• Title/Summary/Keyword: Removal Rate

Search Result 3,890, Processing Time 0.035 seconds

Field Experiment on Iron and Aluminum Removal from Acid Mine Drainage Using an Apatite Drain System (인회석 배수시스템을 이용한 산성수의 철 및 알루미늄 제거에 대한 현장경험)

  • Choi, Jung-Chan;West, Terry R.
    • Economic and Environmental Geology
    • /
    • v.29 no.3
    • /
    • pp.315-323
    • /
    • 1996
  • An apatite drain was constructed on September 30, 1994 at the Green Valley Abandoned Coal Mine site near Terre Haute in west central Indiana. The primary objective of this experiment is to evaluate the long-term ability of the apatite drain to mitigate acid mine drainage (AMD) under field conditions. The drain 9 m long, 3.3 m wide, and 0.75 m deep, contain 95 rum to No. 30 mesh-size apatite ore (francolite) and receive AMD seepage from reclaimed gob piles, and designed according to the laboratory testing. The apatite drain was covered with limestone riprap and filter fabric to protect the drainage system from stormwater and siltation. The drain consists of about 50 metric tons of apatite ore obtained from a phosphate mine in Florida. A gabion structure was constructed downstream of the apatite drain to create a settling pond to collect precipitates. Apatite effectively removed iron up to 4,200 mg/l, aluminum up to 830 mg/l and sulfate up to 13,430 mg/l. The pH was nearly constant for the influent and effluent, ranging between 3.1 and 4.3. Flow rate measured at the gabion structure ranged from 3 to 4.5 l/m. Precipitates of iron and aluminum phosphate (yellow and white suspendid solids) continued to accumulate in the settling pond.

  • PDF

A study on reduction of springback defects in excavator tank cover part (굴삭기 Tank Cover 부품 뒤틀림 불량 저감에 대한 연구)

  • Jeon, Yong-Jun;Lee, Ha-Sung;Kim, Dong-Earn;Heo, Young-Moo
    • Design & Manufacturing
    • /
    • v.12 no.1
    • /
    • pp.52-57
    • /
    • 2018
  • With the recent strengthening of environmental regulations and the need for cost reduction, excavators, a type of construction equipment, are being miniaturized while components are being developed in consideration of stability. In the case of excavator press parts, mainly high-strength steel sheets are being used to enhance stability and reduce weight. However, in the case of high-strength materials, there is a need to research product forming methods to reduce Springback in defects arising in parts assembly due to Springback that result from the internal residual stress that occurs in press forming being released after product forming. Accordingly, regarding the tank cover, an excavator press-forming part, this study selected a method to reduce distortion through analysis of the Springback occurrence rate and Springback causes through a forming analysis. A forming analysis was conducted for the Springback of the tank cover. Deformations of 13.714 mm in the upper part and 6.244 mm in the inner part of the product occurred, while wrinkles occurred on the sides of the product due to uneven thickness. A forming analysis was conducted for the major shapes of the product to investigate the causes of Springback. Distortion deformation due to the bead in the center of the product was confirmed to be a large factor. A Springback reduction method of correcting uneven thickness in the product sides, a Springback reduction method of removing the bead, and a correction method of restriking after the final forming were used in a forming analysis to determine the degree of Springback reduction. For the forming method to correct uneven thickness in the sides, deformation was reduced by 12% in the upper side compared to the existing model, but deformation in the inner side increased by 1%. For the restriking forming method, deformation decreased by 25% in the upper side and 13% in the inner side. For the bead removal method, deformation decreased by 28% in the upper side and 13% in the inner side, the largest Springback correction results. This indicates that the bead has a large affect on Springback.

