In-Situ Diagnosis of Vapor-Compressed Chiller Performance for Energy Saving

  • Shin Younggy;Kim Youngil;Moon Guee-Won;Choi Seok-Weon
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.8
    • /
    • pp.1670-1681
    • /
    • 2005
  • In-situ diagnosis of chiller performance is an essential step for energy saving business. The main purpose of the in-situ diagnosis is to predict the performance of a target chiller. Many models based on thermodynamics have been proposed for the purpose. However, they have to be modified from chiller to chiller and require profound knowledge of thermodynamics and heat transfer. This study focuses on developing an easy-to-use diagnostic technique that is based on adaptive neuro-fuzzy inference system (ANFIS). The effect of sample data distribution on training the ANFIS is investigated. It is found that the data sampling over 10 days during summer results in a reliable ANFIS whose performance prediction error is within measurement errors. The reliable ANFIS makes it possible to prepare an energy audit and suggest an energy saving plan based on the diagnosed chilled water supply system.

A Selection of Path Planning Algorithm to Maximize Survivability for Unmanned Aerial Vehicle (무인 항공기 생존성 극대화를 위한 이동 경로 계획 알고리즘 선정)

  • Kim, Ki-Tae;Jeon, Geon-Wook
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.103-113
    • /
    • 2011
  • This research is to select a path planning algorithm to maximize survivability for Unmanned Aerial Vehicle(UAV). An UAV is a powered pilotless aircraft, which is controlled remotely or autonomously. UAVs are currently employed in many military missions(surveillance, reconnaissance, communication relay, targeting, strike etc.) and a number of civilian applications(communication service, broadcast service, traffic control support, monitoring, measurement etc.). In this research, a mathematical programming model is suggested by using MRPP(Most Reliable Path Problem) and verified by using ILOG CPLEX. A path planning algorithm for UAV is selected by comparing of SPP(Shortest Path Problem) algorithms which transfer MRPP into SPP.

Issues in Building Large RSFQ Circuits (대형 RSFQ 회로의 구성)

  • Kang, J.H.
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.17-22
    • /
    • 2001
  • Practical implementation of the SFQ technology in most application requires more than single-chip-level circuit complexity. Multiple chips have to be integrated with a technology that is reliable at cryogenic temperatures and supports an inter-chip data transmission speed of tens of GHz. In this work, we have studied two basic issues in building large RSFQ circuits. The first is the reliable inter-chip SFQ pulse transfer technique using Multi-Chip-Module (MCM) technology. By noting that the energy contained in an SFQ pulse is less than an attojoule, it is not very surprising that the direct transmission of a single SFQ pulse through MCM solder bump connectors can be difficult and an innovative technique is needed. The second is the recycling of the bias currents. Since RSFQ circuits are dc current biased the large RSFQ circuits need serial biasing to reduce the total amount of current input to the circuit.

  • PDF

Dynamic Contention Window based Congestion Control and Fair Event Detection in Wireless Sensor Network

  • Mamun-Or-Rashid, Md.;Hong, Choong-Seon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2007.05a
    • /
    • pp.1288-1290
    • /
    • 2007
  • Congestion in WSN increases energy dissipation rates of sensor nodes as well as loss of packets and thereby hinders fair and reliable event detections. We find that one of the key reasons of congestion in WSN is allowing sensing nodes to transfer as many packets as possible. This is due to the use of CSMA/CA that gives opportunistic media access control. In this paper, we propose an energy efficient congestion avoidance protocol that includes source count based hierarchical and load adaptive medium access control. Our proposed mechanism ensures load adaptive media access to the nodes and thus achieves fairness in event detection. The results of simulation show our scheme exhibits more than 90% delivery ratio with retry limit 1, even under bursty traffic condition which is good enough for reliable event perception.

Measurement of Transfer Length for a Seven-Wire Strand with FBG Sensors (FBG 센서를 이용한 강연선 전달길이 측정)

  • Lee, Seong-Cheol;Choi, Song-Yi;Shin, Kyung-Joon;Kim, Jae-Min;Lee, Hwan-Woo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.6
    • /
    • pp.707-714
    • /
    • 2015
  • In this paper, an experimental program has been conducted to investigate transfer length in high strength concrete members pretensioned through a seven-wire strand with FBG sensors. To measure transfer length, five members were fabricated, which had a length of 3 m and a cross-section of $150{\times}150mm$. It was measured that the concrete compressive strength was 58MPa at pretensioning. Test results indicated that more precise and reliable measurement on the transfer length was attained with FBG sensors than conventional gauges attached on concrete surface. Through comparing the measured transfer length and predictions, applicability of several transfer length models in literature was investigated. This paper can be useful for relevant research field such as investigation on the bond mechanism of a seven-wire strand in concrete members.

