• 제목/요약/키워드: Relays Coordination

검색결과 34건 처리시간 0.035초

IEC 표준에 의한 고장전류 계산과 보호협조 (Fault Current Calculation and Coordination by IEC Standards)

  • 손석금
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.6-12
    • /
    • 2014
  • The safety and reliability of the power system short-circuit current, the short-circuit current depends on the failure to obtain the objective is to quickly eliminate the breaking capacity of the circuit-breaker selection of the cable, the insulation of electrical equipment and protective relay an important factor in determining the level correction and protective relay selection scheme to be meaningful. Standards used in the domestic circuit breaker is applied to the production of IEC standard, but the American National Standards (ANSI / IEEE) by NEMA specification of the fault current calculations and the application of the asymmetric coefficient Korea. Therefore, in this paper, the IEC 60909 standard IEC breaker fault current calculation method and the method for selection of system configurations reviewed and protection system for reviewing the configuration of various protective relays appropriate correction and the correction value is main protection, back-up protection the equipment so that the period of protection relay coordination to minimize accidents and accident protection to minimize interruptions proposed for cooperation.

소형 열병합 발전기 계통연계 운전시의 적용 보호지침 개선 제안 (A case Study for Protection Relay System of small Cogeneration intertie)

  • 윤갑구;김경식;현대원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.227-230
    • /
    • 2004
  • The Co-Gen System which maximize energy efficiency was installed at the industrial plants at the initial stage. However Small Scale Co-Gen System was expanded even to the general end-users such as housing and building owing to ESCO business recently. For this SSC, inter-connected operation to the utility is desirable due to voltage and frequency fluctuation following to unbalance between power output and load. Then voltage unbalance with utility system, frequency, increase of short circuit capacity, reclosing, and ALTS etc. should be fully considered for the inter-connected operation. Voltage variation, protection coordination, Co-Generators single running, and short circuit capacity should also be solved. For Con-Gen users, the several protection relays are recommended to install at the user's main incoming panel by the guide lines and/or instructions of the interconnected utility Then user's main CB(Circuit Breaker) have the chance to be tripped by some of this recommended relays and users have to undergo the unexpected blackout. So the circuit breaker trip schemes targeted to trip with these protection relays are reconsidered and the study result is hereunder proposed.

  • PDF

대용량 태양광전원이 연계된 배전선로에 있어서 보호협조기기의 최적 운용알고리즘 (Optimal Operation Algorithm of Protection Devices in Distribution Systems With PV System)

  • 권순환;이후동;남양현;노대석
    • 한국산학기술학회논문지
    • /
    • 제19권5호
    • /
    • pp.17-26
    • /
    • 2018
  • 최근, 대용량의 태양광전원이 연계된 배전계통은 기존의 단방향과 달리 양방향의 조류가 발생하고, 태양광전원의 연계위치 및 고장위치에 따라 사고전류의 크기와 방향이 변하여, 보호기기간의 협조시간차가 충분히 확보되지 않는 문제점이 발생할 수 있다. 또한, 태양광전원을 고려하지 않은 기존의 보호기기 정정치를 그대로 적용하고 있어 보호기기간의 협조시간차를 확보하기 어려운 상황이 발생하고 있다. 따라서 본 논문에서는 태양광전원이 연계된 선로에서 고려할 수 있는 3가지 Case의 보호기기 정정치 운용모드를 제시하고, 이를 바탕으로 태양광전원의 용량에 따른 최적의 보호협조 시간을 도출할 수 있는 알고리즘을 제안한다. 한편, 이를 바탕으로 보호협조 전용소프트웨어인 Off-DAS를 이용하여, 태양광전원이 연계된 배전계통을 모델링하고, 보호기기(변전소 계전기, 리클로저(Recloser), 고객계전기, 태양광전원 고객계전기)간의 협조시간차 특성을 분석한다. 실 계통을 대상으로 시뮬레이션을 수행한 결과, 본 논문에서 제시한 보호기기의 정정치 운용 모드와 정정치 산정 방식이 태양광 전원이 연계된 배전계통 보호기기간의 협조시간을 안정적으로 확보할 수 있음을 알 수 있었다.

전력계통에서의 과전류계전기 보호협조에 관한 연구 (A Study on the Overcurrent Relay Coordination in Power Systems)

  • 최홍규;김경철;오정석;김병철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.351-358
    • /
    • 2004
  • When fault occur in power systems, the protective relay plays a roles of protecting power system according to its setting values. There, it is very important that the protective relay have high selectivity performance in power system by correct setting the relays. This paper analyzed protect device protect cooperation or Transient stability and apply to Overcurrent relay in the real power system operation environment by using EDSA Program.

  • PDF

송전선로 지락사고 보호협조 프로그램 개발 (Program of Development on Protection Coordination for Impedance Fault in Power Transmission System)

  • 김홍석;이승재;최면성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1133-1135
    • /
    • 1999
  • In this paper we propose to develop program witch can improve the detecting capability of impedance fault in power transmission system. It is difficult to setting relay because the different type relays have many setting values to coordinate with each other. The proposed program assist a user in setting relay with convenience grapic environment and database.

