• Title/Summary/Keyword: Removal Efficiency

Search Result 4,214, Processing Time 0.029 seconds

A Study on the Limiting Factors in Wastewater Treatment by Contact Oxidation Process (접촉담화공정에 의한 폐수처이에 있어서의 제한요권에 관한 연구)

  • 황상용;손종열;우완기
    • Journal of environmental and Sanitary engineering
    • /
    • v.5 no.2
    • /
    • pp.45-52
    • /
    • 1990
  • This study is to discuss limiting factors influenced on the removal efficiency of organic materials investigated using the polypropyrene biofilter which appropriate to attach micro-organism in order to apply the contact oxidation proce,:5. The results obtained in the experiment were as follows : 1. In the range o: pH 4.0~ 12.0 was obtained the removal efficiency of COD higher than 85% It was proved that variation of pH(4.0 ~ 12.0) was nothing to do with the removal efficiency of substrate in continuous reactor. 2. Temperature to obtain removal efficiency of COD higher than 85% was $10^{\circ}$ ~$40^{\circ}$. Removal efficiency of COD was no less than those at high temperature if MLVSS concentration was maintained 8,000~ 15,000 m/1. 3. In the continuous reactor, the volumetric loading of COD for removal efficiency higher than 95% had to be 0.5~1.5 kg COD/.d below. And then the HRT was Bhrs. 4. In comparison with the conventional activate sludge process, the contact oxidation process was excellent in removal efficiency, sludge production rate and maintenance.

  • PDF

Studies on the Water Purification Using Glycine max Merr Seedling (콩(Glycine max Merr)유묘를 이용한 수질정화에 관한 연구)

  • 김순진;나규환
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.1
    • /
    • pp.50-54
    • /
    • 1997
  • The removal efficiency of nutrient was investicated by using Glycine max Meer seedling. After budding, Glycine max Merr was raised at darkness for 4 days. During cultivation, the removal efficiency of $NO_2-N+NO_3-N$ was up to 90% with initial concentration of 20-100 ppm. The removal efficiency of PO$_4$-P was up to 80% with initial concentration at 30 ppm, but it was down to 22% and 27% at 40 ppm and 50 ppm. When the removal efficiency of nutrient was compared with alternating 12 hours' light and darkness, the removal efficiency of NO$_2$-N + NO$_3$-N was up to 90% at below 60 ppm. It was not different from each other. But it was particularly low about 62% and 34% at 80 ppm and 100 ppm in alternating 12 hours' light. The removal efficiency of PO$_4$-P was low at alternating 12 hours' light between 10-50 ppm on the whole range. The neutralizing capacity of pH was shown in acidity and alkalinity except strong acidity(below pH 3). The initial pH was neutralized at 6.0-7.7 of pH after 4 days. Particularly, Glycine max Meer seedling that was difference from other water plants, was shown the neutralizing capacity in strong alkalinity.

  • PDF

The Effects of HRT, MLSS and DO on Nitrogen Removal Efficiency in MBR Process with Internal Baffle (내부 Baffle을 설치한 MBR 공정에서 HRT와 MLSS농도, DO농도 변화가 질소제거 효율에 미치는 영향)

