• 제목/요약/키워드: Reliability of the Test Results

검색결과 3,700건 처리시간 0.035초

아동 색 선로 검사의 표준화 연구 (A Standardization Study of Children's Color Trails Test(CCTT))

  • 구훈정;신민섭
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • 제19권1호
    • /
    • pp.28-37
    • /
    • 2008
  • Objectives : This study was conducted in order to examine the reliability and validity of the Children's Color Trails Test (CCTT). The objective of the study was also to provide the Korean normative data for the CCTT. Methods : Normative samples consisted of 766 children and adolescents living in Seoul and aged from 5 to 15 years. Eighty children who were diagnosed with ADHD, based on the DSM-IV criterion, were recruited from Seoul National University Children's Hospital. Among them, 46 ADHD children were receiving medication, while 34 children were drug-free. Results : The scores of the CCTT were significantly correlated with those of the Stroop test. Three factors were extracted through factor analysis-visual tracking and cognitive flexibility, distractibility and susceptibility to interference, and simple attention and impulsivity. The completion time of the CCTT for all children tended to decrease as age increased. There were significant differences in the CCTT scores between the ADHD group receiving medication, the ADHD-drug free group and the normal groups. The CCTT also showed sound test-retest reliability. These results confirmed the reliability and validity of the CCTT. Finally, we provided the Korean normative data for the CCTT. Conclusion : These results suggest that the CCTT is a reliable and valid test, which can be used to assess frontal function related to child psychiatric disorders in Korean children.

  • PDF

The test-retest reliability of gait kinematic data measured using a portable gait analysis system in healthy adults

  • An, Jung-Ae;Byun, Kyung-Seok;Lee, Byounghee
    • 대한물리치료과학회지
    • /
    • 제27권3호
    • /
    • pp.25-34
    • /
    • 2020
  • Background: Gait analysis is an important measurement for health professionals to assess gait patterns related to functional limitations due to neurological or orthopedic conditions. The purpose of this study was to investigate the reliability of the newly developed portable gait analysis system (PGAS). Design: Cross-sectional design. Test-retest study. Methods: The PGAS study was based on a wearable sensor, and measurement of gait kinematic parameters, such as gait velocity, cadence, step length and stride length, and joint angle (hip, knee, and ankle) in stance and swing phases. The results were compared with a motion capture system (MCS). Twenty healthy individuals were applied to the MCS and PGAS simultaneously during gait performance. Results: The test-retest reliability of the PGAS showed good repeatability in gait parameters with mean intra-class correlation coefficients (ICCs) ranging from 0.840 to 0.992, and joint angles in stance and swing phase from 0.907 to 0.988. The acceptable test-retest ICC was observed for the gait parameters (0.809 to 0.961), and joint angles (0.800 to 0.977). Conclusion: The results of this study indicated that the developed PGAS showed good grades of repeatability for gait kinematic data along with acceptable ICCs compared with the results from the MCS. The gait kinematic parameters in healthy subjects can be used as standard values for adopting this PGAS.

기능 안전 관점에서의 의료기기 소프트웨어 신뢰성 평가 방법에 관한 연구 (Study on Reliability Assessment for the Medical Device Software from the Viewpoint of Functional Safety)

  • 김성민;고병각;도경훈;김혜진;함중걸
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제16권3호
    • /
    • pp.216-223
    • /
    • 2016
  • Purpose: This paper suggests the procedure to enhance the reliability of the software of the medical device that is to cure, treat, diagnose, and prevent a disease or an abnormal health conditions. Methods: After test requirements are classified by the software requirements specification for safety and backgrounds, reliability assessment methods are suggested. Results: Verification and validation for function and safety can be performed whether the medical device software are implemented as intended. Conclusion: Procedure on the static analysis, unit test, integration test, and system test are provided for the medical device software.

