• Title/Summary/Keyword: Reliable transfer

Search Result 438, Processing Time 0.034 seconds

A Design of Hop-by-Hop based Reliable Congestion Control Protocol for WSNs (무선 센서 네트워크를 위한 Hop-by-Hop 기반의 신뢰성 있는 혼잡제어 기법 설계)

  • Heo Kwan;Kim Hyun-Tae;Ra In-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.6
    • /
    • pp.1055-1059
    • /
    • 2006
  • In Wireless Sensor Networks(WSNs), a sensor node broadcasts the acquisited sensing data to neighboring other nodes and it makes serious data duplication problem that increases network traffic loads and data loss. This problem is concerned with the conflict condition for supporting both the reliability of data transfer and avoidance of network congestion. To solve the problem, a reliable congestion control protocol is necessary that considers critical factors affecting on data transfer reliability such as reliable data transmission, wireless loss, and congestion loss for supporting effective congestion control in WSNs. In his paper, we proposes a reliable congestion protocol, called HRCCP, based on hop-hop sequence number, and DSbACK by minimizing useless data transfers as an energy-saved congestion control method.

Reliable Data Transfer using Path-Reliability and Implicit ACK on Wireless Sensor Network (무선 센서 네트워크에서 경로별 신뢰도와 묵시적 ACK를 사용한 신뢰성 보장 전송기법)

  • Lee, Ga-Won;Lee, Jun-Hyuk;Huh, Eui-Nam
    • Journal of Internet Computing and Services
    • /
    • v.11 no.2
    • /
    • pp.17-30
    • /
    • 2010
  • Many applications in Wireless Sensor Networks require collecting all data without loss from nodes. End-to-End data retransmission, which is used in the Internet for reliable transport, becomes very inefficient in Wireless Sensor Networks, since wireless communication, and constrained resources pose new challenges. We look at factors affecting reliability, and search for efficient combinations of the possible options. This paper proposes an efficient Overhearing based reliable transfer protocol in Wireless Sensor Networks by introducing Selective and implicit Acknowledgement. Finally, it is clarified that the proposed scheme is efficient for reliable data transfer in WSN.

The Reliable Multicast Transport Protocol over Wireless Convergence Networks using a Retransmission Agent (재전송 Agent를 이용한 유무선 융합망에서의 신뢰성 있는 멀티캐스트 전송 방식)

  • Youm, Sungkwan;Yu, Sunjin
    • Journal of the Korea Convergence Society
    • /
    • v.7 no.4
    • /
    • pp.25-32
    • /
    • 2016
  • When using reliable multicast protocol over air links, the multicast packets lost in the air link cause the initiation of retransmission request packets and the implosion of retransmission packets, which deteriorate multicast session performance. This paper proposes on the efficient reliable multicast mechanism in wireless networks utilizing the Agents. In this paper we show the design of a retransmission agent which improves the performance of reliable multicast sessions in wireless network. The main idea is to cache reliable multicast packets at the base station and perform local retransmissions across the wireless link. MATLAB has been used to simulate and to get performance results for signaling overhead and processing delay through the comparison of the proposed agent model to the Multicast File Transfer Protocol. It has been proven from the simulation results that the proxy module make pass trials shorter in Multicast File Transfer Protocol.

A Design of Hop-by-Hop based Reliable Congestion Control Protocol for WSNs (무선 센서 네트워크를 위한 Hop-by-Hop 기반의 신뢰성 있는 혼잡제어 기법 설계)

  • Heo Kwan;Kim Hyun-Tae;Yang Hae-Kwon;Ra In-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.442-445
    • /
    • 2006
  • In Wireless Sensor Networks(WSNs), a sensor node broadcasts an acquisited data to neighboring other nodes and it makes serious data duplication problem that increases network traffic loads and data loss. This problem is concerned with the conflict condition for supporting both the reliability of data transfer and avoidance of network congestion. To solve the problem, a reliable congestion control protocol is necessary that considers critical factors affecting on data transfer reliability such as reliable data transmission, wireless loss, and congestion loss for supporting effective congestion control in WSNs. In this paper, we proposes a reliable congestion protocol, ratted HRCCP, based on hop-hop sequence number, and DSbACK by minimizing useless data transfers as an energy-saved congestion control method.

  • PDF

Free Vibration Analysis of Timoshenko Arcs with Elastic Supports Using Transfer of Influence Coefficient (영향계수의 전달을 이용한 탄성 지지된 티모센코 호의 자유진동 해석)

  • Choi, Myung-Soo;Yeo, Dong-Jun
    • Journal of Power System Engineering
    • /
    • v.21 no.2
    • /
    • pp.70-76
    • /
    • 2017
  • When Timoshenko arcs considering the shear deformation and rotatory inertia have elastic supports, the authors analyze in-plane free vibration of them by the transfer influence coefficient method. This method finds the natural frequencies of them using the transfer of influence coefficient after obtaining the transfer matrix of arc element from numerical integration of the differential equations governing the vibration of arc. In this study, two computer programs were made by the transfer influence coefficient method and the transfer matrix method for analyzing free vibration of Timoshenko arcs. From numerical results of four computational models, we confirmed that the transfer influence coefficient method is a reliable method when analyzing the free vibration of Timoshenko arcs. In particular, the transfer influence coefficient method is a effective method when analyzing the free vibration of arcs with rigid supports.

