• Title/Summary/Keyword: Remote check

Search Result 230, Processing Time 0.023 seconds

An Interactive Monitoring Application for Secure Experiments of Guidance System for Person with Visual Impairment (시각장애인 보행지원 시스템의 안전한 실험을 위한 대화식 모니터링 어플리케이션)

  • Lee, Jin-Hee;Lee, Eun-Seok;Shin, Byeong-Seok
    • Journal of the HCI Society of Korea
    • /
    • v.8 no.2
    • /
    • pp.1-8
    • /
    • 2013
  • In previous study, we developed a guidance system outdoors for person with visual impairment to be able to walk safely to the destination. The volunteers are exposed to dangerous situations since they are performed to the experiments in the outdoors. In order to solve the problem, we propose an interactive application that monitors the volunteer wearing guidance system and warns remotely the volunteer about dangerous situations. The application is used to remote wireless communication with guidance system through Bluetooth module that is built in a laptop computer, without additional device. Therefore, we can monitor in real time user's location and guided contents to user, and it is possible to check a path to the destination and POI (Point of Interest) coordinate values. As using a proposed monitoring application, it is possible to perform safe experiment with the rapid situation awareness and fast detection of dangerous.

  • PDF

Design and Implementation Testbed of Home Network based PLC (PLC 기반의 홈 네트워크 테스트베드 설졔 및 구현)

  • Kim, Hyeock-Jin;Han, Kuy-Ban;Jean, Byoung-Chan
    • Journal of the Korea Computer Industry Society
    • /
    • v.10 no.4
    • /
    • pp.143-150
    • /
    • 2009
  • Remote control service, monitoring, gear service of information electronic appliance, various services of security service and so on of Home network that is by link of Ubiquitous environment are offered. These services need verification process through priority test to use and are changed. If test using actuality information electronic device for test, much expenses and time may be invested. Home network test bed offers softness of research using control model and simulator, in this paper, Wish to design and embody home network test bed to do environment construction of home network and test of application service. Because use istent power line just as it is without necessity to establish circuit in addition by solution of home network testbed, expense costs to be less and establishment used easy PLC. Also, propriated Wireless sensor network that use Zigbee by solution of home network testbed. Appliance check and monitor square do by Home Auto that know embodied, and embodied by Home Gateway that interlink terminals of Home Auto and out of.

  • PDF

Analysis of sight deviation between the panelists and the camera of digital broadcasting (디지털 방송 카메라와 토론자 간의 시각 편차 해석)

  • Choi, Chul-Jae;Joo, Seok-Hum;Lee, Tae-Hee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.7
    • /
    • pp.835-840
    • /
    • 2014
  • In this paper, we analyze the visual deviation for the sight mismatch between the digital broadcast camera during shooting and panelists due to sideways frequently the digital stopwatch for panelists who participated in the election broadcast to check the time limit. Match the sight of the on-air broadcast camera discussion and participants in the debate, such as the small studio is relatively stable. However, if a large number of participants in the discussion and broadcasting of the forum is a serious sight deviation occurring by sideways large LCD monitor stopwatch that is installed in the center. Therefore, in this paper, the number of panelists, the length of the desk, to discuss the analysis of fair value changes in accordance with the height and distance the distance between the digital stopwatch, and digital broadcast camera.

Real-time measurement management system UI development linked the Water treatment facilities Broadband Convergence Network (수처리시설용 광대역 통합망 연계형 실시간 계측 관리 시스템 UI개발)

  • Yang, Seungyoun;Kim, Jintae;Oh, Hwanjin;Lee, Minwoo
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.4
    • /
    • pp.83-86
    • /
    • 2015
  • In this paper, we propose a real-tim measurement management system UI development linked the Water treatment facilities broadband Convergence Network. The sensor and the image data received by the server develop a program to interact with Web through water treatment facilities broadband convergence network. So, Separately develop UI capable of independently operating. Building a web server for remote monitoring of the transmission sensor and the image data. And Monitoring and control is possible the sensor data and image data through the Web-based UI. We can grasp the current state such as measurement time, concentration and depth of interface through the proposed real-time measurement management system UI development liked the water treatment facilities broadband convergence network. So, we can check in whether the normal operation of water treatment facilities and whether the casualties such as fire and security. As well as real time to see the information at a glance due to UI development can be raal-time monitoring of real-time measurement management system.

