• 제목/요약/키워드: Relay Zone

검색결과 56건 처리시간 0.03초

과도성분과 상태도를 이용한 거리 계전기의 향상된 Zone 3 알고리즘 (An Enhanced Zone 3 Algorithm of a Distance Relay using Transient Components and State Diagram)

  • 허정용;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권3호
    • /
    • pp.161-167
    • /
    • 2004
  • Zone 3 of the distance relay is used to provide the remote back-up protection in case of the failure of the primary protection. However, the risk lot mal-operations under stressed conditions such as heavy loading, voltage and transient instability is usually high. Zone 3 is used in combination with the derivatives of the voltage, and current, etc to prevent mal-operations. Sometimes, the impedance characteristics that restrict the tripping area of relay are used to avoid the mal-operations due to load encroachment. This paper presents a novel Zone 3 scheme based on combining the steady-state components (i.e. 60Hz) and the transient components (TCs) using a state diagram that visualizes the sequence of studies that emanate from the sequence of events. The simulation results show that the novel zone 3 distance relay elements using the proposed method operates correctly for the various events.

과도성분과 상태도를 이용한 거리 계전기의 향상된 Zone 3 알고리즘 (An Enhanced Zone 3 Algorithm of a Distance Relay using Transient Components and State Diagram)

  • 허정용;김철환;박남옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.245-247
    • /
    • 2003
  • Zone 3 of the distance relay is used to provide the remote back-up protection in case of the failure of the primary protection. However, the risk for mal-operations under stressed conditions such as heavy loading, voltage and transient instability is usually high. Zone 3 is used in combination with the derivatives of the voltage, and current, etc to prevent mal-operations. Sometimes, the impedance characteristics that restrict the tripping area of relay are used to avoid the mal-operations due to load encroachment. This paper presents a novel zone 3 scheme based on combining the steady-state components(i.e. 60Hz) and the transient components(TCs) using a state diagram that visualizes the sequence of studies that emanate from the sequence of events. The simulation results show that the novel zone 3 distance relay elements using the proposed method operates correctly for the various events.

  • PDF

멀티 홉 릴레이 네트워크에서 간섭을 완화하는 동적 자원 할당 기법 (Dynamic Resource Allocation Scheme for Interference Mitigation in Multi-Hop Relay Networks)

  • 안광훈;김태준
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제5권5호
    • /
    • pp.103-108
    • /
    • 2016
  • 본 논문에서는 멀티 홉 릴레이 네트워크에서 기지국(base station), 중계국(relay station)과 각 단말(mobile station)간의 전송률(throughput)을 향상시킬 수 있는 자원 할당 방법과 간섭을 겪는 단말들의 간섭을 최소화하여 모든 단말의 전송률을 보장하는 방법을 제안하고 있다. 멀티 홉 릴레이 시스템에서 기지국과 릴레이가 주파수 자원을 공유할 수 있으므로 간섭에 취약한 단말들이 생길 수 있다. 본 논문에서는 각 단말의 신호대 잡음 간섭 비(signal to interference plus noise ratio)를 이용하여 엑세스 영역(access zone)과 릴레이 영역(relay zone)의 경계를 동적으로 조절하는 기법과 함께 간섭에 취약한 단말을 분류하고 이를 관리하는 기법을 제안한다. 성능 평가를 통해 제안하는 기법이 무선자원 사용의 효율성을 향상하고 각 단말들의 공평성을 보장하며 네트워크 전체 성능을 향상시키는 것을 확인하였다.

송전 계통의 광역정전 징후 시 PMU 취득 데이터를 이용한 거리계전기 Zone3 동작시간 예측 알고리증 (An Algorithm of Predicting the Zone 3 Trip Time of Distance Relay by using PMU Data when Power Systems Face Cascaded Event on Transmission System)

  • 김진환;임일형;이승재;최면송;김태완;임성일;김상태
    • 전기학회논문지
    • /
    • 제58권12호
    • /
    • pp.2303-2310
    • /
    • 2009
  • Defense systems are needed to prevent catastrophic failures of a power grid due to cascaded events. Cascaded events can be attributed to improper operations of protective relays. Especially, it is the most dangerous problem that trips of backup relays by overload. In this paper, a new algorithm of predicting Zone 3 acting time of distance relay is proposed using the real time synchronized data from PMUs on the transmission system when the power system is danger. In the proposed, some part of the power system are outage when some unexpected fault in the power system, the algorithm will monitor the impedance locus of distance relay. At this time, if there is a big change of Impedance locus, the algorithm will calculate the Zone 3 acting time of the distance relay by the over load. In the case studies, the estimation and simulation network have been testified and analysed in Matlab Simulink.

오차를 고려한 송전선 보호 거리계전 정정룰에 대한 고찰 (Examination with Transmission Line Distance Relay Setting Rule Considering Error)

  • 조성진;최면송;현승호;김종욱;이주왕;조범섭;유영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.12-15
    • /
    • 2002
  • Korea Power System Protection Setting Rule was used from the rectify 1990's. Thereafter transmission voltage is raised the voltage into 765kV, and introduction to new technology of Power System, and was many of variation but, it is using. The present is using Digital type distance relay for 765kV transmission line protection. If impedance value of transmission line were to value lower than setting, this would be operating and relay setting rule is for 85% into Zone 1 self section, and Zone 2 is a 125%, Zone 3 is a 225%. Which's $15{\sim}25%$ include current transformer error 5%, potential transformer 5%, relay calculation error 5% and margin factor from the field experience. This paper is discussed transmission protective relay and relay setting rule of high voltage power system and we verify the correctness relay setting rule with distance relay using Matlab simulation.