A Modern Automatic Bus Transfer Scheme

  • Sidhu Tarlochan S.;Balamourougan Vinayagam;Thakur Manish;Kasztenny Bogdan
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.spc2
    • /
    • pp.376-385
    • /
    • 2005
  • The proliferation of technology has made global conduction of business increasingly dependent upon the availability of reliable power. As a result, alternate power systems are being installed and expanded to protect the broadening scope of critical electrical loads. Bus transfer restores designated critical loads to an alternate source when utility derived service becomes inadequate or goes out of service due to any contingency. This paper describes the practices, requirements and implementation of bus transfer of motor loads to an alternate source of power. A new high-speed automatic bus transfer scheme is proposed which includes the development of a new algorithm for determining the type of bus transfer required and the realization of the scheme by using modem protection devices and intra-substation communication facilities.

Measurement of Heat Transfer Coefficient in a Flooded Evaporator through Wilson Plot Method (Wilson Plot을 이용한 만액식 증발기의 열전달계수 측정)

  • 윤필현;강용태;정진희
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.8
    • /
    • pp.698-706
    • /
    • 2004
  • Heat transfer coefficients of enhanced tubes in a flooded evaporator are measured through Wilson Plot method. And the correlations are proposed to design a flooded evaporators. Overall heat transfer coefficients are composed of the heat transfer coefficients both inside and outside tubes. Usually the experiments have been conducted separately. But there have been many difficulties like setting up the equipments and measuring the wall temperature. Wilson Plot method makes it possible to measure the separated transfer coefficients at the same equipment through experimental skills. So the cost and time can be reduced. And the results are reliable enough to use for design. Heat transfer coefficients inside the tube were able to be correlated uniquely in spite of various outside conditions. Boiling heat transfer of R134a is more dependent on the saturation temperature and much higher than that of R123.

Flow Boiling Heat Transfer in a Horizontal Rectangular Microchannel (수평 사각 마이크로채널 내에서의 유동 비등 열전달)

  • Huh, Cheol;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.11 s.254
    • /
    • pp.1043-1050
    • /
    • 2006
  • An experimental investigation was performed to study flow boiling heat transfer of deionized water in a microchannel. Measurement and evaluation of boiling heat transfer coefficients were carried out using a single horizontal rectangular microchannel having a hydraulic diameter of $100{\mu}m$. Tests were performed for mass fluxes of 90, 169 and 267 $kg/m^2$s and heat fluxes of 200-700 $kW/m^2$. Test results showed that the measured boiling heat transfer coefficients had no dependence on mass flux and vapor quality. Most macro-channel correlations of boiling heat transfer coefficient did not provide reliable predictions.

Design Optimization of Pin-Fin Sharp to Enhance Heat Transfer

  • Li, Ping;Kim, Kwang-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.185-190
    • /
    • 2005
  • This work presents a numerical procedure to optimize the elliptic-shaped pin fin arrays to enhance turbulent heat transfer. The response surface method is used as an optimization technique with Reynolds-averaged Navier Stokes analysis of flow and heat transfer. Shear stress transport (SST) turbulence model is used as a turbulence closure. Computational results for average heat transfer rate show a reasonable agreement with the experimental data. Four variables including major axis length, minor axis length, pitch and the pin fin length nondimensionalized by duct height are chosen as design variables. The objective function is defined as a linear combination of heat transfer and friction-loss related terms with weighting factor. D-optimal design is used to reduce the data points, and, with only 28 points, reliable response surface is obtained. Optimum shapes of the pin-fin arrays have been obtained in the range from 0.0 to 0.1 of weighting factor.

  • PDF

Evaluation of Condensation Heat Transfer Correlations for Microfin Tubes

  • Han, Dong-Hyouck;Lee, Kyu-Jung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.4
    • /
    • pp.163-168
    • /
    • 2007
  • The feature of six existing condensation heat transfer correlations for microfin tubes were evaluated with the consideration of vapor quality, mass flux, geometries, and various refrigerants. The Kosky and Staub [15] and the Jaster and Kosky [16] correlations for smooth tube were used for the evaluation of the heat transfer enhancement factor (EF). For the prediction of zeotropic mixtures, most correlations show discrepancy with previous measurements. The Yu and Koyama [4] and the Shikazono et al. [8] correlations do not consider spiral angle effect. The Han and Lee [10] correlation shows fin height growth deteriorates heat transfer. Experimental verification to develop reliable condensation heat transfer correlation for microfin tubes is still needed with the consideration of geometrical effects and working conditions.