• Title/Summary/Keyword: Reliability Measurement Factors

Search Result 435, Processing Time 0.029 seconds

An interior noise analysis of KTX vehicles on various operating conditions (한국형 고속철도 차량의 운행조건에 따른 차내 소음 분석)

  • Choi Sunghoon;Kim Jae-Chul;Lee Chan-Woo;Moon Kyung-Ho
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.138-142
    • /
    • 2003
  • The conditions for measurement of the interior noise should meet the international standards. However, due to the limitations in test conditions the possible errors in measurement equipment, reliability of the measurement results has been questioned. Hence, the test procedure for the interior noise measurement of KTX vehicles are reviewed and investigated with the reference of international standards. Furthermore, the acceptable tolerance is inspected through the analysis of the factors that influence the interior noise of the KTX vehicle.

  • PDF

An RSS-Based Localization Scheme Using Direction Calibration and Reliability Factor Information for Wireless Sensor Networks

  • Tran-Xuan, Cong;Koo, In-Soo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.4 no.1
    • /
    • pp.45-61
    • /
    • 2010
  • In the communication channel, the received signal is affected by many factors that can cause errors. These effects mean that received signal strength (RSS) based methods incur more errors in measuring distance and consequently result in low precision in the location detection process. As one of the approaches to overcome these problems, we propose using direction calibration to improve the performance of the RSS-based method for distance measurement, and sequentially a weighted least squares (WLS) method using reliability factors in conjunction with a conventional RSS weighting matrix is proposed to solve an over-determined localization process. The proposed scheme focuses on the features of the RSS method to improve the performance, and these effects are proved by the simulation results.

Validity and Reliability for the Use of Program Outcome Indirect Measurement Tool in Korean Nursing Baccalaureate Education (간호교육 프로그램 학습성과 간접측정도구의 활용을 위한 신뢰도 및 타당도 검증)

  • Song, Mi Ok;Kim, Heeyoung
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.8
    • /
    • pp.608-618
    • /
    • 2021
  • The aim of this study was to verify the feasibility and reliability of the program outcome indirect measurement tool developed for nursing college students in Korean. 396 nursing students from 5 nursing colleges participated in this study, data were collected from November 22 to December 10, 2019. Data analysis was conducted using the IBM Statistics SPSS 21.0 and AMOS 21.0 programs to analyze item analysis, exploratory and confirmatory factor analysis. As a result of the item analysis, all 79 items were selected for factor analysis. In the exploratory factor analysis, five items that were loaded with other factors were deleted. The final factor loading range was from .37 to .86, and the cumulative explanatory variance for 12 factors was 71.71%. No items were deleted as a result of the confirmatory factor analysis, and the final scale was consisted of 74 items. The average score for scale was 3.78 and Cronbach' α was .98. The feasibility and reliability of the program outcome indirect measurement tool have been verified through this study. Therefore it can be used as a more standardized indirect measurement tool for nursing college students.

Optimal Design of Flow Measurement System Using Turbine Flowmeter (터빈유량계를 이용한 유량 측정 시스템의 최적 설계)

  • Kim, Hong-Tark;Kim, Boo-Il
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.77-84
    • /
    • 2018
  • The turbine flowmeter is selected for high precision and reproducibility at the time of flow rate measurement but causes various uncertainty factors of measurement in the difference between the standard environmental condition at calibration and the environmental condition at the site. Also, a reliable interpolation method is required for use in sections other than calibrated measurement values. Therefore, in this paper, in order to improve the reliability of the flow rate measurement, we designed and manufactured a device that accurately measures the output signal of the turbine flowmeter, interpolates the value of the calibrated result value, and corrects the temperature change in real time We confirmed the reliability of the measurement at the site to carry out the performance verification.

Measurement Uncertainty calculation for improving test reliability of Agricultural tractor ROPS Test (농업용트랙터 ROPS 시험의 신뢰성 향상을 위한 측정불확도 추정)

  • Ryu Gap Lim;Young Sun Kang;Taek Jin Kim
    • Journal of Drive and Control
    • /
    • v.20 no.1
    • /
    • pp.34-40
    • /
    • 2023
  • The agricultural tractor ROPS test method according to OECD code 4 is a test to assess whether the driver's safety area can be secured when a tractor overturns, and reliability should be ensured. In this study, a model formula and procedure for calculating measurement uncertainty expressing reliability in the field of agricultural machinery testing were established according to the ISO/IEC Guide 98-3:2008. The characteristics of the ROPS test device were assessed and repeated tests were performed, and the were used as factors to calculate the measurement uncertainty. As a result of repeated tests, the accuracy was higher than 1.9 % in all load directions; thus, they were, applied to calculate the type A standard uncertainty. The final expanded uncertainty was calculated within the range of less than ± 7.76 kN of force and ± 6.96 mm of deformation in all load directions.

