• Title/Summary/Keyword: Removable partial denture

Search Result 219, Processing Time 0.027 seconds

A case of treatment denture and implant-assisted removable partial denture in a patient with collapsed occlusion caused by partial loss of posterior and anterior teeth (편측 구치 및 전치 상실로 인한 교합 붕괴 환자에서 치료 의치와 임플란트 보조 국소의치를 이용한 수복 증례)

  • Ahn, Hye-Bin;Lee, Keun-Woo;Lee, Yong-Sang;Yim, Sun-Young;Kim, Sung Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.110-118
    • /
    • 2022
  • Multiple tooth loss can cause disharmonious occlusial plane, loss of vertical dimension and deflection of mandibular movement. Therefore, restoring proper vertical dimension and occlusion in the centric relation is an important treatment goal. Implant-assisted removable partial denture is a recently used clinical technique, because it increases patient satisfaction by improving retention, support, and stability of conventional denture. The objective of this article is to present a case report describing the fabrication of treatment denture and implant assisted removable partial denture using previously placed implants for a patient with partial loss of posterior support and anterior stop.

A study of the EQ-5D index according to the dental prostheses status of the elderly in Korea (한국 노인의 치과보철 상태에 따른 건강 관련 삶의 질에 관한 연구)

  • Hwang, Hong-Gu;Lee, Jong-Hwa
    • Journal of Technologic Dentistry
    • /
    • v.43 no.1
    • /
    • pp.19-28
    • /
    • 2021
  • Purpose: This study aimed to obtain basic data on oral health improvement by investigating the EQ-5D index according to the oral prosthesis status of elderly persons aged 65 years or older in Korea using the Seventh Korea National Health and Nutrition Examination Survey. Methods: In this study, 3,426 elderly persons aged 65 years or older were included to analyze the relationship between the dental prostheses status and EQ-5D index in the collected data. Results: Compared to the "complete denture" in oral prosthesis, EQ in case of no dental prostheses or fixed dental prostheses is comparable to removable prosthetics such as "no dental prostheses," "one fixed bridge," and "two or more fixed bridges." Removable partial denture and complete denture required for the maxillary and mandibular EQ-5D index were significantly higher in "not necessary" than in "complete denture necessary" in all the elderly persons. Conclusion: The condition of the dental prosthesis and the need for a removable partial denture and complete denture for the elderly's EQ-5D index were confirmed, and it was found that the fixed dental prostheses were more effective than the removable dental prostheses. Therefore, oral health education programs for the elderly should be developed to promote dental function and oral health maintenance.

A PHOTOELASTIC STRESS ANALYSIS IN MANDIBULAR DISTAL EXTENSION REMOVABLE PARTIAL DENTURE DESIGNED UNILATERALLY WITH DIFFERENT DIRECT RETAINERS (편측성으로 설계된 하악 유리단 국소의치에서 직접유지장치의 설계 변화에 따른 광탄성 응력 분석에 관한 연구)

  • Son Hong-Suk;Kay Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.1
    • /
    • pp.25-42
    • /
    • 1992
  • The purpose of this study was to analyze the magnitude and distribution of stress using a photoelastic model from a unilateral distal extention removable partial dentures with five kinds of the direct retainers, that is, the bilaterally designed bar clasp of the cross-arch lingual bar and the unilaterally designed bar clasp, circumferential clasp, mini-Dalbo attachment, and telescope retainer. A photoelastic model for mandible was made of the epoxy resin(PL-1) and hardner (PLH-1) with the acrylic resin teeth used and was coated with plastic cement-1 at the lingual surface of the model, and then five kinds of removable partial dentures were set, A unilateral vertical load of about 16Kg was applied on the first molar and the stress pattern of the photoelastic model under each condition was analyzed by the reflective circular polariscope. The following results were obtained: 1. The conventional removable partial denture with the bilaterally cross arch lingual bar produced the most favorable stress distribution on the residual ridge and supporting structure of abutment teeth than the unilaterally designed removable partial dentures. 2. The unilaterally designed removable partial denture with the bar clasp produced the stress distribution on the residual ridge, except sligtly higher stress concentration on the supporting structure of the abutment teeth, similar to the conventional removable partial denture with the bilaterally designed cross arch lingual bar. 3. On the unilaterally designed removable partial dentures, the bar clasp produced greater stress distribution on the residual ridge and supporting structure of the abutment teeth than the circumferential clasp. 4. On the unilaterally designed removable partial dentures, the mimi-Dalbo attachment produced relatively higher stress concentration on the residual ridge, but produced lesser stress concentration on the supporting structure of the abutment teeth than the other direct retainers. 5. On the unilaterally designed removable partial dentures, the telescope retainer produced uniform stress distribution on the residual ridge, but produced higher stress concentration at the root apex of the terminal abutment tooth than the other direct retainers. 6. On the unilaterally designed removable partial dentures the circumferential clasp and telescope retainer produced slightly higher stress concentration on the residual ridge and supporting structure of the abutment teeth than the bar clasp and mini- Dalbo attachment.