  • PDF

디지털 거리계전기의 Zone 설정에 관한 연구 (A Study on the Zone Setting of Digital Distance Relay)

  • 이재규;정창호;정병태;안복신;김석일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.946-948
    • /
    • 1998
  • The distance relay is very important for transmission line protection. A quadrilateral zone shape is used mainly for a modern digital distance relay. The shape of quadrilateral is vendor specific. At the stage of design, the shape is determined considering all possible types of faults and diverse configurations of system. Also this type relay must be designed to avoid the operation by a sound phase at single-Phase-to-ground fault, by a sound phase at two-phase-to-ground fault. The effect of a source impedance and a load impedance is another important factor to design. In this paper, a reliable zone shape which is appropriate for the KEPCO's transmission system is provided.

  • PDF

UPFC가 설치된 선로에서 거리계전기의 동작특성에 관한 연구 (A Study for Operation Zone of Distance Relay on Transmission Line Connected UPFC)

  • 정창호;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.130-132
    • /
    • 2001
  • This paper discusses the operation zone of distance relay on transmission line connected unified power flow controller(UPFC). Depending on operating conditions of UPFC, the trip characteristics of distance relay is influenced by the prefault conditions. In this paper, apparent impedance of distance relay influenced by the UPFC control of distance is calculated.

  • PDF

OFDMA 중계 시스템에서 인접셀 간섭과 네트워크 코딩을 고려한 주파수 할당 기법의 성능 평가 (Performance Evaluation of a Subcarrier Allocation Scheme with Inter-Cell Interference and Network Coding in OFDMA Relay Systems)

  • 장우진;손세호;황호영
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 추계학술대회
    • /
    • pp.54-56
    • /
    • 2013
  • 직교 주파수 분할 다중 접속 (OFDMA) 방식을 사용하는 중계 시스템에서는 기지국, 중계기, 사용자에게 어떤 주파수를 할당하느냐에 따라 성능이 달라질 수 있다. 본 논문에서는 OFDMA 중계 시스템에서 인접셀 간섭과 네트워크 코딩을 고려하여 주파수를 할당하는 기법을 제안한다. 네트워크 코딩을 사용하는 구간에서는 중계기가 기지국과 사용자에게 네트워크 코딩을 이용하여 동시에 전송할 수 있는 환경을 고려한다. OFDMA 중계 시스템에서 하향 링크와 상향 링크 및 네트워크 코딩으로 동작하는 구간을 나누고, 각 구간별로 기지국, 중계기, 사용자가 이용하는 주파수를 인접셀 간섭을 고려하여 할당해준다. 제안하는 주파수 할당 기법에 대해서 시뮬레이션을 통해 성능 평가를 수행한다.

  • PDF

Control Strategy against Undesirable Zone 3 Relay Operation in Voltage Instability

  • Lee Byong-Jun;Song Hwa-Chang
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.144-151
    • /
    • 2005
  • This paper presents a framework for determining control strategies against unwanted tripping actions during relay operation that plays a very important role in cascading events leading to voltage collapse. The framework includes an algorithm for quick identification of possible zone 3 relay operation during voltage instability. Furthermore, it comes up with the control strategy of load shedding at the selected location with active power and relay margin criteria. In addition, Quasi Steady-State (QSS) simulation is employed to obtain time-related information that is valuable in the determination of control strategy. As a case study, an example applying the framework is shown with the modified New England 39-bus system.

IEEE802.16j 기반의 2-홉 셀룰러 중계시스템에서 하향링크 접근영역과 중계영역에 대한 최적 무선자원 할당방법 연구 (A Study on the Optimal Wireless Resource Allocation for the Access and Relay Zones of Downlink in a 2-hop Cellular Relay System based on IEEE802.16j)

  • 이인환;김세진;조성호
    • 인터넷정보학회논문지
    • /
    • 제11권3호
    • /
    • pp.43-51
    • /
    • 2010
  • 본 논문에서는OFDMA-TDD 구조를 갖는 IEEE802.16j 기반의 2-홉 셀룰러 중계시스템에서 non-transparent 방식의 무선 중계기를 이용하여 서비스 영역을 확장할 때, 시스템 전송률 및 하향링크 접근영역(Access zone)과 중계영역(Relay zone)에 대한 최적 무선자원 할당방법을 연구한다. 분석을 위해 먼저 non-transparent 방식의 MAC (Media Access Control) 프레임 구조를 알아보고, 접근영역과 중계영역에서 단말과 중계기 등의 네트워크 구성요소들에 대한 간섭요소들을 조사한다. 모의실험을 통하여 기지국과 중계기의 거리에 따라 확장되는 2-홉 셀 커버리지 크기와 전송률을 분석하고, 분석된 결과를 이용하여 하향링크 접근영역과 중계영역에 대한 최적 무선자원 할당량을 제시한다.