• 제목/요약/키워드: Reliability of the Test Results

검색결과 3,724건 처리시간 0.041초

실외조명 LED용 SMPS의 가속수명시험법 제안 (Suggested Accelerated Life Test Method of SMPS for Outdoor Lighting LED)

  • 임성용;형재필;임홍우;오근태
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제18권1호
    • /
    • pp.8-19
    • /
    • 2018
  • Purpose: This study has developed the accelerated lifetime test method for smps for outdoor lighting LED through two factors of temperature and humidity. Methods: Acceleration condition was confirmed for each stress and model, and acceleration life test model was estimated according to acceleration condition. Results: As a result of confirming the accelerated life test model, in the case of humidity, acceleration was established only in the foreign products. Therefore, it is confirmed that the acceleration condition is insufficient. However, the estimated parameters for temperature are relatively constant. It is therefore suitable for power supply acceleration tests for outdoor lighting LEDs. Conclusion: The SMPS acceleration test for outdoor lighting LED can improve the availability of the product by developing an accelerated life test method that guarantees the reliability of the product.

노인의 삶의 의미 측정 도구 개발 (Development of the Meaning in Life Scale for Older Adults)

  • 이시은;홍손귀령
    • 대한간호학회지
    • /
    • 제47권1호
    • /
    • pp.86-97
    • /
    • 2017
  • Purpose: The purpose of this study was to develop and test the psychometric properties of the newly developed instrument, Meaning in Life, for elderly Korean people. Methods: Ten older adults participated in the qualitative research used to develop the initial items. Participants for the psychometric testing were 371 community-dwelling older adults. Validity and reliability analyses included content, construct, and criterion-related validities, internal consistency, and test-retest reliability. Results: The Meaning in Life Scale consisted of 12 items with three distinct factors; value of life, source of life, and will to live, which explained 86.7% of the total variance. A three-factor structure was validated by confirmatory factor analysis. Criterion-related validity was supported by comparison with the Purpose in Life Test (r=.74). Reliabilities were secured with test-retest reliability of Intra-class Correlation Coefficient (ICC) .85 and the Cronbach's alpha coefficient .90. Conclusion: The results of this study indicate that this instrument is useful to measure meaning in life in Korean elders.

Wiener Process 및 D-Optimality 조건 하에서 계단형 가속열화시험 설계 (Design of Step-Stress Accelerated Degradation Test based on the Wiener Process and D-Optimality Condition)

  • 김헌길;박재훈;성시일
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제17권2호
    • /
    • pp.129-135
    • /
    • 2017
  • Purpose: This article provides step-stress accelerated degradation test (ADT) plans based on the Wiener process. Method: Step-stress levels and the stress change times are determined based on the D-optimality criteria to develop test plans. Further, a simple grid search method is provided for obtaining the optimal test plan. Results: Based on the solution procedure, ADT plans which include the stress levels and change times are developed for conducting the reliability test. Conclusion: Optimal step-stress ADT plans are provided for the case where the number of measurements is small.

무릎관절 전치환술 환자에 대한 WOMAC 지수의 신뢰도와 타당성에 관한 연구 (Study of the Reliability and Validity of the WOMAC Index in Patients with Total Knee Replacement )

  • 조훈;김경;임상철
    • 대한물리의학회지
    • /
    • 제18권2호
    • /
    • pp.93-101
    • /
    • 2023
  • PURPOSE: The Western Ontario and McMaster Universities Arthritis (WOMAC) index has been used to measure the outcome of total knee replacement (TKR), but studies on its reliability and validity are limited. The present study examined the reliability and validity of this index for patients with knee osteoarthritis who underwent TKR. METHODS: Seventy-one inpatients and outpatients who underwent bilateral TKR for knee osteoarthritis were included in this study. The pain assessment scale and WOMAC index were used to evaluate the participants every two weeks to examine the test-retest reliability, internal consistency, and construct validity. RESULTS: The test-retest reliability scores for pain, stiffness, and physical function were .75-.92, .85-.90, and .75-.95, respectively. The corresponding intraclass correlation coefficients were .75-.88, .76-.88, and .71-.95, respectively. The internal consistency score in the first and second examinations was .92. Furthermore, the construct validity scores for pain, stiffness, and physical function were .83, .41, and .58, respectively. CONCLUSION: The application of the WOMAC index in patients who underwent TKR showed high test-retest reliability and internal consistency with the use of the WOMAC index and good validity with the use of the pain assessment scale.