Numerical heat transfer analysis methodology for multiple materials with different heat transfer coefficient in unstructured grid for development of heat transfer analysis program for 3 dimensional structure of building (건물의 3차원 구조체에 대한 전열해석 프로그램 개발 중 서로 다른 열전도율을 갖는 복합재질 3차원 구조의 비정렬 격자에 대한 전산해석 방법)

  • Lee, Juhee;Jang, Jinwoo;Lee, Hyeonkyun;Lee, Youngjun;Lee, Kyusung
    • KIEAE Journal
    • /
    • v.16 no.1
    • /
    • pp.81-87
    • /
    • 2016
  • Purpose: Heat transfers phenomena are described by the second order partial differential equation and its boundary conditions. In a three-dimensional structure of a building, the heat transfer phenomena generally include more than one material, and thus, become complicate. The analytic solutions are useful to understand heat transfer phenomena, but they can hardly be applied in engineering or design problems. Engineers and designers have generally been forced to use numerical methods providing reliable results. Finite volume methods with the unstructured grid system is only the suitable means of the analysis for the complex and arbitrary domains. Method: To obtain an numerical solution, a discretization method, which approximates the differential equations, and the interpolation methods for temperature and heat flux between two or more materials are required. The discretization methods are applied to small domains in space and time, and these numerical solutions form the descretized equations provide approximated solutions in both space and time. The accuracy of numerical solutions is dependent on the quality of discretizations and size of cells used. The higher accuracy, the higher numerical resources are required. The balance between the accuracy and difficulty of the numerical methods is critical for the success of the numerical analysis. A simple and easy interpolation methods among multiple materials are developed. The linear equations are solved with the BiCGSTAB being a effective matrix solver. Result: This study provides an overview of discretization methods, boundary interface, and matrix solver for the 3-dimensional numerical heat transfer including two materials.

Numerical analysis of heat transfer for architectural structure composed of multiple materials in ISO10211 (복합재질로 구성된 건축 구조체의 열전달 수치해석을 위한 ISI10211모델계산)

  • Lee, Juhee;Park, JiHo;Lee, YongJun
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.159-166
    • /
    • 2016
  • Purpose: The architectural structures in the engineering field include more than one material, and the heat transfer through these multiple materials becomes complicated. More or less, the analytic solutions obtained by the hand calculation can provide the limited information of heat transfer phenomena. However, the engineers have generally been forced to obtain reliable results than those of the hand calculation. The numerical calculation such as a finite volume methods with the unstructured grid system is only the suitable means of the analysis for the complex and arbitrary domains that consists of multiple materials. In this study, a new numerical code is developed to provide temperature distributions in the multiple material domains, and the results of this code are compared with the validation cases in ISO10211. Method: Finite volume methods with an unstructured grid is employed. In terms of numerical methods, the heat transfer conduction coefficient is not defined on the surface of the cell between different material cells. The heat transfer coefficient is properly defined to accurately mimic the heat transfer through the surface. The boundary conditions of heat flux considering radiation or heat convection are also developed. Result: The comparison between numerical results and ISO 10211 cases. We are confirmed that the numerical method provides the proper temperature distributions, and the heat transfer equation and its boundary conditions are developed properly.

Shielding Effect Analysis of Communication Cables Using EN50289 for Transfer Impedance Measurement of Coaxial Cable (EN50289 동축케이블 전달 임피던스 측정 방법을 이용한 통신 케이블의 차폐 효과 분석)

  • Lee, Keunbong;Zhang, Nan;Jeon, Jiwoon;Song, Seungje;Nah, Wansoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.11
    • /
    • pp.1156-1163
    • /
    • 2014
  • In this work by measuring transfer impedance of communication cables using EN50289 its Shielding effect is analyzed. transfer impedance measurement triaxial method using EN50289 is defined in CENELEC, it is unlike triaxial method prescribed in IEC Standard 96-1, can be measured regardless of diameter of coaxial cable and outer conductor. in this paper, transfer impedance measurement device of coaxial cable is designed and made according to EN50289 standard, The analysis determines the reliable working frequency range of coaxial cable and examined the impact of different shielding methods on coaxial cable. The transfer impedance measurements show considerable variations in results with various shielding methods. also the measurement procedure is verified through comparison of calculated and measured transfer impedance of RG-58 cable.

Evaporation Heat Transfer and Pressure Drop of $CO_2$ in a Small diameter Tube (세관내 이산화탄소의 증발 열전달 및 압력강화)

  • Jang, Seong-Il;Choi, Sun-Muk;Kim, Dae-Hui;Park, Ki-Won;Oh, Hoo-Kyu
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.189-194
    • /
    • 2005
  • The evaporation heat transfer and pressure drop of $CO_2$ in a small diameter tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section was made of a horizontal stainless steel tube with the inner diameter of 4.57 mm, and length of 4 m. The experiments were conducted at mass flux of 200 to 700 $kg/m^2s$, saturation temperature of $0^{\circ}C$ to $20^{\circ}C$, and heat flux of 10 to 20 $kW/m^2$ . The test results showed the evaporation heat transfer of $CO_2$ has great effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. The evaporation pressure drop of C02 are highly dependent on the mass flux. In comparison with test results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient and pressure drop of $CO_2$, therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient and friction pressure drop of $CO_2$ in a horizontal tube.

  • PDF

Evaporation Heat Transfer of Carbon Dioxide in a horizontal Round Tube (수평원관내 $CO_2$의 증발열전달)

  • Kyoung, Nam-Soo;Jang, Seung-Il;Choi, Sun-Muk;Son, Chang-Hyo;Oh, Hoo-Kyu
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.262-267
    • /
    • 2005
  • The evaporation heat transfer coefficient of $CO_2$ in a horizontal round tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section was made of a horizontal stainless steel tube with the inner diameter of 7.75 mm, and length of 5 m. The experiments were conducted at mass flux of 200 to 500 $kg/m^2s$, saturation temperature of $-5^{\circ}C$ to $5^{\circ}C$, and heat flux of 10 to 40 $kW/m^2$. The test results showed the evaporation heat transfer of $CO_2$ has great effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. In comparison with teat results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient of $CO_2$, therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

  • PDF