  • PDF

송전계통 보호 협조 전문가 시스템의 개발 (Development of Expert System for Protection Coordination of Transmission Systems)

  • 이승재;박영문;심정욱;윤상현;윤만철;이상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.129-132
    • /
    • 1990
  • This paper reports an expert system for coordination of protective relays in the high voltage transmission system. The proposed system consists of five modules and has adopted the frame and production rule representations achieving the efficient data storage and knowledgebases. It has an interface to the fault program PSS/E and has reduced the data retrival time by implementing the local database containg only the minimum information for the process. Different relay parameters and output formats of the setting results can be easily incorporated owing to the rule-based structure. Graphics-based output helps understanding of the process and enhances the practical power.

  • PDF

산업전력계통 보호계전기 협조 자동화 시스템 (Computerized Setting and Coordination System of Protective Relays In Industrial Power System)

  • 이승재;강상희;김기화;김필석;김상태;김봉희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.771-773
    • /
    • 1996
  • This paper reports the protection coordination program, INPROSET for the industrial power system to determine the optimal TAP and Time-Dial of OCRs. INPROSET performs two stages process and the first stage starts form the highest level and depending on its results, the second stage achieves the higher relay operating time. The developed system proved effective through the tests on the real systems.

  • PDF

분산전원 연계 배전계통의 보호협조 정정 프로그램 개발 (A Simulation Program for Protection Coordination in the Power Distribution System with Distributed Generators)

  • 김상옥;서인용;이흥호;노대석
    • 한국시뮬레이션학회논문지
    • /
    • 제22권1호
    • /
    • pp.1-8
    • /
    • 2013
  • 신재생에너지원의 확대 보급 정책과 신재생에너지 공급 의무화 제도(RPS)의 도입으로 배전계통에 연계되는 분산전원이 증가되고 있다. 분산전원이 연계된 배전계통에서는 고장전류의 크기와 방향이 변화하게 되며, 이러한 고장전류의 변화는 기존 보호협조 체계에 대한 재검토를 요구한다. 전력연구원에서는 이러한 고장전류의 변화를 고려할 수 있는 보호협조 정정 알고리즘을 탑재한 시뮬레이션 프로그램을 개발하였다. 본 논문에서는 분산전원 연계 전, 후의 고장전류 변화를 분석하고, 시뮬레이션 프로그램을 이용하여 샘플 계통에 대한 보호협조 정정을 수행하였으며, 분산전원이 배전계통의 보호협조에 미치는 영향에 대하여 고찰하고 그 대책에 대하여 논하고자 한다.

저장 탱크용 임시전력설비의 보호계전기 정정에 관한 연구 (A Study on the Correction of Protection Relay of Temporary Electric Power Installations for Storage Tank)

  • 손석금
    • 한국정보전자통신기술학회논문지
    • /
    • 제13권6호
    • /
    • pp.562-567
    • /
    • 2020
  • 본 논문은 저장 탱크용 임시전력설비를 보호하기 위한 목적으로 특히 변압기를 감시하고 절연파괴 등과 같은 고장을 차단하고 보호하기 위한 보호계전기 정정에 관한 연구이다. 전력계통에 단락 또는 지락고장 등과 같은 이상이 발생하였을 때 이를 검출하여 고장이 발생한 기기 및 설비를 신속하게 차단하고 전력계통으로부터 분리하여 전력공급에 지장이 없도록 하여야 한다. 전력계통의 이상 상태를 빠르고 정확하게 감지할 수 있는 보호계전기의 정정이 중요하다. 또한 보호협조를 위해 고장종류와 고장의 원인을 정확히 적용한 고장전류 계산이 보호계전기 정정에 가장 중요한 요소이다. 저장 탱크용 임시전력설비 보호를 위해 적용하는 과전류계전기, 지락과전류계전기, 부족전압계전기, 지락과전압계전기 등이 보호협조가 가능하도록 보호계전기 정정 방법에 대해 연구하였다.

소형 열병합 발전소의 계통연계시 방향성 과전류 및 지락과전류 계전기의 적용 검증 연구 (A Study of Verification on Application of Directional OCR and OCGR for Power System with Small Scale Cogeneration)

  • 이희태;조만영;김재철
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.944-950
    • /
    • 2008
  • When small cogenerators are operated in connected with power system, there are many positive aspects such as the reduction of power plant construction, making a improvement of power security etc. At the same time, there are some negative effects or difficulties such as we should make sure of protective coordination, especially, Actually these are not fault, but it is likely to consider the current as the fault. This is one of major causes of malfunctions for protective relays in power distribution system which is including interconnection point. Thus, in this paper, We showed that the directional protection is necessary to the dispersed generation system which is including connection point. We also executed contingency analysis to find out the magnitude of fault current and direction which are classified by fault points, length of line and kinds of faults using ETAP power system analysis program.