  • Whang, Gye-Dae;Park, Joo-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.527-537
    • /
    • 2009
  • Three sets of parallel MBRs (reactor No.1, reactor No.2, reactor No.3) maintaining an MLSS of 4,000 mg/L, 6,000 mg/L and 8,000 mg/L, respectively, were operated to investigate the effect of various HRTs and DO concentration of MBRs on the removal efficiency of organic matters and nitrogen. The HRTs were operated on 4 hr, 6 hr, 8 hr. DO concentrations were ranged 1.5~2.0 mg/L and 0.5~1.0 mg/L respectively on each HRT conditions. MBR was divided into an aerated part and non-aerated part by baffle placed under the water. DO concentrations were controlled by altering the position of baffle. In terms of TSS and CODCr, all systems had a similar level of the removal under varied HRTs and MLSS. TSS removal efficiency was more than 99% and CODCr removal was ranged 94~97% under all conditions. Under the same condition on the HRT and MLSS concentrations, DO concentrations did not affect the organic removal efficiency. On the nitrification efficiency, with high DO concentration, as HRT or MLSS increased, the slight increment of nitrification efficiency was observed. However, under the low DO concentration, increase of MLSS and HRT resulted in larger increase of the nitrification efficiency. At the same HRT and MLSS, the nitrification efficiency increased greatly with up to 16% as DO increased. When the HRT increased from 4hr to 8hr, the denitrification efficiency slightly increased under most of conditions. However, the increase of MLSS resulted in about 19~39% denitrification efficiency increment. MLSS concentrations showed great effect on the denitrification. The increase of the DO concentration at the same HRT and MLSS resulted in decrease of denitrification efficiency with up to 27%. In all systems, the denitrification efficiency had more influence on the TN removal efficiency than nitrification efficiency. So, MLSS concentration has greater effect on the TN removal than HRT and DO. The TN removal efficiency increased as MLSS increased with up to 37%. As a result, the highest TN removal efficiency was observed 79.0% at the condition showed the highest denitrification efficiency that DO of 0.5~1.0 mg/L, an HRT of 8 hr, and 8,000 mg/L of MLSS concentration were maintained.

Phosphorus Removal from Synthetic Wastewater by Waste Oyster Shells (폐굴껍질에 의한 합성폐수 중의 인 제거)

  • 정경훈;정오진;최형일
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.43-49
    • /
    • 2000
  • A laboratory experiments were performed to investigate the effects of several factors on the phosphorus removal by waste oyster shells. The waste oyster shells used in this experiments were crushed particle, calcined particle and extracted solution. A higher efficiencies of phosphorus removal were observed, when a particle size of crushed and calcined particle were smaller. The effluent concentration of phosphorus was around 1.6mg/ι in continuous column experiment which packed with crushed particle of waste oyster shell at the influent concentration of PO4-P of 10 mg/ι. But the clogging of column occurred with increasing of throughput volume of influent. The efficiency of phosphorus removal increased with increasing of dosage amount of crushed, calcined particle and extracted solution. When the calcined particle which contained only about 1/10~1/100 of crushed particle was used, the efficiency of phosphorus removal was correspondingly equivalent to the removal efficiency obtained from crushed particle. The efficiency of phosphorus removal by calcined particle after 9 runs repeated use was decreased about 21.5% as that of the first run. The removal efficiency of 100% could have been achieved at the HRT of 18 hours during the continuous treatment of phosphorus by the solution extracted from calcined particle.

  • PDF

Characteristics of Organic Compounds Removal and Microbe Attachment in Packed Bed Column Reactor Using Surface-modified Media (표면개질 담체를 이용한 충전탑 반응기에서 유기물 제거 및 미생물 부착 특성)

  • Seon, Yong-Ho
    • KSBB Journal
    • /
    • v.27 no.3
    • /
    • pp.145-150
    • /
    • 2012
  • This study was accomplished using packed bed column reactors that contain nonsurface-modified polypropylene media and surface-modified media from hydrophobic surface property into hydrophilic property by ion beam irradiation. The objectives of this research was investigated the characteristics of organic compounds removal and microbe attachment from sewage of school cafeteria in these reactors. In 736.8 mg/L of the average inflow $COD_{Cr}$ concentration the reactors with and without surface modification showed 81.8% and 70.3% of average $COD_{Cr}$ removal efficiencies, respectively, which proves the $COD_{Cr}$ removal efficiency of surface-modified media reactor is higher than that of nonsurface-modified media reactor. After 90 days, there were maximum differences between modified system and non-modified system. In that time the maximum removal efficiency of $COD_{Cr}$ was 96.5% in modified system and was 85.2% in non-modified system that showed removal efficiency of surface-modified media system is 11.3% higher than that of nonsurface-modified media system. The average removal efficiency of SS was 80.4% for the surface modified system and 61.6% for the non-modified system under same condition. Also, the reactor of surface-modified media has advantage on microbe attachment and biofilm formation.

