• Title/Summary/Keyword: Remote power management

Search Result 182, Processing Time 0.027 seconds

Development of AMI NMS (Network Management System) using SNMP for Network Monitoring of Meter Reading Devices (원격검침 설비의 네트워크 상태감시를 위한 SNMP 기반의 저압 AMI 망관리시스템 개발)

  • Kim, Young-Il;Park, So-Jeong;Kim, Young-Jun;Jung, Nam-Jun;Choi, Moon-Suk;Park, Byung-Seok
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.259-268
    • /
    • 2016
  • KEPCO installed AMI (Advanced Metering Infrastructure) metering system for low-voltage customers from 2008. AMI metering system of KEPCO has operated 2.55 million customers and will plan to operate 22 million customers until 2020. KEPCO developed AMI NMS (Network Management System) to operate the meter reading network efficiently. NMS monitors the network status of DCUs (Data Concentration Unit) and modems. NMS provides functionalities of data collection and analysis. It collects property data of network device, network topology information, communication performance information, fault information, and etc. It analyzes collected data and controls network devices by remote access. AMI NMS collects about 370 MIBs (Mangement Information Bases) using SNMP (Simple Network Management Protocol). This paper introduces main functionalities, designed context, and implemented service screen.

Security Monitoring System for Apartment House Building Using Paver Line Carrier (전력선 통신을 이용한 집단주택 안전관리 시스템)

  • Kim, In-Soo;Kim, Kwan-Ho;Kim, Yo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.476-478
    • /
    • 1993
  • Instead of installing new communication wiring to each house in the apartment house building. the power distribution network. which is already installed in the building. can be use as communication medium. In a safty management, by adoption of power line communication system, at remote we can monitor safty related sensors such as fire, gas leakage, burglar intrusion and emergency call which are located at each house. From this viewpoint, we developed security monitoring system for apartment house building using power lines. Security monitoring system consists of Power Line Communication-Sub Controller (PLC-SC). Power Line Communication-Main Controller (PLC-MC) and Management System (MS). Between a PLC-MC and a PLC-SC, the transmission rate is 1200 bps in power lines and modulation technique is frequency shirt keying (FSK). In between a PLC-MC and a MS, the transmission rate is 1200 bps in communication line (RS-485). As a result of this research. transmission loss is 0.1dB per meter of intrabuilding distribution network. Transmission can be reach in 250 meters. So it is enough to communicate for security monitoring system in apartment house building.

  • PDF

Satellite Remote Sensing for Forest Surveys and Management (산림조사(山林調査) 및 경영(經營)을 위(爲한) 위성원격탐사(衛星遠隔探査))

  • Choung, Song Hak
    • Journal of Korean Society of Forest Science
    • /
    • v.83 no.1
    • /
    • pp.75-87
    • /
    • 1994
  • The states of development of remote sensing, GIS and forest management technology are such that new directions in forest surveys and management are possible. The technologies can not be considered separately. With the increasing power and decreasing cost of computer processing and the development of inexpensive mass storage media, digital remote sensing applications are becoming more practical. Powerful microcomputer-based image analysis systems and GIS are important advancements. As well, it is only a matter of time before the integration of remote sensing image analysis systems and GIS becomes transparent to the users. Implementation of operational applications by both centralized agencies and local units is, therefore, becoming practical. This paper discussed the state of remote sensing technology and its application to forest surveys and management. The relative advantages and disadvantages of readily available remote sensing products for regional biodiversity assessment were summarized. Discussion is limited to the sources of up-to-date imagery suitable for regional land use/cover mapping, specifically : LANDSAT MSS and TM, and SPOT.

  • PDF

A Design of Advanced Distribution Management System Based on IT/OT Convergence (IT/OT Convergence 기반의 Advanced Distribution Management System의 설계)

  • Lim, Il-Hyung;Lee, Seung-Joo;Park, Jong-Ho;Shin, Yong-Hak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.753-759
    • /
    • 2016
  • Power automation system to operate power distribution systems can be distinguished by distribution SCADA with remote monitoring and control; and distribution automation system with basic functions such as service restoration to the distribution SCADA; and distribution management system which is operated by various applications in order to enhance distribution system operation performance based on the distribution automation system. In the technological change, a technical boundary of information technology (IT) and operation technology (OT) is being blurred by that new concepts such as interoperability. In addtion, IT/OT convergence has been proposed by the improvement of ICT and power system technology. At the viewpoint, advanced distribution management system (ADMS) to have the new concepts and to increase distribution system operation efficiency through global information and functions from the other systems has been proposed. In order to implement the ADMS, IT and OT have to be employed together on the ADMS; and the concept-based IT/OT convergence concept has been presented. Therefore, this paper introduces ADMS and IT/OT convergence and proposes a design of IT/OT convergence based ADMS system design with configurations and functions.

Design of New Smart Switch with Remote Power Control and Standby Power Management Function (원격 전력제어 및 대기전력 관리 기능을 갖는 새로운 스마트 스위치 설계)

  • Lee, Yong-An;Kim, Kang-Chul;Han, Seok-Bung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.10
    • /
    • pp.2343-2350
    • /
    • 2010
  • In this paper, new smart switch that can monitor and control the power consumption and standby power in real-time by implementing an embedded web-server is proposed. The proposed switch can perform the following functions: measuring the electric power like commercial smart meter product, monitoring the power consumption in real-time in distant places through wire and wireless devices, and finally controlling ON/OFF of each switch. In addition, it also contains auto power-shutoff functions for standy power, overvoltage and overcurrent just like existing power-saving outlet and mulitap. Finally, the proposed smart switch has lower hardware and power consumption than the existing products and can be commercialized as a small-sized product by using exclusive embedded web-server of its own, rather than using PC for monitoring and remote control.