Treatment Level and Reactions of a Treatment Pond System Purifying Sinyang Stream Water (신양천 하천수정화 연못시스템의 처리수준 및 연못반응)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.8 no.6
    • /
    • pp.1-12
    • /
    • 2005
  • Treatment level and pond reactions of a pond system were examined from May to October 2002. The system was constructed in July 2000 for purifying water of Sinyang stream that flows into Koheung Estuarine Lake located in the southern part of the Korean Peninsula. The system was composed of a primary and a secondary pond in series and established on the rice field near the lake. Water pumped from the stream was funneled into the primary pond, whose effluent was discharged into the secondary pond by gravity flow. Effluent from the secondary pond was funneled into wetlands. About 130 $m^3$/day of water was pumped into the primary pond and detention time of the primary and secondary pond was about 2 days. DO from the surface to the 1.0 m depth of the primary and secondary pond was in the rage of 5.2 to 11.0 mg/L and 4.3 to 0.7 mg/L, respectively. DO at the bottom layer of the primary pond was 0 mg/L and that of the secondary pond ranged 3.0~4.7 mg/L. The primary pond functioned as a facultative pond and the secondary as an aerobic one. The temperature difference between the surface and bottom layers of the ponds in August was about $2.5^{\circ}C$ and that in May and October was about $1.0^{\circ}C$. Thermocline was observed in the primary pond during the high ambient temperature of August. The sludge depth of the primary pond in May, August, and October was 2.4, 1.9, and 2.2 cm, respectively. That of the secondary pond was 1.2, 1.0, and 1.1 cm, respectively. SS, $BOD_5$, T-N, and T-P concentrations in influent averaged 16.64, 6.71, 6.21, and 0.23 mg/L and those in effluent from the primary pond averaged 11.48, 4.97, 4.81, and 0.17 mg/L, respectively. The removal rates of the primary pond for SS, $BOD_5$, T-N and T-P were 31%, 26%, 22%, and 24%, respectively. Average concentrations of SS, $BOD_5$, T-N, and T-P in effluent from the secondary pond were 9.81, 4.07, 4.03, and 0.14 mg/L, respectively and the abatement rates of the secondary pond for SS, $BOD_5$, T-N and T-P were 20%, 12%, 13%, and 15%, respectively. SS, $BOD_5$, T-N and T-P concentrations in effluent from the primary pond were significantly low(p=0.001) when compared with those from the secondary one.

Effect of lonomycin and 6-Dimethylaminopurine on Oocyte Activation and Production of Rabbit Nuclear Transplant Embryos (Ionomycin과 6-Dimethylaminopurine이 토끼의 난자 활성화와 핵이식배 생산효율에 미치는 영향)