The Development of Cleaning and Monitoring System for Pipeline Type UV Sterilizer (관로형 UV 소독기를 위한 세척 및 모니터링 시스템 개발)

  • Park, Byeung-Jun;Ryu, Ji-Hyoung;Park, Jae-Byung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6434-6440
    • /
    • 2013
  • In this paper, an integrated control system is proposed for automatic control and remote monitoring of pipeline type UV sterilizer. The proposed system can control the cleaning wiper in the sterilizer with various cleaning motions, and periodically check the contamination level of the UV lamps with the UV power sensors. Therefore, sterilizer repair and maintenance can be more effectively done. In addition, the control system based on the open-source processor can communicate with external smart devices via Bluetooth, and thus wirelessly exchange control commands and sensor data. Furthermore, the system is able to flexibly cope with changes of cleaning motions and sensors since its firmware can be wirelessly upgraded by using the smart device. Consequently, the proposed system is suitable to construct a smart sewage treatment system in small towns.

Mobile Voice Note File Management Service For Improving Accessibility of the Blind (전맹인의 접근성 향상을 위한 모바일 음성 메모 파일 관리 서비스)

  • Lim, Soon-Bum;Lee, Mi Ji;Choi, Yoo Jin;Yook, Juhye;Park, Joo Hyun;Lee, Jongwoo
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.11
    • /
    • pp.1215-1222
    • /
    • 2019
  • Recently, people with disabilities also search for and collect information from the web through smart devices, and save collected information on smart devices or take notes. For non-disabled people, various memo applications are provided on the market, so it is more convenient to choose according to their preference. However, existing memo services are limited for use by blind people due to the importance of visual information. The problem with blind people when using smart devices is that the screen is not recognized, so it is not possible to check in which location the menu of the application exists. In addition, it is difficult to input and manipulate text, and systematic file management and control are not possible. Therefore, in this paper, we propose the development of voice memo service that blind people can use only voice and hearing information and can operate menu with Bluetooth remote controller. We will develop a system that includes a comprehensive voice file management function for storing, searching, playing, and deleting files, rather than simply storing voice files.

A Study of Evaluation Certification on Electronic Power u-IT Convergence Equipment (전력 u-IT 융복합화 기기의 평가와 인증 연구)

  • Yi, Jeong-Hoon;Park, Dea-Woo;Kim, Eung-Sik;Kim, Hong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2433-2440
    • /
    • 2009
  • Whole system and network for supply of electric power and electricity safety are essential element. Electricity safety technology need rating for product and research about certification as product development that is done electric power u-IT cotton flannel mixed with development of u-IT, u-City base technology consists. Study on serve to develop electricity safety integration supervision system to apply product to u-City electric power appliance and cotton flannel mixed of u-IT appliance, Connection badness sensing instrument made device built-in electric power u-IT cotton flannel mixed in outlet that is used most in electric power appliance terminal. Using sensor on ZigBee, RFID performance estimation of communication module about function of product for remote safety check of electricity safety integration supervision system. A performance experiment and estimation in electric leakage, high voltage, Arc, fire detection diagnosis system and certification KS, electricity safety about product that get fitness finding.