승용 자동차 조종장치 스테레오타입 조사를 위한 설문조사법의 신뢰성 (Test-Retest Reliability of Paper-Pencil Test for Investigating Stereotypes of Controls of Passenger Cars)

  • 기도형
    • 대한안전경영과학회지
    • /
    • 제17권2호
    • /
    • pp.201-206
    • /
    • 2015
  • This study aims to investigate test-retest reliability or reproducibility of the paper-pencil test for investigating stereotypes of seven principal controls of passenger cars. The controls include wiper, head light, high beam, door window, ignition key, door key and door lock. Sixty two college-aged students participated in the paper-pencil tests and the tests were conducted twice with an in-between period of 4 weeks. The results showed that the stereotypes of motion-directions for the seven controls by the two paper-pencil tests were the same, and that the percentage agreements between two tests by subjects were ranged from 60.0% to 80.6%. There was a weak linear relationship between averaged rates of responses for the stereotypes of motion-directions for the seven controls and percentage agreements by subjects. Based on these results, it is concluded that the paper-pencil test collects reliable or reproducible data on the stereotypes of motion-directions for passenger cars' controls within four weeks.

통계적 가설검정을 이용한 중심형 버터플라이 밸브의 신뢰성 평가 (Reliability Evaluation of Concentric Butterfly Valve Using Statistical Hypothesis Test)

  • 장무성;최종식;최병오;김도식
    • 대한기계학회논문집A
    • /
    • 제39권12호
    • /
    • pp.1305-1311
    • /
    • 2015
  • 버터플라이 밸브는 일반적으로 유량을 조절하기 위해 사되는 유량 제어 장치의 일종이다. 본 연구에서는 중심형 버터플라이 밸브의 개선 전후 제품에 대한 신뢰성 시험 데이터의 통계적 분석을 통하여 버터플라이 밸브에 대한 와이블 분포의 형상모수, 특성수명 및 $B_{10}$ 수명을 추정한다. 또한 통계적 가설검정을 이하여 개선 전후 제품의 형상모수와 척도모수에 대한 차이를 검토한다. 가설검정 결과로부터 개선 전후 제품의 형상모수는 유사하며, 척도모수는 증가함을 알 수 있었다. 이러한 분석결과는 향후 신뢰성 인증시험이나 제품에 대한 보증수명 설정에 유한 정보로 활용될 수 있다.

Reliability and Validity of Korean-Version of Information Needs in Cardiac Rehabilitation Scale

  • Choi, Sang Young Heon;Kim, Joong Hwi
    • The Journal of Korean Physical Therapy
    • /
    • 제34권5호
    • /
    • pp.234-241
    • /
    • 2022
  • Purpose: The Cardiac Rehabilitation scale (INCR scale) is a verified measure worldwide. The scale measures the extent to which cardiac rehabilitation meets the various needs of the participating patients and determines how education related to heart disease and rehabilitation satisfies their preferences. The current study applied the INCR scale to verify and develop it for use in Korea by conforming to Korean culture and language. Methods: The Korean version of the INCR scale was created after a six-step process in accordance with the international questionnaire translation law. The Korean version of the INCR scale was assessed in 45 cardiac rehabilitation patients (29 males, 16 females). Internal consistency was verified using Cronbach's alpha. Test-re-test reliability and interrater reliability were verified using the intraclass correlation coefficient (ICC). Content validity was selected to verify the validity. Results: The content validity index of the Korean version of the INCR scale was high, with an average of 0.93. Cronbach's Alpha for Internal consistency also revealed high reliability of 0.89 in all 10 categories. The interclass correlation coefficient of the test-re-test and interrater reliability scores were 0.95 and 0.81, respectively. Conclusion: Our results indicate that the Korean version of the INCR scale would be instrumental in the clinical setting to determine the knowledge, educational needs, and preferences of patients participating in cardiovascular disease and cardiac rehabilitation.

유압 호스의 진동 내구성 평가를 위한 지그의 구조적 안정성에 관한 연구 (A Study on the Structural Stability of a Jig for Evaluating the Vibration Durability of a Hydraulic Hose)

  • 김재실;전민승
    • 한국기계가공학회지
    • /
    • 제20권1호
    • /
    • pp.125-131
    • /
    • 2021
  • For the vibration reliability tests, the jigs for mounting the test specimen on a vibration reliability tester are required. The dynamic stabilities of the jigs should be verified before the tests for obtaining the accurate reliability of the test specimen. This paper proposes an analytical technology for ensuring the dynamic structural stability for the test setup including the jig. The technology includes the mode analyses for checking resonance, the harmonic analyses for evaluating the dynamic structural stability of test setup including the jig, and the fatigue analyses for obtaining the durable reliability time with calculating the life cycles at the area of weakness. The cause investigation of the damaged jig during vibration reliability test of a rubber hose and the design of new revised jig are performed by using the technology. The vibration reliability test for the rubber hose with the new revised jig by analysis results is successfully conducted without any problem. Therefore the jig's design technology proposed in this paper may be useful for other items as well.