  • 하란조;강다원;최창용;윤희준;강태영;최상용;이효종;박충생
    • Journal of Embryo Transfer
    • /
    • v.13 no.1
    • /
    • pp.11-19
    • /
    • 1998
  • This study was to determine the effect of ionomycin and 6-dimethylaminopurine (6-DMAP) and/or elcetrical stimulation on the oocyte activation and production of rabbit nuclear transplant embryos. The oocytes were collected from the oviduct of superovulated rabbits at 14 h post hCG injection and cultured in TCM-199 containing 10% FBS until 19 h post hCG injection. To determine the optimum concentration and exposure time of 6-DMAP, some oocytes were activated with 5 $\mu$M ionomycin for 5 min and then in 2.0 mM 6-DMAP for 0.5 to 3.0 h, or in 1.0 to 3.0 mM 6-DMAP for 2.0 h. Other control oocytes were stimulated electrically(3X, 1.25 kV/cm, 60 $\mu$sec) in 0.3 M mannitol solution supplemented with 100 $\mu$M CaCl$_2$ and MgCl$_2$. The nuclear donor embryos of 8-cell stage were synchronized to G$_1$ phase of 16-cell stage, and the recipient cytoplasms were obtained from removal of the first polar body and a portion of membrane bound cytoplasm of the oocytes collected at 15 h post hCG injection. A separated blastomere was injected into the perivitelline space of the enucleated oocytes. The oocytes injected with nucleus were cultured until 19 h post hCG and then electrofused and activated by electrical stimulation with or without ionomycin and 6-DMAP. These nuclear transplant embryos were cultured in TCM-199 containing 10% FBS in 39˚C, 5% CO2 incubator for 120 h. For the oncytes activated parthenogenetically with electrical stimulation with or with-out ionomycin and the various concentration of exposure time of 6-DMAP, the highest cleavage(92.3%) and development to blastocyst stage(41.0%) were resulted from the oocytes activated by ionomycin and 2.0 mM 6-DMAP for 2.0 h, which were found to be significantly(P<0.05) higher than the cleavage(45.2%) and developement to blastocyst stage(14.3%) from the oocytes activated with electrical stimulation. The significantly(P<0.05) more oocytes(71.4%) developed to 4 cell stage at 24 h post activation by ionomycin and 6-DMAP than those by electrical stimulation(18.9%). For the nuclear transplant embryos, the cleavage rate was similarly high in oocyte activation by electrical stimulation with(79.4%) or without ionomycin and 6-DMAP(70.5%). However, the embryo development to blastocyst stage was significantly(P<0.05) higher in oocyte activation by electrical stimulation with ionomycin and 6-DMAP(44.4%) than by electrical stimulation only(25.0%). The significantly(P<0.05) more nuclear transplant embryos(45.6%) developed to 4 cell stage at 18 h post activation by electrical stimulation with ionomycin and 6-DMAP than those by electrical stimulation only(10.6%). These results indicated that the supplemental oocyte activation by ionomycin and 6-DMAP with electrical stimulation enhanced and accelerated the preimplanted in vitro development of the rabbit nuclear transplant embryos.

  • PDF

Electrochemical Properties of Needle Coke through a Simple Carbon Coating Process for Lithium Ion Battery (침상 코크스의 피치 코팅에 따른 리튬 이차전지 탄소계 음극소재의 전기화학적 특성)

  • Hwang, Jin Ung;Lee, Jong Dae;Im, Ji Sun
    • Applied Chemistry for Engineering
    • /
    • v.31 no.5
    • /
    • pp.514-519
    • /
    • 2020
  • Graphite materials for lithium ion battery anode materials are the most commercially available due to their structural stability and low price. Recently, research efforts have been conducted on carbon coatings by improving side reactions at the edge site of carbon materials. The carbon coating process has classified into a CVD by chemical reaction, wet coating process with solvent and dry coating by mechanical impact. In this paper, the rapid crush/coating process was used to solve the problem of which only few parts of the carbon precursor (pitch) can be used and also environmental problems caused by solvent removal in the wet coating process. When the ratio of needle coke to pitch was 8 : 2 wt%, and the rapid crush/coating process was carried out, it was confirmed that the fracture surface was coated by pitch. The pitch-coated sample was treated at 2400 ℃ and 41.8% improvement in 10C/0.1C rate characteristic was observed. It is considered that the material simply manufactured through the simple crush/coating process can be used as an anode electrode material for a lithium ion battery.

Implementation of Low Frequency Welding Pre-heating System Using Induction Heating (유도가열 기법을 이용한 저주파 용접예열 시스템 구현)

  • Yang, Juyeong;Kim, Soochan;Park, Junmo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.2
    • /
    • pp.61-67
    • /
    • 2018
  • Welding preheating means that the surface of the base material to which the metal is welded before the main welding is heated to a constant temperature. It prevents the cracks of the adjacent influences such as reduction of material hardening degree by controlling the cooling rate, suppression of segregation of impurities, prevention of thermal deformation, and moisture removal. For this reason, it is a necessary operation for high quality welding. Induction heating is an efficient heating method that converts electric energy into heat energy by applying electromagnetic induction phenomenon. Compared with combustion heat generated by gas and liquid, it is clean, stable, and economical as well as rapid heating. It can be heated regardless of the shape, depth and material of the heating body by modifying the shape of the frequency and the coil with a simple structure. In this paper, we implemented a low frequency welding preheating system using induction heating technique and observed the temperature changes of coil resistance, inductance and automotive transmission parts according to the height of each transmission in winding coil for three kinds of automotive transmission parts. We confirmed that the change of current is a very important factor in the low frequency heating.