The Effects of DO, HRT, and Media Packing Ratio on Nitrogen Removal Efficiency in BCM-ASR System (고정상 담체를 충전한 활성슬러지 공정에서 DO농도와 HRT 및 담체 충전율 변화가 질소 제거효율에 미치는 영향)

  • Whang, Gye-Dae;Han, Bong-Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.659-669
    • /
    • 2008
  • Two sets of four parallel activated sludge reactors (ASRs) maintaining an MLSS of 3000 mg/L were operated to investigate the effect of DO, HRTs and bio-contact media (BCM) packing ratios on the removal efficiency of organic matters and nitrogen. Packing ratios of BCM to BCM-ASR systems 1, 2, 3, and 4 were 0% (suspended growth only), 10%, 15% and 20%, respectively. All systems were operated at an HRT of 4 hr, 6 hr, and 8 hr, respectively; DO concentration was maintained 0.5~1.0 mg/L and 1.5~2.0 mg/L for each HRT condition. In terms of TSS, TCODcr and SCODcr removal efficiency, all systems had a similar level of the removal efficiency under varied HRTs, and DO. But organic removal efficiency of systems with BCM was approximately 3~5% higher than systems without BCM at the same HRT and the DO. About the nitrification efficiency, with high DO (1.5~2.0 mg/L), as HRT (4 hr, 6 hr, 8 hr) or BCM packing ratio increased, the slight increment of nitrification efficiency was observed. However, under the low DO (0.5~1.0 mg/L), increase of BCM packing ratio and HRT resulted in large increase of the nitrification efficiency. At the same HRT and BCM packing ratio, the nitrification efficiency increased greatly with up to 15% as DO increased. When the HRT increased from 4hr to 8hr, the denitrification efficiency slightly increased by 5~10% only, under all DO conditions. Systems with BCM had higher denitrification efficiency, ranged 62.7~91.1% than systems without BCM showed 32.1~65.6%. And the increase in BCM packing ratio from 10% to 20% resulted in about 14~16% denitrification efficiency increment. BCM packing ratio showed great effect on the denitrification. The increase of the DO (from 0.5~1.0 mg/L to 1.5~2.0 mg/L) at the same HRT and BCM packing ratio resulted in slight decrease of denitrification efficiency with up to 7% for systems with BCM. But for systems without BCM, the denitrification efficiency decreased with up to 28%. In all system, the denitrification efficiency had more influence on the TN removal efficiency than nitrification efficiency. So, BCM packing ratio (0%, 10%, 15%, 20%) has greater effect on the TN removal than HRT and DO. The TN removal efficiency increased as packing ratio of BCM increased with up to 45%. As a result, the highest TN removal efficiency was observed 73.7% at the condition showed the highest denitrification efficiency that DO of 0.5~1.0 mg/L, an HRT of 8 hr, and 20% of BCM packing ratio was maintained.

Effects of Operating Parameters on Toluene Removal in Dielectric Barrier Discharge Process (무성방전내에서 톨루엔 제거에 미치는 운전변수의 영향)

  • 정재우;이용환;박경렬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.3
    • /
    • pp.173-182
    • /
    • 2002
  • We investigated the effects of operating variables, such as electrical. reactor and gas parameters on toluene removal and discharge property in the dielectric barrier discharge (DBD) process. The toluene removal was initiated with the energy transfer to the reactor by loading of voltages higher than the discharge onset value. The energy transfer and toluene removal increased with the applied voltage. Higher removal rate was observed with smooth surface electrode despite of lower energy transfer compared with the coarse electrode, because more uniform discharge can be obtained on smooth surface state. The decrease of dielectric material thickness enhanced the removal efficiency by increasing the discharge potential. The toluene removal efficiency decreased with the increase of the inlet concentration. The increase of gas retention time enhanced the removal efficiency by the increase of energy density. The oxygen and humidity contents seem to exert significant influences on the toluene removal by dominating the generation of electrons, ions, and radicals which are key factors in the removal mechanism.