  • PDF

Initial Placement of Removable Partial Dentures (가철성 국소의치의 장착)

  • Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.299-307
    • /
    • 2013
  • The overall objective of fitting removable partial dentures at initial placement is to ensure that the patient is given the best possible start with the new prostheses. This may be achieved by checking that: (1) final inspection of the prosthesis, (2) seating of the RPD framework, (3) evaluation of denture base adaptation, (4) assessment of denture base peripheral extensions, (5) occlusal adjustment, (6) remounting the prosthesis, and (7) instructions to the patient.

Rehabilitation of Partial Edentulism with a Crown-type Implant-assisted Removable Partial Denture through Guided Implant Surgery: A Case Report with a 12-month Follow-up

  • Jun, Ji Hoon;Oh, Kyung Chul;Li, Jiayi;Moon, Hong Seok
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.75-83
    • /
    • 2022
  • Crown-type implant-assisted removable partial dentures (CIRPDs) can be a feasible treatment option for partially edentulous patients. Here we report a case with remaining unilateral mandibular teeth. Two implants were placed in the posterior portion of the mandible using a surgical guide, and a distal-extension removable partial denture with implant-supported surveyed crowns was fabricated. After 12 months, both the abutment teeth and implants were in good condition. The treatment outcomes were satisfactory in terms of masticatory function and esthetics. The advantages of CIRPDs and considerations for obtaining successful clinical outcomes with these dentures are also discussed.

PHOTOELASTIC STRESS ANALYSIS ON THE SUPPORTING TISSUE OF MANDIBULAR DISTAL EXTENSION REMOVABLE PARTIAL DENTURE WITH VARIOUS DESIGN OF DIRECT RETAINERS (직접유지장치 설계 변화에 따른 하악 후방연장 국소의치 지지조직의 광탄성 응력분석)

  • Lee Chang-Ho;Kim Kwang-Nam;Chang Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.2
    • /
    • pp.203-224
    • /
    • 1992
  • The purpose of this study was to evaluate the stress distribution developed in supporting structures by distal extension removable partial denture with 4-types of direct retainer. The direct retainers examined were Akers clasp, RPI clasp, RPA clasp and RPL clasp in bilateral & unilateral free end case. 3-dimensional photoelastic stress analysis was used to record the isochromatic fringe patterns and to calculate the compressive stress at measuring points. The results were as follows. 1. In bilateral free end case, RPI clasp exhibited the similar stress distribution on distal and mesial alveolar crest but Akers clasp exhibited higher stress concentration on distal alveolar crest than mesial alveolar crest. 2. In bilateral free end case, RPA clasp and RPL clasp exhibited the similar stress distribution on distal and mesial alveolar crest and RPL clasp exhibited higher stress concentration on buccal alveolar crest than lingual alveolar crest. 3. Akers clasp produced high stress concentration on residual alveolar ridge distally, but RPI clasp, RPA clasp and RPL clasp produced even stress distribution on residual alveolar ridge. 4. Removable partial denture in unilateral free end case exerted higher stress on abutment tooth root apex than bilateral distal extension removable partial denture.

  • PDF

The Fabrication of Accurate Removable Partial Denture by Analyzing the Failed Cases (실패 증례 분석을 통한 국소의치 제작 시 주의사항)

  • Lee, Ji-Young;Lee, Kyoung-Lok;Heo, Yu-Ri;Son, Mee-Kyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.280-289
    • /
    • 2013
  • Removable partial denture for oral function recovery of partial edentulous patients is a complicated treatment because the dentist should consider both hard tissue and soft tissue. Removable partial denture produced without consideration of precise design for each component and rotation of denture may cause fracture, deformation or loss of abutment teeth. In case of failure to achieve a proper denture, the reason of failure should be analyzed and the result must be applied to later RPD cases. Finding the solutions through the failed denture cases will help patients use their dentures more comfortably and keep their sound residual teeth and tissue longer.