고속 터보기계용 공기 포일 저널 베어링의 신뢰성에 관한 연구 (A Study on the Reliability of an Air Foil Journal Bearing for High Speed Turbomachinery)

  • 이용복;김태호;김창호;이남수
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.199-206
    • /
    • 2002
  • This paper describes a reliability characteristics of an air foil journal bearing for high speed turbomachinery at room temperature. To verify the reliability of air foil journal bearing, lift-off characteristics, load carrying capacity, and 10,000 cycle start-stop test were performed with motor driven test rig. Lift-off test shows the relationship between the rotating speed of the shaft and the frictional torque with bearing surface. About load carrying capacity, the tested air foil journal bearing produced a load capacity of 500N at an operating speed of 15,000rpm, which is compared with results of numerical analysis and empirical coefficients. Finally, The trends in change of start torque, stop torque, and bearing temperature were shown during 10,000 cycle start-stop test of an air foil journal bearing. from the results of this work, an air foil bearing will be done well, as a supported bearing for high speed turbo-compressor.

  • PDF

경계정충 변증도구 신뢰도 평가 및 개선방안 연구 (A Study to Assess the Reliability and Improvement of the Instrument of Pattern Identification for Jing Ji and Zheng Chong)

  • 최우창;이헌수;서복남;강위창;정인철
    • 동의신경정신과학회지
    • /
    • 제25권4호
    • /
    • pp.371-382
    • /
    • 2014
  • Objectives: The purpose of this study is to examine the test-retest reliability and to suggest methods to enhance reliability. Methods: Participants consisted of 145 patients with generalized anxiety disorder who were diagnosed by the Structured Clinical Interview for DSM-IV Axis I Disorders. Participants were tested twice within one week. Results: The test-retest reliability of the Instrument of Pattern Identification for Jing Ji and Zheng Chong was examined in 145 patients and it was calculated as 0.3919. Internal Reliability of each part was calculated as 0.320~0.502. Reliability and concordance rate of symptoms are presented in the table. Frequency of symptoms and correlation between weight and frequency are also presented in the table. Conclusions: Based on these results, we have modified the Instrument of Pattern Identification for Jing Ji and Zheng Chong.

Reliability and Validity of Measurement Using Smartphone-Based Goniometer of Tibial External Rotation Angle in Standing Knee Flexion

  • Jeon, In-Cheol;Kwon, Oh-Yun;Weon, Jong-Hyuck;Ha, Sung-Min;Kim, Si-Hyun
    • 한국전문물리치료학회지
    • /
    • 제20권2호
    • /
    • pp.60-68
    • /
    • 2013
  • The purpose of this study was to assess the intra-rater test-retest reliability of tibial external rotation angle measurement using a smartphone-based photographic goniometer, DrGoniometer (DrG) compared to a three-dimensional motion analysis system (Vicon). The current study showed an interchangeable method using DrG to measure the tibial external rotation angle in standing knee flexion at $90^{\circ}$. Twelve healthy subjects participated in this study. A rest session was conducted 30 minutes later for within-day reliability and five days later for between-day intra-rater test-retest reliability. To assess the validity of the measurement using DrG, we used a three dimensional motion analysis system as a gold standard to measure the angle of tibial external rotation. Intra-class correlation coefficient (ICC) and the standard error of measurement (SEM) values were used to determine the within- and between- day intra-rater test-retest reliability of using DrG and a three dimensional motion analysis system. To assess validity, Pearson correlation coefficients were used for two measurement techniques. The measurement for tibial external rotation had high intra-rater test-retest reliability of within-day (ICC=.88) and between-day (ICC=.83) reliability using DrG and of within-day (ICC=.93) and between-day (ICC=.77) reliability using a three-dimentional motion analysis system. Tibial external rotation angle measurement using DrG was highly correlated with those of the three-dimensional motion analysis system (r=.86). These results represented that the tibial external rotation angle measurement using DrG showed acceptable reliability and validity compared with the use of three-dimensional motion analysis system.