Treatment Efficiency and Organic Matter Characterization of Wastewater through Activated Sludge Process and Advanced Wastewater Treatment Process (활성슬러지공정과 고도처리공정에 따른 하수처리수의 처리효율과 유기물 특성)

  • Hong, JiHea;Sohn, Jinsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.6
    • /
    • pp.807-813
    • /
    • 2004
  • Wastewater was treated by two different treatment processes; activated sludge process and advanced wastewater treatment process (KNR process) using lab-scale experiment. Two treated wastewater showed good treatment efficiency of organic matter removal, up to 90% removal. Nitrogen and phosphorus were not effectively removed though activated sludge process, while KNR process showed good removal efficiency of nitrogen and phosphorus; 56% nitrogen removal and 95% phosphorus removal. KNR process showed better removal efficiency of organic matter, nitrogen, and phosphorus compared to activated sludge process. Organic matter characterization was tracked though measurement of UV scan, SUVA, and XAD fractionation. Treated wastewater showed higher SUVA value than wastewater influent, indicting less aromatic characteristic of organic matter. XAD fractionation showed hydrophilic fraction decreased though wastewater treatment, suggesting microbes preferentially digest hydrophilic and aliphatic molecules rather than hydrophobic and aromatic molecules of organic matter.

Heavy Metal Removal from Drinking Water using Bipolar Surface Modified Natural Mineral Adsorbents (천연광물의 양극성 표면개질을 이용한 상수원수 중 중금속제거 특성)

  • Kim, Nam-youl;Kim, Younghee
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.6
    • /
    • pp.561-568
    • /
    • 2019
  • Objectives: The most commonly detected heavy metals in rocks and soils, including Pb, Cd, Cu, Fe, Mn and As, are representative pollutants discharged from abandoned mines and have been listed as potential sources of contamination in drinking water. This study focused on increasing the removal efficiency of heavy metals from drinking water resources by surface modification of natural adsorbents to reduce potential health risks. Methods: Iron oxide coating and graft polymerization with zeolites and talc was conducted for bipolar surface modification to increase the combining capacity of heavy metals for their removal from water. The removal efficiency of heavy metals was measured before and after the surface modification. Results: The removal efficiency of Pb, Cu, and Cd by surface modified zeolite showed 100, 92, and 61.5%, respectively, increases compared to 64, 64, and 38% for non-modified zeolite. This implies that bipolar surface modified natural adsorbents have a good potential use in heavy metal removal. The more interesting finding is the removal increase for As, which has both cation and anion characteristics showing 27% removal efficiency where as non-modified zeolite showed only 2% removal. Conclusions: Zeolite is one of the most widely used adsorptive materials in water treatment processes and bipolar surface modification of zeolite increases its applicability in the removal of heavy metals, especially As.

A Study on Removal of Nitrogen at Sewage Treatment using Solar Energy (Solar Energy를 이용한 하수처리의 질소 제거에 관한 연구)

  • Hwang, Yong Ha
    • Journal of Institute of Convergence Technology
    • /
    • v.1 no.2
    • /
    • pp.37-42
    • /
    • 2011
  • The purpose of this research is to improve nitrogen removal efficiency in winter season through rise of water temperature of extraneous water by using solar energy which is estimated to have great potential among new regeneration energy and while operating Plug-Flow Reactor to improve nitrogen removal efficiency by selecting A/O process among sewage waste water treatment processes as the necessity of solving the problem of nitrogen removal efficiency according to reduced water temperature in winter season and strengthening of water quality criteria regarding discharged sewage waste water suggested in the research background. Summarizing the research result, supply of solar energy source improves the function outstandingly when removing nitrogen, (nitrogen removal rate before operating solar energy 55.4% ${\rightarrow}$ nitrogen removal rate after operating solar energy 84.1%).

  • PDF