Estimating Groundwater Level Variation due to the Construction of a Large Borrow Site using MODFLOW Numerical Modeling (대규모 토취장 개발 예정 지역의 수치모델을 이용한 지하수위 변동 예측)

  • Ryu, Sanghun;Park, Joonhyeong;Kim, Gyoobum
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.10
    • /
    • pp.15-23
    • /
    • 2012
  • A numerical model and field monitoring data are used to estimate a change in groundwater level at a borrow site, which will be constructed at the mountainous area with a large ground excavation in the study area, Hwaseong city. Lithologic data and hydraulic coefficients are collected at 9 boreholes and also groundwater levels are measured at these boreholes and existing wells in the study area. Additionally, groundwater recharge rate for the type of land cover is estimated using water budget analysis; 133.34mm/year for a mountainous area, 157.68mm/year for a farming area, 71.08mm/year for an urbanized area, and 26.06mm/year for a bedrock exposure area. The change in groundwater level in and around a borrow site is simulated with Modflow using these data. The result of a transient model indicates that a removal of high ground (over 40El.m) by an excavation will produce a decrease in groundwater levels, up to 1 m, around a borrow site in 10 years. It also explains that this ground excavation will bring about the decreases of 9.4% and 7.0% for groundwater recharge and surface runoff, respectively, which are the factors causing groundwater level's change. This study shows that it is required to construct the groundwater monitoring wells to observe the change of groundwater near a borrow site.

The Clinical and Pathologic Features according to Expression of Acyl Protein Thioesterase-1 (APT1) in Stage I Non-small Cell Lung Cancer (제1기 비소세포폐암에서 APT1 발현의 임상적 의미)

  • Shin, Jung-Ar;Lee, Chang-Ryul;Byun, Min-Kwang;Chang, Yoon-Soo;Kim, Se-Kyu;Chang, Joon;Ahn, Chul-Min;Kim, Hyung-Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.68 no.4
    • /
    • pp.212-217
    • /
    • 2010
  • Background: Acyl protein thioesterase-1 (APT1) is a cytosolic protein that may function in the depalmitoylation of numerous proteins, including the Ras family. However, the clinical role of depalmitoyl thioesterase in human cancer is not known. We evaluated the APT1 expression in lung cancer tissue and its clinicopathological findings according APT1 expression pattern. Methods: APT1 expression was examined by immunohistochemistry in the tumor tissue from 79 patients, who had undergone curative surgical removal of the primary lesion; all patients had been diagnosed with stage I non-small cell lung cancer between 1993 and 2004, at Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea. Results: The APT1 expression was seen in 50 out of 79 (63.3%) cases. The positive APT1 expression was significantly related with histologic subtype and T stage, but was not influenced by differentiation. The positive APT1 expression was not significantly related to patient age, gender, or smoking history. The median follow-up duration was 10.0 years; the 5-year survival rate was 71.0%. The positive APT1 expression group showed significantly worse overall survival and worse disease-free survival without statistical significance. Conclusion: We conclude that positive APT1 expression in stage I lung cancer after surgery is closely associated with overall survival. To evaluate APT1 as a prognostic marker in lung cancer, comprehensive studies on advanced stage cases are needed.

What Can We Apply to Manage Acute Exacerbation of Chronic Obstructive Pulmonary Disease with Acute Respiratory Failure?