Application of the Balanced Scorecard for the Performance Measurement in Health-care Organization (의료기관에서의 Balanced Scorecard를 이용한 성과측정)

  • Chun, Je-Ran
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.4
    • /
    • pp.254-264
    • /
    • 2009
  • The purpose of this study was to develop a performance measurement factor of Balanced Scorecard(BSC) for health-care organization. We did also the research to evaluate the validity and reliability of these indicators. Fifty six health-care organizations are participated in a survey questionnaires. This questionnaires consists of 53-questions, which are the performance evaluation indicators designed by researcher, which are based on the Norton and Kaplan's BSC-Framework. Exploratory and confirmatory factor analysis was carried out and Analytical Hierarchy Process (AHP) was applied to analyze the weight and significances of each factor. Factor analysis of the BSC resulted in 11 major measurement factors (Eigenvalue >1.0). The AHP analysis showed the list of the hospital BSC measurement factors and its KPI(Key Performance Indicator) weighted by its significance priorities. The recommendable degree of reliability and validity of these BSC factors suggests that these factors are adequate for performance measurements of the health-care organizations in Korea.

A Study on the Determinants of Medical Institution's Customer Satisfaction and Loyalty: Focused on the Effects of Service Quality Factors

  • Seungnyun Choi
    • Physical Therapy Rehabilitation Science
    • /
    • v.12 no.3
    • /
    • pp.346-354
    • /
    • 2023
  • Objective: The objective of this study is to provide medical institutions with theoretical basis by analyzing the effect of service quality-related factors. It will be helpful for hospitals to enhance service quality which will be of use to attain customer satisfaction and ultimately competitive advantage. Design: An empirical study. Methods: To verify the model, I conducted a questionnaire survey analysis. Items for measurement have been extracted from several related studies on medical industry. The survey target has been set by convenience sampling method and consists of citizens reside in Seoul and Gyeonggi-do Province, and total number of 161 samples have been analyzed. To verify validity and reliability, I conducted factor analysis and reliability analysis, and for hypotheses verification, multiple regression analyses have been performed. Results: This study aims to investigate the relation between service quality factors and customer satisfaction, and also those factors and customer loyalty. Service quality factors consist of Tangibles(X1), Reliability(X2), Assurance(X3), Responsiveness(X4), and Empathy(X5). According to the results of regression analyses, X1, X2, X3, and X5 have been proved to have positive relations with customer satisfaction and loyalty, whereas hypothesis related X4 has not been supported. Finally, customer satisfaction has been founded to affects positively to customer loyalty. Conclusions: Service quality factors are significantly related to customer satisfaction and loyalty. So medical institutions should aware of this and try to enhance service quality for attaining competitive advantage.

Data Transition Research to Derive Shape Factor in Analyzing Factors -Centering on the body shape of males in twenties- (요인분석시 형태요인을 도출시키기 위한 자료 변환 연구 - 20대 남성 체형을 중심으로 -)

  • 석혜정;김인숙
    • Journal of the Korean Home Economics Association
    • /
    • v.40 no.2
    • /
    • pp.67-86
    • /
    • 2002
  • The purpose of this research is to offer a method to derive the body shapes and pose factors with resets from analyzing factors by using the measurement values of human body. 297 male subjects in their twenties participated in this study. 54 anthropometric and 35 photographic measurements were taken from each subject. Data is the several typical items selected among items and you have to make an index value by using these typical items and convert it. The index has high correlation with each item, is easy to be measured and is to be used after selecting an important item in designing prototype. With results of analyzing reliability level by each item, correlation and items that factor loading is low, the item that the correlation is high is to be removed within the range that maintains the reliability level. Five factors of the front part and seven factors of the profile came to be derived from this kind of process.

Development of Sexual Satisfaction Measurement Tool (여성의 성만족 측정을 위한 도구개발)

  • 김숙남;장순복;강희선
    • Journal of Korean Academy of Nursing
    • /
    • v.27 no.4
    • /
    • pp.753-764
    • /
    • 1997
  • This study was conducted to develop a sexual satisfaction tool for married women in Korea. The data was collected from July 19 to Aug 18, 1997 by means of questionnaires developed by researchers. The subject were 417 married women living in Seoul and Pusan. The process of this study was as follows : 1) The concept of sexual satisfaction was defined. 2) A conceptual framework was identified based on the extensive review of relevant literature and interviews with married women. 3) The preliminary question items containing the attributes and elements of the concept of sexual satisfaction were listed. 4) The preliminary items were revised after a pilot study. 5) The Index of Content Validity(CVI) was calculated from the content specialists' rating. 6) The reliability and validity of the sexual satisfaction measurement tool were tested. As a result of the item and factor analysis, 17 out of 30 items were found to be valid, consequently could be used to measure sexual satisfaction for married women. These final 17 items were divided into two factors. These factors were labeled as "situation factor" (10 items) and "response factor"(7 items) according to the attributes of the clustered items. The reliability of the final 17 items was .9118. Further research is needed to confirm the reliability and validity of the tool by applying it to a group of healthy married women and to a group of married women having health-related problem.

  • PDF

Environmental Stress on the Displacement Sensor for Infrastructure (현장계측용 변위계의 환경영향 특성연구)

  • 이한준;최만용;박정학;임재학
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.114-121
    • /
    • 2004
  • The sensor and measuring instrument that are used for the infrastructure is discussed the reliability problem from the various environment factors. In the domestic infrastructure, the low reliability products are produced, because of lack of the pertinent test methods and equipments. To improve the practical use and accuracy of the sensor, it raises the measurement reliability about the sensor and measurement instrument. In this study, the variance of the displacement value according to temperature was investigated using the LVDT for the infrastructure. The experimental results showed that a sensor is affected by environment factor such as temperature.

  • PDF