but retarded after flowing. The time when compressive strength gains 5 MPa, which side form can be removed, is 23 hours, and so the removal time is shortened by I hours in comparison with plain concrete. But compressive strength is almost same to that of plain concrete at 28 days. The rebound value of P type schmidt hammer show similar tendency to compressive strength, and the rebound value of structure is higher than that of standard curing specimen due to heat capacity effect and drying by the air outside. Therefore, it is thought that if the rebound value of P type schmidt hammer is controled. by about 26 in consideration of open air environment, it is very effective to determine the removal time of side forms.

  • PDF

트리에탄올아민을 사용한 콘크리트의 현장 적용 실험 (An Experimental Application of Concrete Using TEA in Construction Field)

  • 황인성;임춘근;김성수;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.23.1-26
    • /
    • 2003
  • This study is intended to investigate the properties of early strength development by application of TEA to the field. According to the results, when TEA is added, fluidity is almost same to base concrete, and increases upto aimed slump after field flowing. Setting time does not differ in the case of base and TEA, but is retarded after flowing. The time when compressive strength gains 5 MPa, which side form can be removed, is 23 hours, and so the removal time is shortened by 1hours in comparison with plain concrete. But compressive strength is almost same to that of plain concrete at 28 days. The rebound value of P type schmidt hammer show similar tendency to compressive strength, and the rebound value of structure is higher than that of standard curing specimen due to heat capacity effect and drying by the air outside. Therefore, it is thought that if the rebound value of P type schmidt hammer is controled. by about 26 in consideration of open air environment, it is very effective to determine the removal time of side forms.

  • PDF

준설토 산세척 시 염산 농도가 중금속의 정화효율 및 존재형태에 미치는 영향 (Effect of Hydrochloric Acid Concentration on Removal Efficiency and Chemical Forms of Heavy Metals During Dredged Sediment Acid Washing)

  • 김기범;최용주
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제25권1호
    • /
    • pp.74-83
    • /
    • 2020
  • In this study, the effect of hydrochloric acid (HCl) concentrations on removal efficiency and chemical forms of heavy metals in dredged sediment during acid washing was investigated. The removal efficiencies of Zn, Cu, Pb, Ni and Cd by acid washing were 18.4-92.4%, 7.2-83.7%, 9.4-75%, 8.1-53.4% and 34.4-70.8%, respectively. Overall, the removal efficiencies of heavy metals were remarkably enhanced with the increase of the acid strength. However, the removal efficiencies for 0.5 and 1.0 M HCl were comparable, and both cases met the Korean soil contamination standard. Based on the sequential extraction results, concentration of the exchangeable fraction (F1), the most labile fraction, increased whereas concentrations of the other fractions decreased with increasing acid strength. Particularly, the carbonate (F2) and Fe/Mn oxides (F3) fractions drastically decreased by using 0.5 M or 1.0 M HCl. The current study results verified that acid washing could effectively reduce heavy metal concentrations and its potential mobility in dredged sediments. However, the study also found that acid washing may cause significant increase in bioavailable fraction of heavy metals, suggesting the need to evaluate the changes in chemical forms of heavy metals by acid washing when determining the acid strength to be applied.

고강도콘크리트 시공시 측면 거푸집 탈형시기의 결정 (Determination of Removal Time of the Side Form in High Strength Concrete)

  • 한천구;한민철
    • 콘크리트학회논문집
    • /
    • 제16권3호
    • /
    • pp.327-334
    • /
    • 2004
  • 본 연구에서는 초기재령에서 고강도콘크리트의 압축강도 발현 특성 검토 및 해석 그리고 콘크리트와 거푸집간의 부착강도 특성을 분석하며, P형 슈미트해머를 이용한 반발도와 압축강도간의 상관관계를 검토하므로서 실무의 고강도콘크리트 측면 거푸집 탈형과 연관한 관련규정의 적합성을 재검토하고, 아울러 거푸집제거와 연관한 효율적인 품질관리 방법에 대하여 제안하고자 한다. 연구결과에 따르면, W/B가 증가할수록 응결시간은 감소하는 것으로 나타났으며, 본 연구의 범위에서 로지스틱 모델에 의한 강도증진 해석 결과 압축강도 8MPa를 발휘하는 시간과 적산온도는 17${\~}$20시간, $21{\~}25^{\circ}D{\cdot}D$ 정도로 나타났다. 거푸집과 콘크리트의 부착강도는 종결시점에서 가장 크게 나타났으며 그 이후에는 감소함을 보였고, 거푸집에 부착되어 박리되는 콘크리트의 양은 응결이전에 크게 나타났으며, 그 이후에는 점차적으로 감소하는 경향을 보였다. P형 슈미트해머에 의한 반발도 실험결과 압축강도 발현시점보다 약 2${\~}$3시간 정도 빠르게 측정할 수 있으며, 반발도가 32 이상이면 측면 거푸집을 탈형 할 수 있는 시기로 품질관리가 가능할 것으로 판단되었다.