  • Kim, Deog Kyeom;Lee, Jungsil;Park, Ju-Hee;Yoo, Kwang Ha
    • Tuberculosis and Respiratory Diseases
    • /
    • v.81 no.2
    • /
    • pp.99-105
    • /
    • 2018
  • Acute exacerbation(s) of chronic obstructive pulmonary disease (AECOPD) tend to be critical and debilitating events leading to poorer outcomes in relation to chronic obstructive pulmonary disease (COPD) treatment modalities, and contribute to a higher and earlier mortality rate in COPD patients. Besides pro-active preventative measures intended to obviate acquisition of AECOPD, early recovery from severe AECOPD is an important issue in determining the long-term prognosis of patients diagnosed with COPD. Updated GOLD guidelines and recently published American Thoracic Society/European Respiratory Society clinical recommendations emphasize the importance of use of pharmacologic treatment including bronchodilators, systemic steroids and/or antibiotics. As a non-pharmacologic strategy to combat the effects of AECOPD, noninvasive ventilation (NIV) is recommended as the treatment of choice as this therapy is thought to be most effective in reducing intubation risk in patients diagnosed with AECOPD with acute respiratory failure. Recently, a few adjunctive modalities, including NIV with helmet and helium-oxygen mixture, have been tried in cases of AECOPD with respiratory failure. As yet, insufficient documentation exists to permit recommendation of this therapy without qualification. Although there are too few findings, as yet, to allow for regular andr routine application of those modalities in AECOPD, there is anecdotal evidence to indicate both mechanical and physiological benefits connected with this therapy. High-flow nasal cannula oxygen therapy is another supportive strategy which serves to improve the symptoms of hypoxic respiratory failure. The therapy also produced improvement in ventilatory variables, and it may be successfully applied in cases of hypercapnic respiratory failure. Extracorporeal carbon dioxide removal has been successfully attempted in cases of adult respiratory distress syndrome, with protective hypercapnic ventilatory strategy. Nowadays, it is reported that it was also effective in reducing intubation in AECOPD with hypercapnic respiratory failure. Despite the apparent need for more supporting evidence, efforts to improve efficacy of NIV have continued unabated. It is anticipated that these efforts will, over time, serve toprogressively decrease the risk of intubation and invasive mechanical ventilation in cases of AECOPD with acute respiratory failure.

The Optimization of Ozone Solubility and Half Life Time in Ultra Pure Water and Alkaline Solution on Semiconductor Wet Cleaning Process (반도체 습식 세정 공정 중 상온의 초순수와 염기성 수용액 내에서 오존의 용해도 최적화)

  • Lee Sang-Ho;Lee Seung-Ho;Kim Kyu-Chae;Kwon Tae-Young;Park Jin-Goo;Bae So-Ik;Lee Gun-Ho;Kim In-Jung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.4 s.13
    • /
    • pp.19-26
    • /
    • 2005
  • The process optimization of ozone concentration and half life time was investigated in ultra pure water and alkaline solutions for the wet cleaning of silicon wafer surface at room temperature. In the ultra pure water,. the maximum concentration (35 ppm) of ozone was measured at oxygen flow rate of 3 liters/min and ozone generator power over 60%. The half life time of ozone increased at lower power of ozone generator. Additive gases such as $N_2$ and $CO_2$ were added to increase the concentration and half life time of ozone. Although the maximum ozone concentration was higher with the addition of $N_2$ gas, a longer half life time was observed with the addition of $CO_2$. When $NH_4OH$ of 0.05 or 0.10 vol% was added in DI water, the pH of the solution was around 10. The addition of ozone resulted in the half life time less than 1 min. In order to maintain high pH and ozone concentration, ozone was continuously supplied in 0.05 vol% ammonia solutions. 3 ppm of ozone was dissolved in ammonia solutions. The static contact angle of silicon wafer surface became hydrophilic. The particle removal was possible alkaline ozone solutions. The organic contamination can be removed by ozonated ultra pure water and then alkaline solution containing ozone can remove the particles on silicon surface at room temperature.

  • PDF