Implementation of PC based Motor Fault Diagnosis System (PC 기반 전동기 고장 진단 시스템의 구현)

  • Doo, Seung-Ho;Park, Jin-Bae;Kwak, Ki-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2195-2196
    • /
    • 2006
  • This study is for implementation of PC based Motor fault diagnosis system. By using harmonics and current signals of the motor, this system diagnoses the motor condition by accumulated harmonic contribution rate. In this proposed system that was composed of 5 parts. A sensor, connection box, evaluation board, device server, and main computer are those. There were two types of sensor, one was harmonic sensor the other was current sensors. The signal was acquired by sensor, and transferred to evaluation board. Second one is connection box. Because the output type of sensor and input type of evaluation board is different, connection box was necessary. Third one was evaluation board. The signal from the sensor was converted to digital signal in evaluation board. And this signal was transferred to device server. Fourth one was device server. Device server transferred the data from evaluation board to main computer. And the last one was other parts controlled by main computer. In main computer, there were communication and diagnosis algorithms. The result was derived by main computer. In the result, there were 12 categories and 5 levels of motor conditions. The proposed system had some advantages comparing with stand alone type commercial motor fault diagnosis system. The first, by using remote access it was easier to get the conditions of motor. The second, there was no need to handle the sensors when users measured the motor signals. By this property, no one was necessary at motor location site. The third, this system was less restricted by times and places than commercial stand alone type diagnosis system. Therefore users can operate this system only using the main computer. Once the sensors are installed at the motor, users doesn't need to move to check up the condition of motors. Moreover, if there is ethernet hub, many motors can be not only diagnosed at once but also decreased its cost.

  • PDF

Implementation of PC based Motor Fault Diagnosis System (PC 기반 전동기 고장 진단 시스템의 구현)

  • Doo, Seung-Ho;Park, Jin-Bae;Kwak, Ki-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.563-564
    • /
    • 2006
  • This study is for implementation of PC based Motor fault diagnosis system. By using harmonics and current signals of the motor, this system diagnoses the motor condition by accumulated harmonic contribution rate. In this proposed system that was composed of 5 parts. A sensor, connection box, evaluation board, device server, and main computer are those. There were two types of sensor, one was harmonic sensor the other was current sensors. The signal was acquired by sensor, and transferred to evaluation board. Second one is connection box. Because the output type of sensor and input type of evaluation board is different, connection box was necessary. Third one was evaluation board. The signal from the sensor was converted to digital signal in evaluation board. And this signal was transferred to device server Fourth one was device solver. Device server transferred the data from evaluation board to main computer. And the last one was other parts controlled by main computer. In main computer, there were communication and diagnosis algorithms. The result was derived by main computer. In the result, there were 12 categories and 5 levels of motor conditions. The proposed system had some advantages comparing with stand alone type commercial motor fault diagnosis system. The first, by using remote access it was easier to get the conditions of motor. The second, there was no need to handle the sensors when users measured the motor signals. By this Property, no one was necessary at motor location site. The third, this system was less restricted by times and places than commercial stand alone type diagnosis system. Therefore users can operate this system only using the main computer. Once the sensors are installed at the motor, users doesn't need to move to check up the condition of motors. Moreover, if there is ethernet hub, many motors can be not only diagnosed at once but also decreased its cost.

  • PDF

Real Time On-line Quality Assurance System for HDR Brachytherapy (고선량률 근접 방사선 치료를 위한 실시간 온-라인 정도 관리(QA) 시스템 개발)

  • Lee Su Jin;Lee Re Na;Yi Byang Yang;Lim Sang Waak;Choi Jin Ho
    • Progress in Medical Physics
    • /
    • v.15 no.3
    • /
    • pp.156-160
    • /
    • 2004
  • An essential quality assurance (QA) procedure in high dose rate (HDR) remote after-loading brachytherapy is that of the verification of the Ir-192 HDR source positioning accuracy. A number of methods using mechanical rulers or autoradiograph and video cameras have been reported to check the positional error of the Ir-192 source. In this study, the feasibility of a CMOS (Complementary Metal Oxide Semiconductor) PC camera, with a fluorescent screen, was investigated. The agreement between the planned and measured dwell position was better than 1 mm and dwell times better than 0.4 sec. Our results indicate that the CMOS PC camera system could be used as a QA tool for the on-line determination of the source position and dwell time.

  • PDF