The Development of an Optimal Management System for Industrial Batteries (산업용 축전지 최적 관리시스템 개발)

  • Min, Byoung-Gwon;Ryu, Seung-Pyo;Shin, Hyun-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1009-1011
    • /
    • 2002
  • Some defective cells in the battery bank of power systems using batteries result in deterioration of the performance of the total battery bank. Consequently, the battery bank can't perfectly back up the system in occurrence of any power problems and the overcharge of defective cells may lead to their explosion or the occurrence of fire. The developed battery management system in this study enables operators to telemeter and analyze internal resistance, voltages, currents, and temperatures of batteries at remote sites through a PC, so they can detect defective cells before the occurrence of power problems. And adoption of this system ensures extension of battery life.

  • PDF

Development of Electric Power Management System for Electric Furnace (전기로 전력관리 시스템 개발)

  • Min, Byeong-Yong;Kim, Ho-Jin;Kwon, Yong-Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.904-907
    • /
    • 2013
  • Demand Controller is a control device that if current electric power consumption seems to exceed the targeted amount of electric power, block the connected load devices. When this ON/OFF way is applied to electric power management of electric furnace, start and stop operation of inverter and an electric heater which supplying electric power is being performed repeatedly. This has a problem of life-shortening of inverter and an electric heater by electrical damage. In addition, when electric power supplying is blocked, attemperation is not allowed until return to normal operation condition. In this paper, we develop power management system for electric furnace using the electric furnace remote controller. This system provides the automatic control for approved electric power to electric furnace organically and prevent electric damage of inverter and an electric heater through continuous electric power supply within the targeted amount of electric power.

  • PDF

An Integrated Management System of the Educational Equipments and Contents of Secondary School (중등학교의 교육 기자재 및 콘텐츠 통합 관리 시스템)

  • Park, Sun Hwa;Park, Jae Heung;Seo, Yeong Geon
    • Journal of Digital Contents Society
    • /
    • v.16 no.2
    • /
    • pp.197-205
    • /
    • 2015
  • These days due to the introduction of the subject classroom system, the classrooms for the subject are arranged and various advanced educational equipment is provided in the classroom such as the actual object image processor, electronic blackboard, and educational photographer which are helpful to the class. With the increase of these equipments, the number of remote controller of individual educational equipment also increases, therefore it is complicate to manage the remote controllers and teachers need to learn the usage of them. So the system supports a remote control for managing the educational equipment by the one remote controller and the instructional supplement. The system consists of the hardware which is similar to popular remote controller and the software which is installed on the teacher's PC and supports controlling the educational equipments, recording the instruction, writing on the blackboard, and automatic power off of the equipment. By introducing the system the teacher could reduce the time consumed by the equipment's control and useless electric waste.

Airport Power Information System Design in the Inchon Inta'l Airport (인천국제공항 공항전력정보시스템 설계)

  • Oh, Y.D.;Min, S.J.;Lim, J.G.;Moon, J.H.;Lee, T.S.;Yun, T.H.;Kim, M.H.;Moon, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1121-1124
    • /
    • 1998
  • Inchon International Airport(IIA) is constructed for Northeast Asia Gate as is important for IIA to become a 21 century's leader in the world, as is planned for open at december 2000 as a important economic link for unified korea. Airport Power Information System(APIS) is designed through investigation of advanced domestic and international example. In addition to power facility operation it is designed for using an information infrastructure of whole airport. APIS is newly designed for uninterupted power supply, effective power management, information infrastructure's construction. making a profit by positively introduction of new technology for collection and conservation of power related data, correlation with airport infra systems, data interrelative arrangement about related systems like outdoor lighting system and automatic measuring record, CCTV systems for remote power facility monitoring, and promotion of management ability in the emergency status.

  • PDF

Fuzzy Logic Based Energy Management For Wind Turbine, Photo Voltaic And Diesel Hybrid System

  • Talha, Muhammad;Asghar, Furqan;Kim, Sung Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.5
    • /
    • pp.351-360
    • /
    • 2016
  • Rapid population growth with high living standards and high electronics use for personal comfort has raised the electricity demand exponentially. To fulfill this elevated demand, conventional energy sources are shifting towards low production cost and long term usable alternative energy sources. Hybrid renewable energy systems (HRES) are becoming popular as stand-alone power systems for providing electricity in remote areas due to advancement in renewable energy technologies and subsequent rise in prices of petroleum products. Wind and solar power are considered feasible replacement to fossil fuels as the prediction of the fuel shortage in the near future, forced all operators involved in energy production to explore this new and clean source of power. Presented paper proposes fuzzy logic based Energy Management System (EMS) for Wind Turbine (WT), Photo Voltaic (PV) and Diesel Generator (DG) hybrid micro-grid configuration. Battery backup system is introduced for worst environmental conditions or high load demands. Dump load along with dump load controller is implemented for over voltage and over speed protection. Fuzzy logic based supervisory control system performs the power flow control between different scenarios such as battery charging, battery backup, dump load activation and DG backup in most intellectual way.