P형 슈미트 햄머의 반발도를 이용한 거푸집 탈형시기의 결정에 관한 타당성 검토 (Investigation on the Validities of Removal Time of the Forms Considering Rebound Number of P Type Shumidt Hammer)

  • 전충근;김상우;신병호;황인성;신병철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.909-912
    • /
    • 2001
  • This paper presents the validities of the removal time of side forms considering the relationship between rebound number of P type schmidt hammer and compressive strength. According to test results, compressive strength of 40% of W/C at 12 hours shows 16kgf/$cm^{2}$ and 50% of W/C at 15 hours, 13kgf/$cm^{2}$. Rebound number at 9 hours after casting shows 13 and 9 (W/C 40% and W/C 50%). According to the regression analysis, rebound number of P type schmidt hammer to gain 50kgf/$cm^{2}$ of is estimated 20.1. It is thought that desirable rebound number of P type schmidt hammer to gain 50kgf/$cm^{2}$ is determined 25 considering safety factor.

  • PDF

등가재령을 이용한 콘크리트의 강도 예측에 의한 건설생산현장에서의 강도관리에 관한 실험저 연구 (An Experimental Study in Strength Control by Prediction Strength of Concrete using Equivalent Age in Construction Field)

  • 주지현;최성우;박선규;김배수;남재현;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.287-290
    • /
    • 2000
  • Nowadays, strength control is performed by test of compressive strength of concrete which is taken in construction filed. But because it is possible to confirm only compressive strength of concrete by that way, it is difficult to performing strength control pr process plan, So, if we can predict compressive strength of concrete, we can decide when shores and forms can be removed safety, plan process efficiently. This study intends to propose basic data for strength control as determination the time of forwoak removal through investigating propriety of strength prediction using Freiesleben function.

  • PDF

액상형 조강제를 사용한 콘크리트의 초기강도 특성에 관한 연구 (A Study on the Early-Age Strength Property of Concrete Using Liquid Admixture)

  • 송태협;이세현;류득현;박조범
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.469-472
    • /
    • 2006
  • Amount used of admixture fare is increasing for concrete economic efficiency and ability security. Security of economic efficiency and ability can expect by use of this admixture fare but is displaying a lot of problems on early age strength hold by hydrate delay relatively. Specially, in the case of construction site, concrete strength can speak that interrelation is high with mold removal of forms time. Therefore, is economical and need examination of plan that can secure robber within 3 days using admixture fare such as fly ash and blast furnace slage differential speech to secure function. In this study, adding liquid admixture within 1% of a binding agent quantity to examine these problem with physical characteristic after hardening ago specially, strength change at standard and air dry curing of observed change in priority. Air dried and water curing total strength enhancement effects appeared by thing which is in case of add test result liquid admixture by below 1% and strength deputy by passage of age could know is not big.

  • PDF

조기강도발현형 AE감수제를 사용한 콘크리트의 현장 Mock-up 실험 (Mock-up Test of Concrete Using AE Water Reducing Agent of Early-Strength Type in Construction Field)

  • 황인성;김기훈;김규동;이승훈;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2004년도 학술.기술논문발표회
    • /
    • pp.1-4
    • /
    • 2004
  • In this paper. applicability of high early strength type AE water reducing agent(HESAEWA) developed by the authors is discussed by applying Mock-up test. For fresh concrete properties, concrete using existing AE water reducing agent(EAEWRA) and HESAEW A meets the target slump and air content at jobsite. Setting time of concrete using HESAEWA is shorter than that using EAEWRA. Remarkable variance of bleeding and settlement is not observed with type of AE water reducing agent. For hardened concrete properties, use of HESAEW A results in higher strength development compared with that of EAEWRA at standard curing and in field curing condition. Reaching time to accomplish 5MPa of compressive strength. which is possible to remove side form. is taken using HESAEWA earlier than that of EAEWRA by 1day. Therefore, it is confirmed that use of HESAEWA can meet the requirements of general quality of concrete and achieve high early strength development as well as has a desirable field applicability.

  • PDF