A Study on the Validity and Test-Retest Reliability of the Measurement of the Craniovertebral Angle of the Smart Phone Application 'Angles Video Goniometer'

  • Hyeon-Seong Joo;Byeong-Soo Kim;Myung-Mo Lee
    • Physical Therapy Rehabilitation Science
    • /
    • 제11권4호
    • /
    • pp.454-463
    • /
    • 2022
  • Objective: The purpose of this study was to compare concurrent validity and test-retest reliability based on Craniovertebral angle of 'Angles video goniometer', a smart phone application for convenient range of motion measurement, and 'Image J', an analysis software with high reliability and validity. This was conducted to find out whether 'Angle video goniometer' can be used clinically. Design: Cross-sectional study Methods: Fifty subjects were imaged laterally, and the angle of the head and spine was measured using Image J and the Angles video goniometer, respectively, in a resting posture and a chin in posture. The level of concurrent validity between the two measurement methods and the level of inter-rater reliability and intra-rater reliability were analyzed. Results: For forty participants, the concurrent validity between Image J and Angles video goniometer showed very high validity with ICC of 0.997(0.995~0.999) and 0.994(0.994~0.998), CVME% 0.71~0.72%, SEM% 0.31~0.34, MDC% 0.86~0.94. The test-retest intra-rater reliability showed very high reliability ICC 0.994(0.991~0.996), CVME% 0.71%, SEM% 0.31~0.43, MDC% 0.86~1.19%. The test-retest inter-rater showed very high reliability ICC 0.995(0.992~0.997), CVME% 0.71%, SEM% 0.43~0.59%, MDC% 1.20~1.62% Conclusions: Angles video goniometer', a smartphone application, is a device with very high reliability and validity for craniovertebral angle measurement in healthy adults, and it is a device that can be easily used in clinical practice.

고압 커패시터의 고장분석과 신뢰성 평가 (Reliability Evaluation and failure Analysis for High Voltage Ceramic Capacitor)

  • 김진우;송옥병;신승우;이희진;신승훈;유동수
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2001년도 정기학술대회
    • /
    • pp.337-337
    • /
    • 2001
  • High voltage ceramic capacitors are widely applied in power electronic circuits, such as filters, snubbers, and resonant circuits, due to their excellent features of high voltage endurance and low aging. This paper presents a result of failure analysis and reliability evaluation for high voltage ceramic capacitors. The failure nodes and failure mechanisms were identified in order to understand the failure physics in a component. The causes of failure mechanisms for zero resistance phenomena under withstanding voltage test in high voltage ceramic capacitors molded by epoxy resin were studied by establishing an effective closed-loop failure analysis. Also, the condition for dielectric breakdown was investigated. Particular emphasis was placed on breakdown phenomena at the ceramic-epoxy interface. The validity of the results in this study was confirmed by the results of accelerated testing. Thermal shock test as well as pressure cooker test for high voltage ceramic capacitor mounted on a magnetron were implemented. Delamination between ceramic and epoxy, which, might cause electrical short in underlying circuitry, can occur during curing or thermal cycling. The results can be conveniently used to quickly identify defective lots, determine mean time to failure (MTTF) of each lot at the level of Inspection, and detect major changes in the vendors processes.

  • PDF

Reliability and validity of new evaluation methods using static surface electromyography in persons with neck pain

  • Kim, Go-Eun;Yun, Dong-Uk;An, Yu-Ju;Park, Dae-Sung;Ham, Joo-Hyun
    • Physical Therapy Rehabilitation Science
    • /
    • 제8권1호
    • /
    • pp.1-7
    • /
    • 2019
  • Objective: The aim of this study was to evaluate the validity and reliability of using static surface electromyography (sEMG) on persons with neck pain and in healthy adults. Design: Cross-sectional study. Methods: Twenty-two female participants with neck pain and thirty healthy adults in the age group of 20-65 years were recruited in this study. To evaluate the validity and reliability of sEMG in subjects with neck pain, the subjects'characteristics were recorded and the Visual Analog Scale (VAS) and Neck Disability Index (NDI) were examined in addition to sEMG and algometer tests being carried out on the subjects. The site for using the sEMG and algometer was the upper trapezius. sEMG test-retest reliability was measured by intraclass correlation coefficients (ICCs). Independent t-tests were used to analyze the differences in the dependent variables between subjects with neck pain and healthy adults. The Pearson correlation coefficient was used to examine the linear relationship between measured variables. Results: sEMG and algometer tests were reliable according to the test-retest reliability results in subjects with neck pain and healthy adults (ICC=0.815-0.979). The results of this study showed that there were significant differences in respect to age, VAS, sEMG and algometer tests between persons with neck pain and healthy adults (p<0.05). The VAS and NDI were statistically correlated with sEMG and algometer results (p<0.05). Conclusions: In this study, we investigated the clinical usefulness of the static sEMG test in evaluating the pain scale of persons with neck pain with high reliability and validity.