GIS용 절연스페이서 신뢰성령가기반 구축 (Construction of Reliability Assessment Infrastructure for Spacers in GIS)

  • 이정기;김민규;김익수;정주영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.180-181
    • /
    • 2006
  • In this paper, there have been brief review about the important consideration in laboratory planning and construction of the reliability assessment infrastructure including 400 kV, 120 kVA AC test system, which enable to evaluate the HV long-term overcharged withstand performance for spacers using in Gas Insulated Switchgears up to transmission class, Also it is described simply about its trial running of the whole test system and its assessment example. To inform the founded national code, RS C 0084, and the procedure for getting a reliability assessment certificate issued by the government, brief description of the code and summation of test results have been conducted.

  • PDF

Test-Retest Reliability of Paper-Pencil Test for Investigating Burner-Control Linkages of Four-Stove Gas Range

  • Kee, Dohyung
    • 대한인간공학회지
    • /
    • 제32권3호
    • /
    • pp.267-271
    • /
    • 2013
  • Objective: The purpose of this study is to examine the test-retest reliability of paper-pencil test for investigating population stereotype of burner-control linkages of four-stove gas ranges. Background: Much of the research on gas-range stereotype strength has been performed using the paper-pencil test. While the use of the paper-pencil tests has the advantage of collecting data in a large group of subjects against reasonable costs, concerns regarding the reliability of the paper-pencil test has also been stated. Method: Three paper-pencil tests classified by intervals of test-retest were performed, in which eight types of burner-control arrangements were investigated. Sixty eight subjects were test-retested within two weeks, 85 subjects were test-retested within four weeks and 58 subjects were test-retested three times in series with interval of two and four weeks. Results: Chi-square test showed that three intervals of test-retest including two, four and two & four weeks have not statistically significant effect on subjects' responses irrespective of eight types of burner-control linkages dealt with in this study(p>0.10). Concordance rates of subjects' responses ranged between 73.5% and 100.0% for two-week test-retest, between 67.1% and 97.6% for four-week test-retest, and between 65.5% and 100.0% for two- and four-week serial test-retest. The concordance rates were linearly correlated with proportion of subjects' responses for stereotypes of burnercontrol linkages. Conclusion: It is concluded that the paper-pencil tests for investigating gas range relevant stereotypes could reproduce reliable results compared to baseline test within interval of four weeks. Application: The results of this study would be useful as an ergonomic guideline when designing the paper-pencil tests for stereotype relevant studies.

Comparisons of Test-Retest Reliability of Strength Measurement of Gluteus Medius Strength between Break and Make Test in Subjects with Pelvic Drop

  • Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • 제31권3호
    • /
    • pp.147-150
    • /
    • 2019
  • Purpose: The purpose of this study was to compare the reliability of unilateral hip abductor strength assessment in side-lying with break and make test in subjects with pelvic drop. Hip abduction muscles are very important in the hip joint structures. Therefore, it is essential to evaluate their strength in a reliable way. Methods: Twenty-five subjects participated in this study. Unilateral isometric hip abductor muscle strength was measured in side-lying, with use of a specialized tensiometer using smart KEMA system for make test, of a hand held dynamometer for break test. Coefficients of variation, and intra class correlation coefficients were calculated to determine test-retest reliability of hip abductor strength. Results: In make test, maximal hip abductor strength in the side-lying position was significantly higher compared with break test (p<0.05). Additionally, Test-retest reliability of hip abductor strength measurements in terms of coefficients of variation (3.7% for make test, 16.1% for break test) was better in the side-lying position with make test. All intraclass correlation coefficients with break test were lower than make test (0.90 for make test, 0.73 for break test). Conclusion: The side-lying body position with make test offers more reliable assessment of unilateral hip abductor strength than the same position with break test. Make test in side-lying can be recommended for reliable measurement of hip abductor strength in subjects with pelvic drop.