A case of removable partial denture restoration using implant supported surveyed crown in a maxillary edentulous patient (상악 무치악 환자에서 임플란트 지지 서베이드 크라운을 이용한 가철성 국소의치 수복 증례)

  • Seong, Si Young;Choi, Yeon Jo;Ryu, Jae Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.29-36
    • /
    • 2022
  • When planning oral rehabilitation for maxillary edentulous patients, fixed prosthetic restoration using implants, complete denture restoration or overdentures using implants can be considered as treatment methods. In the case of complete denture restoration, it does not require additional surgery and is relatively economical. In the case of implant-supported fixed prostheses, the functional part is generally superior to that of complete denture restoration, but there are cases in which implant placement is clinically difficult. Recently in consideration of the patient's needs and the condition of the remaining alveolar bone, after partial implant placement, a method of restoring with a removable partial denture using implant-supported surveyed crown is also being attempted. This case is a case of performing a removable partial denture restoration using implant-supported surveyed crown in the anterior maxilla, and showing satisfactory esthetic and functional results.

Effect of Suprabulge Clasp and Infrabulge Clasp on the Mobility of Abutment Teeth for Distal Extension Removable Partial Dentures (유리단 국소의치에서 Suprabulge Clasp와 Infrabulge Clasp가 지대치 동요에 미치는 영향에 관한 연구)

  • Yim, Soon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.19 no.1
    • /
    • pp.39-45
    • /
    • 1981
  • Distal-extension removable partial dentures have long been implicated in the increase in mobility and the destruction of the supporting structures of the primary abutment teeth. Various clasping systems have traditionally been used to retain distal extension removable partial dentures, and other designs have been proposed to minimize torquing forces on the abutment teeth. Most recent studies investigating the effects of removable partial dentures on abutment teeth have been performed in it laboratory setting. Results obtained from in vitro research have given dentists insight into removable partial denture design, but laboratory test model cannot be constructed that simulates actual functional or parafunctiona1 movements and forces. The purpose of this study was to clinically evaluate the degree of tooth mobility produced by two clasping systems (suprabulge type and infrabulge type) used for distal extension removable partial dentures. Akers clasp and R.P.I. system were selected for the evaluation, and four patients required a distal extension removable partial denture on the mandibular arch were selected for participation in the study. Two partial dentures were constructed in the same condition expect the design of clasp. All abutments in the study were mandibular first or second premolars. Measurements of mobility were made with a research tool designed by $M\"{u}hlemann$. This instrument, periodontometer, measures tooth mobility in the mouth by means of a dial gauge accurated to 0.01mm when the tooth is stressed with a force meter. Lingual and buccal deflection of abutment tooth was measured using buccal and lingual pressure. The amount of force applied was 500gm. Tooth mobility tests were made at four key stages; 1. Before insertion of the first removable partial denture, baseline mobility was establsihed. 2. After wearing of the first prosthesis, measurement was made at weekly intervals for 4 weeks. 3. The removable partial denture was then taken from the patient, and tooth mobility was measured again at weekly intervals until the patient's established baseline mobility had returned. 4. The second prosthesis of different clasp design was worn for a month and evaluated in the same manner as the first. The sequence of placement of clasping system was alternated between patients. The following results were obtained from this study; 1. The mobility of abutment tooth increased during the initial stage of wear and returned to baseline mobility after removal of removable partial dentures. 2. The mobility of abutment tooth showed no difference between Akers clasp and I-bar clasp during the 4-week test period. 3. All teeth tested showed greater mobility toward the buccal than the lingual direction.

  • PDF

Cr-Co removable partial denture treatment fabricated by selective laser melting: a case report (Selective Laser Melting을 이용한 코발트-크롬 가철성 국소의치의 수복 증례)

  • Yim, Ji-Hun;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.1
    • /
    • pp.39-47
    • /
    • 2021
  • Compared to conventional method, if metal framework of removable partial denture is fabricated by selective laser melting, various laboratory works are omitted, saving time and simplifying the process. In addition, metal framework with homogeneous density can be obtained, expecting excellent mechanical properties, especially resistance to fatigue fracture. In these cases, impression were taken using conventional methods in partial edentulous patients, master casts were fabricated and scanned to obtain digital data. After designing the metal frameworks on the scanned data, removable partial dentures were fabricated using selective laser melting methods. Through these procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.